Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

CFM-ID 4.0: More Accurate ESI MS/MS Spectral Prediction and Compound Identification

In the field of metabolomics, mass spectrometry (MS) is the method most commonly used for identifying and annotating metabolites. As this typically involves matching a given MS spectrum against an experimentally acquired reference spectral library, this approach is limited by the coverage and size of such libraries (which typically number in the thousands). These experimental libraries can be greatly extended by predicting the MS spectra of known chemical structures (which number in the millions) to create computational reference spectral libraries. To facilitate the generation of predicted spectral reference libraries we developed CFM-ID, a computer program that can accurately predict ESI-MS/MS spectrum for a given compound structure. CFM-ID is one of the best-performing methods for compound-to-mass-spectrum prediction, and also one of the top tools for in silico mass-spectrum-to-compound identification. This work improves CFM-ID’s ability to predict ESI-MS/MS spectra from compounds by: (1) learning parameters from features based on the molecular topology, (2) adding a new approach to ring cleavage that models such cleavage as a sequence of simple chemical bond dissociations and (3) expanding its hand-written rule-based predictor to cover more chemical classes, including acylcarnitines, acylcholines, flavonols, flavones, flavanones, and flavonoid glycosides. We demonstrate that this new version of CFM-ID (version 4.0) is significantly more accurate than previous CFM-ID versions, in terms of both EI-MS/MS spectral prediction and compound identification. CFM-ID 4.0 is available at http://cfmid4.wishartlab.com/ as a webservice and docker images can be downloaded at https://hub.docker.com/r/wishartlab/cfmid

Wang, Fei↗

Structures of Class Id Ribonucleotide Reductase Catalytic Subunits Reveal a Minimal Architecture for Deoxynucleotide Biosynthesis

Class I ribonucleotide reductases (RNRs) share a common mechanism of nucleotide reduction in a catalytic α subunit. All RNRs initiate catalysis with a thiyl radical, generated in class I enzymes by a metallocofactor in a separate β subunit. Class Id RNRs use a simple mechanism of cofactor activation involving oxidation of a Mn II 2 cluster by free superoxide to yield a metal-based Mn III Mn IV oxidant. This simple cofactor assembly pathway suggests that class Id RNRs may be representative of the evolutionary precursors to more complex class Ia–c enzymes. X-ray crystal structures of two class Id α proteins from Flavobacterium johnsoniae (Fj) and Actinobacillus ureae (Au) reveal that this subunit is distinctly small. The enzyme completely lacks common N-terminal ATP-cone allosteric motifs that regulate overall activity, a process that normally occurs by dATP-induced formation of inhibitory quaternary structures to prevent productive β subunit association. Class Id RNR activity is insensitive to dATP in the Fj and Au enzymes evaluated here, as expected. However, the class Id α protein from Fj adopts higher-order structures, detected crystallographically and in solution. The Au enzyme does not exhibit these quaternary forms. Our study reveals structural similarity between bacterial class Id and eukaryotic class Ia α subunits in conservation of an internal auxiliary domain. Overall, our findings with the Fj enzyme illustrate that nucleotide-independent higher-order quaternary structures can form in simple RNRs with truncated or missing allosteric motifs.

59 BASIC BIOLOGICAL SCIENCES↗

Beamline CSX (23-ID, EPU 49): 25 mA Commissioning Radiation Survey Report

A comprehensive radiological survey of the Beamline CSX (23-ID-1) was conducted on March 27, 2015 in accordance with the Beamline CSX (23-ID, EPU 49) Radiation Survey Plan [1]. The purpose of the survey is to verify the shielding integrity of the 23-ID beamline First Optics Enclosure (FOE) and downstream beam pipe. At the time of this comprehensive survey, 23-ID-2 beamline was still undergoing technical commissioning and therefore Section II “23 ID-2 FOE, exclusion zone and downstream pipe” could not be completed. During the surveys the stored beam current varied between 21.43 mA and 23.51 mA, the 23-ID straight section vacuum was around 0.44 ntorr, and front-end slits were open near their hard stop limits.

36 MATERIALS SCIENCE↗

Evaluating lightweight unsupervised online IDS for masquerade attacks in CAN

Vehicular controller area networks (CANs) are susceptible to masquerade attacks by malicious adversaries. In masquerade attacks, adversaries silence a targeted ID and then send malicious frames with forged content at the expected timing of benign frames. As masquerade attacks could seriously harm vehicle functionality and are the stealthiest attacks to detect in CAN, recent work has devoted attention to compare frameworks for detecting masquerade attacks in CAN. However, most existing works report offline evaluations using CAN logs already collected using simulations that do not comply with the domain’s real-time constraints. Here we contribute to advance the state of the art by presenting a comparative evaluation of four different non-deep learning (DL)-based unsupervised online intrusion detection systems (IDS) for masquerade attacks in CAN. Our approach differs from existing comparative evaluations in that we analyze the effect of controlling streaming data conditions in a sliding window setting. In doing so, we use realistic masquerade attacks being replayed from the ROAD dataset. We show that although evaluated IDS are not effective at detecting every attack type, the method that relies on detecting changes in the hierarchical structure of clusters of time series produces the best results at the expense of higher computational overhead. We discuss limitations, open challenges, and how the evaluated methods can be used for practical unsupervised online CAN IDS for masquerade attacks.

Anomaly detection↗

Toward operation of series IDs at BL43LXU of SPring-8

This paper discusses two issues relating to using 3 small gap insertion devices in series at BL43LXU of SPring-8 to make a uniquely powerful source in the 15-26 keV region of the x-ray spectrum. The issues discussed are (1) damage to the covers of the downstream IDs by radiation from the upstream IDs and (2) proper steering of the electron beam to get the best photon beam properties. After tests in several configurations, including one where an ID was run without an impedance-reducing cover, the damage issue was solved by installing a distributed absorber in the most downstream ID. The steering issues were mostly resolved by the introduction of appropriate corrector magnets and feedback. The paper is written from the viewpoint of an interested beamline scientist impressed with the cooperation of different groups to make a source for new science possible.

43 PARTICLE ACCELERATORS↗

FUSARIUM-ID v.3.0: An Updated, Downloadable Resource for Fusarium Species Identification

Species within Fusarium are of global agricultural, medical, and food/feed safety concern and have been extensively characterized. However, accurate identification of species is challenging and usually requires DNA sequence data. FUSARIUM-ID ( http://isolate.fusariumdb.org/blast.php ) is a publicly available database designed to support the identification of Fusarium species using sequences of multiple phylogenetically informative loci, especially the highly informative ~680-bp 5' portion of the translation elongation factor 1-alpha (TEF1) gene that has been adopted as the primary barcoding locus in the genus. However, FUSARIUM-ID v.1.0 and 2.0 had several limitations, including inconsistent metadata annotation for the archived sequences and poor representation of some species complexes and marker loci. Here, we present FUSARIUM-ID v.3.0, which provides the following improvements: (i) additional and updated annotation of metadata for isolates associated with each sequence, (ii) expanded taxon representation in the TEF1 sequence database, (iii) availability of the sequence database as a downloadable file to enable local BLAST queries, and (iv) a tutorial file for users to perform local BLAST searches using either freely available software, such as SequenceServer, BLAST+ executable in the command line, and Galaxy, or the proprietary Geneious software. FUSARIUM-ID will be updated on a regular basis by archiving sequences of TEF1 and other loci from newly identified species and greater in-depth sampling of currently recognized species.

Plant Sciences↗

Defining the safe current limit for opening ID photon shutter

The NSLS-II storage ring is protected from possible damage from insertion devices (IDs) synchrotron radiation by a dedicated active interlock system (AIS). It monitors electron beam position and angle and triggers beam drop if beam orbit exceeds the boundaries of pre-calculated active interlock envelope (AIE). The beamlines (BL) and beamline frontends (FE) are designed under assumption that the electron beam is interlocked within the AIE. For historic reasons the AIS engages the ID active interlock (AI-ID) at any non-zero beam current whenever the ID photon shutter (IDPS) is getting opened. Such arrangement creates major inconveniences for BLs commissioning. Apparently there is some IDPS safe current limit (SCL) under which the IDPS can be opened without interlocking the e-beam. The goal of this paper is to find such limit.

43 PARTICLE ACCELERATORS↗

Time-Resolved Research at the Advanced Photon Source Beamline 7-ID

The Sector 7 undulator beamline (7-ID) of the Advanced Photon Source (APS) is dedicated to time-resolved x-ray research and is capable of ultrafast measurements on the order of 100 ps. Beamline 7-ID has a laser laboratory featuring a Ti:Sapphire system (average power of 2.5W, pulse duration <50 fs, repetition rate 1-5 kHz) that can be synchronized to the bunch pattern of the storage ring. The laser is deliverable to x-ray enclosures, which contain diffractometers, as well as motorized optical tables for table-top experiments. Beamline 7-ID has a single APS Undulator A and uses a diamond (111) double-crystal monochromator, providing good energy resolution over a range of 6-24 keV. Available optics include Kirkpatrick-Baez (KB) mirrors to microfocus the x-ray beam. A variety of time-resolved diffraction and spectroscopy research is available at 7-ID, with experiments being done in the atomic, molecular, optical, chemistry, and solid state (bulk and surface) fields.

43 PARTICLE ACCELERATORS↗

Id-1 gene and gene products as therapeutic targets for treatment of breast cancer and other types of carcinoma

A method for treatment of breast cancer and other types of cancer. The method comprises targeting and modulating Id-1 gene expression, if any, for the Id-1 gene, or gene products in breast or other epithelial cancers in a patient by delivering products that modulate Id-1 gene expression. When expressed, Id-1 gene is a prognostic indicator that cancer cells are invasive and metastatic.

60 APPLIED LIFE SCIENCES↗

Idaho National Laboratory Supervisory Control and Data Acquisition Intrusion Detection System (SCADA IDS)

Current Intrusion Detection System (IDS) technology is not suited to be widely deployed inside a Supervisory, Control and Data Acquisition (SCADA) environment. Anomaly- and signature-based IDS technologies have developed methods to cover information technology-based networks activity and protocols effectively. However, these IDS technologies do not include the fine protocol granularity required to ensure network security inside an environment with weak protocols lacking authentication and encryption. By implementing a more specific and more intelligent packet inspection mechanism, tailored traffic flow analysis, and unique packet tampering detection, IDS technology developed specifically for SCADA environments can be deployed with confidence in detecting malicious activity.

42 ENGINEERING↗

ID-SERS Based Reference Method for Quantification of Large Biomolecules on a Single Chip

Accuracy and precision of quantitative SERS results have been significantly increased by applying a method based on the so-called isotope-dilution (ID) principle. In this ID-SERS approach, an isotopically labeled analogue of the target molecule (isotopologue) is spiked to the sample at a known concentration. Due to the slight difference in their molar masses, some Raman bands of the heavier isotopologue are red-shifted with respect to the same signals resulting from the unlabelled compound. As a result, spectra evaluation is reduced to the determination of intensity ratios rather than absolute intensities, and the unknown quantity of the analyte can be calculated from the known quantity of the standard. This procedure is of particular interest in the development of highly accurate reference procedures for metrology in chemistry. Because the sample is spiked prior to any further treatment, potential loss of material or matrix effects would equally affect both isotopologues, without influencing the final result. The method has been successfully applied for quantifying small diagnostic marker molecules like creatinine at their relevant serum concentration levels using silver colloids as SERS substrates. Now, the ID-SERS approach has been realized as a 'one-chip' approach using 'Bio-chips' made of intrinsically grown spherical silver nanoparticles with gaps less than 10 nm in between (Fig. 1). In addition, the scope of the method has been extended to larger biomolecules like peptides which will be shown using the example of the human growth-hormone (hGH) peptide T12 at physiologically relevant serum concentration levels (Fig. 2). Further developments towards the quantification of full proteins will also be reported.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Uncertainty evaluation in reference material characterization by double isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS)

Double isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) is one of the most important measurement methods in the establishment of measurement standards for inorganic analysis. However, there is still no good consensus on approaches for uncertainty evaluation in double ID-ICP-MS. Particularly, approaches to treating the instrumental isotopic fractionation (IIF) phenomenon and correlation between uncertainty sources are diverse and often unclear in the literature. Here, an approach for uncertainty evaluation in double ID-ICP-MS measurements is described. Using three certified reference materials (CRMs), it is shown that the IIF effects cancel out and should not be included in the uncertainty budget. Further, a consistent way of considering correlated sources of uncertainty to prevent double counting of uncertainties is described in detail along with an example of measuring the mass fraction of magnesium in an oyster powder CRM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards a CAN IDS Based on a Neural Network Data Field Predictor

Modern vehicles contain a few controller area networks (CANs), which allow scores of on-board electronic control units (ECUs) to communicate messages critical to vehicle functions and driver safety. CAN provides a lightweight and reliable broadcast protocol but is bereft of security features. As evidenced by many recent research works, CAN exploits are possible both remotely and with direct access, fueling a growing CAN intrusion detection system (IDS) body of research. A challenge for pioneering vehicle-agnostic IDSs is that passenger vehicles' CAN message encodings are proprietary, defined and held secret by original equipment manufacturers (OEMs). Targeting detection of next-generation attacks, in which messages are sent from the expected ECU at the expected time but with malicious content, researchers are now seeking to leverage "CAN data models'', which predict future CAN messages and use prediction error to identify anomalous, hopefully malicious CAN messages. Yet, current works model CAN signals post-translation, i.e., after applying OEM-donated or reverse-engineered translations from raw data. We present initial IDS results testing deep neural networks used to predict CAN data at the bit level, targeting IDS capabilities that avoiding reverse engineering proprietary encodings. Our results suggest the method is promising for data with signals exhibiting dependence on previous or concurrent inputs.

Pawelec, Krzysztof↗

eBPF Community ID Calculation

The code titled “eBPF Community ID Calculation” allows easy correlation of monitoring logs with existing network forensics logs on high-performance computing (HPC) systems. This code implements the Community ID Flow Hashing standard to calculate community ID Flow identifiers. These identifiers will be used to correlate host forensics logs with network forensics logs. The correlation provides valuable insight and the ability to easily pivot between disparate data sources. The computer code removes the libpcap dependency from the code base.

Maerz, StefanA↗

R&D100: IC ID

Supply chain security to detect, deter, and prevent the counterfeiting of networked and stand-alone integrated circuits (ICs) is critical to cyber security. Sandia National Laboratory researchers have developed IC ID to leverage Physically Unclonable Functions (PUFs) and strong cryptographic authentication to create a unique fingerprint for each integrated circuit. IC ID assures the authenticity of ICs to prevent tampering or malicious substitution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NLTE and LTE Lick indices for red giants from [Fe/H] 0.0 TO −6.0 at SDSS and IDS spectral resolution

We investigate the dependence of the complete system of 22 Lick indices on overall metallicity scaled from solar abundances, [M/H], from the solar value, 0.0, down to the extremely metal-poor (XMP) value of −6.0, for late-type giant stars (MK luminosity class III, logg=2.0) of MK spectral class late-K to late-F (3750<T{sub eff}<6500 K) of the type that are detected as “fossils” of early galaxy formation in the Galactic halo and in extra-galactic structures. Our investigation is based on synthetic index values, I, derived from atmospheric models and synthetic spectra computed with PHOENIX in Local Thermodynamic Equilibrium (LTE) and Non-LTE (NLTE), where the synthetic spectra have been convolved to the spectral resolution, R, of both IDS and SDSS (and LAMOST) spectroscopy. We identify nine indices, that we designate “Lick-XMP,” that remain both detectable and significantly [M/H]-dependent down to [M/H] values of at least ∼−5.0, and down to [M/H] ∼ −6.0 in five cases, while also remaining well-behaved (single-valued as a function of [M/H] and positive in linear units). For these nine indices, we study the dependence of I on NLTE effects, and on spectral resolution. For our LTE I values for spectra of SDSS resolution, we present the fitted polynomial coefficients, C{sub n}, from multi-variate linear regression for I with terms up to third order in the independent variable pairs (T{sub eff}, [M/H] ) and (V−K, [M/H]), and compare them to the fitted C{sub n} values of Worthey et al. at IDS spectral resolution. For this fitted I data-set we present tables of LTE partial derivatives, ((∂I)/(∂T{sub eff}))|{sub [M/H]}, ((∂I)/(∂[M/H]))|{sub T{sub e{sub f{sub f}}}}, ((∂I)/(∂(V−K)))|{sub [M/H]}, and ((∂I)/(∂[M/H]))|{sub (V−K)}, that can be used to infer the relation between a given difference, ΔI, and a difference ΔT{sub eff} or Δ(V−K), or a difference Δ[M/H], while the other parameters are held fixed. For Fe-dominated Lick indices, the effect of NLTE is to generally weaken the value of I at any given T{sub eff} and [M/H] values. As an example of the impact on stellar parameter estimation, for late-type giants of inferred T{sub eff}≳4200 K, an Fe-dominated I value computed in LTE that is too strong might be compensated for by inferring a T{sub eff} value that is too large.

79 ASTRONOMY AND ASTROPHYSICS↗

In situ X-ray data collection and structure phasing of protein crystals at Structural Biology Center 19-ID

A prototype of a 96-well plate scanner for in situ data collection has been developed at the Structural Biology Center (SBC) beamline 19-ID, located at the Advanced Photon Source, USA. The applicability of this instrument for protein crystal diffraction screening and data collection at ambient temperature has been demonstrated. Several different protein crystals, including selenium-labeled, were used for data collection and successful SAD phasing. Without the common procedure of crystal handling and subsequent cryo-cooling for data collection at T = 100 K, crystals in a crystallization buffer show remarkably low mosaicity (<0.1°) until deterioration by radiation damage occurs. Data presented here show that cryo-cooling can cause some unexpected structural changes. Based on the results of this study, the integration of the plate scanner into the 19-ID end-station with automated controls is being prepared. With improvement of hardware and software, in situ data collection will become available for the SBC user program including remote access.

59 BASIC BIOLOGICAL SCIENCES↗

Time-Based CAN IDS Paper Results Code

Modern vehicles are complex cyber-physical systems made of hundreds of electronic control units (ECUs) that communicate over controller area networks (CANs). This inherited complexity has expanded the CAN attack surface which is vulnerable to message injection attacks. These injections change the overall timing characteristics of messages on the bus, and thus, to detect these malicious messages, time-based intrusion detection systems (IDSs) have been proposed. However, time-based IDSs are usually trained and tested on low-fidelity datasets with unrealistic, labeled attacks. This makes difficult the task of evaluating, comparing, and validating IDSs. Here we detail and benchmark four time-based IDSs against the newly published ROAD dataset, the first open CAN IDS dataset with real (non-simulated) stealthy attacks with physically verified effects. We found that methods that perform hypothesis testing by explicitly estimating message timing distributions have lower performance than methods that seek anomalies in a distribution related statistic. In particular, these “distribution-agnostic” based methods outperform “distribution-based” methods by at least 55% in area under the precision-recall curve (AUC-PR). Our results expand the body of knowledge of CAN time-based IDSs by providing details of these methods and reporting their results when tested on datasets with real advanced attacks. Finally, we develop an after-market plug-in detector using lightweight hardware, which can be used to deploy the best performing IDS method on nearly any vehicle.

Moriano, Pablo [Oak Ridge National Lab. (ORNL), Oa↗