Humidity-Dependent Electrostatic Charge Decay on Dielectric Surface in Enclosed Volumes
Electrostatic surface charge decay is investigated to determine loss mechanisms, the effect of humidity, enclosure size, and material. This work focuses on charging dielectric and metal surfaces close to the electrical breakdown threshold in atmospheric air under humid and dry conditions. After initial charging to a maximum potential of roughly 30 kV, the associated surface charge is allowed to decay because of recombining with ions from the natural background, resulting in decay times ranging from minutes to hours to days. Spheres with a radius of 50 mm consisting of varying materials (PTFE and metal as referenced later) are charged and tested at relative humidity levels, RH, of 10%, 35%, and 64%. It was found that the ion-ion pair production rate and the enclosure size affected the measured charge decay rate. The impact of air convection on charge decay in the open air (no enclosure) is discussed. The humidity increased the rate of charge decay on the metal and dielectric spheres. For example, in the first 25 minutes after charging, the total charge on the PTFE sphere decreased to 66%or 50% from its initial value in the 10% and 35% RH tests, respectively. An equivalent generation rate is found for the ions in the enclosure, with 10 and 24 ion pairs cm −3 s −1 being generated at a 5% and 49% relative humidity, respectively.