Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INDIUM 111”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Use of Local {sup 111}In-Capromab Pendetide Scan Results to Predict Outcome After Salvage Radiotherapy for Prostate Cancer

Purpose: The {sup 111}In-capromab pendetide scan (ProstaScint; Cytogen Corp., Princeton NJ) is approved by the Food and Drug Administration to evaluate increasing prostate-specific antigen (PSA) levels after radical prostatectomy. This study evaluated the role of prostate bed {sup 111}In-capromab pendetide scan findings to predict response to salvage radiotherapy (RT). Methods and Materials: Forty patients who had PSA recurrence after radical prostatectomy and a {sup 111}In-capromab pendetide scan immediately before salvage prostate bed RT (median, 66 Gy) were identified from the Duke Prostate Center database. Patients with distant uptake of capromab pendetide or long-term androgen deprivation therapy were excluded. Median follow-up after salvage RT was 2.7 years. Patient demographic, clinical, and pathologic characteristics; PSA values; and {sup 111}In-capromab pendetide scan results were retrospectively analyzed. A PSA failure after salvage RT was defined as PSA level greater than 0.2 ng/ml. Data were combined with other published results in a secondary pooled analysis of 106 patients. Results: {sup 111}In-Capromab pendetide findings included 20 patients with negative scan results and 20 with locally positive scan results. Two-year progression-free survival rates were 60% for patients with a negative scan result and 74% for those with a locally positive scan result (p = 0.49). Combined analysis did not show a difference in outcome based on local {sup 111}In-capromab pendetide scan result. Conclusion: For patients without distant signal detected by using {sup 111}In-capromab pendetide scan, patients with locally positive scan findings did not have statistically different progression-free survival than those with a negative scan result, suggesting that salvage RT may be successful in patients with either a locally positive or negative {sup 111}In-capromab pendetide scan result.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of an inflammation imaging tracer, {sup 111}In-DOTA-DAPTA, targeting chemokine receptor CCR5 and preliminary evaluation in an ApoE{sup −/−} atherosclerosis mouse model

Background: Chemokine receptor 5 (CCR5) plays an important role in atherosclerosis. Our objective was to develop a SPECT tracer targeting CCR5 for imaging plaque inflammation by radiolabeling D-Ala-peptide T-amide (DAPTA), a CCR5 antagonist, with {sup 111}In. Methods: 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) conjugated DAPTA (DOTA-DAPTA) was labeled with {sup 111}In. Cell uptake studies were conducted in U87-CD4-CCR5 and U87-MG cells. Biodistribution was determined in C57BL/6 mice. Autoradiography, en face and Oil Red O (ORO) imaging studies were performed in ApoE{sup −/−} mice. Results: DOTA-DAPTA was radiolabeled with {sup 111}In with high radiochemical purity (> 98%) and specific activity (70 MBq·nmol). {sup 111}In-DOTA-DAPTA exhibited fast blood and renal clearance and high spleen uptake. The U87-CD4-CCR5 cells had significantly higher uptake in comparison to the U87-MG cells. The cell uptake was reduced by three times with DAPTA, indicating the receptor specificity of the uptake. Autoradiographic images showed significantly higher lesion uptake of {sup 111}In-DOTA-DAPTA in ApoE{sup −/−} mice than that in C57BL/6 mice. The tracer uptake in 4 month old ApoE{sup −/−} high fat diet (HFD) mice with blocking agent was twofold lower than the same mice without the blocking agent, demonstrating the specificity of the tracer for the CCR5 receptor. Conclusion: {sup 111}In-DOTA-DAPTA, specifically targeting chemokine receptor CCR5, is a potential SPECT agent for imaging inflammation in atherosclerosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relationship Between Chromatin Structure and Sensitivity to Molecularly Targeted Auger Electron Radiation Therapy

Purpose: The open structure of euchromatin renders it susceptible to DNA damage by ionizing radiation (IR) compared with compact heterochromatin. The effect of chromatin configuration on the efficacy of Auger electron radiotherapy was investigated. Methods and Materials: Chromatin structure was altered in MDA-MB-468 and 231-H2N human breast cancer cells by suberoylanilide hydroxamic acid (SAHA), 5-aza-2-deoxycytidine, or hypertonic treatment. The extent and duration of chromatin structural changes were evaluated using the micrococcal nuclease assay. DNA damage ({gamma}H2AX assay) and clonogenic survival were evaluated after exposure to {sup 111}In-DTPA-hEGF, an Auger electron-emitting radiopharmaceutical, or IR. The intracellular distribution of {sup 111}In-DTPA-hEGF after chromatin modification was investigated in cell fractionation experiments. Results: Chromatin remained condensed for up to 20 minutes after NaCl and in a relaxed state 24 hours after SAHA treatment. The number of {gamma}H2AX foci per cell was greater in MDA-MB-468 and 231-H2N cells after IR (0.5 Gy) plus SAHA (1 {mu}M) compared with IR alone (16 {+-} 0.6 and 14 {+-} 0.3 vs. 12 {+-} 0.4 and 11 {+-} 0.2, respectively). More {gamma}H2AX foci were observed in MDA-MB-468 and 231-H2N cells exposed to {sup 111}In-DTPA-hEGF (6 MBq/{mu}g) plus SAHA vs. {sup 111}In-DTPA-hEGF alone (11 {+-} 0.3 and 12 {+-} 0.7 vs. 9 {+-} 0.4 and 7 {+-} 0.3, respectively). 5-aza-2-deoxycytidine enhanced the DNA damage caused by IR and {sup 111}In-DTPA-hEGF. Clonogenic survival was reduced in MDA-MB-468 and 231-H2N cells after IR (6 Gy) plus SAHA (1 {mu}M) vs. IR alone (0.6% {+-} 0.01 and 0.3% {+-} 0.2 vs. 5.8% {+-} 0.2 and 2% {+-} 0.1, respectively) and after {sup 111}In-DTPA-hEGF plus SAHA compared to {sup 111}In-DTPA-hEGF alone (21% {+-} 0.4% and 19% {+-} 4.6 vs. 33% {+-} 2.3 and 32% {+-} 3.7). SAHA did not affect {sup 111}In-DTPA-hEGF nuclear localization. Hypertonic treatment resulted in fewer {gamma}H2AX foci per cell after IR and {sup 111}In-DTPA-hEGF compared to controls but did not significantly alter clonogenic survival. Conclusions: Chromatin structure affects DNA damage and cell survival after exposure to Auger electron radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging of atherosclerosis, targeting LFA-1 on inflammatory cells with {sup 111}In-DANBIRT

Background: {sup 111}In-DOTA-butylamino-NorBIRT (DANBIRT) is a novel radioligand which binds to Leukocyte Function-associated Antigen-1 (LFA-1), expressed on inflammatory cells. This study evaluated {sup 111}In-DANBIRT for the visualization of atherosclerotic plaque inflammation in mice. Methods and Results: ApoE{sup −/−} mice, fed an atherogenic diet up to 20 weeks (n = 10), were imaged by SPECT/CT 3 hours post injection of {sup 111}In-DANBIRT (~ 200 pmol, ~ 40 MBq). Focal spots of {sup 111}In-DANBIRT were visible in the aortic arch of all animals, with an average Target-to-Background Ratio (TBR) of 1.7 ± 0.5. In vivo imaging results were validated by ex vivo SPECT/CT imaging, with a TBR up to 11.5 (range 2.6 to 11.5). Plaques, identified by Oil Red O lipid-staining on excised arteries, co-localized with {sup 111}In-DANBIRT uptake as determined by ex vivo autoradiography. Subsequent histological processing and in vitro autoradiography confirmed {sup 111}In-DANBIRT uptake at plaque areas containing CD68 expressing macrophages and LFA-1 expressing inflammatory cells. Ex vivo incubation of a human carotid endarterectomy specimen with {sup 111}In-DANBIRT (~ 950 nmol, ~ 190 MBq) for 2 hours showed heterogeneous plaque uptake on SPECT/CT, after which immunohistochemical analysis demonstrated co-localization of {sup 111}In-DANBIRT uptake and CD68 and LFA-1 expressing cells. Conclusions: Our results indicate the potential of radiolabeled DANBIRT as a relevant imaging radioligand for non-invasive evaluation of atherosclerotic inflammation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Choosing the optimal fit function: Comparison of the Akaike information criterion and the F-test

In many circumstances of data fitting one has to choose the optimal fitting function or model among several alternatives. Criteria or tests on which this decision is based are necessary and have to be well selected. In this preliminary analysis the application of the corrected Akaike information criterion is demonstrated considering the example of determining pharmacokinetic parameters for the blood serum time activity curves of {sup 111}In-labeled anti-CD66 antibody. Another model selection criterion, the F-test, is used for comparison. For the investigated data the corrected Akaike information criterion has proved to be an effective and efficient approach, applicable to nested and non-nested models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Formation of medical radioisotopes {sup 111}In, {sup 117m}Sn, {sup 124}Sb, and {sup 177}Lu in photonuclear reactions

The possibility of the photonuclear production of radioisotopes {sup 111}In, {sup 117m}Sn, {sup 124}Sb, and {sup 177}Lu is discussed. Reaction yields were measured by the gamma-activation method. The enriched tin isotopes {sup 112,} {sup 118}Sn and Te and HfO{sub 2} of natural isotopic composition were used as targets. The targets were irradiated at the linear electron accelerator of Alikhanian National Science Laboratory (Yerevan) at the energy of 40 MeV. The experimental results obtained in this way reveal that the yield and purity of radioisotopes {sup 111}In and {sup 117}mSn are acceptable for their production via photonuclear reactions. Reactions proceeding on targets from Te and HfO{sub 2} of natural isotopic composition and leading to the formation of {sup 124}Sb and {sup 177}Lu have small yields and are hardly appropriate for the photoproduction of these radioisotopes even in the case of enriched targets.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantifying selective alignment of ensemble nitrogen-vacancy centers in (111) diamond

Selective alignment of nitrogen-vacancy (NV) centers in diamond is an important technique towards its applications. Quantification of the alignment ratio is necessary to design the optimized diamond samples. However, this is not a straightforward problem for dense ensemble of the NV centers. We estimate the alignment ratio of ensemble NV centers along the [111] direction in (111) diamond by optically detected magnetic resonance measurements. Diamond films deposited by N{sub 2} doped chemical vapor deposition have NV center densities over 1 × 10{sup 15 }cm{sup −3} and alignment ratios over 75%. Although spin coherence time (T{sub 2}) is limited to a few μs by electron spins of nitrogen impurities, the combination of the selective alignment and the high density can be a possible way to optimize NV-containing diamond samples for the sensing applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Combination of External Beam Radiotherapy (EBRT) With Intratumoral Injection of Dendritic Cells as Neo-Adjuvant Treatment of High-Risk Soft Tissue Sarcoma Patients

Purpose: The goal of this study was to determine the effect of combination of intratumoral administration of dendritic cells (DC) and fractionated external beam radiation (EBRT) on tumor-specific immune responses in patients with soft-tissue sarcoma (STS). Methods and Material: Seventeen patients with large (>5 cm) high-grade STS were enrolled in the study. They were treated in the neoadjuvant setting with 5,040 cGy of EBRT, split into 28 fractions and delivered 5 days per week, combined with intratumoral injection of 10{sup 7} DCs followed by complete resection. DCs were injected on the second, third, and fourth Friday of the treatment cycle. Clinical evaluation and immunological assessments were performed. Results: The treatment was well tolerated. No patient had tumor-specific immune responses before combined EBRT/DC therapy; 9 patients (52.9%) developed tumor-specific immune responses, which lasted from 11 to 42 weeks. Twelve of 17 patients (70.6%) were progression free after 1 year. Treatment caused a dramatic accumulation of T cells in the tumor. The presence of CD4{sup +} T cells in the tumor positively correlated with tumor-specific immune responses that developed following combined therapy. Accumulation of myeloid-derived suppressor cells but not regulatory T cells negatively correlated with the development of tumor-specific immune responses. Experiments with {sup 111}In labeled DCs demonstrated that these antigen presenting cells need at least 48 h to start migrating from tumor site. Conclusions: Combination of intratumoral DC administration with EBRT was safe and resulted in induction of antitumor immune responses. This suggests that this therapy is promising and needs further testing in clinical trials design to assess clinical efficacy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A dose point kernel database using GATE Monte Carlo simulation toolkit for nuclear medicine applications: Comparison with other Monte Carlo codes

Purpose: GATE is a Monte Carlo simulation toolkit based on the Geant4 package, widely used for many medical physics applications, including SPECT and PET image simulation and more recently CT image simulation and patient dosimetry. The purpose of the current study was to calculate dose point kernels (DPKs) using GATE, compare them against reference data, and finally produce a complete dataset of the total DPKs for the most commonly used radionuclides in nuclear medicine. Methods: Patient-specific absorbed dose calculations can be carried out using Monte Carlo simulations. The latest version of GATE extends its applications to Radiotherapy and Dosimetry. Comparison of the proposed method for the generation of DPKs was performed for (a) monoenergetic electron sources, with energies ranging from 10 keV to 10 MeV, (b) beta emitting isotopes, e.g., {sup 177}Lu, {sup 90}Y, and {sup 32}P, and (c) gamma emitting isotopes, e.g., {sup 111}In, {sup 131}I, {sup 125}I, and {sup 99m}Tc. Point isotropic sources were simulated at the center of a sphere phantom, and the absorbed dose was stored in concentric spherical shells around the source. Evaluation was performed with already published studies for different Monte Carlo codes namely MCNP, EGS, FLUKA, ETRAN, GEPTS, and PENELOPE. A complete dataset of total DPKs was generated for water (equivalent to soft tissue), bone, and lung. This dataset takes into account all the major components of radiation interactions for the selected isotopes, including the absorbed dose from emitted electrons, photons, and all secondary particles generated from the electromagnetic interactions. Results: GATE comparison provided reliable results in all cases (monoenergetic electrons, beta emitting isotopes, and photon emitting isotopes). The observed differences between GATE and other codes are less than 10% and comparable to the discrepancies observed among other packages. The produced DPKs are in very good agreement with the already published data, which allowed us to produce a unique DPKs dataset using GATE. The dataset contains the total DPKs for {sup 67}Ga, {sup 68}Ga, {sup 90}Y, {sup 99m}Tc, {sup 111}In, {sup 123}I, {sup 124}I, {sup 125}I, {sup 131}I, {sup 153}Sm, {sup 177}Lu {sup 186}Re, and {sup 188}Re generated in water, bone, and lung. Conclusions: In this study, the authors have checked GATE's reliability for absorbed dose calculation when transporting different kind of particles, which indicates its robustness for dosimetry applications. A novel dataset of DPKs is provided, which can be applied in patient-specific dosimetry using analytical point kernel convolution algorithms.

61 RADIATION PROTECTION AND DOSIMETRY↗

PRESENT STATUS OF CHARGE-BREEDING IN KEKCB AT TRIAC

We report a recent experiment about the measurement of wall distribution of ions externally injected for charge-breeding in an electron cyclotron resonance (ECR) ion source. The ions, radioactive and singly charged {sup 111}In, were injected into the ECR ion source (ECRIS) for breeding their charge states at the Tokai Radioactive Ion Accelerator Complex (TRIAC). The residual radioactivity on the wall of the ECR plasma chamber of the source was measured, giving a two-dimensional distribution of the ions failed to be re-extracted during charge breeding. The distribution was decomposed, according to azimuthal symmetry, into three components, asymmetric, 120-degree symmetric, and isotropic ones, whose origins were qualitatively discussed for clarifying ion-losses in the course of charge breeding in ECRIS.

43 PARTICLE ACCELERATORS↗

Formation energy of oxygen vacancies in ZnO determined by investigating thermal behavior of Al and In impurities

Thermal behavior and interacting nature of 100-ppm Al and ∼100-ppt In impurities doped in zinc oxide (ZnO) were investigated by means of the time-differential perturbed angular correlation method with the {sup 111}In(→{sup 111}Cd) probe. Contrasting interactions between Al and In impurities were observed depending on different atmospheric conditions: (1) in air, Al and In impurities irreversibly associate with each other in the process of their thermal diffusion, but (2) in vacuum, their bound state formed in air dissociates by heat treatment at temperatures higher than 873 K, and this process is enhanced with increasing temperature. Detailed investigation of the thermal behavior of the impurities has revealed that the dissociation reaction is triggered by the formation of oxygen vacancies in the vicinity of the locally associated In-Al structure. A unique method to determine the activation energy of the oxygen-vacancy formation is presented with the estimated experimental value of E{sub a} = 0.72(6) eV.

36 MATERIALS SCIENCE↗

Three-dimensional radiobiological dosimetry of kidneys for treatment planning in peptide receptor radionuclide therapy

Purpose: Peptide receptor radionuclide therapy (PRRT) delivers high absorbed doses to kidneys and may lead to permanent nephropathy. Reliable dosimetry of kidneys is thus critical for safe and effective PRRT. The aim of this work was to assess the feasibility of planning PRRT based on 3D radiobiological dosimetry (3D-RD) in order to optimize both the amount of activity to administer and the fractionation scheme, while limiting the absorbed dose and the biological effective dose (BED) to the renal cortex. Methods: Planar and SPECT data were available for a patient examined with {sup 111}In-DTPA-octreotide at 0.5 (planar only), 4, 24, and 48 h post-injection. Absorbed dose and BED distributions were calculated for common therapeutic radionuclides, i.e., {sup 111}In, {sup 90}Y and {sup 177}Lu, using the 3D-RD methodology. Dose-volume histograms were computed and mean absorbed doses to kidneys, renal cortices, and medullae were compared with results obtained using the MIRD schema (S-values) with the multiregion kidney dosimetry model. Two different treatment planning approaches based on (1) the fixed absorbed dose to the cortex and (2) the fixed BED to the cortex were then considered to optimize the activity to administer by varying the number of fractions. Results: Mean absorbed doses calculated with 3D-RD were in good agreement with those obtained with S-value-based SPECT dosimetry for {sup 90}Y and {sup 177}Lu. Nevertheless, for {sup 111}In, differences of 14% and 22% were found for the whole kidneys and the cortex, respectively. Moreover, the authors found that planar-based dosimetry systematically underestimates the absorbed dose in comparison with SPECT-based methods, up to 32%. Regarding the 3D-RD-based treatment planning using a fixed BED constraint to the renal cortex, the optimal number of fractions was found to be 3 or 4, depending on the radionuclide administered and the value of the fixed BED. Cumulative activities obtained using the proposed simulated treatment planning are compatible with real activities administered to patients in PRRT. Conclusions: The 3D-RD treatment planning approach based on the fixed BED was found to be the method of choice for clinical implementation in PRRT by providing realistic activity to administer and number of cycles. While dividing the activity in several cycles is important to reduce renal toxicity, the clinical outcome of fractionated PRRT should be investigated in the future.

60 APPLIED LIFE SCIENCES↗

Dose received by occupationally exposed workers at a nuclear medicine department

Personal Dose Equivalent (PDE) values were determined for occupational exposed workers (OEW) at the Nuclear Medicine Department (NMD) of 'Instituto Nacional de Cancerologia' (INCan), Mexico, using TLD-100 thermoluminescent dosemeters. OEW at NMD, INCan make use of radiopharmaceuticals for diagnosis and treatment of diseases. Radionuclides associated to a pharmaceutical compound used at this Department are {sup 131}I, {sup 18}F, {sup 68}Ga, {sup 99m}Tc, {sup 111}In and {sup 11}C with main gamma emission energies between 140 and 511 keV. Dosemeter calibration was performed at the metrology department of 'Instituto Nacional de Investigaciones Nucleares' (ININ), Mexico. Every occupational worker used dark containers with three dosimeters which were replaced monthly for a total of 5 periods. Additionally, control dosemeters were also placed at a site free of radioactive sources in order to determine the background radiation. Results were adjusted to find PDE/day and estimating annual PDE values in the range between 2 mSv (background) and 9 mSv. The mean annual value is 3.51 mSv and the standard deviation SD is 0.78 mSv. Four of the 16 OEW received annual doses higher than the average +1 SD (4.29 mSv). Results depend on OEW daily activities and were consistent for each OEW for the 5 studied periods as well as with PDE values reported by the firm that performs the monthly service. All obtained values are well within the established annual OEW dose limit stated in the {sup R}eglamento General de Seguridad Radiologica{sup ,} Mexico (50 mSv), as well as within the lower limit recommended by the 'International Commission on Radiation Protection' (ICRP), report no.60 (20 mSv). These results verify the adequate compliance of the NMD at INCan, Mexico with the norms given by the national regulatory commission.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Prospective Trial of Intensity Modulated Radiation Therapy (IMRT) Incorporating a Simultaneous Integrated Boost for Prostate Cancer: Long-term Outcomes Compared With Standard Image Guided IMRT

Purpose: This report describes the long-term outcomes of a prospective trial of intensity modulated radiation therapy (IMRT), integrating a {sup 111}In capromab pendetide (ProstaScint) scan-directed simultaneous integrated boost (SIB) for localized prostate cancer. Methods and Materials: Seventy-one patients with T1N0M0 to T4N0M0 prostate cancer were enrolled, and their ProstaScint and pelvic computed tomography scans were coregistered for treatment planning. The entire prostate received 75.6 Gy in 42 fractions with IMRT, whereas regions of increased uptake on ProstaScint scans received 82 Gy as an SIB. Patients with intermediate- and high-risk disease also received 6 months and 12 months of adjuvant hormonal therapy, respectively. Results: The study enrolled 31 low-, 30 intermediate-, and 10 high-risk patients. The median follow-up was 120 months (range, 24-150 months). The 10-year biochemical control rates were 85% for the entire cohort and 84%, 84%, and 90% for patients with low-, intermediate-, and high-risk disease, respectively. The 10-year survival rate of the entire cohort was 69%. Pretreatment prostate-specific antigen level >10 ng/mL and boost volume of >10% of the prostate volume were significantly associated with poorer biochemical control and survival. The outcomes were compared with those of a cohort of 302 patients treated similarly but without the SIB and followed up for a median of 91 months (range, 6-138 months). The 5- and 10-year biochemical control rates were 86% and 61%, respectively, in patients without the SIB compared with 94% and 85%, respectively, in patients in this trial who received the SIB (P=.02). The cohort that received an SIB did not have increased toxicity. Conclusions: The described IMRT strategy, integrating multiple imaging modalities to administer 75.6 Gy to the entire prostate with a boost dose of 82 Gy, was feasible. The addition of the SIB was associated with greater biochemical control but not toxicity. Modern imaging technology can be used to locally intensify the dose to tumors and spare normal tissues, producing very favorable long-term biochemical disease control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Locally Targeted Delivery of a Micron-Size Radiation Therapy Source Using Temperature-Sensitive Hydrogel

Purpose: To propose a novel radiation therapy (RT) delivery modality: locally targeted delivery of micron-size RT sources by using temperature-sensitive hydrogel (RT-GEL) as an injectable vehicle. Methods and Materials: Hydrogel is a water-like liquid at room temperature but gels at body temperature. Two US Food and Drug Administration-approved polymers were synthesized. Indium-111 (In-111) was used as the radioactive RT-GEL source. The release characteristics of In-111 from polymerized RT-GEL were evaluated. The injectability and efficacy of RT-GEL delivery to human breast tumor were tested using animal models with control datasets of RT-saline injection. As proof-of-concept studies, a total of 6 nude mice were tested by injecting 4 million tumor cells into their upper backs after a week of acclimatization. Three mice were injected with RT-GEL and 3 with RT-saline. Single-photon emission computed tomography (SPECT) and CT scans were performed on each mouse at 0, 24, and 48 h after injection. The efficacy of RT-GEL was determined by comparison with that of the control datasets by measuring kidney In-111 accumulation (mean nCi/cc), representing the distant diffusion of In-111. Results: RT-GEL was successfully injected into the tumor by using a 30-gauge needle. No difficulties due to polymerization of hydrogel during injection and intratumoral pressure were observed during RT-GEL injection. No back flow occurred for either RT-GEL or RT-saline. The residual tumor activities of In-111 were 49% at 24 h (44% at 48 h, respectively) for RT-GEL and 29% (22%, respectively) for RT-saline. Fused SPECT-CT images of RT-saline showed considerable kidney accumulation of In-111 (2886%, 261%, and 262% of RT-GEL at 0, 24, and 48 h, respectively). Conclusions: RT-GEL was successfully injected and showed much higher residual tumor activity: 170% (200%, respectively), than that of RT-saline at 24 h (48 h, respectively) after injection with a minimal accumulation of In-111 to the kidneys. Preliminary data of RT-GEL as a delivery modality of a radiation source to a local tumor are promising.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extracorporeal adsorption therapy: A Method to improve targeted radiation delivered by radiometal-labeled monoclonal antibodies.

Many investigators have demonstrated the ability to treat hematologic malignancies with radiolabeled monoclonal antibodies targeting hematopoietic antigens such as anti-CD20 and anti-CD45. [1-5] Although the remission rates achieved with radioimmunotherapy (RIT) are relatively high, many patients subsequently relapse presumably due to suboptimal delivery of enough radiation to eradicate the malignancy. The dose-response of leukemia and lymphoma to radiation has been proven. Substantial amounts of radiation can be delivered by RIT if followed by hematopoietic cell transplantation to rescue the bone marrow from myeloablation.[ref] However, the maximum dose of RIT that can be used is still limited by toxicity to normal tissues affected by nonspecific delivery of radiation. Efforts to improve RIT focus on improving the therapeutic ratios of radiation in target versus non-target tissues by removing the fraction of radioisotope that fails to bind to target tissues and circulates freely in the bloodstream perfusing non-target tissues. Our group and others have explored several alternatives for removal of unbound circulating antibody. [refs] One such method, extracorporeal adsorption therapy (ECAT) consists of removing unbound antibody by a method similar to plasmapheresis after critical circulation time and distribution of antibody into target tissues have been achieved. Preclinical studies of ECAT in murine xenograft models demonstrated significant improvement in therapeutic ratios of radioactivity. Chen and colleagues demonstrated that a 2-hour ECAT procedure could remove 40 to 70% of the radioactivity from liver, lung and spleen. [ref] Although isotope concentration in the tumor was initially unaffected, a 50% decrease was noted approximately 36 hours after the procedure. This approach was also evaluated in a limited phase I pilot study of patients with refractory B-cell lymphoma. [ref] After radiographic confirmation of tumor localization of a test dose of anti-CD20 antibody labeled with indium-111 (111In), seven patients received RIT with anti-CD20 antibody labeled with indium-111 for biokinetics and dosimetry, and therapeutic doses of antibody labeled with yttrium-90 (90Y). Performing the ECAT procedure at a rate that such that one blood volume per hour were circulated for 3 hours, resulted in mean radioactivity depletion of 96% in whole blood, 49% in whole body 49%, 62% in the lungs and 40% in liver and kidneys. There was no sufficient data to determine whether there was an improvement in the relative delivery of radiation to the tumor compared to normal organs by performing ECAT, but pharmacokinetic modeling studies suggested a potential therapeutic advantage using this approach. [refs] To evaluate the potential therapeutic advantages of ECAT, we performed biodistribution studies in nonhuman primates comparing the therapeutic ratios of radiation delivered using this approach to those delivered by conventional RIT alone. In addition, we evaluated lutetium-177 (177Lu) as an alternative isotope to optimize the delivery of RIT by improving the therapeutic index (target to non-target ratio)

60 APPLIED LIFE SCIENCES↗

Simulation of multi-photon emission isotopes using time-resolved SimSET multiple photon history generator

Abstract-Multiple-photon emitters, such as In-111 or Se-75, have enormous potential in the field of nuclear medicine imaging. For example, Se-75 can be used to investigate the bile acid malabsorption and measure the bile acid pool loss. The simulation system for emission tomography (SimSET) is a well-known Monte Carlo simulation (MCS) code in nuclear medicine for its high computational efficiency. However, current SimSET cannot simulate these isotopes due to the lack of modeling of complex decay scheme and the time-dependent decay process. To extend the versatility of SimSET for simulation of those multi-photon emission isotopes, a time-resolved multiple photon history generator based on SimSET codes is developed in present study. For developing the time-resolved SimSET (trSimSET) with radionuclide decay process, the new MCS model introduce new features, including decay time information and photon time-of-flight information, into this new code. The half-life of energy states were tabulated from the Evaluated Nuclear Structure Data File (ENSDF) database. The MCS results indicate that the overall percent difference is less than 8.5% for all simulation trials as compared to GATE. To sum up, we demonstrated that time-resolved SimSET multiple photon history generator can have comparable accuracy with GATE and keeping better computational efficiency. The new MCS code is very useful to study the multi-photon imaging of novel isotopes that needs the simulation of lifetime and the time-of-fight measurements. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of quantitative imaging methods for organ activity and residence time estimation using a population of phantoms having realistic variations in anatomy and uptake

Estimating organ residence times is an essential part of patient-specific dosimetry for radioimmunotherapy (RIT). Quantitative imaging methods for RIT are often evaluated using a single physical or simulated phantom but are intended to be applied clinically where there is variability in patient anatomy, biodistribution, and biokinetics. To provide a more relevant evaluation, the authors have thus developed a population of phantoms with realistic variations in these factors and applied it to the evaluation of quantitative imaging methods both to find the best method and to demonstrate the effects of these variations. Using whole body scans and SPECT/CT images, organ shapes and time-activity curves of 111In ibritumomab tiuxetan were measured in dosimetrically important organs in seven patients undergoing a high dose therapy regimen. Based on these measurements, we created a 3D NURBS-based cardiac-torso (NCAT)-based phantom population. SPECT and planar data at realistic count levels were then simulated using previously validated Monte Carlo simulation tools. The projections from the population were used to evaluate the accuracy and variation in accuracy of residence time estimation methods that used a time series of SPECT and planar scans. Quantitative SPECT (QSPECT) reconstruction methods were used that compensated for attenuation, scatter, and the collimator-detector response. Planar images were processed with a conventional (CPlanar) method that used geometric mean attenuation and triple-energy window scatter compensation and a quantitative planar (QPlanar) processing method that used model-based compensation for image degrading effects. Residence times were estimated from activity estimates made at each of five time points. The authors also evaluated hybrid methods that used CPlanar or QPlanar time-activity curves rescaled to the activity estimated from a single QSPECT image. The methods were evaluated in terms of mean relative error and standard deviation of the relative error in the residence time estimates taken over the phantom population. The mean errors in the residence time estimates over all the organs were <9.9% (pure QSPECT), <13.2% (pure QPLanar), <7.2% (hybrid QPlanar/QSPECT), <19.2% (hybrid CPlanar/QSPECT), and 7%-159% (pure CPlanar). The standard deviations of the errors for all the organs over all the phantoms were <9.9%, <11.9%, <10.8%, <22.0%, and <107.9% for the same methods, respectively. The processing methods differed both in terms of their average accuracy and the variation of the accuracy over the population of phantoms, thus demonstrating the importance of using a phantom population in evaluating quantitative imaging methods. Hybrid CPlanar/QSPECT provided improved accuracy compared to pure CPlanar and required the addition of only a single SPECT acquisition. The QPlanar or hybrid QPlanar/QSPECT methods had mean errors and standard deviations of errors that approached those of pure QSPECT while providing simplified image acquisition protocols, and thus may be more clinically practical.

61 RADIATION PROTECTION AND DOSIMETRY↗