Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INDOORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Characterization of fine particulate matter in Ohio: Indoor, outdoor, and personal exposures

Ambient, indoor, and personal PM{sub 2.5} concentrations were assessed based on an exhaustive study of PM{sub 2.5} performed in Ohio from 1999 to 2000. Locations in Columbus, one in an urban corridor and the other in a suburban area were involved. A third rural location in Athens, Ohio, was also established. At all three locations, elementary schools were utilized to determine outdoor, indoor, and personal PM{sub 2.5} concentrations for fourth and fifth grade students using filter-based measurements. Three groups of 30 students each were used for personal sampling at each school. Continuous ambient PM{sub 2.5} mass concentrations were also measured with tapered element oscillating microbalances (TEOMs). At all three sites, personal and indoor PM{sub 2.5} concentrations exceeded outdoor levels. This trend is consistent on all week days and most evident in the spring as compared to fall and winter. The ambient PM{sub 2.5} concentrations were similar among the three sites, suggesting the existence of a common regional source influence. At all the three sites, larger variations were found in personal and indoor PM{sub 2.5} than ambient levels. The strongest correlations were found between indoor and personal concentrations, indicating that personal PM{sub 2.5} exposures were significantly affected by indoor PM{sub 2.5} than by ambient PM{sub 2.5}. This was further confirmed by the indoor to outdoor (I/O) ratios of PM{sub 2.5} concentrations, which were greater when school was in session than non-school days when the students were absent.

54 ENVIRONMENTAL SCIENCES↗

Relationship between domestic smoking and metals and rare earth elements concentration in indoor PM2.5

Highlights: • Tobacco smoke releases heavy metals (HM) and REE in indoor dwellings. • Elemental content in indoor PM{sub 2.5} was measured in smoking and non smoking dwellings. • Extracted and mineralized fractions of elements were evaluated by ICP-MS. • Indoor smoke was associated with increase of specific elemental fractions in PM{sub 2.5}. • Increased levels of HM and REE are associated with respiratory symptoms in children. Cigarette smoke is the main source of indoor chemical and toxic elements. Cadmium (Cd), Thallium (Tl), Lead (Pb) and Antimony (Sb) are important contributors to smoke-related health risks. Data on the association between Rare Earth Elements (REE) Cerium (Ce) and Lanthanum (La) and domestic smoking are scanty. To evaluate the relationship between cigarette smoke, indoor levels of PM{sub 2.5} and heavy metals, 73 children were investigated by parental questionnaire and skin prick tests. The houses of residence of 41 “cases” and 32 “controls” (children with and without respiratory symptoms, respectively) were evaluated by 48-h PM{sub 2.5} indoor/outdoor monitoring. PM{sub 2.5} mass concentration was determined by gravimetry; the extracted and mineralized fractions of elements (As, Cd, Ce, La, Mn, Pb, Sb, Sr, Tl) were evaluated by ICP-MS. PM{sub 2.5} and Ce, La, Cd, and Tl indoor concentrations were higher in smoker dwellings. When corrected for confounding factors, PM{sub 2.5}, Ce, La, Cd, and Tl were associated with more likely presence of respiratory symptoms in adolescents. We found that: i) indoor smoking is associated with increased levels of PM{sub 2.5}, Ce, La, Cd, and Tl and ii) the latter with increased presence of respiratory symptoms in children.

54 ENVIRONMENTAL SCIENCES↗

Indoor versus Outdoor Air Quality during Wildfires

The human behavioral modification recommendations during wildfire events are based on particulate matter and may be confounded by the potential risks of gas-phase pollutants such as polycyclic aromatic hydrocarbons (PAHs). Moreover, the majority of adults spend over 90 percent of their time indoors where there is an increased concern of indoor air quality during wildfire events. We address these timely concerns by evaluating paired indoor and outdoor PAH concentrations in residential locations and their relationship with satellite model-based categorization of wildfire smoke intensity. Low density polyethylene passive air samplers were deployed at six residential sites for one week in Eugene, Oregon with matched indoor and outdoor samples and twenty-four-hour time resolution. Samples were then quantitatively analyzed for 63 PAH concentrations using gas-chromatography. A probabilistic principal components analysis was used to reduce all 63 PAHs into an aggregate measure. Linear regression of the first principal component against indoor versus outdoor shows that indoor gas-phase PAH concentrations are consistently equal or greater than outdoor concentrations. Regression against a satellite-based model for wildfire smoke shows that outdoor, but not indoor gas-phase PAH concentrations are likely associated with wildfire events. Furthermore, these results point towards the need to include gas-phase pollutants such as PAHs in air pollution risk assessment.

54 ENVIRONMENTAL SCIENCES↗

Loudness and annoyance response to simulated outdoor and indoor sonic booms

The sonic boom simulator of the Langley Research Center was used to quantify subjective loudness and annoyance response to simulated indoor and outdoor sonic boom signatures. The indoor signatures were derived from the outdoor signatures by application of house filters that approximated the noise reduction characteristics of a residential structure. Two indoor listening situations were simulated: one with the windows open and the other with the windows closed. Results were used to assess loudness and annoyance as sonic boom criterion measures and to evaluate several metrics as estimators of loudness and annoyance. The findings indicated that loudness and annoyance were equivalent criterion measures for outdoor booms but not for indoor booms. Annoyance scores for indoor booms were significantly higher than indoor loudness scores. Thus, annoyance was recommended as the criterion measure of choice for general use in assessing sonic boom subjective effects. Perceived level was determined to be the best estimator of annoyance for both indoor and outdoor booms, and of loudness for outdoor booms. It was recommended as the metric of choice for predicting sonic boom subjective effects.

Leatherwood, Jack D.↗

Are Ventilation Filters Degrading Indoor Air Quality in California Classrooms?

Heating, ventilating, and cooling classrooms in California consume substantial electrical energy. Indoor air quality (IAQ) in classrooms affects studenthealth and performance. In addition to airborne pollutants that are emitted directly by indoor sources and those generated outdoors, secondary pollutants can be formed indoors by chemical reaction of ozone with other chemicals and materials. Filters are used in nearly all classroom heating, ventilation and air?conditioning (HVAC) systems to maintain energy-efficient HVAC performance and improve indoor air quality; however, recent evidence indicates that ozone reactions with filters may, in fact, be a source of secondary pollutants. This project quantitatively evaluated ozone deposition in HVAC filters and byproduct formation, and provided a preliminary assessment of the extent towhich filter systems are degrading indoor air quality. The preliminary information obtained will contribute to the design of subsequent research efforts and the identification of energy efficient solutions that improve indoor air quality in classrooms and the health and performance of students.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Metal Oxide vs Organic Semiconductor Charge Extraction Layers for Halide Perovskite Indoor Photovoltaics

Halide perovskite indoor photovoltaics (PVs) are highly promising to autonomously power the billions of microelectronic sensors in the emerging and disruptive technology of the Internet of Things (IoT). However, how the wide range of different types of hole extraction layers (HELs) impacts the indoor light harvesting of perovskite solar cells is still elusive, which hinders the material selection and industrial–scale fabrication of indoor perovskite photovoltaics. In the present study, new insights are provided regarding the judicial selection of HELs at the buried interface of halide perovskite indoor photovoltaics. This study unravels the detrimental and severe light–soaking effect of metal oxide transport layer–based PV devices under the indoor lighting effect for the first time, which then necessitates the interface passivation/engineering for their reliant performance. This is not a stringent criterion under 1 sun illumination. By systematically investigating the charge carrier dynamics and sequence of measurements from dark, light–soaked, interlayer–passivated device, the bulk and interface defects are decoupled and reveal the gradual defect passivation from shallow to deep level traps. Thus, the present study puts forward a useful design strategy to overcome the deleterious effect of metal oxide HELs and employ them in halide perovskite indoor PVs.

14 SOLAR ENERGY↗

Statistical Analysis and Interpretation of Building Characterization, Indoor Environmental Quality Monitoring and Energy Usage Data from Office Buildings and Classrooms in the United States

Three independent tasks had been performed (Stetzenbach 2008, Stetzenbach 2008b, Stetzenbach 2009) to measure a variety of parameters in normative buildings across the United States. For each of these tasks 10 buildings were selected as normative indoor environments. Task 1 focused on office buildings, Task 13 focused on public schools, and Task 0606 focused on high performance buildings. To perform this task it was necessary to restructure the database for the Indoor Environmental Quality (IEQ) data and the Sound measurement as several issues were identified and resolved prior to and during the transfer of these data sets into SPSS. During overview discussions with the statistician utilized in this task it was determined that because the selection of indoor zones (1-6) was independently selected within each task; zones were not related by location across tasks. Therefore, no comparison would be valid across zones for the 30 buildings so the by location (zone) data were limited to three analysis sets of the buildings within each task. In addition, differences in collection procedures for lighting were used in Task 0606 as compared to Tasks 01 & 13 to improve sample collection. Therefore, these data sets could not be merged and compared so effects by-day data were run separately for Task 0606 and only Task 01 & 13 data were merged. Results of the statistical analysis of the IEQ parameters show statistically significant differences were found among days and zones for all tasks, although no differences were found by-day for Draft Rate data from Task 0606 (p>0.05). Thursday measurements of IEQ parameters were significantly different from Tuesday, and most Wednesday measures for all variables of Tasks 1 & 13. Data for all three days appeared to vary for Operative Temperature, whereas only Tuesday and Thursday differed for Draft Rate 1m. Although no Draft Rate measures within Task 0606 were found to significantly differ by-day, Temperature measurements for Tuesday and Thursday showed variation. Moreover, Wednesday measurements of Relative Humidity within Task 0606 varied significantly from either Tuesday or Thursday. The majority of differences in IEQ measurements by-zone were highly significant (p<0.001), with the exception of Relative Humidity in some buildings. When all task data were combined (30 buildings) neither the airborne culturable fungi nor the airborne non-culturable spore data differed in the concentrations found at any indoor location in terms of day of collection. However, the concentrations of surface-associated fungi varied among the day of collection. Specifically, there was a lower concentration of mold on Tuesday than on Wednesday, for all tasks combined. As expected, variation was found in the concentrations of both airborne culturable fungi and airborne non-culturable fungal spores between indoor zones (1-6) and the outdoor zone (zone 0). No variation was found among the indoor zones of office buildings for Task 1 in the concentrations of airborne culturable fungi. However, airborne non-culturable spores did vary among zones in one building in Task 1 and variation was noted between zones in surface-associated fungi. Due to the lack of multiple lighting measurements for Tasks 13 and 0606, by-day comparisons were only performed for Task 1. No statistical differences were observed in lighting with respect to the day of collection. There was a wide range of variability by-zone among seven of the office buildings. Although few differences were found for the brightest illumination of the worksurface (IllumWkSfcBrtst) and the darkest illumination of the worksurface (IllumWkSfcDrkst) in Task 1, there was considerable variation for these variables in Task 13 and Task 0606 (p < 0.001). Other variables that differed by-zone in Task 13 include CombCCT and AmbCCT1 for S03, S07, and S08. Additionally, AmbChromX1, CombChromY, and CombChromX varied by-zone for school buildings S02, S04, and S05, respectively. Although all tasks demonstrated significant differences in sound measurements by zone, some of the buildings within each task did not appear to differ in sound quality. Hence, post-hoc tests were not appropriate and individual zones were not compared for these buildings. It is interesting to note that sound measurements in some buildings were widely varied with most zone comparisons and other buildings varied between only a few zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Surveillance of Aedes aegypti indoors and outdoors using Autocidal Gravid Ovitraps in South Texas during local transmission of Zika virus, 2016 to 2018

The yellow fever mosquito, Aedes aegypti, has facilitated the re-emergence of dengue virus (DENV) and emergence of chikungunya virus (CHIKV) and Zika virus (ZIKV) in the Americas and the Caribbean. The recent transmission of these arboviruses in the continental United States has been limited, to date, to South Florida and South Texas despite Ae. aegypti occurring over a much larger geographical region within the country. The main goal of our study was to provide the first long term longitudinal study of Ae. aegypti and enhance the knowledge about the indoor and outdoor relative abundance of Ae. aegypti as a proxy for mosquito-human contact in South Texas, a region of the United States that is at high risk for mosquito-borne virus transmission. Here, the relative abundance of indoors and outdoors mosquitoes of households in eight different communities was described. Surveillance was done weekly from September 2016 to April 2018 using the CDC Autocidal Gravid Ovitraps in low- and middle-income communities. A total of 69 houses were included in this survey among which 36 were in the low-income communities (n = 11 for Donna, n = 15 for Progresso, n = 5 for Mesquite, n = 5 for Chapa) and 33 in middle-income communities (n = 9 for La Feria, n = 8 for Weslaco, n = 11 for McAllen, and n = 5 for Rio Rico). Overall, Ae. aegypti was the dominant species (59.2% of collections, n = 7255) followed by Culex spp. mosquitoes (27.3% of collections, n = 3350). Furthermore, we demonstrated for Ae. aegypti that 1) outdoor relative abundance was higher compared to indoor relative abundance, 2) low-income communities were associated with an increase in mosquito relative abundance indoors when compared to middle-income communities, 3) no difference was observed in the number of mosquitoes collected outdoors between low-income and middle-income communities, and 4) warmer months were positively correlated with outdoor relative abundance whereas no seasonality was observed in the relative abundance of mosquitoes indoors. Additionally, Ae. aegypti mosquitoes collected in South Texas were tested using a specific ZIKV/CHIKV multiplex real-time PCR assay, however, none of the mosquitoes tested positive. Our data highlights the occurrence of mosquitoes indoors in the continental United States and that adults are collected nearly every week of the calendar year. These mosquito data, obtained concurrently with local ZIKV transmission of 10 locally acquired cases in nearby communities, represent a baseline for future studies in the Lower Rio Grande Valley (LRGV) including vector control interventions relying on the oviposition behavior to reduce mosquito populations and pathogen transmission.

59 BASIC BIOLOGICAL SCIENCES↗

A review of smart building sensing system for better indoor environment control

Here this paper aims to provide a systemic review of how indoor sensors influence in managing optimal energy saving, thermal comfort, visual comfort, and indoor air quality in the built environment. The optimal management of energy saving and occupant comfort plays a vital role in the built environment because the occupant's productivity and health are highly influenced by indoor environmental quality. In order to do this, there must be a functional sensing system that connects the environment variables (e.g., temperature) with building environmental control systems such as the heating, ventilation, and air-conditioning system. This paper starts with an overview of the importance of energy saving and occupant comfort in the built environment. It then discusses sensors and their importance in the built environment and reviews the different types of sensors, which explains them in terms of how they influence the indoor built environment and occupant productivity. The paper further explores the application of sensors in the built environment and analyzes this in terms of energy saving, thermal comfort, visual comfort, and indoor air quality. Following this, the data analysis is discussed in terms of data, information, and knowledge accrued from the sensors. Lastly, the paper discusses the future challenges for the improvement of building indoor environmental quality and energy saving by the application of sensors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Children's exposure to indoor air in urban nurseries-part I: CO{sub 2} and comfort assessment

Indoor air quality (IAQ) in nurseries is an emerging case-study. Thus, this study, as the Part I of the larger study “Children's exposure to indoor air in urban nurseries”, aimed to: i) evaluate nurseries’ indoor concentrations of carbon dioxide (CO{sub 2}), a global IAQ indicator, in class and lunch rooms; ii) assess indoor comfort parameters–temperature (T) and relative humidity (RH); and iii) analyse them according to guidelines and references for IAQ, comfort and children's health. Indoor continuous measurements were performed. Non-compliances with guidelines were found in comfort parameters, which could cause discomfort situations and also microbial proliferation. Exceedances in CO{sub 2} concentrations were also found and they were caused by poor ventilation and high classroom occupation. More efficient ventilation and control of comfort parameters, as well as to reduce occupation by reviewing Portuguese legislation on that matter, would certainly improve IAQ and comfort in nurseries and consequently safeguard children's health. - Highlights: • High occupation and poor ventilation were main determinants of IAQ in nurseries. • T and RH indoor values found in nurseries are likely to cause thermal discomfort. • Building characteristics and an inadequate ventilation determined T and RH values. • High CO{sub 2} concentrations found could indicate accumulation of other air pollutants.

54 ENVIRONMENTAL SCIENCES↗

Over 31% efficient indoor organic photovoltaics enabled by simultaneously reduced trap-assisted recombination and non-radiative recombination voltage loss

Indoor organic photovoltaics (OPVs) have shown great potential application in driving low-energy-consumption electronics for the Internet of Things. There is still great room for further improving the power conversion efficiency (PCE) of indoor OPVs, considering that the desired morphology of the active layer to reduce trap-assisted recombination and voltage losses and thus simultaneously enhance the fill factor (FF) and open-circuit voltage for efficient indoor OPVs remains obscure. Herein, by optimizing the bulk and interface morphology via a layer-by-layer (LBL) processing strategy, low leakage current and low non-radiative recombination loss can be synergistically achieved in PM6:Y6-O based devices. Detailed characterizations reveal the stronger crystallinity, purer domains and ideal interfacial contacts in the LBL devices compared to their bulk-heterojunction (BHJ) counterparts. The optimized morphology yields a reduced voltage loss and an impressive FF of 81.5%, and thus contributes to a high PCE of 31.2% under a 1000 lux light-emitting diode (LED) illumination in the LBL devices, which is the best reported efficiency for indoor OPVs. Additionally, this LBL strategy exhibits great universality in promoting the performance of indoor OPVs, as exemplified by three other non-fullerene acceptor systems. Finally, this work provides guidelines for morphology optimization and synergistically promotes the fast development of efficient indoor OPVs.

36 MATERIALS SCIENCE↗

Spatial and temporal variations in indoor environmental conditions, human occupancy, and operational characteristics in a new hospital building

The dynamics of indoor environmental conditions, human occupancy, and operational characteristics of buildings influence human comfort and indoor environmental quality, including the survival and progression of microbial communities. A suite of continuous, long-term environmental and operational parameters were measured in ten patient rooms and two nurse stations in a new hospital building in Chicago, IL to characterize the indoor environment in which microbial samples were taken for the Hospital Microbiome Project. Measurements included environmental conditions (indoor dry-bulb temperature, relative humidity, humidity ratio, and illuminance) in the patient rooms and nurse stations; differential pressure between the patient rooms and hallways; surrogate measures for human occupancy and activity in the patient rooms using both indoor air CO₂ concentrations and infrared doorway beam-break counters; and outdoor air fractions in the heating, ventilating, and air-conditioning systems serving the sampled spaces. Measurements were made at 5-minute intervals over consecutive days for nearly one year, providing a total of ~8×10⁶ data points. Indoor temperature, illuminance, and human occupancy/activity were all weakly correlated between rooms, while relative humidity, humidity ratio, and outdoor air fractions showed strong temporal (seasonal) patterns and strong spatial correlations between rooms. Differential pressure measurements confirmed that all patient rooms were operated at neutral pressure. The patient rooms averaged about 100 combined entrances and exits per day, which suggests they were relatively lightly occupied compared to higher traffic environments (e.g., retail buildings) and more similar to lower traffic office environments. There were also clear differences in several environmental parameters before and after the hospital was occupied with patients and staff. Characterizing and understanding factors that influence these building dynamics is vital for hospital environments, where they can impact patient health and the survival and spread of healthcare associated infections.

54 ENVIRONMENTAL SCIENCES↗

Pilot Implementation of a Field Study Design to Evaluate the Impact of Source Control Measures on Indoor Air Quality in High Performance Homes

To improve the indoor air quality in new, high performance homes, a variety of standards and rating programs have been introduced to identify building materials that are designed to have lower emission rates of key contaminants of concern and a number of building materials are being introduced that are certified to these standards. For example, the U.S. Department of Energy (DOE) Zero Energy Ready Home program requires certification under the U.S. Environmental Protection Agency (EPA) Indoor airPLUS (IaP) label, which requires the use of PS1 or PS2 certified plywood and OSB; low-formaldehyde emitting wood products; low- or no-VOC paints and coatings as certified by Green Seal Standard GS-11, GreenGuard, SCS Indoor Advantage Gold Standard, MPI Green Performance Standard, or another third party rating program; and Green Label-certified carpet and carpet cushions. However, little is known regarding the efficacy of the IAP requirements in measurably reducing contaminant exposures in homes. The goal of this project is to develop a robust experimental approach and collect preliminary data to support the evaluation of indoor air quality (IAQ) measures linked to IAP-approved low-emitting materials and finishes in new residential homes. To this end, the research team of Pacific Northwest National Laboratory (PNNL) and Lawrence Berkeley National Laboratory (LBNL) developed a detailed experimental plan to measure IAQ constituents and other parameters, over time, in new homes constructed with materials compliant with IAP’s low-emitting material and ventilation requirements (i.e., section 6.1, 6.2, 6.3, and 7.2) and similar homes constructed to the state building code with conventional materials. The IAQ in IAP and conventional homes of similar age, location, and construction style is quantified as the differences in the speciated VOC and aldehyde concentrations, normalized to dilution rates. The experimental plan consists of methods to evaluate the difference between low-emitting and “conventional” materials as installed in newly constructed residential homes using both (1) highly controlled, short-term active samples to precisely characterize the building-related chemical emissions and building contents and (2) a week-long passive sample designed to capture the impact of occupant behavior and related activities on measured IAQ contaminant levels indoors. The combination of detailed short-term measurements with the home under controlled/consistent conditions during pre- and post-occupancy and the week-long passive sampling data provide the opportunity to begin to separate the different emission sources and help isolate and quantify variability in the monitored homes. Between April and August 2014, the research team performed pre-occupancy and post-occupancy sampling in one conventional home and two homes built with low-emitting materials that were generally consistent with EPA’s Indoor airPLUS guidelines. However, for a number of reasons, the full experimental plan was not implemented. The project was intended to continue for up to three years to asses long-term changes in IAQ but the project was limited to one calendar year. As a result, several of the primary research questions related to seasonal impacts and the long-term trends in IAQ could not be addressed. In addition, there were several unexpected issues related to recruiting, availability of home types, and difficulty coordinating with builders/realtors/homeowners. Several field monitoring issues also came up that provide “lessons learned” that led to improvements to the original monitoring plan. The project produced a good experimental plan that is expected to be be useful for future efforts collecting data to support answering these same or similar research questions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ventilation and Indoor Air Quality in New California Homes with Gas Appliances and Mechanical Ventilation

Substantial energy is used to condition the air that enters California homes through leaks in the building envelope and ductwork - typically about a third of all heating and cooling. Reducing this through air sealing is essential to California achieving zero energy homes. However, this outdoor air also dilutes pollutants emitted inside homes and contributes to a healthy indoor environment and acceptable indoor air quality (IAQ). To address this IAQ issue, California’s Title 24 Building Standards have required mechanical ventilation in new homes since 2008. This report presents a comprehensive study of the impacts of these requirements in recently constructed homes with natural gas appliances. The study included a survey about satisfaction and activities that impact IAQ; a field study of homes built to 2008 or later; and simulations assessing how various ventilation rates would impact chronic exposures to an indoor emitted pollutant as air tightness improves in California. The report focuses on the field study; the webbased survey and simulation elements are described in appendices. The field study characterized 70 homes built between 2011 and 2017. Each home was monitored over roughly one week with the dwelling unit mechanical ventilation system operating and windows closed. Pollutant measurements included time-resolved fine particulate matter (PM 2.5 ) indoors and outdoors, and formaldehyde, nitrogen dioxide (NO 2 ), and carbon dioxide (CO 2 ) indoors. Time-integrated measurements were made for formaldehyde, NO 2 and nitrogen oxides (NO X ) indoors and outdoors at all homes. Activity monitoring devices were installed on the cooktop, range hood and other exhaust fans, and the heating and cooling system. The field study found that most homes met most ventilation requirements and the dwelling unit ventilation fans on average moved 50% more airflow than the minimum specified in Title 24. Air pollutant concentrations were similar or lower than those reported in a study of recent construction California new homes conducted in 2007-08. Notably, the median formaldehyde level was 38% lower than in the prior study. Measured concentrations were below health guidelines for most pollutants, indicating that IAQ is acceptable in new California homes when dwelling unit mechanical ventilation is used. However, the dwelling unit mechanical ventilation fans were only operating in one quarter of the homes when first visited and the control switches in many homes did not have informative labels as required by the standards. Corrective action needs to be taken to improve labeling and controls for ventilation systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A review of antimicrobial implications for improving indoor air quality

The frequent outbreak of infectious respiratory diseases, such as the recent COVID-19 epidemic, raised the importance of indoor air quality. Removing microorganisms from indoor air is critical to improve indoor air quality. Numerous studies in recent years have been published on developing antimicrobial materials and technologies for antibacterial and antiviral applications. Further, this study critically reviews the recent antimicrobial advances for improving indoor air quality. This paper provides a comprehensive analysis of the antimicrobial mechanisms, development of materials, and deployment strategies, as well as a performance evaluation of the antimicrobial implication for indoor air quality. Furthermore, the challenges and opportunities of future research directions are also highlighted.

59 BASIC BIOLOGICAL SCIENCES↗

Cool rooms for indoor heat resilience: Evaluating affordable cooling strategies in heat-stressed California homes

Extreme heat conditions pose significant indoor survivability challenges for resource-constrained communities, which often lack access to cooling, have poorly insulated homes, and face compounding socioeconomic vulnerabilities. Moreover, concurrent power outages worsen health risks and heat-related illnesses. It is therefore crucial to develop innovative and affordable cooling approaches to protect vulnerable populations. This study assesses the efficacy of “cool rooms”– a designated space within a home equipped with passive and low-power active cooling measures to maintain safe indoor temperatures during extreme heat events and power disruptions. Using a physics-based building energy modeling approach, we evaluate the efficacy of various retrofit packages in maintaining thermal safety within the cool room under recent extreme heat conditions. The results indicate that passive measures can reduce 64% of hours with unmet standard effective temperatures, while the combination of passive and low-power active measures with built-in batteries further cuts this to 86%. Nevertheless, these strategies remain insufficient to maintain indoor thermal safety during extended outages. In contrast, integrating a solar-powered mini-split heat pump, whose technical potential was evaluated in this study, reduces indoor air temperatures below the 28 °C overheating threshold and significantly improves indoor habitability. The localized cool room strategy also offers potential for grid resilience by reducing peak electricity demand by up to 70% compared to whole house cooling during heat waves. The findings can inform the development of actionable heat mitigation plans and retrofit policies for residential communities with relatively low adoption of air conditioning such as warm marine climates.

Cool room↗

Investigating the influence of environmental information on perceived indoor environmental quality: An exploratory study

Under the assumption that information can impact perception, most research on human sensation and satisfaction with indoor environmental quality (IEQ) parameters has been conducted with respondents uninformed about the test conditions. Therefore, researchers know little about the impact of information on perception. These potential effects are increasingly relevant as quantitative information about indoor environments becomes accessible via low-cost, wirelessly connected sensors. In this experimental study, 48 subjects were exposed to varied indoor environmental conditions and provided with different types of environmental information. The subjects' sensation and satisfaction were compared when they were blinded or provided with quantitative information about and/or qualitative ratings of specific parameters. The results indicate that accurate information on parameter values influenced how the subjects perceived the indoor air quality (IAQ) but not how they perceived the thermal, acoustic, or visual quality. The subjects rated the IAQ more positively when they were informed that there were nonzero ventilation rates. The qualitative ratings influenced the subjects' perceptions of all four environmental factors, but in different directions. The subjects generally had more positive sensation and higher satisfaction when they were told that the parameter values and qualitative ratings were more favorable than the test conditions. However, the improved sensation and satisfaction were often not as good as when the environmental conditions were actually improved and the subjects were provided with accurate information. Here, these findings affirm the critical need for more research on the impacts of information on perceptions of the indoor environment.

42 ENGINEERING↗

Optimizing spectral and morphological match of nonfullerene acceptors toward efficient indoor organic photovoltaics with enhanced light source adaptability

High-performance indoor organic photovoltaics (IOPV) require large-bandgap material systems to absorb visible light efficiently and reduce energy loss. However, state-of-the-art non-fullerene acceptors (NFAs) have absorptions in the near-infrared region and are thus not suitable for IOPV applications. Herein, we report a series of large-bandgap (>1.70 eV) NFAs named FCC-Cl-C8, FCC-Cl-4Ph and FCC-Cl-6Ph by modifying the alkyl side chains with alkylphenyl chains partially or completely. Results show that the bulky alkylphenyl side chains can finely tune the absorption properties of the NFAs and also affect their morphological properties. Interestingly, the best-performing NFA is the one (named FCC-Cl-4Ph) with partial alkyl and alkylphenyl substitutions, which blue-shift the absorption of the NFAs while minimizing the negative morphological effect of the bulky alkylphenyl chains. As a result, FCC-Cl-4Ph can achieve excellent indoor efficiencies over 29% under a 3000 K LED lamp at 1000 lux and show better solution processability over FCC-Cl-C8. More importantly, FCC-Cl-4Ph can maintain high indoor performance (29.7–26.8% at 1000 lux) under a wide range of indoor lighting spectra (2600, 3000, 4000, and 6500 K LED lamps), which should be due to the blue-shifted spectra of FCC-Cl-4Ph and better matching with various indoor conditions. Finally, this work reveals an interesting structure-property relationship and offers useful strategies for the further design of NFAs toward efficient IOPV devices.

14 SOLAR ENERGY↗