Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hopkinson bar”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Application of the Split Hopkinson Resonant Bar Test for Seismic Property Characterization of Hydrate-bearing Sand Undergoing Water Saturation

Conventional resonant bar tests allow the measurement of seismic properties of rocks and sediments at low frequencies (several kilohertz). However, the tests require a long, slender sample which is often difficult to obtain from the deep subsurface and weak and fractured formations. We present an alternative low-frequency measurement technique to the conventional resonant bar tests. This technique involves a jacketed core sample placed between a pair of long, metal extension rods with attached seismic source and receiver—the same geometry as the split Hopkinson pressure bar test for large-strain, dynamic impact experiments. Because of the added length and mass to the sample, the resonance frequency of the entire system can be lowered significantly, compared to the sample alone. The proposed “Split Hopkinson Resonant Bar (SHRB)” test is applied in two steps. In the first step, extension and torsion-mode resonance frequencies and attenuation of the system are measured. Then, numerical inversions for the compressional and shear wave velocities and attenuation are performed. We initially applied the SHRB test to synthetic materials (plastics) for testing its accuracy, then used it for measuring the seismic velocities and attenuation of a rock core containing supercritical CO 2 , and a sediment core while methane hydrate formed in the pore space.

54 ENVIRONMENTAL SCIENCES↗

A modified Hopkinson pressure bar experiment to evaluate a damped piezoresistive MEMS accelerometer.

We conducted a series of modified Hopkinson pressure bar (HPB) experiments to evaluate a new, damped, high-shock accelerometer that has recently been developed by PCB Piezotronics Inc. Pulse shapers were used to create a long duration, non-dispersive stress pulse in an aluminum bar that interacted with a tungsten disk at the end of the incident bar. We measured stress at the aluminum bar-disk interface with a quartz gage and measured acceleration at the free-end of the disk with an Endevco brand 7270A and the new PCB 3991 accelerometers. The rise-time of the incident stress pulse in the aluminum bar was long enough and the disk length short enough so that the response of the disk can be approximated closely as rigid-body motion; an experimentally verified analytical model has been shown previously to support this assumption. Since the cross-sectional area and mass of the disk were known, we calculated acceleration of the rigid-disk from the quartz-gage force measurement and Newton's Second Law of Motion. Comparisons of accelerations calculated from the quartz-gage data and measured acceleration data show excellent agreement for acceleration pulses with the PCB accelerometer for peak amplitudes between 4,000 and 40,000 Gs , rise times as short as 40 microsec, and pulse durations between 150 and 320 microsec.

47 OTHER INSTRUMENTATION↗

Coupled elasticity, plastic slip, and twinning in single crystal titanium loaded by split-Hopkinson pressure bar

Here coupled elasticity, plastic slip, and twinning in high-purity single crystal titanium loaded by split-Hopkinson pressure bar (SHPB) are investigated, in the framework of large deformation and by utilizing the finite element method (FEM). A thermodynamically consistent system of equations for combined plastic slip and twinning is formulated. Novel kinematics is proposed to develop the driving forces for slip and twinning processes and to consider plastic slip in twins. Dislocation based crystal plasticity is proposed, with an emphasis on the interactions among all slip modes in multi-variant/multiphase heterogeneous materials. A mechanism for dislocation density evolution during twinning is proposed. The impact loading along the [0001] and [1$0\bar{1}$1] directions of single crystal high purity titanium is investigated. The evolution of stress-strain field, dislocation density, and volume fraction for each variant in the sample during the entire loading process are obtained and discussed in detail. Results in simulations show that for the [0001] specimen due to the existence of six symmetry primary twin variants with respect to the loading direction and fifteen different slip systems in each variant, the fields of stress and dislocation density are very homogenous in the sample. The simulation results are compared with experimental data for the [0001] and [1$0\bar{1}$1] specimens. The experimental results are explained and interpreted for both specimens, which include the pole figures, the stress-strain curves, and volume fraction of variants. The simulation results provide an important insight into mechanical responses of high-purity single crystal titanium under high rate loading, and this paper advances the mesoscale modeling and simulations in coupled plastic slip and twinning.

36 MATERIALS SCIENCE↗

Dynamic High-temperature Testing of an Iridium Alloy in Compression at High-strain Rates: Dynamic High-temperature Testing

Iridium alloys have superior strength and ductility at elevated temperatures, making them useful as structural materials for certain high-temperature applications. However, experimental data on their high-strain -rate performance are needed for understanding high-speed impacts in severe environments. Kolsky bars (also called split Hopkinson bars) have been extensively employed for high-strain -rate characterization of materials at room temperature, but it has been challenging to adapt them for the measurement of dynamic properties at high temperatures. In our study, we analyzed the difficulties encountered in high-temperature Kolsky bar testing of thin iridium alloy specimens in compression. We made appropriate modifications using the current high-temperature Kolsky bar technique in order to obtain reliable compressive stress–strain response of an iridium alloy at high-strain rates (300–10 000 s -1 ) and temperatures (750 and 1030°C). The compressive stress–strain response of the iridium alloy showed significant sensitivity to both strain rate and temperature.

36 MATERIALS SCIENCE↗

Mechanical characterization of 304L-VAR stainless steel in tension with a full coverage of low, intermediate, and high strain rates

A 304L-VAR stainless steel is mechanically characterized in tension over a full range of strain rates from low, intermediate, to high using a variety of apparatuses. While low- and high-strain-rate tests are conducted with a conventional Instron and a Kolsky tension bar, the tensile tests at intermediate strain rates are conducted with a fast MTS and a Drop-Hopkinson bar. The fast MTS used in this study is able to obtain reliable tensile response at the strain rates up to 150 s -1 , whereas the lower limit for the Drop-Hopkinson bar is 100 s -1 . Combining the fast MTS and the Drop-Hopkinson bar closes the gap within the intermediate strain rate regime. Using these four apparatuses, the tensile stress-strain curves of the 304L-VAR stainless steel are obtained at strain rates on each order of magnitude ranging from 0.0001 to 2580 s -1 . All tensile stress-strain curves exhibit linear elasticity followed by significant work hardening prior to necking. After necking occurrs, the specimen load decreases, and the deformation becomes highly localized until fracture. The tensile stress-strain response of the 304L-VAR stainless steel exhibits strain rate dependence. The flow stress increases with increasing strain rate and is described with a power law. The strain-rate sensitivity is also strain-dependent, possibly due to thermosoftening caused by adiabatic heating at high strain rates. The 304L-VAR stainless steel shows significant ductility. The true strains at the onset of necking and at failure are determined. The results show that the true strains at both onset of necking and failure decrease with increasing strain rate. The true failure strains are approximately 200% at low strain rates but are significantly lower (~100%) at high strain rates. The transition of true failure strain occurs within the intermediate strain rate range between 10 -2 and 10 2 s -1 . A Boltzmann description is used to present the effect of nominal strain rate on true failure strain.

304L-VAR stainless Steel↗

Measurement, data analysis and prediction of pyrotechnic shock from pin-pullers and separation joints

To evaluate the potential for spacecraft damage caused by activation of pyrotechnic mechanisms, pyrotechnic shock tests were conducted on three configurations: pin-pullers on an orthogonal double Hopkinson bar arrangement, pin-pullers on a mock-up of the HALOE (Halogen Occultation Experiment) structure, and a section of separation joint on a single Hopkinson bar. Strains and accelerations were measured. The strains were converted to output stresses, forces and moments. Acceleration shock response spectra are presented for both acceleration- and force-time signals. The devices were attached to the Hopkinson bars with adaptors, which are typical of attachments used in practice. In order to predict the effect of the adaptors, finite element models of the adaptor-bar combinations were analyzed and results are presented with regard to grid size, time interval, and frequency range required to predict the response to pulses of 10 and 100 microsecond duration.

Evans, Maria J.↗

Mechanical behavior and texture evolution of WE43 magnesium-rare earth alloy in Split-Hopkinson Pressure Bar and Taylor Impact Cylinder Testing

Mechanical behavior and texture evolution of Mg rare-earth alloy WE43 is investigated for strain-rates 10 -3 /s to upwards of 10 5 /s for the two material conditions - as-cast (AC) and T6 age hardened, rolled plate (RT6). The high strain-rate behavior is tested using both Taylor cylinder impact tests (TC) and split Hopkinson pressure bar tests (SHB) and bulk textures are obtained using neutron diffraction. Unlike the quasi-static strained material, AC and RT6 SHB retained high hardening rates throughout the test, even up to 30% true strain. Moreover, the high strain-rate data revealed that the RT6 material has a much higher strength than the AC material, but similar hardening rates despite significantly different initial texture. The flow stress near yield increased up to I 0% for RT6 and up to 30% for AC as the strain-rate increased six orders of magnitude from quasi-static rates 10 -3 /s to 10 3 /s. Neither material exhibited significant plastic anisotropy over the broad range of strain rates, despite the fact that the RT6 material had a moderately strong initial texture. In the TC tests, the geometric cross-sectional changes and texture along the cylinder from the cylindrical sample foot to head are measured and from the neutron diffraction texture analysis, upper-bound estimates of twin volume fraction are obtained as well as dislocation density from analyzing diffraction peak broadening. Recorded geometrical changes along several loading directions show that the material has deformed remarkably homogeneously under impact. Analysis of deformed textures indicates that {101¯2} extension deformation twinning occurred in the RT6 condition over the range of strain rates, with an upper bound estimate of 40% twin volume fraction for approximately 0.10-0.25 true strain. The peak texture components after the impact have their c-axes closely aligned with the impact direction. As a result, these observations are presented and rationalized in the paper.

42 ENGINEERING↗

Experimental Techniques for Evaluating the Effects of Aging on Impact and High Strain Rate Properties of Triaxial Braided Composite Materials

An experimental program is underway to measure the impact and high strain rate properties of triaxial braided composite materials and to quantify any degradation in properties as a result of thermal and hygroscopic aging typically encountered during service. Impact tests are being conducted on flat panels using a projectile designed to induce high rate deformation similar to that experienced in a jet engine fan case during a fan blade-out event. The tests are being conducted on as-fabricated panels and panels subjected to various numbers of aging cycles. High strain rate properties are being measured using a unique Hopkinson bar apparatus that has a larger diameter than conventional Hopkinson bars. This larger diameter is needed to measure representative material properties because of the large unit cell size of the materials examined in this work. In this paper the experimental techniques used for impact and high strain rate testing are described and some preliminary results are presented for both as-fabricated and aged composites.

Pereira, J. Michael↗

HIGH-STRAIN RATE RESPONSE OF ULTRA-FINE GRAINED COPPER: EXPERIMENTS AND ANALYSIS

The high-strain rate response of ultra-fine grained (UFG) copper processed by Equal Channel Angular Pressing (ECAP) was characterized by reverse Taylor impact and Hopkinson-bar experiments. Two types of copper samples are tested using Hopkinson bar: (a) cylindrical samples to investigate the response at high strain-rates,(b) hat shaped samples to compare the shear band characteristics in UFG copper with the ones that have been studied in coarse grained samples. This can be attributed to the high strain-rate sensitivity of the fine grained FCC metals. Upon impact, the samples were found to undergo heat induced static recrystallization at a calculated temperature of 360K, indicating that the UFG copper is thermally unstable. Reverse Taylor tests were conducted on as-received OFHC Cu rod and ECAP specimens with sequential ECAP passes (2 and 8). The dynamic deformations of the samples are modeled using AUTODYN-2D and a modified Johnson-Cook constitutive equation was found to capture the dynamic response. Similar to the compression test results, the impacted front of the samples were found to recrystallize extensively and preferentially.

copper↗

Mechanical testing equipment for material characterization

A mechanical testing apparatus for a specimen is presented. The mechanical testing apparatus comprises a drop table system and a Hopkinson bar. The drop table system has a drop carriage. The Hopkinson bar is positioned parallel to a motion of the drop carriage and connected to the drop table system by the specimen.

36 MATERIALS SCIENCE↗

Numerical simulations of wave propagation in long bars with application to Kolsky bar testing

Material testing using the Kolsky bar, or split Hopkinson bar, technique has proven instrumental to conduct measurements of material behavior at strain rates in the order of 10 3 s -1 . Test design and data reduction, however, remain empirical endeavors based on the experimentalist's experience. Issues such as wave propagation across discontinuities, the effect of the deformation of the bar surfaces in contact with the specimen, the effect of geometric features in tensile specimens (dog-bone shape), wave dispersion in the bars and other particulars are generally treated using simplified models. The work presented here was conducted in Q3 and Q4 of FY14. The objective was to demonstrate the feasibility of numerical simulations of Kolsky bar tests, which was done successfully.

36 MATERIALS SCIENCE↗

Effects Of Pyrotechnically Generated Shocks

Research program provides better understanding of pyrotechnic phenomenon for design purposes. Evaluating potential for damage to spacecraft by activation of pyrotechnic mechanisms, pyrotechnic-shock tests conducted on three configurations: pin pullers on orthogonal double Hopkinson bar arrangement; pin pullers on mockup of Halogen Occultation Experiment (HALOE) structure; and section of separation joint on single Hopkinson bar. Strains and accelerations measured. Strains converted to output stresses, forces, and moments. Acceleration shock-response spectra obtained for both acceleration and force signals. Results of research useful to designers in making comparison and evaluation tests before committing to costly spacecraft hardware.

Bement, Laurence J.↗

Transient x-ray diffraction with simultaneous imaging under high strain-rate loading

Real time, in situ, multiframe, diffraction, and imaging measurements on bulk samples under high and ultrahigh strain-rate loading are highly desirable for micro- and mesoscale sciences. We present an experimental demonstration of multiframe transient x-ray diffraction (TXD) along with simultaneous imaging under high strain-rate loading at the Advanced Photon Source beamline 32ID. The feasibility study utilizes high strain-rate Hopkinson bar loading on a Mg alloy. The exposure time in TXD is 2–3 μs, and the frame interval is 26.7–62.5 μs. Various dynamic deformation mechanisms are revealed by TXD, including lattice expansion or compression, crystal plasticity, grain or lattice rotation, and likely grain refinement, as well as considerable anisotropy in deformation. Dynamic strain fields are mapped via x-ray digital image correlation, and are consistent with the diffraction measurements and loading histories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic Tensile Response of a Fe–49Co–2V Alloy at Various Strain Rates and Temperatures

Soft ferromagnetic alloys are often utilized in electromagnetic applications due to their desirable magnetic properties. In support of these applications, the ferromagnetic alloys are also required to bear mechanical load under various loading and environmental conditions. In this study, a Fe–49Co–2V alloy was dynamically characterized in tension with a Kolsky tension bar and a Drop–Hopkinson bar at various strain rates and temperatures. Dynamic tensile stress–strain curves of the Fe–49Co–2V alloy were obtained at strain rates ranging from 40 to 230 s -1 and temperatures from - 100 to 100 °C. All dynamic tensile stress–strain curves exhibited an initial linear elastic response to an upper yield followed by Lüders band response and then a nearly linear work-hardening behavior. The yield strength of this material was found to be sensitive to both strain rate and temperature, whereas the hardening rate was independent of strain rate or temperature. The Fe–49Co–2V alloy exhibited a feature of brittle fracture in tension under dynamic loading with no necking being observed.

36 MATERIALS SCIENCE↗

Dynamic High-Temperature Characterization of an Iridium Alloy in Compression at High Strain Rates

Iridium alloys have superior strength and ductility at elevated temperatures, making them useful as structural materials for certain high-temperature applications. However, experimental data on their high-temperature high-strain-rate performance are needed for understanding high-speed impacts in severe elevated-temperature environments. Kolsky bars (also called split Hopkinson bars) have been extensively employed for high-strain-rate characterization of materials at room temperature, but it has been challenging to adapt them for the measurement of dynamic properties at high temperatures. Current high-temperature Kolsky compression bar techniques are not capable of obtaining satisfactory high-temperature high-strain-rate stress-strain response of thin iridium specimens investigated in this study. We analyzed the difficulties encountered in high-temperature Kolsky compression bar testing of thin iridium alloy specimens. Appropriate modifications were made to the current high-temperature Kolsky compression bar technique to obtain reliable compressive stress-strain response of an iridium alloy at high strain rates (300 – 10000 s -1 ) and temperatures (750°C and 1030°C). Uncertainties in such high-temperature high-strain-rate experiments on thin iridium specimens were also analyzed. The compressive stress-strain response of the iridium alloy showed significant sensitivity to strain rate and temperature.

36 MATERIALS SCIENCE↗