Engineering PapersSearch

SEARCH · Engineering Papers

Results for “INCIDENT RAY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

On the Alignment and Focusing of the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS)

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a NASA sounding rocket instrument that is designed to observe soft X-ray emissions from 24 - 6.0 A (0.5 - 2.0 keV energies) in the solar atmosphere. For the rst time, high-temperature, low-emission plasma will be observed directly with 5 arcsecond spatial resolution and 22 mA spectral resolution. The unique optical design consists of a Wolter - I telescope and a 3-optic grazing- incidence spectrometer. The spectrometer utilizes a nite conjugate mirror pair and a blazed planar, varied line spaced grating, which is directly printed on a silicon substrate using e-beam lithography. The grating design is being nalized and the grating will be fabricated by the Massachusetts Institute of Technology (MIT) and Izentis LLC. Marshall Space Flight Center (MSFC) is producing the nickel replicated telescope and spectrometer mirrors using the same facilities and techniques as those developed for the ART-XC and FOXSI mirrors. The Smithsonian Astrophysical Observatory (SAO) will mount and align the optical sub-assemblies based on previous experience with similar instruments, such as the Hinode X-Ray Telescope (XRT). The telescope and spectrometer assembly will be aligned in visible light through the implementation of a theodolite and reference mirrors, in addition to the centroid detector assembly (CDA) { a device designed to align the AXAF-I nested mirrors. Focusing of the telescope and spectrometer will be achieved using the X-ray source in the Stray Light Facility (SLF) at MSFC. We present results from an alignment sensitivity analysis performed on the on the system and we also discuss the method for aligning and focusing MaGIXS.

solar

Zemax Modeling of a Self-aligned Focusing Schlieren System with Simulated Compressible Flow

A self-aligned focusing schlieren system is simulated in the ANSYS Zemax OpticStudio software environment. The model uses a custom scatter-defining dynamic link library on the retroreflective background in order to scatter rays in the direction of the incident ray rather than the specular ray. Simulated compressible flow refractive index fields are imported into Zemax by use of the grid gradient object and a workaround to the maximum point limit is introduced. The Ronchi ruling is built as a high resolution bitmap image in MATLAB and set in Zemax as a slide object allowing the bitmap image to either transmit or terminate rays at each line pair. The Zemax simulations are compared to computational numerical schlieren and experimental conventional, path-integrated schlieren results from a hypersonic stagnation point injection flow configuration and an experimental image of a shock wave from a laser-induced breakdown. In the stagnation point injection simulations, the Zemax schlieren images capture complex flow features such as the Mach disk, shear layers, contact surface, and bow shock well, but contains long, curved features (striations) between the model and the bow shock that are not present in the synthetic schlieren image from the CFD or the experimental image. The image from Zemax of the spark-induced shock wave captures the shape and curvature of the shock but appears blurry due to grid discretization in the computational data.

Nicholas A Mejia

Results from a Grazing Incidence X-Ray Interferometer

A prototype grazing incidence interferometer has been built and tested at EUV and X-ray wavelengths using a 120 meter long vacuum test facility at Marshall Space Flight Center. We describe the design and construction of the interferometer, the EUV and x-ray sources, the detector systems, and compare the interferometric fringe measurements with theoretical predictions. We also describe the next-generation grazing incidence system which is designed to provide laboratory demonstration of key technologies that will be needed for a space-based x-ray interferometer.

Joy, Marshall K.

Preliminary Results from the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS)

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a sounding rocket mission that aims to observe the soft x-ray solar spectrum (0.6 – 2.5 nm) with both spatial and spectral resolution over a substantial field of view. This wavelength range has several high temperature and abundance diagnostics that can be used to assist in diagnosing the coronal heating mechanism. MaGIXS launched from White Sands Missile Range on July 30, 2021 and successfully observed the Sun through a 4’ x 33’ effective slot, producing ``overlappograms’’, where the spatial and spectral information are overlapped and must be unfolded. In this presentation, I will report on the MaGIXS launch and data collection and provide preliminary analysis of MaGIXS data.

Amy Winebarger

Preliminary Results from the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS)

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a sounding rocket mission that aims to observe the soft x-ray solar spectrum (0.6 – 2.5 nm) with both spatial and spectral resolution over a substantial field of view. This wavelength range has several high temperature and abundance diagnostics that can be used to assist in diagnosing the coronal heating mechanism. MaGIXS launched from White Sands Missile Range on July 30, 2021 and successfully observed the Sun through a 4’ x 33’ effective slot, producing ``overlappograms’’, where the spatial and spectral information are overlapped and must be unfolded. In this presentation, I will report on the MaGIXS launch and data collection and provide preliminary analysis of MaGIXS data.

Amy Winebarger

On the Development of the Marshall Grazing Incidence X-ray Spectrograph (MaGIXS) Mirrors

The Marshall Grazing Incidence X-ray Spectrograph (MaGIXS) is a sounding rocket experiment that will obtain spatially resolved soft X-ray spectra of the solar corona from 0.5 - 2 keV. The optical system comprises a Wolter-I telescope mirror, a slit spectrograph, and a CCD camera. The spectrograph has a finite conjugate paraboloid pair, which re-images the slit, and a varied line-space planar reflection grating. Both the Wolter-I mirror and paraboloid pair are being fabricated at the NASA Marshall Space Flight Center (MSFC), using nickel replication. The MaGIXS mirror mandrels have been diamond turned, polished, and have yielded a set of engineering mirrors. Unlike other grazing incidence instruments, such as FOXSI, ART-XC, and IXPE, the MaGIXS prescriptions have large departure from a cone. This property exacerbates challenges with conventional lap polishing techniques and interferometric metrology. Here we discuss the progression of the optical surfaces of the mandrels through lap polishing, X-ray data from the replicated shells obtained in the MSFC Stray Light Facility (SLF), and our transition to using the ZEEKO computer numerical controlled (CNC) polisher for figure correction.

Champey, Patrick

The Third Flight of the Marshall Grazing Incidence X-Ray Spectrometer (MaGIXS-3)

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is the first X-ray slitless imaging spectrograph sounding rocket instrument designed to observe spectrally dispersed soft X-ray images of the solar corona over a wide field-of-view. During the first flight of MaGIXS (MaGIXS-1), occurred on 30 July 2021, several emission lines from coronal structures including X-ray bright points were observed. Further, MaGIXS-1 analysis also demonstrated the successful inversion of overlappograms using robust unfolding algorithms. Given the demonstrated success of MaGIXS-1, the second flight of the instrument with a simplified optical design, MaGIXS-2, is scheduled for 2024 to observe high temperature diagnostic emission lines. Results from MaGIXS-1 discovered dominant missing emission lines near 15A, arising from relatively cool plasma that peaks around 2 MK. This wavelength region hosts several closely spaced satellite lines of Fe XVII, Fe XVI and Fe XV ions, which are expected to be enhanced at lower temperatures and are currently unmodeled in the CHIANTI atomic database. This wavelength region offers one of the most unique diagnostics to measure electron temperature, as well as signatures of equilibrium state of the plasma in active regions, which has not been studied so far. The goal of MaGIXS-3 mission is the to determine coronal heating parameters, such as the spatial and temporal properties of coronal heating events, by measuring discriminating observations, such as electron temperature, effective temperature, density, abundance, and departures from thermal equilibrium of the plasma, by observing the Sun in the SXR wavelength range. To meet this goal, the MaGIXS instrument will be upgraded with a new X-ray telescope mirror that will provide higher spatial and spectral resolution and throughput, allowing for spectral lines to be observed at the relevant spatial and temporal scales. In addition, MaGIXS-3 will also carry The Resolving Inversion Context X-ray Spectrometer (TRICXS), a high dispersion Bragg crystal spectrometer to spectrally resolve the lines near 14.9 to 15.9A, critical to unlock the full diagnostic potential of this wavelength range. Here we will present the preliminary concept design of MaGIXS-3 and discuss the potential observations.

X-ray Imaging

Variable magnification variable dispersion glancing incidence imaging x ray spectroscopic telescope

A variable magnification variable dispersion glancing incidence x ray spectroscopic telescope capable of multiple high spatial revolution imaging at precise spectral lines of solar and stellar x ray and extreme ultraviolet radiation sources includes a primary optical system which focuses the incoming radiation to a primary focus. Two or more rotatable carriers each providing a different magnification are positioned behind the primary focus at an inclination to the optical axis, each carrier carrying a series of ellipsoidal diffraction grating mirrors each having a concave surface on which the gratings are ruled and coated with a multilayer coating to reflect by diffraction a different desired wavelength. The diffraction grating mirrors of both carriers are segments of ellipsoids having a common first focus coincident with the primary focus. A contoured detector such as an x ray sensitive photographic film is positioned at the second respective focus of each diffraction grating so that each grating may reflect the image at the first focus to the detector at the second focus. The carriers are selectively rotated to position a selected mirror for receiving radiation from the primary optical system, and at least the first carrier may be withdrawn from the path of the radiation to permit a selected grating on the second carrier to receive radiation.

Hoover, Richard

Design of a normal incidence multilayer imaging X-ray microscope

Normal incidence multilayer Cassegrain X-ray telescopes were flown on the Stanford/MSFC Rocket X-ray Spectroheliograph. These instruments produced high spatial resolution images of the sun and conclusively demonstrated that doubly reflecting multilayer X-ray optical systems are feasible. The images indicated that aplanatic imaging soft X-ray/EUV microscopes should be achievable using multilayer optics technology. A doubly reflecting normal incidence multilayer imaging X-ray microscope based on the Schwarzschild configuration has been designed. The design of the microscope and the results of the optical system ray trace analysis are discussed. High resolution aplanatic imaging X-ray microscopes using normal incidence multilayer X-ray mirrors should have many important applications in advanced X-ray astronomical instrumentation, X-ray lithography, biological, biomedical, metallurgical, and laser fusion research.

Shealy, David L.

Loop models of low coronal structures observed by the Normal Incidence X-Ray Telescope (NIXT)

The X-ray pictures obtained with the Normal Incidence X-Ray Telescope (NIXT), apart from the ubiquitous coronal loops well known from previous X-ray observations, show a new and peculiar morphology: in many active regions there are wide and apparently low-lying areas of intense emission which resemble H alpha plages. By means of hydrostatic models of coronal arches, we analyze the distribution of temperature, density, emission measure, and plasma emissivity in the spectral band to which NIXT is sensitive, and we show that the above morphology can be explained by the characteristics of high pressure loops having a thin region of high surface brightness at the base. We therefore propose that this finding might help to identify high-pressure X-ray emitting coronal regions in NIXT images, and it is in principle applicable to any imaging instrument which has high sensitivity to 10(exp 4) - 10(exp 6) K plasma within a narrow coronal-temperature passband. As a more general result of this study, we propose that the comparison of NIXT observations with models of stationary loops might provide a new diagnostic: the determination of the loop plasma pressure from measurements of brightness distribution along the loop.

Peres, G.

The Next Generation Marshall Grazing Incidence X-Ray Spectrometer (MaGIXS) Sounding Rocket Experiments

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a sounding rocket experiment that carries an X-ray slitless imaging spectrograph to observe spectrally dispersed soft X-ray (SXR) images of the solar corona over a wide field-of-view. The first flight of MaGIXS occurred on 30 July 2021, during which several emission lines from coronal structures including X-ray bright points were observed. Analysis of MaGIXS-1 data demonstrated the application of new inversion techniques and opened a new arena of inverting complex spectroheliogram data, which has spatial-spectral information overlapped. The second flight of MaGIXS, with a simplified optical design, is scheduled for 2024. The goal of MaGIXS-2 is to observe high temperature diagnostic emission lines within an active region core. MaGIXS-1 discovered dominant missing emission lines near 15Å wavelength region, which hosts several closely spaced satellite lines of Fe XVII, Fe XVI, and Fe XV ions, arising from relatively cool plasma that peaks near 2MK. These lines are expected to be enhanced at lower temperatures and offers one of the most unique diagnostics to measure electron temperature, as well as signatures of equilibrium state of the plasma in active regions, which has not been studied so far. The science goal of the third sounding rocket flight of MaGIXS is to determine coronal heating parameters, such as the spatial and temporal properties of coronal heating events, by measuring discriminating observations, such as electron temperature, effective temperature, density, abundance, and departures from thermal equilibrium of the plasma, by observing the Sun in the SXR wavelength range. For this, the MaGIXS instrument will be upgraded with a new X-ray telescope mirror that will provide higher spatial and spectral resolution and throughput, allowing for spectral lines to be observed at the relevant spatial and temporal scales. In addition, MaGIXS-3 will also carry The Resolving Inversion Context X-ray Spectrometer (TRICXS), a high dispersion Bragg crystal spectrometer to spectrally resolve the lines near 15Å, critical to unlock the full diagnostic potential of this wavelength range. Here we will present the preliminary concept design of MaGIXS-3 and discuss the potential observations.

X-ray Imaging

Performance analysis of grazing incidence imaging systems

An exact expression relating the coordinates of a point on the incident ray, a point of reflection from an arbitrary surface, and a point on the reflected ray is derived. The exact relation is then specialized for the case of grazing incidence, and first order and third order systematic analyses are carried out for a single reflective surface and then for a combination of two surfaces. The third order treatment yields a complete set of primary aberrations for single element and two element systems. The importance of a judicious choice for a coordinate system in showing field curvature to clearly be the predominant aberration for a two element system is discussed. The validity of the theory is verified through comparisons with the exact ray trace results for the case of the telescope.

Winkler, C. E.

Focal surfaces of offset dual-reflector antennas

An analytical technique is described for finding the best focal surfaces for offset-fed dual-reflector antennas. A ray tracing procedure traces the loci of rays incident on the main reflector onto a plane or 'screen' situated perpendicular to a central ray of the antenna system. Given, then, by computer graphics, the best feed locations for azimuth and elevation plane patterns, an aperture diffraction method is used which can compute the sidelobe levels and beamwidths resulting from aperture phase errors on scanned or multibeam patterns. High-magnification Cassegrain or Gregorian antennas, with tilt angles optimised according to Japanese criteria, produce excellent radiation diagrams many beamwidths from the central, unaberrated pattern direction.

Sletten, C. J.

Marshall Grazing Incidence X-Ray Spectrometer (MaGIXS)

Outline: Scientific motivation for MaGIXS (Marshall Grazing Incidence X-ray Spectrometer) - Demonstrate sensitivity of MaGIXS to determine high temperature plasma; Instrument design - Challenges involved; Instrument status - alignment and calibration.

Athiray, P. S.

A Normal Incidence X-ray Telescope (NIXT) Sounding Rocket Payload

During the past year the changeover from the normal incidence X ray telescope (NIXT) program to the new TXI sounding rocket program was completed. The NIXT effort, aimed at evaluating the viability of the remaining portions of the NIXT hardware and design has been finished and the portions of the NIXT which are viable and flightworthy, such as filters, mirror mounting hardware, electronic and telemetry interface systems, are now part of the new rocket payload. The backup NIXT multilayer-coated X ray telescope and its mounting hardware have been completely fabricated and are being stored for possible future use in the TXI rocket. The h-alpha camera design is being utilized in the TXI program for real-time pointing verification and control via telemetry. Two papers, summarizing scientific results from the NIXT rocket program were published this year.

Golub, Leon

GeV gamma-ray astronomy telescopes with high angular resolution

Gamma-ray telescopes flown on satellites have poor angular resolution with typical point source error circles of a few square degrees. It is shown that a major improvement in angular resolution for the detection of gamma-rays in the GeV region can be obtained with a single crystal as converter. The electron produced by a gamma ray incident at a small angle to a major crystal axis or plane is captured into channeling and radiates gamma rays. The channeling radiation and the electron-positron pair can be detected and yield point source locations with a precision of 5 arcseconds at 10 GeV. This is an improvement of three orders of magnitude on the angular precision of telescopes sensitive to gamma-rays above 50 MeV flown on Satellites.

Mcbreen, B.