Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Human body”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

On the dynamics of a human body model.

Equations of motion for a model of the human body are developed. Basically, the model consists of an elliptical cylinder representing the torso, together with a system of frustrums of elliptical cones representing the limbs. They are connected to the main body and each other by hinges and ball and socket joints. Vector, tensor, and matrix methods provide a systematic organization of the geometry. The equations of motion are developed from the principles of classical mechanics. The solution of these equations then provide the displacement and rotation of the main body when the external forces and relative limb motions are specified. Three simple example motions are studied to illustrate the method. The first is an analysis and comparison of simple lifting on the earth and the moon. The second is an elementary approach to underwater swimming, including both viscous and inertia effects. The third is an analysis of kicking motion and its effect upon a vertically suspended man such as a parachutist.

Huston, R. L.↗

Modifications to an interactive model of the human body during exercise: With special emphasis on thermoregulation

Since 1988 an interactive computer model of the human body during exercise has been under development by a number of undergraduate students in the Department of Chemical Engineering at Iowa State University. The program, written under the direction of Dr. Richard C. Seagrave, uses physical characteristics of the user, environmental conditions and activity information to predict the onset of hypothermia, hyperthermia, dehydration, or exhaustion for various levels and durations of a specified exercise. The program however, was severely limited in predicting the onset of dehydration due to the lack of sophistication with which the program predicts sweat rate and its relationship to sensible water loss, degree of acclimatization, and level of physical training. Additionally, it was not known whether sweat rate also depended on age and gender. For these reasons, the goal of this creative component was to modify the program in the above mentioned areas by applying known information and empirical relationships from literature. Furthermore, a secondary goal was to improve the consistency with which the program was written by modifying user input statements and improving the efficiency and logic of the program calculations.

Scherb, Megan Kay↗

Distribution and pharmacokinetics of methamphetamine in the human body: clinical implications

Methamphetamine is one of the most toxic of the drugs of abuse, which may reflect its distribution and accumulation in the body. However no studies have measured methamphetamine's organ distribution in the human body. Positron Emission Tomography (PET) was used in conjunction with [{sup 11}C]d-methamphetamine to measure its whole-body distribution and bioavailability as assessed by peak uptake (% Dose/cc), rate of clearance (time to reach 50% peak-clearance) and accumulation (area under the curve) in healthy participants (9 Caucasians and 10 African Americans). Methamphetamine distributed through most organs. Highest uptake (whole organ) occurred in lungs (22% Dose; weight {approx}1246 g), liver (23%; weight {approx}1677 g) and intermediate in brain (10%; weight {approx}1600 g). Kidneys also showed high uptake (per/cc basis) (7%; weight 305 g). Methamphetamine's clearance was fastest in heart and lungs (7-16 minutes), slowest in brain, liver and stomach (>75 minutes), and intermediate in kidneys, spleen and pancreas (22-50 minutes). Lung accumulation of [{sup 11}C]d-methamphetamine was 30% higher for African Americans than Caucasians (p < 0.05) but did not differ in other organs. The high accumulation of methamphetamine, a potent stimulant drug, in most body organs is likely to contribute to the medical complications associated with methamphetamine abuse. In particular, we speculate that methamphetamine's high pulmonary uptake could render this organ vulnerable to infections (tuberculosis) and pathology (pulmonary hypertension). Our preliminary findings of a higher lung accumulation of methamphetamine in African Americans than Caucasians merits further investigation and questions whether it could contribute to the infrequent use of methamphetamine among African Americans.

59 BASIC BIOLOGICAL SCIENCES↗

Online determination of biophysical parameters of mucous membranes of a human body

We have developed a method for online determination of biophysical parameters of mucous membranes (MMs) of a human body (transport scattering coefficient, scattering anisotropy factor, haemoglobin concentration, degrees of blood oxygenation, average diameter of capillaries with blood) from measurements of spectral and spatial characteristics of diffuse reflection. The method is based on regression relationships between linearly independent components of the measured light signals and the unknown parameters of MMs, obtained by simulation of the radiation transfer in the MM under conditions of its general variability. We have proposed and justified the calibration-free fibre-optic method for determining the concentration of haemoglobin in MMs by measuring the light signals diffusely reflected by the tissue in four spectral regions at two different distances from the illumination spot. We have selected the optimal wavelengths of optical probing for the implementation of the method. (laser applications in biology and medicine)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

More-Realistic Digital Modeling of a Human Body

A MATLAB computer program has been written to enable improved (relative to an older program) modeling of a human body for purposes of designing space suits and other hardware with which an astronaut must interact. The older program implements a kinematic model based on traditional anthropometric measurements that do provide important volume and surface information. The present program generates a three-dimensional (3D) whole-body model from 3D body-scan data. The program utilizes thin-plate spline theory to reposition the model without need for additional scans.

Rogge, Renee↗

NEAR-FIELD CHARACTERIZATION OF RECONFIGURABLE NARROWBAND ANTENNA IN THE PROXIMITY OF THE HUMAN BODY

Reconfigurable antennas have been suggested recently for use in various mobile systems. These systems are usually operated in the vicinity of human body, leading to mutual interaction with body tissues. A nondestructive evaluation method is developed to characterize a reconfigurable antenna designed to cover the GSM-900/DCS-1800 bands. Modeling based on FDTD is performed of the antenna in free space and in proximity to the human head. Results reveal frequency shift, and variations in the matching and bandwidth, depending on antenna orientation with respect to the head. Experimental setup is also used to characterize the SAR values in human head. A six-degree-of-freedom robot is implemented to scan a head phantom using specialized sensors and head simulating liquids. The developed system provides a tool for guiding the design of the new category of reconfigurable antennas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Temperature distribution in the human body under various conditions of induced hyperthermia

A mathematical model based on heat balance equations was developed for studying temperature distribution in the human body under deep hyperthermia which is often induced in the treatment of malignant tumors. The model yields results which are in satisfactory agreement with experimental data. The distribution of temperature under various conditions of induced hyperthermia, i.e. as a function of water temperature and supply rate, is examined on the basis of temperature distribution curves in various body zones.

Korobko, O. V.↗

RF Device for Acquiring Images of the Human Body

A safe, non-invasive method for forming images through clothing of large groups of people, in order to search for concealed weapons either made of metal or not, has been developed. A millimeter wavelength scanner designed in a unique, ring-shaped configuration can obtain a full 360 image of the body with a resolution of less than a millimeter in only a few seconds. Millimeter waves readily penetrate normal clothing, but are highly reflected by the human body and concealed objects. Millimeter wave signals are nonionizing and are harmless to human tissues when used at low power levels. The imager (see figure) consists of a thin base that supports a small-diameter vertical post about 7 ft (=2.13 m) tall. Attached to the post is a square-shaped ring 2 in. (=5 cm) wide and 3 ft (=91 cm) on a side. The ring is oriented horizontally, and is supported halfway along one side by a connection to a linear bearing on the vertical post. A planar RF circuit board is mounted to the inside of each side of the ring. Each circuit board contains an array of 30 receivers, one transmitter, and digitization electronics. Each array element has a printed-circuit patch antenna coupled to a pair of mixers by a 90 coupler. The mixers receive a reference local oscillator signal to a subharmonic of the transmitter frequency. A single local oscillator line feeds all 30 receivers on the board. The resulting MHz IF signals are amplified and carried to the edge of the board where they are demodulated and digitized. The transmitted signal is derived from the local oscillator at a frequency offset determined by a crystal oscillator. One antenna centrally located on each side of the square ring provides the source illumination power. The total transmitted power is less than 100 mW, resulting in an exposure level that is completely safe to humans. The output signals from all four circuit boards are fed via serial connection to a data processing computer. The computer processes the approximately 1-MB data set into a three-dimensional image in a matter of seconds. The innovation is to configure the receiver array in a ring topology surrounding the scanned object. The ring is then scanned vertically to cover the necessary two-dimensional surface. This fabrication of the ring is made possible by using planar antenna and circuit technology. A planar circuit board serves as a medium for both antennas and signal processing components. Using this technique, parts counts are kept low, and the cost per element is a small fraction of a waveguide-based system.

Gaier, Todd C.↗

New Window into the Human Body

Michael Vannier, MD, a former NASA engineer, recognized the similarity between NASA's computerized image processing technology and nuclear magnetic resonance. With technical assistance from Kennedy Space Center, he developed a computer program for Mallinckrodt Institute of Radiology enabling Nuclear Magnetic Resonance (NMR) to scan body tissue for earlier diagnoses. Dr. Vannier feels that "satellite imaging" has opened a new window into the human body.

Source record↗