Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Beamline CHX (11-ID, IVU 20): 25 mA Commissioning Radiation Survey Report

A comprehensive radiological survey of the Beamline CHX (11-ID, In-Vacuum Undulator) was conducted on March 12 and 13, 2015 in accordance with the Beamline CHX (11-ID) Radiation Survey Plan [1]. Some initial setup of the beamline and front end slits was needed and completed on March 09, 2015. The purpose of the survey was to verify the shielding integrity of the two 11-ID beamline enclosures (11-ID-A and 11-ID-B) and transport pipe between 11-ID-A and 11-ID-B.

36 MATERIALS SCIENCE↗

Possibility of splitting APS dipoles to make more ID straights.

Recently we were asked by Ercan Alp if it would be possible to use three dipoles in an APS sector to make a second ID beamline possible, much as was done for the APSx3 design. We've looked at this to see what might be possible without making too many changes to the ring. Ideally, we'd like to simply replace the one dipole with two shorter dipoles with an insertion device in the middle. Of course, we'd like to make the ID as long as possible, subject to limits on dipole strength, accelerator optics, and emittance. We used elegant [3] to match an insertion device consisting of two sectors. The second (BM) dipole of the first sector was split at the 1/8th point in terms of both angle and length. A zero length drift space was inserted that could then be stretched to create room for an ID. To simplify matters somewhat at this stage, we constrained the length of the two dipoles plus the drift to equal the original dipole length. I.e., we ignored for now the difference between arc and straight length. Our desire is to make the drift space as long as possible. If we limit the dipole field B to 2T, then the total length of the dipoles must be greater than L{sub min} = H{theta}/B, where H = 23.35Tm is the rigidity and {theta} = {pi}/40-0.001 is the total angle. L{sub min} is therefore 0.91 m, and hence the drift space can at most be 2.15 m. At least one, perhaps both, of the short dipoles will end up in a high-dispersion region, which will lead to emittance growth. Hence, we didn't want to drive the length too far and decided to limit it to 2 m, approximately the same as in the APSx3 lattice. Hence, as in that lattice we should be able to accommodate a 1-m-long insertion device. In addition to stretching the drift space, we allowed all twenty quadrupoles in the sectors to vary. Initial constraints included less than 20% deviation in lattice functions at the middle ID straight and less than 0.001% deviation in the final ID straight (to get a good match to the rest of the ring). We found the dispersion slope at the middle ID was quite hard to match, and made this a relatively loose constraint. We also had to increase the tolerance on changes in the horizontal beta function at the middle ID from 20 to 30%. A constraint was also placed on the effective emittance to make it as small as possible. Figure 1 shows the lattice functions for the two sectors. The magnet-to-magnet distance between the split dipoles is 1.97 m, slightly short of the 2 m mark. The first dipole is 0.17 m long with a field of 1.35 T, while the second dipole is 0.92 m long with a field of 1.73 T. The effective emittance assuming we formed a ring from such sectors is 4.95 nm. Hence, if we add N such modules to a ring with all other sectors being normal (3.13 nm effective emittance), the expected emittance is 9.9N + (40-2N)3.13/40 (1). If we want to limit the emittance to 10% more than the nominal 3.13 nm, we need N < 4. If we limit it to under 4 nm (ESRF's emittance), then we have N < 10. Table 1 lists parameters of the new source point, assuming that we insert three such modules in the ring (N = 3) and that we have a 1.5% ratio of the raw emittances. We attempted to improve the emittance and matching by allowing a gradient in the dipoles, thinking that perhaps it would provide additional optics flexibility. However, no improvement was obtained.

43 PARTICLE ACCELERATORS↗

CFM-ID 4.0: More Accurate ESI MS/MS Spectral Prediction and Compound Identification

In the field of metabolomics, mass spectrometry (MS) is the method most commonly used for identifying and annotating metabolites. As this typically involves matching a given MS spectrum against an experimentally acquired reference spectral library, this approach is limited by the coverage and size of such libraries (which typically number in the thousands). These experimental libraries can be greatly extended by predicting the MS spectra of known chemical structures (which number in the millions) to create computational reference spectral libraries. To facilitate the generation of predicted spectral reference libraries we developed CFM-ID, a computer program that can accurately predict ESI-MS/MS spectrum for a given compound structure. CFM-ID is one of the best-performing methods for compound-to-mass-spectrum prediction, and also one of the top tools for in silico mass-spectrum-to-compound identification. This work improves CFM-ID’s ability to predict ESI-MS/MS spectra from compounds by: (1) learning parameters from features based on the molecular topology, (2) adding a new approach to ring cleavage that models such cleavage as a sequence of simple chemical bond dissociations and (3) expanding its hand-written rule-based predictor to cover more chemical classes, including acylcarnitines, acylcholines, flavonols, flavones, flavanones, and flavonoid glycosides. We demonstrate that this new version of CFM-ID (version 4.0) is significantly more accurate than previous CFM-ID versions, in terms of both EI-MS/MS spectral prediction and compound identification. CFM-ID 4.0 is available at http://cfmid4.wishartlab.com/ as a webservice and docker images can be downloaded at https://hub.docker.com/r/wishartlab/cfmid

Wang, Fei↗

Structures of Class Id Ribonucleotide Reductase Catalytic Subunits Reveal a Minimal Architecture for Deoxynucleotide Biosynthesis

Class I ribonucleotide reductases (RNRs) share a common mechanism of nucleotide reduction in a catalytic α subunit. All RNRs initiate catalysis with a thiyl radical, generated in class I enzymes by a metallocofactor in a separate β subunit. Class Id RNRs use a simple mechanism of cofactor activation involving oxidation of a Mn II 2 cluster by free superoxide to yield a metal-based Mn III Mn IV oxidant. This simple cofactor assembly pathway suggests that class Id RNRs may be representative of the evolutionary precursors to more complex class Ia–c enzymes. X-ray crystal structures of two class Id α proteins from Flavobacterium johnsoniae (Fj) and Actinobacillus ureae (Au) reveal that this subunit is distinctly small. The enzyme completely lacks common N-terminal ATP-cone allosteric motifs that regulate overall activity, a process that normally occurs by dATP-induced formation of inhibitory quaternary structures to prevent productive β subunit association. Class Id RNR activity is insensitive to dATP in the Fj and Au enzymes evaluated here, as expected. However, the class Id α protein from Fj adopts higher-order structures, detected crystallographically and in solution. The Au enzyme does not exhibit these quaternary forms. Our study reveals structural similarity between bacterial class Id and eukaryotic class Ia α subunits in conservation of an internal auxiliary domain. Overall, our findings with the Fj enzyme illustrate that nucleotide-independent higher-order quaternary structures can form in simple RNRs with truncated or missing allosteric motifs.

59 BASIC BIOLOGICAL SCIENCES↗

Beamline CSX (23-ID, EPU 49): 25 mA Commissioning Radiation Survey Report

A comprehensive radiological survey of the Beamline CSX (23-ID-1) was conducted on March 27, 2015 in accordance with the Beamline CSX (23-ID, EPU 49) Radiation Survey Plan [1]. The purpose of the survey is to verify the shielding integrity of the 23-ID beamline First Optics Enclosure (FOE) and downstream beam pipe. At the time of this comprehensive survey, 23-ID-2 beamline was still undergoing technical commissioning and therefore Section II “23 ID-2 FOE, exclusion zone and downstream pipe” could not be completed. During the surveys the stored beam current varied between 21.43 mA and 23.51 mA, the 23-ID straight section vacuum was around 0.44 ntorr, and front-end slits were open near their hard stop limits.

36 MATERIALS SCIENCE↗

SpaceWire Protocol ID: What Does It Mean To You?

Spacewire is becoming a popular solution for satellite high-speed data buses because it is a simple standard that provides great flexibility for a wide range of system requirements. It is simple in packet format and protocol, allowing users to easily tailor their implementation for their specific application. Some of the attractive aspects of Spacewire that make it easy to implement also make it hard for future reuse. Protocol reuse is difficult because Spacewire does not have a defined mechanism to communicate with the higher layers of the protocol stack. This has forced users of Spacewire to define unique packet formats and define how these packets are to be processed. Each mission writes their own Interface Control Document (ICD) and tailors Spacewire for their specific requirements making reuse difficult. Part of the reason for this habit may be because engineers typically optimize designs for their own requirements in the absence of a standard. This is an inefficient use of project resources and costs more to develop missions. A new packet format for Spacewire has been defined as a solution for this problem. This new packet format is a compliment to the Spacewire standard that will support protocol development upon Spacewire. The new packet definition does not replace the current packet structure, i.e., does not make the standard obsolete, but merely extends the standard for those who want to develop protocols over Spacewire. The Spacewire packet is defined with the first part being the Destination Address, which may be one or more bytes. This is followed by the packet cargo, which is user defined. The cargo is truncated with an End-Of-Packet (EOP) marker. This packet structure offers low packet overhead and allows the user to define how the contents are to be formatted. It also provides for many different addressing schemes, which provide flexibility in the system. This packet flexibility is typically an attractive part of the Spacewire. The new extended packet format adds one new field to the packet that greatly enhances the capability of Spacewire. This new field called the Protocol Identifier (ID) is used to identify the packet contents and the associated processing for the packet. This feature along with the restriction in the packet format that uses the Protocol ID, allows a deterministic method of decoding packets that was not before possible. The first part of the packet is still the Destination Address, which still conforms to the original standard but with one restriction. The restriction is that the first byte seen at the destination by the user needs to be a logical address, independent of the addressing scheme used. The second field is defined as the Protocol ID, which is usually one byte in length. The packet cargo (user defined) follows the Protocol ID. After the packet cargo is the EOP, which defines the end of packet. The value of the Protocol ID is assigned by the Spacewire working group and the protocol description published for others to use. The development of Protocols for Spacewire is currently the area of greatest activity by the Spacewire working group. The first protocol definition by the working group has been completed and is now in the process of formal standardization. There are many other protocols in development for missions that have not yet received formal Protocol ID assignment, but even if the protocols are not formally assigned a value, this effort will provide synergism for future developments.

Rakow, Glenn↗

Evaluating lightweight unsupervised online IDS for masquerade attacks in CAN

Vehicular controller area networks (CANs) are susceptible to masquerade attacks by malicious adversaries. In masquerade attacks, adversaries silence a targeted ID and then send malicious frames with forged content at the expected timing of benign frames. As masquerade attacks could seriously harm vehicle functionality and are the stealthiest attacks to detect in CAN, recent work has devoted attention to compare frameworks for detecting masquerade attacks in CAN. However, most existing works report offline evaluations using CAN logs already collected using simulations that do not comply with the domain’s real-time constraints. Here we contribute to advance the state of the art by presenting a comparative evaluation of four different non-deep learning (DL)-based unsupervised online intrusion detection systems (IDS) for masquerade attacks in CAN. Our approach differs from existing comparative evaluations in that we analyze the effect of controlling streaming data conditions in a sliding window setting. In doing so, we use realistic masquerade attacks being replayed from the ROAD dataset. We show that although evaluated IDS are not effective at detecting every attack type, the method that relies on detecting changes in the hierarchical structure of clusters of time series produces the best results at the expense of higher computational overhead. We discuss limitations, open challenges, and how the evaluated methods can be used for practical unsupervised online CAN IDS for masquerade attacks.

Anomaly detection↗

Toward operation of series IDs at BL43LXU of SPring-8

This paper discusses two issues relating to using 3 small gap insertion devices in series at BL43LXU of SPring-8 to make a uniquely powerful source in the 15-26 keV region of the x-ray spectrum. The issues discussed are (1) damage to the covers of the downstream IDs by radiation from the upstream IDs and (2) proper steering of the electron beam to get the best photon beam properties. After tests in several configurations, including one where an ID was run without an impedance-reducing cover, the damage issue was solved by installing a distributed absorber in the most downstream ID. The steering issues were mostly resolved by the introduction of appropriate corrector magnets and feedback. The paper is written from the viewpoint of an interested beamline scientist impressed with the cooperation of different groups to make a source for new science possible.

43 PARTICLE ACCELERATORS↗

FUSARIUM-ID v.3.0: An Updated, Downloadable Resource for Fusarium Species Identification

Species within Fusarium are of global agricultural, medical, and food/feed safety concern and have been extensively characterized. However, accurate identification of species is challenging and usually requires DNA sequence data. FUSARIUM-ID ( http://isolate.fusariumdb.org/blast.php ) is a publicly available database designed to support the identification of Fusarium species using sequences of multiple phylogenetically informative loci, especially the highly informative ~680-bp 5' portion of the translation elongation factor 1-alpha (TEF1) gene that has been adopted as the primary barcoding locus in the genus. However, FUSARIUM-ID v.1.0 and 2.0 had several limitations, including inconsistent metadata annotation for the archived sequences and poor representation of some species complexes and marker loci. Here, we present FUSARIUM-ID v.3.0, which provides the following improvements: (i) additional and updated annotation of metadata for isolates associated with each sequence, (ii) expanded taxon representation in the TEF1 sequence database, (iii) availability of the sequence database as a downloadable file to enable local BLAST queries, and (iv) a tutorial file for users to perform local BLAST searches using either freely available software, such as SequenceServer, BLAST+ executable in the command line, and Galaxy, or the proprietary Geneious software. FUSARIUM-ID will be updated on a regular basis by archiving sequences of TEF1 and other loci from newly identified species and greater in-depth sampling of currently recognized species.

Plant Sciences↗

Defining the safe current limit for opening ID photon shutter

The NSLS-II storage ring is protected from possible damage from insertion devices (IDs) synchrotron radiation by a dedicated active interlock system (AIS). It monitors electron beam position and angle and triggers beam drop if beam orbit exceeds the boundaries of pre-calculated active interlock envelope (AIE). The beamlines (BL) and beamline frontends (FE) are designed under assumption that the electron beam is interlocked within the AIE. For historic reasons the AIS engages the ID active interlock (AI-ID) at any non-zero beam current whenever the ID photon shutter (IDPS) is getting opened. Such arrangement creates major inconveniences for BLs commissioning. Apparently there is some IDPS safe current limit (SCL) under which the IDPS can be opened without interlocking the e-beam. The goal of this paper is to find such limit.

43 PARTICLE ACCELERATORS↗

Earth observing system. Output data products and input requirements, version 2.0. Volume 2: Analysis of IDS input requirements

On 18 Jan. 1991, NASA confirmed 29 Inter-Disciplinary Science (IDS) teams, each involving a group of investigators, to conduct interdisciplinary research using data products from Earth Observing System (EOS) instruments. These studies are multi-disciplinary and require output data products from multiple EOS instruments, including both FI and PI instruments. The purpose of this volume is to provide information on output products expected from IDS investigators, required input data, and retrieval algorithms. Also included in this volume is the revised analysis of the 'best' and 'alternative' match data products for IDS input requirements. The original analysis presented in the August 1991 release of the SPSO Report was revised to incorporate the restructuring of the EOS platform. As a result of the reduced EOS payload, some of EOS instruments were deselected and their data products would not be available for IDS research. Information on these data products is also presented.

Lu, Yun-Chi↗

Time-Resolved Research at the Advanced Photon Source Beamline 7-ID

The Sector 7 undulator beamline (7-ID) of the Advanced Photon Source (APS) is dedicated to time-resolved x-ray research and is capable of ultrafast measurements on the order of 100 ps. Beamline 7-ID has a laser laboratory featuring a Ti:Sapphire system (average power of 2.5W, pulse duration <50 fs, repetition rate 1-5 kHz) that can be synchronized to the bunch pattern of the storage ring. The laser is deliverable to x-ray enclosures, which contain diffractometers, as well as motorized optical tables for table-top experiments. Beamline 7-ID has a single APS Undulator A and uses a diamond (111) double-crystal monochromator, providing good energy resolution over a range of 6-24 keV. Available optics include Kirkpatrick-Baez (KB) mirrors to microfocus the x-ray beam. A variety of time-resolved diffraction and spectroscopy research is available at 7-ID, with experiments being done in the atomic, molecular, optical, chemistry, and solid state (bulk and surface) fields.

43 PARTICLE ACCELERATORS↗

Id-1 gene and gene products as therapeutic targets for treatment of breast cancer and other types of carcinoma

A method for treatment of breast cancer and other types of cancer. The method comprises targeting and modulating Id-1 gene expression, if any, for the Id-1 gene, or gene products in breast or other epithelial cancers in a patient by delivering products that modulate Id-1 gene expression. When expressed, Id-1 gene is a prognostic indicator that cancer cells are invasive and metastatic.

60 APPLIED LIFE SCIENCES↗

Idaho National Laboratory Supervisory Control and Data Acquisition Intrusion Detection System (SCADA IDS)

Current Intrusion Detection System (IDS) technology is not suited to be widely deployed inside a Supervisory, Control and Data Acquisition (SCADA) environment. Anomaly- and signature-based IDS technologies have developed methods to cover information technology-based networks activity and protocols effectively. However, these IDS technologies do not include the fine protocol granularity required to ensure network security inside an environment with weak protocols lacking authentication and encryption. By implementing a more specific and more intelligent packet inspection mechanism, tailored traffic flow analysis, and unique packet tampering detection, IDS technology developed specifically for SCADA environments can be deployed with confidence in detecting malicious activity.

42 ENGINEERING↗

ID-SERS Based Reference Method for Quantification of Large Biomolecules on a Single Chip

Accuracy and precision of quantitative SERS results have been significantly increased by applying a method based on the so-called isotope-dilution (ID) principle. In this ID-SERS approach, an isotopically labeled analogue of the target molecule (isotopologue) is spiked to the sample at a known concentration. Due to the slight difference in their molar masses, some Raman bands of the heavier isotopologue are red-shifted with respect to the same signals resulting from the unlabelled compound. As a result, spectra evaluation is reduced to the determination of intensity ratios rather than absolute intensities, and the unknown quantity of the analyte can be calculated from the known quantity of the standard. This procedure is of particular interest in the development of highly accurate reference procedures for metrology in chemistry. Because the sample is spiked prior to any further treatment, potential loss of material or matrix effects would equally affect both isotopologues, without influencing the final result. The method has been successfully applied for quantifying small diagnostic marker molecules like creatinine at their relevant serum concentration levels using silver colloids as SERS substrates. Now, the ID-SERS approach has been realized as a 'one-chip' approach using 'Bio-chips' made of intrinsically grown spherical silver nanoparticles with gaps less than 10 nm in between (Fig. 1). In addition, the scope of the method has been extended to larger biomolecules like peptides which will be shown using the example of the human growth-hormone (hGH) peptide T12 at physiologically relevant serum concentration levels (Fig. 2). Further developments towards the quantification of full proteins will also be reported.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Uncertainty evaluation in reference material characterization by double isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS)

Double isotope dilution inductively coupled plasma mass spectrometry (ID-ICP-MS) is one of the most important measurement methods in the establishment of measurement standards for inorganic analysis. However, there is still no good consensus on approaches for uncertainty evaluation in double ID-ICP-MS. Particularly, approaches to treating the instrumental isotopic fractionation (IIF) phenomenon and correlation between uncertainty sources are diverse and often unclear in the literature. Here, an approach for uncertainty evaluation in double ID-ICP-MS measurements is described. Using three certified reference materials (CRMs), it is shown that the IIF effects cancel out and should not be included in the uncertainty budget. Further, a consistent way of considering correlated sources of uncertainty to prevent double counting of uncertainties is described in detail along with an example of measuring the mass fraction of magnesium in an oyster powder CRM.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards a CAN IDS Based on a Neural Network Data Field Predictor

Modern vehicles contain a few controller area networks (CANs), which allow scores of on-board electronic control units (ECUs) to communicate messages critical to vehicle functions and driver safety. CAN provides a lightweight and reliable broadcast protocol but is bereft of security features. As evidenced by many recent research works, CAN exploits are possible both remotely and with direct access, fueling a growing CAN intrusion detection system (IDS) body of research. A challenge for pioneering vehicle-agnostic IDSs is that passenger vehicles' CAN message encodings are proprietary, defined and held secret by original equipment manufacturers (OEMs). Targeting detection of next-generation attacks, in which messages are sent from the expected ECU at the expected time but with malicious content, researchers are now seeking to leverage "CAN data models'', which predict future CAN messages and use prediction error to identify anomalous, hopefully malicious CAN messages. Yet, current works model CAN signals post-translation, i.e., after applying OEM-donated or reverse-engineered translations from raw data. We present initial IDS results testing deep neural networks used to predict CAN data at the bit level, targeting IDS capabilities that avoiding reverse engineering proprietary encodings. Our results suggest the method is promising for data with signals exhibiting dependence on previous or concurrent inputs.

Pawelec, Krzysztof↗

eBPF Community ID Calculation

The code titled “eBPF Community ID Calculation” allows easy correlation of monitoring logs with existing network forensics logs on high-performance computing (HPC) systems. This code implements the Community ID Flow Hashing standard to calculate community ID Flow identifiers. These identifiers will be used to correlate host forensics logs with network forensics logs. The correlation provides valuable insight and the ability to easily pivot between disparate data sources. The computer code removes the libpcap dependency from the code base.

Maerz, StefanA↗