Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ICSBEP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Delayed Critical and Subcritical Experiments with Polyethylene Moderated Unreflected Thin 15 in. Diameter HEU Metal Plates

The thin ~15 in. diameter highly enriched uranium (HEU) metal plates were assembled to delayed criticality at the Oak Ridge Critical Experiments Facility (ORCEF) in 1969 with various thicknesses of polyethylene (varying from 1/16 to 2$\frac{3}{8}$ inches) between uranium metal plates. The average 235 U enrichment was 93.27 wt. %. These unreflected critical configurations contained 4$\frac{2}{3}$ to 20$\frac{5}{6}$ thin 15 in. diameter HEU metal plates (on loan from Los Alamos National Laboratory [LANL] and shipped to Oak Ridge National Laboratory [ORNL] on June 3, 1969). Depending on the thickness of polyethylene, the enriched uranium masses varying from 28,053 to 135,148 grams. Fractional plate sections consisted of the appropriate number of 60° pie sections. In addition to the measurement at delayed criticality, subcritical measurements were also performed by the inverse kinetic rod drop method. Prompt neutron decay constant measurements were also performed by the Rossi alpha and randomly pulsed neutron method using a time-tagged spontaneous fission californium neutron source; these are briefly reported here. At the time of these measurements in 1969, the thin HEU metal plates were in near-pristine condition with extremely little oxidation, allowing better descriptions of the uranium plates than the use of these plates in a heavily oxidized and deteriorated condition in recent reflected benchmark experiments at the LANL facility at the Nevada Test Site with these same thin highly enriched uranium metal plates. This report documents the experimental information for the measurements performed so that later researchers can perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Evaluation Program (ICSBEP) or a Nuclear Energy Agency (NEA) benchmark. Data from the experiments described should be acceptable for use as criticality safety benchmark experiments for the ICSBEP and the NEA nuclear criticality safety benchmark program once the uncertainty analysis on the measured neutron multiplication factors is completed. Additional data—such as the dimensional inspection reports, uranium isotopic information, and other relevant particulars—should be retrieved from the Y-12 Plant or LANL and incorporated in the final ICSBEP benchmark. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainties in $k_{eff}$ could be as low as ± 0.0002 for some configurations. Other experiments with smaller-diameter than 15 in. diameter HEU metal plates have been benchmarked in HEU-METFAST-001. The prompt neutron time decay measurements could be the basis for an International Reactor Physics Benchmark Program. Preparation of the present report is part of an effort at ORNL to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other US Department of Energy critical experiments facilities using more than 500 operational days of critical facility time. This work for this report publication was supported by the Nuclear Criticality, Radiation Transport and Safety NCSP Program at ORNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EUCLID Sensitivity Database

This report documents the EUCLID sensitivity database along with its several use-cases. EUCLID computed sensitivities for the following integral responses: Criticality of ICSBEP critical assemblies, LLNL pulsed-sphere neutron-leakage spectra, reaction rates in selected ICBSEP critical assemblies, delayed neutron factions of selected ICSBEP critical assemblies, reactivity coefficients in two ICSBEP critical assemblies, sub-critical assembly responses and Rossi-alpha of selected critical assemblies. It is described for each response what the reported observable constitutes, the method we used to obtain the sensitivities, and which integral experiments were studied. It is also documented briefly in what format these sensitivities are stored. These sensitivities were used for many aspects of the EUCLID project, like ML-supported large-scale nuclear-data validation, or optimization of integral experiments. But these sensitivities can also be applied for more established processes in the nuclear-data application field such as adjustment or assessing the upper sub-critical limit.

Delayed Neutron Fraction↗

FY21 Progress of the Oak Ridge Health Physics Research Reactor CAAS Benchmark Evaluation [Slides]

The FY21 version of the evaluation, focusing on element 57 dose at 3 meters, was presented at the ICSBEP Technical Review Group meeting in October 2021 and was not accepted for 2022 publication in the handbook. The main issue was identified and replacement of the element 57 neutron dose benchmark metric by neutron fluence (closer to what was measured) is required. A subgroup was formed, confident for the updated neutron fluence evaluation to be accepted in the ICSBEP handbook. The updated evaluation will be presented again at the 2022 ICSBEP TRG for publication in the 2023 handbook.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Jemima Plate Characterization

The HEU Jemima plates have been utilized in numerous International Criticality Safety Benchmark Evaluation Project (ICSBEP) evaluations. ICSBEP evaluations are a vital com ponent of nuclear data validation for applications across the nuclear community. In the past, different combinations of mass, caliper measurements, and drawing dimensions have been used to define the HEU Jemima plates in ICSBEP evaluations. Some of these combinations result in large density ranges (17 g/cm 3 to 19 g/cm 3 ) or unrealistic densities (greater than 19 g/cm 3 ). Additionally, oxidation of the plates has led to questioning the flatness of each plate, which can add additional gaps in experiment configurations. This work proposes a standardized method of defining the commonly used HEU Jemima plates across different experiments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Uranium–Molybdenum Alloy Critical Experiments for the Design of the Health Physics Research Reactor

Clean critical experiments with a uranium-molybdenum alloy (average of 10.1616 wt. % Mo with a density of 17.08 g/cm 3 ) were performed at the Oak Ridge Critical Experiments Facility in 1961 to support the design of the Health Physics Research Reactor (HPRR). The HPRR was similar to the Godiva burst reactor at Los Alamos National Laboratory and was designed to produce 50 microseconds burst of 10 17 fission pulses of radiation for dosimetry measurements, initially in support of the determination of the doses from the nuclear detonations in Japan during World War II. These experiments reported here were used to verify the calculational methods used to design the HPRR. These delayed critical measurements were:1) a solid unreflected and unmoderated 8-in.-dimeter U-Mo cylinder, 2) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void, 3) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void filled with stainless steel, 4) Same as 3) but with 3-in-thick Plexiglas reflector on top with and without cadmium between the reflector and the U-Mo alloy assembly with steel in the center, and 5) an unmoderated and unreflected annulus which was a modification of the second but with the lower 5 inches of the central hole enlarged to 3.5 in. with various reflector conditions. The reflector conditions were: 1-in.-thick Plexiglas on all outer surfaces-void in the center; 1-in.-thick Plexiglas on all outer surfaces-Plexiglas in the center; 2-in.- thick Plexiglas on radial surface-void in the center; 6-in.-thick Plexiglas on the bottom only-Plexiglas in the center; and 6-in.-thick Plexiglas on bottom, 1-in.-thick on top and on the lower 8.25-cm.-section of the radial surface-void in the center. For some of these reflector conditions 0.025-cm.thick cadmium was located between the reflector and the U-Mo alloy. The uranium contained 93.17 wt. % 235 U. Reflection was a safety concern for this unmoderated and unreflected reactor and reduction of reflection effects was also investigated by insertion of neutron absorber around the U-Mo alloy. The stainless steel 304 contained 18% nickel and 8% chromium and the rest iron. The reflector material was a methacrylate plastic (Plexiglas) containing 5.8 x 10 22 atoms/cm 3 of hydrogen and 3.6 x 10 22 atoms/cm 3 of carbon with a density of 1.20 g/cm 3 . The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a EURATON Nuclear Energy Agency (NEA) benchmark. The data from the experiments described should be acceptable for use as criticality safety benchmark experiments for the ICSBEP and the NEA nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainties in k eff could be as low as ±0.0002 for some configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Delayed Critical Highly Enriched Uranium Metal Cylinders with Thin Graphite Top and Bottom Reflectors

Nine 7, 11, and 15 in. diam highly enriched uranium (HEU, 93.15 wt % 235 U) metal cylinders were assembled on the vertical assembly machine in the Oak Ridge Critical Experiments Facility (ORCEF) and had 1, 2, or 3 in. thick HLM graphite reflectors on the top and bottom. The experiments, which were performed between April 3, 1970, and February 18, 1971, used 23 operational days at ORCEF. Before those experiments were carried out, unreflected and unmoderated, graphite- and polyethylene-reflected, and polyethylene-moderated HEU metal cylinders had been assembled to obtain delayed criticality at ORCEF in the 1960s and reported by the International Criticality Safety Benchmark Evaluation Project (ICSBEP) at the Nuclear Energy Agency (NEA)*. The data from the nine critical experiments are acceptable for use as criticality safety benchmark experiments for the NEA’s ICSBEP once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with HEU metal at ORCEF, the uncertainties in k eff are expected to be as low as ±0.0004.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Final Design for Thermal/Epithermal eXperiments (TEX) with Lithium Absorbers to Provide Validation Benchmarks for Y-12 Electrorefining Facility

One of the main goals of the Thermal/Epithermal eXperiments (TEX) project is to use existing Nuclear Criticality Safety Program (NCSP) assets to create critical experiment plutonium and uranium test beds for materials important to criticality safety that have insufficient benchmark evaluations. The plutonium test bed experiments were completed in 2018 and are published in the 2020 edition of the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The uranium test bed assemblies were completed in 2023 and accepted in the 2024 edition of the ICSBEP Handbook. The Nuclear Criticality Safety (NCS) group at Y-12 National Security Complex has identified programmatic need for validation cases for uranium electrorefining operations at Y-12. The electrorefining operation credits lithium enriched in 6 Li in addition to 35 Cl as absorbers in the design criticality safety evaluation for precluding criticality under upset conditions in the large and geometrically unfavorable electro-refiner. There is, however, inadequate experimental validation for the 6 Li absorbers. As an extension of the TEX uranium test bed, TEX-Cl critical experiments were performed with sodium chloride salt to address the 35 Cl thermal absorption as well as other validation needs at Los Alamos National Laboratory (LANL). These experiments were completed in 2024 and accepted into the 2025 ICSBEP Handbook. To continue the methodology used in TEX-Cl, TEX-Li aims to accomplish the same. The overall design of both experiments was to use commercially available, high purity, salts with polyethylene moderator and HEU plates to configure a critical assembly. Three experiments are planned for TEX-Li using encapsulated lithium carbonate (Li 2 CO 3 ), with natural 6 Li abundance. For all experiments, the highly enriched uranium (HEU) Jemima plates will be used as fissile material. Multiple layers will be stacked together with encapsulated Li 2 CO 3 alternated with polyethylene in standard configurations. Standard stacking was found to be optimal in matching the different sensitivity profiles provided by the Y-12 models. Three configurations are proposed with varying polyethylene moderation and a constant 1/4” absorber thickness. The first uses 11 layers of 5/4” polyethylene, the second uses 9 layers of 3/4” polyethylene, and the third uses 10 layers of 1/2” polyethylene. Calculations showed that some alternative forms of lithium-based materials provided slightly less-optimal sensitivity profiles when compared to lithium carbonate but come with other drawbacks. These alternatives included lithium aluminate (LiAlO 2 ), Aluminum-2050 alloy, Aluminum-8090, Aluminum-2095, lithium hydride (LiH), and lithium fluoride (LiF). Lithium aluminate and aluminum-2050 provided comparable sensitivity profiles when compared to lithium carbonate and can be used instead if lithium carbonate cannot be readily procured. After a broad material study, lithium carbonate outperformed any alternative material with a balance in affordability and workability. The assessment of experimental uncertainties of the non-absorber and absorber components was predicted to be 0.00089 and 0.00093 Δk eff , respectively. The largest uncertainties may be reduced with precision dimensional inspection of the components. Many of the parts and equipment for IER 575 have already been fabricated or procured for previous projects and therefore do not contribute significantly to the overall cost of this experiment. This includes the Jemima plates and Comet critical assembly machine, which are existing NCSP assets, as well as the aluminum platen and polyethylene reflector rings, which were fabricated and authorized for the TEX experiment involving HEU with polyethylene. Lithium carbonate containers will be procured by LANL and will be filled by LLNL. The total material costs for TEX-Li experiments are estimated to be on the order of $\$$47,400. Precision inspection, including dimensional, mass, density, and impurity, is recommended for all components for an estimated cost of $\$$12,000.

35Cl↗

Evaluation of Oak Ridge National Laboratory Health Physics Research Reactor Operation Data for Critical Benchmark Creation

The Oak Ridge National Laboratory (ORNL) Health Physics Research Reactor (HPRR) was a research reactor designed and built at ORNL in 1961. The critical assembly used a highly enriched uranium and molybdenum alloy as the fuel and could be operated in steady-state or burst modes. The HPRR has recently been the object of an investigation to create a criticality benchmark. Such benchmarks are very important, as they are used primarily to show the accuracy of newly developed modeling codes and to help experimental validation and reactor licensing. The evaluated experiments considered in this paper were carried out between 1974 and 1986 from various HPRR activities such as steady-state subcritical, steady-state critical, and burst prompt super-critical operations of the reactor for dosimetry, irradiation, or training purposes. By using the HPRR experimental logbook information and the as-built drawings of the critical assembly, a highly detailed model of the HPRR was created with SCALE 6.2.4/KENO-VI, and a first version of a critical benchmark of the HPRR was developed following the International Criticality Safety Benchmark Evaluation Project (ICSBEP) guidelines for thorough description and uncertainty/sensitivity quantification. Unfortunately, in most of the evaluated experiments, the obtained difference between calculated and experimental k eff is around 1,000 pcm, corresponding to a relative error of approximately 1%, beyond the quality standards of the ICSBEP recommending a relative error below 0.1%. Moreover, the derived experimental uncertainty is high, around 4% relative, mainly due to the U-Mo fuel density uncertainty, but also from numerous other factors. For these reasons, the creation of a valuable critical benchmark from HPRR operation data is thus far compromised. In this paper, the different steps of the experiments’ evaluation are summarized, and the reasons for the experimental/calculation discrepancies and potential ways to solve them are explored. This paper also aims to remind us always to exercise considerable care when performing experimental work, and to record all the data possible for potential future uses.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design of Critical Experiments Targeting Epithermal Cross Sections of Tantalum

Sandia National Laboratories (SNL) and Oak Ridge National Laboratory (ORNL) are collaborating to develop a capability to test the epithermal/intermediate cross sections of tantalum (Ta) at the SNL critical experiments facility using the Seven Percent Critical Experiment (7uPCX) fuel. The Sandia Critical Experiments (SCX) Program provides a specialized facility for performing water moderated and reflected critical experiments with UO 2 fuel rod arrays. A history of safe reactor operations and flexibility in reactor core configuration has resulted in the completion of several benchmark critical experiment evaluations that are published in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The critical experiments described here are scheduled to be performed at SCX in fiscal year 2023. Currently, fabrication details for the needed new equipment are being finalized for completion of the procurement process. The experiments will then be executed and documented for publication consideration by the ICSBEP.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Delayed Critical Enriched Uranium Metal, 7-in.-diam. Cylinder with Thin Stainless Steel Top and Bottom Reflectors

Three 7 in. diameter highly enriched uranium (HEU; 93.17 wt % 235 U) metal cylinders were assembled on the vertical assembly machine of the Oak Ridge Critical Experiments Facility (ORCEF) with thin stainless steel reflectors (0.5, 1, and 2 in. thick) on the top and bottom. These experiments were performed during January 13–25, 1965, and used seven operational days at ORCEF. Before these experiments, unreflected and unmoderated 7 in. diameter HEU metal cylinders had been assembled to delayed criticality at ORCEF, and the results were benchmarked in HEU-MET-FAST-051. In addition to the critical experiments, the prompt neutron decay constant was measured via the Rossi-α technique, and those results are also presented in this report. To achieve near-delayed-critical systems, 5 × 5 × 0.03125 in. rectangular uranium metal parts were used on top of 7 in. diameter cylinders inside the top reflector. The delayed critical configuration from the three experiments described herein are acceptable for use as criticality safety benchmark experiments for the International Criticality Safety Benchmark Evaluation Program (ICSBEP), coordinated by the Nuclear Energy Agency, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainty in $k_{eff}$ is expected to be as low as ±0.0002. The prompt neutron time decay data could be the basis of an International Reactor Physics Evaluation Program benchmark.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Joint LLNL, LANL, SNL, and IRSN High Multiplication Subcritical (Multiplicity) Benchmark Integral Experiment Execution (CED-3b Report)

This report documents the experimental configurations and measurements for IER-518: Joint LLNL, LANL, SNL, and IRSN High Multiplication Subcritical (Multiplicity) Benchmark Experiments. These measurements involved a series of subcritical configurations at the Sandia Critical Experiments (SCX) facility at Sandia National Laboratories (SNL). The purpose of these measurements was to produce time tagged neutron count data of configurations that exceed a subcritical multiplication of 20, which is the high end of the fundamental physics benchmarks currently available in the International Criticality Safety Benchmark Evaluation Project Handbook (ICSBEP). These measurements leverage experimental configurations 1 and detector systems 2 from previously accepted ICSBEP benchmark evaluations, allowing evaluations of these measurements to be performed at greatly reduced cost.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of MCNP Critical Benchmarks Models of Highly Enriched Uranium Cylinders

A new centralized repository of high-quality MCNP models of critical benchmark experiments is currently under development at Los Alamos National Laboratory (LANL). The benchmark experiments are described in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook, and the initial set of benchmark models are derived from the Whisper Suite provided with MCNP6.2. This effort is a collaboration among the Nuclear Criticality Safety, Nuclear Data, and Monte Carlo code development/application organization at LANL. The objective is to create a current single LANL benchmark collection that includes the latest ICSBEP revision that has a formal review and revision process, is contained in an open- source repository, and utilizes new Python tools for improved input and output file review.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Preliminary Chlorine Worth Study Benchmark Evaluation

The Chlorine Worth Studies (CWS) experiments with polyvinyl chloride (PVC with chemical formula (C 2 H 3 Cl) n ), chlorinated polyvinyl chloride (CPVC with chemical formula (C 9 H 11 Cl 7 ) n ), and high density polyethylene (HDPE with chemical formula (CH 2 ) n ) were a series of measurements performed at the National Criticality Experiments Research Center (NCERC). The purpose of the CWS experiments was to perform integral experiments that were highly sensitive to the thermal 35 Cl(n,γ) reaction and matched the sensitivities of aqueous chloride operations at the plutonium facility at Los Alamos National Laboratory (LANL). The CWS experiments were performed on the Planet critical assembly machine at NCERC and utilized weapons grade plutonium (WGPu) plates as fuel. The design process and design of the CWS experiment were discussed previously. This paper discusses the benchmark evaluation of the experiment, intended for the International Criticality Safety Benchmark Evaluation Project (ICSBEP). Criticality calculations were performed with MCNP version 6.3. Results presented here are preliminary, as the benchmark has not yet been submitted to the ICSBEP.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Impact of recent ENDF nuclear data update, high initial enrichment and high burnup fuel on critical experiments applicability determination via the integral index c k for burnup credit validation

In 2012, NUREG/CR-7109 reported on the validation of burnup credit calculations involving major and minor actinides and major fission products which was investigated for pressurized and boiling water reactor (PWR and BWR) fuel enrichments up to 5 wt% 235 U and assembly-average burnups up to 60 GWd/MTU. Recently, there has been interest in increasing the maximum enrichment used in PWR fuel as high as 8 wt% 235 U and correspondingly increasing the maximum assembly-average burnups to approximately 75 GWd/MTU. These proposed increases in enrichment and burnup necessitate reinvestigation of the validation basis for k eff calculations for this expanded application space. Additionally, the 2012 study was performed by using the Evaluated Nuclear Data File (ENDF)/B-VII.0 nuclear data with the SCALE 6 covariance library, and the effects of using the newly released ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear data and covariance libraries should be evaluated. In this work, published in NUREG/CR-7309 in 2025, the validation assessment was performed consistently with NUREG/CR-7109: modeling irradiated fuel assemblies in the Generic Burnup Credit (GBC)-32 cask defined in NUREG/CR-6747. The TSUNAMI-3D sequence was used to generate sensitivity data for the application model, and the data were compared with sensitivity data from select benchmark models. The integral parameter c k is the metric of similarity used in this study and is consistent with NUREG/CR-7109, where a c k value in excess of 0.8 indicates sufficient similarity for use in validation. A new set of benchmark experiments with sensitivity data has been assembled for this effort. The number of experiments with available sensitivity data is now 2,104, compared to 474 in NUREG/CR-7109. This increase was facilitated by the efforts of the Nuclear Energy Agency to generate sensitivity data for a majority of the experiments in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook to supplement the data available in the Oak Ridge National Laboratory (ORNL) Verified, Archived Library of Inputs and Data (VALID). The complete set of benchmarks considered here includes experiments for low-enriched uranium (LEU), intermediate enriched uranium (IEU), and a mixture of uranium and plutonium (MIX) from the ICSBEP Handbook and VALID, as well as ORNL models of the Haut Taux de Combustion (HTC) experiments and other potentially relevant models not included in VALID. The updated similarity study shows that none of the extended burnup and higher enrichment combinations considered show a significant decrease in the number of potentially applicable experiments, meaning sufficient critical experiments exist for the validation of BUC criticality safety calculations, with initial enrichments up to 8 wt% 235 U and burnups up to 80 GWd/MTU. Additionally, both the ENDF/B-VII.1 and ENDF/B-VIII.0 nuclear data libraries can be used for validation since the number of critical experiments applicable for validation increases for most cases with the most recent nuclear data compared to the previous one. As in previous BUC validation studies, the French HTC experiments are the most similar in a majority of the application cases studied, especially from representative discharge burnups ranging from 40 to 80 GWd/MTU. In conclusion, these results match the conclusions presented in NUREG/CR-7109 regarding validation of the primary actinides in BUC analyses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation of Jezebel Reactivity Coefficients and Sensitivity Analysis

Nuclear data validation is often performed today using criticality measurements. The gold standard for criticality measurements is the International Criticality Safety Benchmark Experiment Project (ICSBEP). The validation specifically focuses on the effective multiplication factor ($k_{eff}$). $K_{eff}$ is a relatively easy parameter to infer and has reduced uncertainty due to being at or above critical. However, while $k_{eff}$ is the most documented parameter and its uncertainties and sensitivities have been evaluated in great detail, it cannot be used as a standalone metric to determine inaccuracies in nuclear data (e.g., cross section data, PFNS, nu), which is based on theory, physics, and differential measurements. The Experiments Underpinned by Computational Learning for Improvements in nuclear Data (EUCLID) project aims to identify compensating errors in specific isotope nuclear data by optimally designing experiments that are, or are not sensitive to a suite of measurement parameters beyond $k_{eff}$. By identifying parameters that are sensitive to each other, oppositely sensitive, or have substantial magnitude differences in sensitivity, experiments can be designed to constrain questionable nuclear data. One sensitivity that is of particular interest to this project includes the sensitivity of reactivity coefficients. Reactivity coefficients compare reactivity, which is related to $k_{eff}$ at two different states therefore being sensitive to small changes in the system. The most common type of reactivity coefficient measurements is comparison to void for a small sample within the assembly. It is key that the sample sizes are small enough to not affect the flux of the full system. Reactivity coefficients were evaluated for many early experiments to better understand transport corrected cross sections. In fact, ICSBEP includes reactivity coefficient results as “Supplemental Measurements” in appendices for a handful of older benchmarks. One of those benchmarks is Jezebel, the bare Pu critical assembly. This paper compares new simulations of reactivity coefficients for Jezebel, and explores the sensitivity of reactivity coefficients to small changes in nuclear data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Release of Evaluated 235 U(n,f) Average Prompt Fission Neutron Multiplicities Including the CGMF Model

This report documents an evaluation of the average prompt fission neutron multiplicity, $\overline{v}_p$, of 235 U from 200 keV to 15 MeV that is a potential release candidate for the upcoming U.S. nuclear data library, ENDF/B-VIII.1. This evaluation had to be re-done from "scratch", as the input to the $\overline{v}_p$ evaluation of the previous library, ENDF/B-VIII.0, was lost. That means that all available experimental data were re-analyzed and uncertainties were re-estimated. Another major difference to ENDF/B-VIII.0 is that this evaluation includes model information from the Hauser-Feshbach fission fragment decay code CGMF, while ENDF/B-VIII.0 is based purely on experimental data. CGMF links several fission quantities with each other; $\overline{v}_p$ is predicted by assumptions made on, e.g., pre-neutron emission yields as a function of mass, the total kinetic energy, or spin and parity of fission fragments. This allows to perform two types of validation for the new 235 U $\overline{v}_p$: On the one hand, one can employ evaluated CGMF parameters obtained from fitting to experimental 235 U $\overline{v}_p$ to predict yields as a function of mass, the average total kinetic energy, or the mean energy of the prompt fission neutron spectrum. These model-predicted values can then be compared to experimental and evaluated data. The model-predicted fission-observable values using evaluated parameters obtained here are reasonably close to experimental data indicating the evaluated 235 U(n,f) $\overline{v}_p$ are physical. On the other hand, one can validate 235 U $\overline{v}_p$ with respect to integral responses such as fast ICSBEP critical assemblies or LLNL pulsed spheres. LLNL pulsed-sphere neutron-leakage spectra are minimally impacted by the new 235 U $\overline{v}_p$ as these experimental data are shape data and the $\overline{v}_p$ would mostly lead to a change in normalization of the data as the spheres are relatively thin (0.7 and 1.5 mean-free path) and, thus, mostly depend on 235 U $\overline{v}_p$ from 12-15 MeV. The change in the predicted effective neutron multiplication factor, k eff , of selected ICSBEP critical assemblies, however, is large compared to values using ENDF/B-VIII.0 and experimental k eff : The average bias is 108 pcm across all studied k eff values versus 12 pcm for ENDF/B-VIII.0. A reasonable performance in simulating keff (mean bias of 14 pcm) can be retained by tweaking 235 U $\overline{v}_p$ from 3-5 MeV, and combining it with a recent 235 U PFNS evaluation that is also a ENDF/B-VIII.1 release candidate.

235U↗

CERBERUS: CED-2 Final Design Report

The goal of the Critical Experiment Reflected By copper to bEtteR Understand Scattering [CERBERUS] is to design a critical experiment that maximizes sensitivities to copper (Cu) reactions, particularly in the intermediate energy region (0.625 eV – 100 keV) as well as the 100 – 600 keV energy region. Despite the number of experiments evaluated in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook1 , there is still a lack of benchmarks sensitive to neutrons in the intermediate energy region. The ZEUS series was designed specifically to provide data in the intermediate energy range. The ZEUS series used Cu reflectors to allow for the construction of an intermediate energy system that could be constructed within a reasonable size. While the reflection provided by Cu reduces the size of the system, it creates a system that is very sensitive to the angular scattering in Cu. A neutron scattering off Cu at some angles reflects back into to the system, while at other angles, it is lost entirely. Of the ICSBEP benchmarks sensitive to neutrons in the intermediate energy region, very few are also sensitive to Cu in that region. Improving Cu nuclear data is important outside of the ZEUS series, because it is present in many bronze and aluminum alloys, which are used in various nuclear operations such as motors, wires, and some containers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

IER 555: Godiva Benchmark Update CED-2 (Final Design Report)

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) evaluation of the Godiva IV critical assembly, HEU-MET-FAST-086: GODIVA-IV DELAYED-CRITICAL EXPERIMENTS (HMF-086), was completed by Russ Mosteller. Five critical experiment configurations performed at the Los Alamos National Laboratory (LANL) Technical Area (TA)-18 were evaluated as acceptable benchmark cases. The five cases consist of four delayed critical configurations which differ in control rod positions and one prompt critical configuration. All cases calculated a lower $k_{eff}$ than measured by experiment. This data is referred to as the TA-18 Godiva IV benchmark in this report. In 2005, Godiva IV was disassembled for relocation to the Nevada Test Site (NTS), now Nevada National Security Site (NNSS), at the National Criticality Experiments Research Center (NCERC). Following the disassembly and subsequent reassembly and startup of Godiva IV at NCERC, additional information about the Godiva IV components was obtained. An errata note was added to the HMF-086 evaluation in the ICSBEP handbook to provide this new information until a revision to the benchmark evaluation could be performed. In addition to those corrections, there are differences between the Godiva IV assembly at TA-18 and the Godiva IV assembly at NCERC. These differences include both assembly-specific differences (differences in the safety block gap, differences in the control rod positions, a new NCERC Top Hat and contamination shield) as well as environmental differences, such as the size and shape of the experimental building where the assembly is located. An additional model with similar cases, referred to as the NCERC Godiva IV benchmark in this report, will be added to the revised HMF-086 to capture these additional differences. This will provide the best benchmark model of Godiva for use by those performing experiments at NCERC. The IER 555 CED-2 report documents the information that will be updated in the HMF-086 revision, both the corrections to the TA-18 Godiva IV benchmark and the subsequent changes to create a NCERC Godiva IV benchmark. It describes the measurements that will be performed for cases similar to those performed at TA-18. It also describes measurements that will be included in the evaluation as additional data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗