Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

IMS R and D program at Canada customs

Over the last few years, Revenue Canada, in collaboration with Barringer Instruments Limited, has been involved in the development of a field-usable ion mobility spectrometer (IMS) for the detection of drugs of abuse. This work has culminated in the manufacturing and commercialization by Barringer of the Ionscan 350 instruments, now in use by various law enforcement agencies worldwide. Although IMS exhibits a very strong and distinctive response toward some nitrogen containing drugs, e.g., cocaine, like all separation techniques it has inherent limitations, namely moderate resolution and low chemical signal to noise ratio which may affect the reliability of IMS-based drug detectors. A program is in place at the Laboratory and Scientific Services Directorate (LSSD) to investigate the applicability of various digital signal processing (DSP) techniques to IMS output signals. The application of neural network techniques to overlapping IMS peaks is presented.

Pilon, Pierre↗

Data collection in IMS: It's not as easy as it looks

Data collection in Ion Mobility Spectrometry (IMS) is not as easy an endeavor as it appears. Despite the advent of high speed personal computers and fast analog-to-digital converters (ADC's), care must be taken to ensure that reliable data are obtained in a timely fashion. This is especially true in hyphenated techniques, e.g. GC-IMS, where the amount of data increases dramatically when gas chromatography-ion mobility spectrometry (GC-IMS) data is being collected. Using the Graseby GC-IMS, with a gate repetition rate of 33 Hz, it is theoretically possible to collect 33 spectra per second. This collection rate is not realistically obtained due to a number of factors. Among these factors are inaccuracy of the timing signal from the IMS, the necessity to store the data, disk input/output limitations, disk operating system limitations, and program overhead. Taking these factors into account, we have achieved a data collection rate of 20 spectra per second. This paper will describe these problems, demonstrate the practical effects these problems present, and present methods for minimizing these effects.

Davis, Dennis M.↗

Using STAX data to predict IMS radioxenon concentrations

The noble gas collection and measurement stations in the International Monitoring System (IMS) are heavily influenced by releases from medical isotope production facilities. The ability to reliably model the movement of radioxenon from the points of release to these IMS samplers has improved enough that a routine aspect of the analysis of IMS radioxenon data should be the prediction of the effect of releases from civilian nuclear facilities on the sample concentrations. In this work, predicted concentrations at IMS noble gas systems in Germany and Sweden based on measured releases from Institute for Radioelements (IRE) in Belgium and atmospheric transport modeling for a four-month period are presented and discussed.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Development of Intelligent Monitoring System (IMS) Modules for the Aquistore CO 2 Storage Project

The monitoring data generated at a CO 2 storage site can quickly result in large amounts of data, often requiring significant labor- and time-intensive efforts to process and analyze before being able to make operational decisions. Implementing an intelligent monitoring system (IMS) can reduce the associated data-processing and analysis costs, which can thereby improve the efficiency of the monitoring process and enable real-time operational decision-making. The Energy & Environmental Research Center (EERC) has completed a 3-year project focused on developing an IMS comprising new workflows, algorithms, and a user interface for the automation and integration of geologic carbon dioxide (CO 2 ) storage site-monitoring and simulation data. The design for the IMS was based on using injection and monitoring data acquired from Aquistore, an operating CO 2 storage project. Managed by the Petroleum Technology Research Centre, the Aquistore Project is injecting CO 2 captured from SaskPower’s coal-fired Boundary Dam Power Station into a deep saline formation for geologic storage. Using data from the Aquistore Project provided a real-world basis to develop an IMS.

47 OTHER INSTRUMENTATION↗

The structure and dynamics of the magnetosphere: Progress in the IMS

Knowledge of the magnetosphere before the International Magnetospheric Study (IMS) is reviewed, and advances due to IMS are outlined. Post IMS studies are summarized. The GEOS spacecraft continuously monitored the state of the interior of the magnetosphere. The ISEE-1 and 2 satellites measured the velocities of magnetospheric boundaries. The ISEE-3 monitored solar wind input to the magnetosphere. The spacecraft provided data on magnetopause thickness, reconnection, electric field configuration, and plasma currents. Post IMS projects examined the ionosphere, auroras, and the deep geomagnetic tail.

Russell, C. T.↗

Solvation of Ucl (6)**2- Anionic Complex By Mebu (3) N+, Bume (2) Im+, And Bumeim+ Cations

The complexes [MeBu{sub 3}N]{sub 2}[UCl{sub 6}] and [BuMe{sub 2}Im]{sub 2}[UCl{sub 6}] were characterized in the solid state and in solution of [MeBu{sub 3}N][Tf{sub 2}N], [BuMe{sub 2}Im][Tf{sub 2}N], and [BuMeIm][Tf{sub 2}N] room-temperature ionic liquids using single-crystal XRD, EXAFS, electrochemistry, UV-visible absorption spectroscopy, and NMR. In the solid state and in solution, the existence of hydrogen bonding between the UCl{sub 6}{sup 2-} complex and the ionic liquid cations was revealed by these techniques. The MeBu{sub 3}N{sup +} cation interacts with UCl{sub 6}{sup 2-} via the protons on the {alpha}-carbon atoms of nitrogen. The protons of the imidazolium ring account for the interaction between the BuMe{sub 2}Im{sup +} cation and the UCl{sub 6}{sup 2-} anion. For the BuMeIm{sup +} cation the major interaction was confirmed between the most acidic proton on C(2) and the chlorides of UCl{sub 6}{sup 2-}. The experimental results also show that the intensity of the interaction between the UCl{sub 6}{sup 2-} anion and the cation varies with the ionic liquid cation in the following order: MeBu{sub 3}N{sup +} {approx} BuMe{sub 2}Im{sup +} << BuMeIm{sup +}.

08 HYDROGEN↗

Secrecy Analysis of Uplink IM-OFDMA Systems in the Presence of IQ Imbalance

This article introduces the secrecy analysis of the index modulation-based orthogonal frequency division multiple access (IM-OFDMA) schemes by considering the in-phase and quadrature imbalance (IQI) presence at the users' RF front ends. In particular, by assuming the existence of an eavesdropper, the secrecy performance of the considered uplink multiple-access system is investigated through the strictly positive secrecy capacity and secrecy outage probability, and closed-form expressions are derived for both quantities. Moreover, the secrecy performance is conducted regarding IQI compensation based on a preamble-based estimation method. Further, analysis of the impact of the different parameters of IM-OFDMA, IQI, and estimation method is included via analytical and simulation-based results. In conclusion, the results reveal that IM-OFDMA is more reliable in secrecy performance than OFDMA, regardless of whether IQI is present. Also, IQI compensation can lead to a better secrecy performance compared to the case of no IQI.

42 ENGINEERING↗

Dual-Phase Malicious User Detection Scheme for IM-OFDMA Systems Using IQ Imbalance

Physical-layer security techniques have contributed to the achievement of various security objectives in an efficient and lightweight manner. Thus, these techniques have been widely considered for limited-resource networks such as Internet of Things networks. Among the different security objectives, malicious user detection by exploiting physical-layer parameters has demonstrated efficient performance. In this work, malicious user detection in the recently proposed index modulation-based orthogonal frequency division multiple access (IM-OFDMA) is addressed. The proposed malicious user detection scheme exploits the hardware impairments, especially the in-phase and quadrature imbalance parameters, for both legitimate and malicious users to design a dual-phase efficient detection scheme. The proposed scheme accounts for the special characteristics of IM-OFDMA transmission that are different from other multiple-access techniques. The performance of the proposed scheme was evaluated considering detection probability and false alarm probability performance metrics. Moreover, closed-form expressions of these metrics were derived for both phases and were validated by Monte Carlo simulation results under different configurations of IM-OFDMA systems.

Alaca, Ozgur [ORNL] (ORCID:0000000153713758)↗

The Characterization of Laser Ablation Patterns and a New Definition of Resolution in Matrix Assisted Laser Desorption Ionization Imaging Mass Spectrometry (MALDI-IMS)

Matrix assisted laser desorption ionization imaging mass spectrometry (MALDI-IMS) is a technique that has seen a sharp rise in both use and development. Despite this rapid adoption, there have been few thorough investigations into the actual physical mechanisms that underlie the acquisition of IMS images. We therefore set out to characterize the effect of IMS laser ablation patterns on the surface of a sample. We also concluded that the governing factors that control spatial resolution have not been correctly defined and therefore propose a new definition of resolution. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IM-16: A new microporous germanosilicate with a novel framework topology containing d4r and mtw composite building units

The synthesis and the structure of IM-16 a new germanosilicate with a novel zeolitic topology prepared hydrothermally with the ionic liquid 3-ethyl-1-methyl-3H-imidazol-1-ium as the organic structure-directing agent are reported. The structure of calcined and partially rehydrated IM-16 of chemical formula |(H{sub 2}O){sub 0.16}|[Si{sub 3.47}Ge{sub 2.53}O{sub 12}] was solved from powder XRD data in space group Cmcm with a=15.0861(2) A, b=17.7719(3) A, c=19.9764(3) A, V=5355.84(12) A{sup 3} (Z=16). This new zeolite framework type contains 10-MRs channels and may be described from the d4r and mtw composite building units. - Graphical abstract: The synthesis and the structure of IM-16 a new germanosilicate with a novel zeolitic topology prepared hydrothermally with the ionic liquid 3-ethyl-1-methyl-3H-imidazol-1-ium as the organic structure-directing agent are reported. This new zeolite framework type contains 10-MRs channels and may be described from the d4r and mtw composite building units.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accumulation of Large Ion Populations with High Ion Densities and Effects Due to Space Charge in Traveling Wave-Based Structures for Lossless Ion Manipulations (SLIM) IMS-MS

The accumulation of very large ion populations in traveling wave (TW)-based Structures for Lossless ion Manipulations (SLIM) has been studied to better understand aspects of ‘in-SLIM’ ion accumulation, and particularly its use in conjunction with ion mobility spectrometry (IMS). A linear SLIM ion path was implemented that had a ‘gate’ for blocking and accumulating ions for arbitrary time periods. Removing the gate potential caused ions to exit and the spatial distributions of accumulated ions were examined. The ion populations for a set of peptides were observed to increase with increased accumulation times until space change effects became significant, after which the peptide precursor ion populations decreased due to growing space charge-related ion activation, reactions, and losses. Ions closest to the gate were preferentially activated, and increasingly so with added storage times, TW amplitude, and the size of the total ion population. For analytical applications, we found that relatively weak TWs in the accumulation/storage region should be utilized to prevent or minimize ion losses and/or ion heating effects that can also lead to fragmentation. Our results further indicate that an accumulation region close to the SLIM entrance is advantageous for both speeding accumulation, minimizing ion heating, and avoiding ion population profiles that result in IMS peak tailing. Importantly, space charge-driven separations were observed for large populations of accumulated species and attributed to the opposing effects of space charge and the TW. In these separations, ion species form distributions or peaks, sometimes moving against the TW, and ordered in the SLIM based on their mobilities. Such separations may offer utility for ion pre-fractionation of ions and increasing the dynamic range measurements, increasing the resolving power of IMS separations by decreasing peak widths for accumulated ion populations, and other purposes benefitting from separations of extremely large ion populations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LC-IMS-MS Feature Finder. Detecting Multidimensional Liquid Chromatography, Ion Mobility, and Mass Spectrometry Features in Complex Datasets

We introduce a command line software application LC-IMS-MS Feature Finder that searches for molecular ion signatures in multidimensional liquid chromatography-ion mobility spectrometry-mass spectrometry (LC-IMS-MS) data by clustering deisotoped peaks with similar monoisotopic mass, charge state, LC elution time, and ion mobility drift time values. The software application includes an algorithm for detecting and quantifying co-eluting chemical species, including species that exist in multiple conformations that may have been separated in the IMS dimension.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Information management system study results. Volume 1: IMS study results

The information management system (IMS) special emphasis task was performed as an adjunct to the modular space station study, with the objective of providing extended depth of analysis and design in selected key areas of the information management system. Specific objectives included: (1) in-depth studies of IMS requirements and design approaches; (2) design and fabricate breadboard hardware for demonstration and verification of design concepts; (3) provide a technological base to identify potential design problems and influence long range planning (4) develop hardware and techniques to permit long duration, low cost, manned space operations; (5) support SR&T areas where techniques or equipment are considered inadequate; and (6) permit an overall understanding of the IMS as an integrated component of the space station.

Source record↗

Current status of IMS plasma wave research

The present investigation is concerned with a review of the status of magnetospheric plasma wave science as a result of the International Magnetospheric Study (IMS). The presence of an international effort has supported the development and completion of the numerous magnetospheric science spacecraft launched during the IMS, including GEOS, ISEE, and EXOS B. Ground-based VLF observations are considered along with coordinated ground-based and satellite observations. During the IMS, plasma wave research using satellite data has covered a wide range of subjects. Attention is given to magnetospheric electrostatic emissions, magnetospheric electromagnetic plasma waves, continuum radiation, auroral kilometric radiation, auroral zone plasma waves, plasma waves in the magnetosheath and near the mangetopause, and plasma waves at the bow shock.

Anderson, R. R.↗

Direct analysis of organic priority pollutants by IMS

Many routine methods for monitoring of trace amounts of atmospheric organic pollutants consist of several steps. Typical steps are: (1) collection of the air sample; (2) trapping of organics from the sample; (3) extraction of the trapped organics; and (4) identification of the organics in the extract by GC (gas chromatography), HPLC (High Performance Liquid Chromatography), or MS (Mass Spectrometry). These methods are often cumbersome and time consuming. A simple and fast method for monitoring atmospheric organics using an IMS (Ion Mobility Spectrometer) is proposed. This method has a short sampling time and does not require extraction of the organics since the sample is placed directly in the IMS. The purpose of this study was to determine the responses in the IMS to organic 'priority pollutants'. Priority pollutants including representative polycyclic aromatic hydrocarbons (PAHs), phthalates, phenols, chlorinated pesticides, and polychlorinated biphenyls (PCB's) were analyzed in both the positive and negative detection mode at ambient atmospheric pressure. Detection mode and amount detected are presented.

Giam, C. S.↗

Analytical/Operational Requirements for the In Situ Chemical Analysis of Cometary and Planetary Environments Using GC-IMS

Exobiology flight experiments require highly sensitive instrumentation for the in situ analysis of the volatile chemical species that occur in the atmospheres and surfaces of various bodies within the solar system. The complex mixtures encountered place a heavy burden on the analytical instrumentation to detect and identify all species present. The minimal resources available onboard for such missions mandate that the instruments provide maximum analytical capabilities with minimal requirements of volume, weight and consumables. The miniCIDEX instrument was developed for the chemical analysis of a cemetery environment. It combined a Gas Chromatograph (GC) with a helium based Ion Mobility Spectrometer (IMS) to fulfill the analytical requirements of a cemetery exobiology mission: universal response; ppb sensitivity; low mass, volume and consumable MiniCIDEX is now a candidate for the chemical analysis instrument of a Titan Aero-rover Mission. The complexity of the analyses will be similar to the comet application with a heavier emphasis on organic molecules. Because the Titan Aero-Rover will be a balloon powered rover, much more attention is placed on the total mass of the instrument package. The GC will likely be a Micro-Electro-Mechanical-System (MEMS) design, smaller than the initial miniCIDEX GC by a factor of ten (with a similar reduction in consumable use). Similar miniaturization of the helium-based IMS will be necessary while maintaining the analytical capabilities. The two mission applications, the analytical requirements, and the evolution of the IMS design to accommodate these requirements will be presented.

Kojiro, Daniel R.↗

Plasma IMS Composition Measurements for Europa and the Other Galilean Moons

NASA and ESA are planning the joint Europa Jupiter System Mission (EJSM) to the Jupiter system with specific emphasis to Europa and Ganymede, respectively. The Japanese Space Agency is also planning an orbiter mission to explore Jupiter's magnetosphere and the Galilean satellites. For NASA's Jupiter Europa Orbiter (JEO) we are developing the 3D Ion Mass Spectrometer (IMS) with two main goals which can also be applied to the other Galilean moons, 1) measure the plasma interaction between Europa and Jupiter's magnetosphere and 2) infer the 4 pi surface composition to trace elemental and significant isotopic levels. The first goal supports the magnetometer (MAG) measurements, primarily directed at detection of Europa's sub-surface ocean, while the second gives information about transfer of material between the Galilean moons, and between the moon surfaces and subsurface layers putatively including oceans. The measurement of the interactions for all the Galilean moons can be used to trace the in situ ion measurements of pickup ions back to either Europa's or Ganymede's surface from the respectively orbiting spacecraft. The IMS instrument, being developed under NASA's Astrobiology Instrument Development Program, would maximally achieve plasma measurement requirements for JEO and EJSM while moving forward our knowledge of Jupiter system composition and source processes to far higher levels than previously envisaged. The composition of the global surfaces of Europa and Ganymede can be inferred from the measurement of ejected neutrals and pick-up ions using at minimum an in situ payload including MAG and IMS also fully capable of meeting Level 1 mission requirements for ocean detection and survey. Elemental and isotopic analysis of potentially extruded oceanic materials at the moon surfaces would further support the ocean objectives. These measurements should be made from a polar orbiting spacecraft about Europa or Ganymede at height 100 km. The ejecta produced by sputtering of the surfaces of Europa and Ganymede has been shown to be representative of the surface composition. Level 2 science on surface geology and composition can then be further enhanced by addition of the following: 3D Ion Neutral Mass Spectrometer (INNS), 3D plasma electron spectrometer (ELS), and hot plasma energetic particle instrument. The measurement approach is to alternate between times measuring pickup ions and times measuring plasma and magnetic field parameters along the spacecraft trajectory. By measuring the pickup ion energy, arrival direction and mass-per-charge, the ion can be traced back along the ejection trajectory to the approximate area of origin if the 3-D electric field and magnetic field are known. In situ observations of plasma flow velocities and vector magnetic fields can be used to determine the local convective electric field (E = -VXB) along the spacecraft trajectory. By combining this information with models of the magnetospheric interaction with Europa, one can generate 3D maps of the electric and magnetic field and compute the trajectories of the pickup ions back to the surface or exospheric points of origin. In the case of Ganymede there is the additional complexity of its own internal dipole magnetic field, while Io's volcanic activity introduces the complexity of a highly structured denser atmosphere. Callisto with its less globally extended exosphere will have a simpler interaction than for Europa (i.e., more like our moon). We will discuss these differences in light of the above proposed technique. Finally, the INNS observations and neutral exosphere models are needed to estimate production rates of pickup ions. The hot plasma measurements are needed to correct for sputtering rates which can be time dependent and electron plasma observations for electron impact ionization rates. Instrument characteristics, field-of-view requirements, modes of operation and effects of radiation on instrument functionality will be discussed.

Sittler, Edward↗

Direct Imaging of Extra-Solar Planets in Star Forming Regions: Lessons Learned from a False Positive Around IM Lup

Context. Most exoplanet imagers consist of ground-based adaptive optics coronagraphic cameras which are currently limited in contrast, sensitivity and astrometric precision, but advantageously observe in the near-infrared window (1 5 m). Because of these practical limitations, our current observational aim at detecting and characterizing planets puts heavy constraints on target selection, observing strategies, data reduction, and follow-up. Most surveys so far have thus targeted young systems (1 100 Myr) to catch the putative remnant thermal radiation of giant planets, which peaks in the near-infrared. They also favor systems in the solar neighborhood (d less than 80 pc), which eases angular resolution requirements but also ensures a good knowledge of the distance and proper motion, which are critical to secure the planet status, and enable subsequent characterization. Aims. Because of their youth, it is very tempting to target the nearby star forming regions, which are typically twice as far as the bulk of objects usually combed for planets by direct imaging. Probing these interesting reservoirs sets additional constraints that we review in this paper by presenting the planet search that we initiated in 2008 around the disk-bearing T Tauri star IM Lup, which is part of the Lupus star forming region (140-190 pc). Methods. We show and discuss why age determination, the choice of evolutionary model for both the central star and the planet, precise knowledge of the host star proper motion, relative or absolute (between different instruments) astrometric accuracy (including plate scale calibration), and patience are the key ingredients for exoplanet searches around more distant young stars. Results. Unfortunately, most of the time, precision and perseverance are not paying off: we discovered a candidate companion around IM Lup in 2008, which we report here to be an unbound background object. We nevertheless review in details the lessons learned from our endeavor, and additionally present the best detection limits ever calculated for IM Lup. We also accessorily report on the successful use of innovative data reduction techniques, such as the damped-LOCI and iterative roll subtraction.

D Mawet↗