Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INCONEL 600”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Hot Corrosion Behavior of Ni20Cr Alloy in NaVO{sub 3} Molten Salt

The hot corrosion behavior of Ni20Cr alloy was evaluated in NaVO{sub 3} at temperatures of up to 700 °C and compared to Inconel 600. The performance of both the alloys was evaluated using electrochemical measurements, such as potentiodynamic polarization, linear polarization resistance, and electrochemical impedance spectroscopy measurements, as well as a cyclic corrosion test. The results show that the Ni20Cr alloy has better corrosion performance than the Inconel 600. The better performance of the Ni20Cr alloy was due to its ability to develop a stable protector oxide (Cr{sub 2}O{sub 3}) on its surface.

36 MATERIALS SCIENCE↗

NEET-AMM Final Technical Report on Laser Direct Manufacturing (LDM) for Nuclear Power Components

Final technical report summarizes the program progress and technical accomplishments of the Laser Direct Manufacturing (LDM) for Nuclear Power Components project. A series of experiments varying build process parameters (scan speed and laser power) were conducted at the outset to establish the optimal build conditions for each of the alloys. Fabrication was completed in collaboration with Quad City Manufacturing Laboratory (QCML). The density of all sample specimens was measured and compared to literature values. Optimal build process conditions giving fabricated part densities close to literature values were chosen for making mechanical test coupons. Test coupons whose principal axis is on the x-y plane (perpendicular to build direction) and on the z plane (parallel to build direction) were built and tested as part of the experimental build matrix to understand the impact of the anisotropic nature of the process.. Investigations are described 316L SS, Inconel 600, 718 and 800 and oxide dispersion strengthed 316L SS (Yttria) alloys.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High strength kiloampere Bi 2 Sr 2 CaCu 2 O x cables for high-field magnet applications

Multifilamentary Ag-sheathed Bi 2 Sr 2 CaCu 2 O x (Bi-2212) wire can carry sufficient critical current density J c for the development of powerful superconducting magnets. But, the range of its applications is limited by the low mechanical strength of the Ag/Bi-2212 strand. A potential solution is to cable Ag/Bi-2212 wire with high-strength materials that are compatible with the Bi-2212 heat treatment in an oxygen atmosphere. Past attempts have not always been successful, because the high-strength materials reacted with Bi-2212 wires, significantly reducing their J c . We examined the nature of reactions occurring when Ag/Bi-2212 wires are heat-treated in direct contact with several commonly used high-strength alloys and a new Fe-Cr-Al alloy. INCONEL X750 and INCONEL 600 resulted in significant J c loss, whereas Ni80-Cr caused little or no J c loss; however, all of them formed chromium oxide that subsequently reacted with silver, creating cracks in the silver sheath. We found that Fe-Cr-Al did not show significant reactions with Ag/Bi-2212 strands. Scanning electron microscopy (SEM) and energy dispersive x-ray (EDS) examinations revealed that the Fe-Cr-Al alloy benefits from the formation of a uniform, crack-free, continuous alumina layer on its surface that does not react with Ag and that helps minimize the Cu loss found with INCONEL X750 and INCONEL 600. We then fabricated prototype 6-around-1 cables with six Bi-2212 strands twisted and transposed around an Fe-Cr-Al alloy core coated with TiO 2 . After standard 1 bar melt processing, the cable retained 100% of the total current-carrying capability of its strands, and, after a 10 bar overpressure processing, the cable reached a total current of 1025 A at 4.2 K and 10 T. Tensile tests showed that Fe-Cr-Al becomes brittle after being cooled to 4.2 K, whereas INCONEL X750 remains ductile and retains a modulus of 183 GPa. Finally. we proposed new cable designs that take advantage of the chemical compatibility of Fe-Cr-Al and high strength of INCONEL X750 for various high-field magnet applications.

43 PARTICLE ACCELERATORS↗

Electrochemical impedance spectroscopy of metal alloys in the space transportation system launch environment

AC impedance measurements were performed to investigate the corrosion resistance of 18 alloys under conditions similar to the Space Transportation System (STS) launch environment. The alloys were: (1) zirconium 702; (2) Hastelloy C-22, C-276, C-4, and B-2; (3) Inconel 600 and 825; (4) Ferralium 255; (5) Inco Alloy G-3; (6) 20Cb-3; (7) SS 904L, 304LN, 316L, 317L, and 304L; (8) ES 2205; and (9) Monel 400. AC impedance data were gathered for each alloy at various immersion times in 3.55 percent NaCl-0.1N HCl. Polarization resistance values were obtained for the Nyguist plots at each immersion time using the EQUIVALENT CIRCUIT software package available with the 388 electrochemical impedance software. Hastelloy C-22 showed the highest overall values for polarization resistance while Monel 400 and Inconel 600 had the lowest overall values. There was good general correlation between the corrosion performance of the alloys at the beach corrosion testing site, and the expected rate of corrosion as predicted based on the polarization resistance values obtained. The data indicate that electrochemical impedance spectroscopy can be used to predict the corrosion performance of metal alloys.

Calle, Luz↗

Comparison of experimental and simulated critical heat flux tests with various cladding alloys: Sensitivity of iron-chromium-aluminum (FeCrAl) to heat transfer coefficients and material properties

In this paper we analyze the differences between previous transient critical heat flux (CHF) experiments using iron-chromium-aluminum (FeCrAl), Inconel 600, and stainless steel 316 (SS316) alloy test sections and best-estimate modeling results from widely-used nuclear engineering systems and subchannel analysis tools. FeCrAl is an Accident Tolerant Fuel (ATF) candidate cladding material. The thermal hydraulic performance and safety characteristics of FeCrAl are being evaluated to determine viability as a cladding material in Light Water Reactors (LWRs). In this study, the results of the CHF experiments conducted at atmospheric pressure and fixed inlet coolant temperature and mass flux are compared to models built in the fifth version of the Reactor Excursion and Leak Analysis Program (RELAP5-3D) and CTF, the modernized version of COBRA-TF developed by the Consortium for Advanced Simulation of LWRs (CASL). Results from RELAP5-3D and CTF showed differences from the experiments and from each other in predicting CHF. In the Inconel 600 case, both computational tools overpredicted CHF, which led to an underprediction in the tube outer surface temperature. In the SS316 and FeCrAl cases, CHF was underpredicted by the codes, leading to an overprediction of the tube outer surface temperature. To understand the discrepancies in CHF and post-CHF predictions, studies were performed using RELAP5-3D and RAVEN to determine the sensitivity of CHF and peak test section temperature, an analog to peak cladding temperature (PCT), to heat transfer coefficients, a CHF multiplier, and uncertainties in the thermal conductivity and volumetric heat capacity. We found that CHF depends most strongly on the CHF multiplier and thermophysical properties. A combination of these factors that produced the best match to the experiment based on CHF, PCT, and the total energy deposited into the tube was determined. The best match parameters were able to provide best-estimate predictions of the CHF and integral heat flux, but were still conservative when predicting the PCT. The best match set of parameters developed in this paper are intended only as a demonstration of an approach that could be applied in the future with a larger set of experiments to produce more accurate models of CHF and post-CHF behavior.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reactance simulation for the defects in steam generator tube with outside ferrite sludge

A magnetic sludge is partly produced around the tube sheet outside a steam generator due to stress and heat. The sludge with magnetite is one of the important factors affecting eddy current signals. It causes trouble for the safety of the steam generator tubes and is difficult to detect by conventional eddy current methods. A new type of probe is needed to detect the signals for the magnetic sludge. We designed a new U-type yoke which has two kinds of coils--a magnetizing coil and the other a detecting coil--and we simulated the signal induced by the ferromagnetic sludge in the Inconel 600 tube.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Properties of Structural Materials Used in LWR Vessels

High temperature material property data for structural materials used in existing Light Water Reactors (LWRs) are limited. Often, extrapolated values recommended in the literature differ significantly. To reduce uncertainties in predictions relying upon extrapolated data for LWR vessel and penetration materials, high temperature tests were completed on SA533 Grade B, Class 1 (SA533B1) low alloy steel, Stainless Steel 304 (SS304), and Inconel 600 using material property measurement systems available in the High Temperature Test Laboratory (HTTL) at the Idaho National Laboratory (INL). Properties measured include thermal expansion, specific heat capacity, and thermal diffusivity for temperatures up to 1200 °C. From these results, thermal conductivity and density were calculated. Results show that, in some cases, previously recommended values for these materials differ significantly from measured values at high temperatures.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Summary of thermocouple performance during advanced gas reactor fuel irradiation experiments in the advanced test reactor and out-of-pile thermocouple testing in support of such experiments

High temperature gas reactor experiments create unique challenges for thermocouple-based temperature measurements. As a result of the interaction with neutrons, the thermoelements of the thermocouples undergo transmutation, which produces a time-dependent change in composition and, as a consequence, a time-dependent drift of the thermocouple signal. This drift is particularly severe for high temperature platinum-rhodium thermocouples (Types S, R, and B) and tungsten-rhenium thermocouples (Type C). For lower temperature applications, previous experiences with Type K thermocouples in nuclear reactors have shown that they are affected by neutron irradiation only to a limited extent. Similarly, Type N thermocouples are expected to be only slightly affected by neutron fluence. Currently, the use of these nickel-based thermocouples is limited when the temperature exceeds 1000 deg. C due to drift related to phenomena other than nuclear irradiation. High rates of open-circuit failure are also typical. Over the past 10 years, three long-term Advanced Gas Reactor experiments have been conducted with measured temperatures ranging from 700 deg. C - 1200 deg. C. A variety of standard Type N and specialty thermocouple designs have been used in these experiments with mixed results. A brief summary of thermocouple performance in these experiments is provided. Most recently, out-of-pile testing has been conducted on a variety of Type N thermocouple designs at the following (nominal) temperatures and durations: 1150 deg. C and 1200 deg. C for 2,000 hours at each temperature, followed by 200 hours at 1250 deg. C and 200 hours at 1300 deg. C. The standard Type N design utilizes high purity, crushed MgO insulation and an Inconel 600 sheath. Several variations on the standard Type N design were tested, including a Haynes 214 alloy sheath, spinel (MgAl{sub 2}O{sub 4}) insulation instead of MgO, a customized sheath developed at the University of Cambridge, and finally a loose assembly thermocouple with hard-fired alumina insulation and a molybdenum sheath. The most current version of the High Temperature Irradiation Resistant Thermocouple, based on molybdenum/niobium alloys and developed at Idaho National Laboratory, was also tested. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Thermal Properties of Structural Materials Found in Light Water Reactor Vessels

High temperature material property data for structural materials used in existing Light Water Reactors (LWRs) are limited. Often, extrapolated values recommended in the literature differ significantly. To reduce such uncertainties, new data for SA533 Grade B, Class 1 (SA533B1) low alloy steel, Stainless Steel 304 (SS304), and Inconel 600, found in Light Water Reactor (LWR) vessels and penetrations, were acquired and tested using material property systems available at the High Temperature Test Laboratory (HTTL) at the Idaho National Laboratory (INL). Properties measured include thermal expansion, specific heat capacity, and thermal diffusivity for temperatures up to 1200 oC. From these results, thermal conductivity and density were calculated. Results show that, in some cases, previously recommended values for these material differ significantly from measured values at high temperatures. This is especially true for SA533B1, as previous data do not account for the phase transformation of this material between 740 oC and 840 oC.

36 MATERIALS SCIENCE↗

Microstructure, Processing, Performance Relationships for High Temperature Coatings

This work evaluates the suitability of iron aluminide coatings for use in high temperature fossil fuel combustion environments, such as boiler applications. The coatings are applied using High Velocity Oxy-Fuel (HVOF) thermal spray techniques. Iron aluminide coatings, with the nominal composition of Fe3Al, were applied to various high temperature structural materials (316 Stainless Steel, 9Cr-1Mo steel and Inconel 600) that typically lack inherent resistance to environmental degradation found in fossil fuel combustion atmospheres. Coating/substrate combinations were subjected to thermal cycling to evaluate the effect of HVOF parameters, coating thickness, substrate material and substrate surface roughness on the resistance to coating delamination and cracking. It was found that substrate surface roughness had a profound influence on the performance of a given substrate/coating system and that surface preparation techniques will need to be tailored to the specific substrate material. Also, higher particle velocity during HVOF thermal spray deposition of the iron aluminide coatings tended to result in better-performing coating/substrate systems with less delamination at the coating/substrate interface. Some combinations of HVOF parameters, coating thickness and substrate materials were found to perform extremely well even at temperatures up to 900oC. However, in some cases, substantial reactions at the interface were observed.

20 FOSSIL-FUELED POWER PLANTS↗

Shielding experiments by the JASMIN collaboration at Fermilab (II) - Radioactivity measurement induced by secondary particles from the anti-proton production target

The JASMIN Collaboration has performed an experiment to conduct measurements of nuclear reaction rates around the anti-proton production (Pbar) target at the Fermi National Accelerator Laboratory (FNAL). At the Pbar target station, the target, consisting an Inconel 600 cylinder, was irradiated by a 120 GeV/c proton beam from the FNAL Main Injector. The beam intensity was 3.6 x 10{sub 12} protons per second. Samples of Al, Nb, Cu, and Au were placed near the target to investigate the spatial and energy distribution of secondary particles emitted from it. After irradiation, the induced activities of the samples were measured by studying their gamma ray spectra using HPGe detectors. The production rates of 30 nuclides induced in Al, Nb, Cu, Au samples were obtained. These rates increase for samples placed in a forward (small angle) position relative to the target. The angular dependence of these reaction rates becomes larger for increasing threshold energy. These experimental results are compared with Monte Carlo calculations. The calculated results generally agree with the experimental results to within a factor of 2 to 3.

43 PARTICLE ACCELERATORS↗

Shielding experiments by the JASMIN Collaboration at Fermilab (II) - radioactivity measurement induced by secondary particles from the anti-proton production target

The JASMIN Collaboration has performed an experiment to conduct measurements of nuclear reaction rates around the anti-proton production (Pbar) target at the Fermi National Accelerator Laboratory (FNAL). At the Pbar target station, the target, consisting of an Inconel 600 cylinder, was irradiated by a 120 GeV/c proton beam from the FNAL Main Injector. The beam intensity was 3.6 x 10 12 protons per second. The samples of Al, Nb, Cu, and Au were placed near the target to investigate the spatial and energy distribution of secondary particles emitted from it. After irradiation, the induced activities of the samples were measured by studying their gamma ray spectra using HPGe detectors. The production rates of 30 nuclides induced in Al, Nb, Cu, Au samples were obtained. These rates increase for samples placed in a forward (small angle) position relative to the target. The angular dependence of these reaction rates becomes larger for increasing threshold energy. These experimental results are compared with Monte Carlo calculations. The calculated results generally agree with the experimental results to within a factor of 2 to 3.

36 MATERIALS SCIENCE↗

Long term out-of-pile thermocouple tests in conditions representative for nuclear gas-cooled high temperature reactors

During irradiation tests at high temperature, failure of commercial Inconel 600 sheathed thermocouples is commonly encountered. To understand and remedy this problem, out-of-pile tests were performed with thermocouples in carburizing atmospheres which can be assumed to be at least locally representative for High Temperature Reactors. The objective was to screen those thermocouples which would consecutively be used under irradiation. Two such screening tests have been performed with a set of thermocouples embedded in graphite (mainly conventional Type N thermocouples and thermocouples with innovative sheaths) in a dedicated furnace with helium flushing. Performance indicators such as thermal drift, insulation and loop resistance were monitored and compared to those from conventional Type N thermocouples. Several parameters were investigated: niobium sleeves, bending, thickness, sheath composition, temperature as well as the chemical environment. After the tests, Scanning Electron Microscopy (SEM) examinations were performed to analyze possible local damage in wires and in the sheath. The present paper describes the two experiments, summarizes results and outlines further work, in particular to further analyze the findings and to select suitable thermocouples for qualification under irradiation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Study of metal corrosion using ac impedance techniques in the STS launch environment

AC impedance measurements were performed to investigate the corrosion resistance of 19 alloys under conditions similar to the STS launch environment. The alloys were: Zirconium 702, Hastelloy C-22, Inconel 625, Hastelloy C-276, Hastelloy C-4, Inconel 600, 7Mo + N, Ferralium 255, Inco Alloy G-3, 20Cb-3, SS 904L, Inconel 825, SS 304LN, SS 316L, SS 317L, ES 2205, SS 304L, Hastelloy B-2, and Monel 400. AC impedance data were gathered for each alloy after one hour immersion time in each of the following three electrolyte solutions: 3.55 percent NaCl, 3.55 percent NaCl-0.1N HCl, and 3.55 percent NaCl-1.0N HCl. The data were analyzed qualitatively using the Nyquist plot and quantitatively using the Bode plot. Polarization resistance, Rp, values were obtained using the Bode plot. Zirconium 702 was the most corrosion resistant alloy in the three electrolytes. The ordering of the other alloys according the their resistance to corrosion varied as the concentration of hydrochloric acid in the electrolyte increased. The corrosion resistance of Zirconium 702 and Ferralium 255 increased as the concentration of hydrochloric acid in the electrolyte increased. The corrosion resistance of the other 17 alloys decreased as the concentration of the hyrdochloric acid in the electrolyte increased.

Calle, Luz M.↗

Electron emission from nickel-alloy surfaces in cesium vapor

The cesiated electron emission was measured for three candidate electrodes for use as collectors in thermionic converters. Nickel, Inconel 600 and Hastelloy were tested with a 412 K cesium reservoir. Peak emission from the alloys was found to be comparable to that from pure nickel. Both the Inconel and the Hastelloy samples had work functions of 1.64 eV at peak emission. The minimum work functions were estimated to be 1.37 eV at a probe temperature of 750 K for Inconel and 1.40 eV for Hastelloy at 665 K. The bare work function for both alloys is estimated to be approximately the same as for pure nickel, 4.8 eV.

Manda, M.↗

Electron emission from nickel-alloy surfaces in cesium vapor

An experimental apparatus and measurement techniques are described for measuring the thermionic emission from cesium-activated materials having adequate high-temperature properties such as creep strength and corrosion resistance, which might ultimately reduce the cost of thermionic converters. The electron emission characteristics are measured for nickel, Inconel 600, and Hastelloy X probes with a 412 K cesium reservoir. It is found that the nickel alloys exhibit a peak electron emission 1.4 to 2.1 times greater than pure nickel. Both the Inconel and the Hastelloy samples have work functions of 1.64 eV at peak emission. The minimum cesiated work functions are estimated to be 1.37 eV for Inconel at a probe temperature of 750 K and 1.4 eV for Hastelloy at a probe temperature of 665 K. The bare work functions for both alloys is estimated to be about the same as for pure nickel, 4.8 eV.

Manda, M.↗

Total Hemispherical Emissivity of Metals Applicable to Radiant Heat Testing

Total hemispherical emissivities are a commonly used property in radiative heat transfer analysis. Measurements made in the course of testing become far more useful to thermal analysts if they are compiled with a sufficient level of detail, and summarized in a manner that allows the most appropriate value or trend to be located quickly. This report collects emissivity measurements from recent years, made in the course of testing metallic surfaces at Sandia's Radiant Heat Test Facility, and compares them to a selection of previous summary documents. These measurements are organized by material type, surface finish, and degree of oxidation. The comparisons also consider the temperature dependence of total hemispherical emissivity. Materials considered include Inconel 600, SS304, 17-4PH SS, silicon carbide, and aluminum alloys. A limited selection of high-temperature paints and other surface coatings are also considered. Recommendations are made for frequency of measurements and level of detail in reporting emissivities in future test series. A more limited scope is recommended for the use of high-temperature paints at Sandia's Radiant Heat Test Facility; pre-oxidation of Inconel and stainless steel surfaces is preferred in many circumstances.

36 MATERIALS SCIENCE↗

Liquid level sensing for harsh environment applications using distributed fiber optic temperature measurements

This work demonstrates the measurement of liquid level from spatially distributed temperature measurements using optical frequency domain reflectometry. The goal of this work is to provide initial evidence for a liquid level sensor concept that could be applied in harsh environments such as those with: conductive, flammable, or other chemically aggressive media; electromagnetic interference; high temperatures (up to ~1000 °C); and neutron/gamma radiation. The sensor concept includes fiber optic sensors, along with an insulated heater wire assembled inside a protective Inconel 600 sheath. When the heater is not powered, the sensor provides spatially distributed temperature measurements along the length of the fiber. When the heater is powered, the difference in heat transfer in the liquid vs. vapor sections leads to a higher fiber temperature at locations above the liquid/vapor interface. The initial demonstration described in this work tested the sensor in a tank of water that was drained in increments of 2.5 cm. A model for determining liquid level from the distributed temperature measurements was developed that resulted in an accuracy of ±0.5 cm. Finally, the paper addresses potential effects of axial conduction through the sensor sheath, as well as ways to limit these effects to avoid “smearing” of what would otherwise be a step change in temperature at the liquid/vapor interface.

42 ENGINEERING↗