Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High-Temperature Test Facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Oxygen-hydrogen thrusters for Space Station auxiliary propulsion systems

The feasibility and technology requirements of a low-thrust, high-performance, long-life, gaseous oxygen (GO2)/gaseous hydrogen (GH2) thruster were examined. Candidate engine concepts for auxiliary propulsion systems for space station applications were identified. The low-thrust engine (5 to 100 lb sub f) requires significant departure from current applications of oxygen/hydrogen propulsion technology. Selection of the thrust chamber material and cooling method needed or long life poses a major challenge. The use of a chamber material requiring a minimum amount of cooling or the incorporation of regenerative cooling were the only choices available with the potential of achieving very high performance. The design selection for the injector/igniter, the design and fabrication of a regeneratively cooled copper chamber, and the design of a high-temperature rhenium chamber were documented and the performance and heat transfer results obtained from the test program conducted at JPL using the above engine components presented. Approximately 115 engine firings were conducted in the JPL vacuum test facility, using 100:1 expansion ratio nozzles. Engine mixture ratio and fuel-film cooling percentages were parametrically investigated for each test configuration.

Berkman, D. K.↗

Design and preliminary results of a semitranspiration cooled (Lamilloy) liner for a high-pressure high-temperature combustor

A Lamilloy combustor liner was designed, fabricated and tested in a combustor at pressures up to 8 atmospheres. The liner was fabricated of a three layer Lamilloy structure and designed to replace a conventional step louver liner. The liner is to be used in a combustor that provides hot gases to a turbine cooling test facility at pressures up to 40 atmospheres. The Lamilloy liner was tested extensively at lower pressures and demonstrated lower metal temperatures than the conventional liner, while at the same time requiring about 40 percent less cooling air flow. Tests conducted at combustor exit temperatures in excess of 2200 K have not indicated any cooling or durability problems with the Lamilloy linear.

Wear, J. D.↗

Design and preliminary results of a semitranspiration cooled /Lamilloy/ liner for a high-pressure high-temperature combustor

A Lamilloy combustor liner has been designed, fabricated and tested in a combustor at pressures up to 8 atmospheres. The liner was fabricated of a three layer Lamilloy structure and designed to replace a conventional step-louver liner. The liner will be used in a combustor that provides hot gases to a turbine cooling test facility at pressures up to 40 atmospheres. The Lamilloy liner was tested extensively at lower pressures and demonstrated lower metal temperatures than the conventional liner, while at the same time requiring about 40 percent less cooling air flow. Tests conducted at combustor exit temperatures in excess of 2200 K have not indicated any cooling or durability problems with the Lamilloy liner.

Wear, J. D.↗

Study of the possibility of using solar radiant energy for welding and brazing metals

The solar spectrum at the surface of the earth is analyzed. A facility for creating concentrated solar radiant energy flux is described, and data on its energetic capabilities are presented. The technology of solar welding by the fusion technique and joining by high-temperature brazing is examined. The use of concentrated solar radiant energy for welding and brazing metals and alloys is shown. The results of mechanical tests and microscopic and macroscopic studies are presented.

Dvernyakov, V. S.↗

Heat-Transfer Coefficients for a Full-Scale Pebble-Bed Heater

Large quantities of high-temperature air are needed for work with hypersonic flight problems. At temperatures above 2500 degrees Reamur, where conventional heat exchangers have exceeded their material limits, regenerative pebble-bed exchangers may be used with high-temperature refractories. The design of such a heat exchanger requires the use of reliable heat-transfer coefficients for a packed bed. Considerable data are available on the subject, but they spread over two orders of magnitude at any one Reynolds number value. The facility from which the present data were obtained is used at the Lewis Research Center (NASA) for testing air-breathing engine components. The purpose of this work was to obtain heat-transfer data during the initial operation of the bed as a guide to the design of similar equipment. The facility was designed with a conservative estimate of the heat-transfer coefficient, and is shown schematically. Temperatures throughout the packing were measured continuously so that point values of the coefficient might be obtained.

Lancashire, R. B.↗

Properties of radio-frequency heated argon confined uranium plasmas

Pure uranium hexafluoride (UF6) was injected into an argon confined, steady state, rf-heated plasma within a fused silica peripheral wall test chamber. Exploratory tests conducted using an 80 kW rf facility and different test chamber flow configurations permitted selection of the configuration demonstrating the best confinement characteristics and minimum uranium compound wall coating. The overall test results demonstrated applicable flow schemes and associated diagnostic techniques were developed for the fluid mechanical confinement and characterization of uranium within an rf plasma discharge when pure UF6 is injected for long test times into an argon-confined, high-temperature, high-pressure, rf-heated plasma.

Source record↗

Technical accomplishments of the NASA Lewis Research Center, 1989

Topics addressed include: high-temperature composite materials; structural mechanics; fatigue life prediction for composite materials; internal computational fluid mechanics; instrumentation and controls; electronics; stirling engines; aeropropulsion and space propulsion programs, including a study of slush hydrogen; space power for use in the space station, in the Mars rover, and other applications; thermal management; plasma and radiation; cryogenic fluid management in space; microgravity physics; combustion in reduced gravity; test facilities and resources.

Source record↗

Unified constitutive materials model development and evaluation for high-temperature structural analysis applications

Unified constitutive material models were developed for structural analyses of aircraft gas turbine engine hot section components with particular application to an isotropic material used for combustor liners. Differential forms of models independently developed were considered in this study. These models combine the interactions of time-dependent (creep) and time-independent (plasticity) inelastic behavior of a material. Predicted stress-strain responses from these models were evaluated against cyclic isothermal and nonisothermal test results for uniaxial specimens of a nickel-base superalloy. The unified models were implemented in a nonlinear structural analysis code. Two unique NASA Lewis test facilities were used in the evaluation of the models for complex geometry specimens and evaluation of advanced temperature and high-temperature strain measurement instrumentation. Predicted nonlinear structural responses from one of the models for a flat plate and a segment of a conventional combustor liner are presented.

Thompson, R. L.↗

Recertification of the air and methane storage vessels at the Langley 8-foot high-temperature structures tunnel

This center operates a number of sophisticated wind tunnels in order to fulfill the needs of its researchers. Compressed air, which is kept in steel storage vessels, is used to power many of these tunnels. Some of these vessels have been in use for many years, and Langley is currently recertifying these vessels to insure their continued structural integrity. One of the first facilities to be recertified under this program was the Langley 8-foot high-temperature structures tunnel. This recertification involved (1) modification, hydrotesting, and inspection of the vessels; (2) repair of all relevant defects; (3) comparison of the original design of the vessel with the current design criteria of Section 8, Division 2, of the 1974 ASME Boiler and Pressure Vessel Code; (4) fracture-mechanics, thermal, and wind-induced vibration analyses of the vessels; and (5) development of operating envelopes and a future inspection plan for the vessels. Following these modifications, analyses, and tests, the vessels were recertified for operation at full design pressure (41.4 MPa (6000 psi)) within the operating envelope developed.

Hudson, C. M.↗

An experimental summary of plasma arc exposures of space shuttle high-temperature reusable surface insulation tile array with a single missing tile (conducted at the Ames Research Center)

A space shuttle high temperature reusable surface insulation (HRSI) tile array with a single missing or lost tile was exposed to a hot gas simulated reentry environment to investigate the heating conditions in and around the vicinity of the missing HRSI tile. Heat flux and pressure data for the lost tile condition were obtained by the use of a water cooled lost tile calibration model. The maximum aluminum substrate temperature obtained during the simulated reentry was 128 C (263 F). The lost tile calibration data indicated a maximum heat flux in the lost tile cavity region of 63 percent of the upstream reference value. This test was conducted at the Ames Research Center in the 20 MW semielliptical thermal protection system (TPS) pilot plasma arc test facility.

Galanter, S. A.↗

Laboratory-scale uranium RF plasma confinement experiments

An experimental investigation was conducted using 80 kW and 1.2 MW RF induction heater facilities to aid in developing the technology necessary for designing a self-critical fissioning uranium plasma core reactor. Pure uranium hexafluoride (UF6) was injected into argon-confined, steady-state, RF-heated plasmas in different uranium plasma confinement tests to investigate the characteristics of plamas core nuclear reactors. The objectives were: (1) to confine as high a density of uranium vapor as possible within the plasma while simultaneously minimizing the uranium compound wall deposition; (2) to develop and test materials and handling techniques suitable for use with high-temperature, high-pressure gaseous UF6; and (3) to develop complementary diagnostic instrumentation and measurement techniques to characterize the uranium plasma and residue deposited on the test chamber components. In all tests, the plasma was a fluid-mechanically-confined vortex-type contained within a fused-silica cylindrical test chamber. The test chamber peripheral wall was 5.7 cm ID by 10 cm long.

Roman, W. C.↗

Low-pressure performance of annular, high-pressure (40 atm) high-temperature (2480 K) combustion system

Experimental tests were conducted to develop a combustion system for a 40 atmosphere pressure, 2480 K exhaust gas temperature, turbine cooling facility. The tests were conducted in an existing facility with a maximum pressure capability of 10 atmospheres and where inlet air temperatures as high as 894 K could be attained. Exhaust gas temperatures were as high as 2365 K. Combustion efficiences were about 100 percent over a fuel air ratio range of 0.016 to 0.056. Combustion efficiency decreased at leaner and richer ratios when the inlet air temperature was 589 K. Data are presented that show the effect of fuel air ratio and inlet air temperature on liner metal temperature. Isothermal system pressure loss as a function of diffuser inlet Mach number is also presented. Data included exhaust gas pattern factors; unburned hydrocarbon, carbon monoxide, and oxides of nitrogen emission index values; and smoke numbers.

Wear, J. D.↗

Response of Inconel 617 superalloy to combined ground-based and STS reentry exposure

Inconel 617 is a nickel-based superalloy which is being considered for heat-shield applications because of its high-temperature strength, good oxidation resistance and high emittance of oxidized surfaces. While the effects of simulated reentry conditions on emittance and oxidation of Inconel 617 have been studied, the combined effects of the ground-based environment with sea salt exposure and the reentry environment have not been evaluated. Experimental results are presented to show the effects of environmental simulation including ground-based and reentry exposure on the emittance and oxidation of Inconel 617. Specimens were exposed to simulated reentry at a surface temperature of 2000 F in the Langley Research Center Hypersonic Materials Environmental Test System (HYMETS) Facility with and without alternate exposures to an atmospheric seashore environment or a laboratory sea salt environment. This paper presents emittance, mass loss, oxide chemistry, and alloy composition data for the specimens.

Clark, R. K.↗

Response of Inconel 617 superalloy to combined ground-based and STS reentry exposure

Inconel 617 is a nickel-based superalloy which is being considered for heat-shield applications because of its high-temperature strength, good oxidation resistance and high emittance of oxidized surfaces. While the effects of simulated reentry conditions on emittance and oxidation of Inconel 617 have been studied, the combined effects of the ground-based environment with sea salt exposure and the reentry environment have not been evaluated. Experimental results are presented to show the effects of environmental simulation including ground-based and reentry exposure on the emittance and oxidation of Inconel 617. Specimens were exposed to simulated reentry at a surface temperature of 2000 F in the Langley Research Center Hypersonic Materials Environmental Test System (HYMETS) Facility with and without alternate exposures to an atmospheric seashore environment or a laboratory sea salt environment. This paper presents emittance, mass loss, oxide chemistry, and alloy composition data for the specimens.

Clark, R. K.↗

High-temperature gaseous oxygen/hydrogen thrusters for space station

Efforts to determine the critical technologies necessary for the development of a high-temperature GO2/GH2 thruster are reviewed, for space station applications. Two types of thrust chambers are evaluated: one operable at high temperature and the other incorporating regenerative cooling. The high temperature chamber made of rhenium requires minimum cooling of the chamber wall, however, an oxidation barrier should be incorporated to prevent the rhenium thruster from readily oxidizing. The use of rhenium brought about a lower cost, lower weight, and simplicity of fabrication. The igniter-injector, the chamber, the test facility, and the test program are discussed. It is found that an obtained flow split of 58/42 increased the thruster performance from 3893 N-s/Kg to 4030 N-s/Kg for the same chamber pressure and overall mixture ratio. An increase in performance is also observed when the core mixture ratio is lowered. The thruster was tested for 1.9 hrs with no well degradation.

Dowdy, M. W.↗

Determination of the relative resistance to ignition of selected turbopump materials in high-pressure, high-temperature, oxygen environments, volume 1

Advances in the design of the liquid oxygen, liquid hydrogen engines for the Space Transportation System call for the use of warm, high-pressure oxygen as the driving gas in the liquid oxygen turbopump. The NASA Lewis Research Center requested the NASA White Sands Test Facility (WSTF) to design a test program to determine the relative resistance to ignition of nine selected turbopump materials: Hastelloy X, Inconel 600, Invar 36, Monel K-500, nickel 200, silicon carbide, stainless steel 316, and zirconium copper. The materials were subjected to particle impact and to frictional heating in high-pressure oxygen.

Stoltzfus, Joel M.↗

Acoustic levitation for high temperature containerless processing in space

New facilities for high-temperature containerless processing in space are described, including the acoustic levitation furnace (ALF), the high-temperature acoustic levitator (HAL), and the high-pressure acoustic levitator (HPAL). In the current ALF development, the maximum temperature capabilities of the levitation furnaces are 1750 C, and in the HAL development with a cold wall furnace they will exceed 2000-2500 C. The HPAL demonstrated feasibility of precursor space flight experiments on the ground in a 1 g pressurized-gas environment. Testing of lower density materials up to 1300 C has also been accomplished. It is suggested that advances in acoustic levitation techniques will result in the production of new materials such as ceramics, alloys, and optical and electronic materials.

Rey, C. A.↗

Computational method to predict thermodynamic, transport, and flow properties for the modified Langley 8-foot high-temperature tunnel

The Langley 8 foot high temperature tunnel (8 ft HTT) is used to test components of hypersonic vehicles for aerothermal loads definition and structural component verification. The test medium of the 8 ft HTT is obtained by burning a mixture of methane and air under high pressure; the combustion products are expanded through an axisymmetric conical contoured nozzle to simulate atmospheric flight at Mach 7. This facility was modified to raise the oxygen content of the test medium to match that of air and to include Mach 4 and Mach 5 capabilities. These modifications will facilitate the testing of hypersonic air breathing propulsion systems for a wide range of flight conditions. A computational method to predict the thermodynamic, transport, and flow properties of the equilibrium chemically reacting oxygen enriched methane-air combustion products was implemented in a computer code. This code calculates the fuel, air, and oxygen mass flow rates and test section flow properties for Mach 7, 5, and 4 nozzle configurations for given combustor and mixer conditions. Salient features of the 8 ft HTT are described, and some of the predicted tunnel operational characteristics are presented in the carpet plots to assist users in preparing test plans.

Venkateswaran, S.↗