Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High throughput”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

High-Throughput Screening of Li Solid-State Electrolytes With Bond Valence Methods and Graph Neural Networks

Li-based solid-state electrolyte (Li-SSE) materials enable safer, all-solid-state batteries but the computational search for candidates with favorable stability and Li-ion conductivity is challenging due to the size of the search space and the cost of evaluating transport properties with ab initio methods. We present a high-throughput screening approach for Li-SSE materials using a combination of bond-valence methods and graph neural networks. We demonstrate the screening approach with a dataset containing tens of thousands of Li-containing compounds. Furthermore, we combine the machine-learning screening procedure with an isovalent substitution scheme to generate and screen additional Li SSE candidates beyond existing databases. Finally, we discuss relative importances of geometric and bond-valence quantities in the training of graph neural networks, providing insight for future modeling of ionic conductivity in Li-SSE materials.

Materials discovery↗

Fluorescent Approaches to High Throughput Crystallography

We have shown that by covalently modifying a subpopulation, less than or equal to 1%, of a macromolecule with a fluorescent probe, the labeled material will add to a growing crystal as a microheterogeneous growth unit. Labeling procedures can be readily incorporated into the final stages of purification, and the presence of the probe at low concentrations does not affect the X-ray data quality or the crystallization behavior. The presence of the trace fluorescent label gives a number of advantages when used with high throughput crystallizations. The covalently attached probe will concentrate in the crystal relative to the solution, and under fluorescent illumination crystals show up as bright objects against a dark background. Non-protein structures, such as salt crystals, will not incorporate the probe and will not show up under fluorescent illumination. Brightly fluorescent crystals are readily found against less bright precipitated phases, which under white light illumination may obscure the crystals. Automated image analysis to find crystals should be greatly facilitated, without having to first define crystallization drop boundaries as the protein or protein structures is all that shows up. Fluorescence intensity is a faster search parameter, whether visually or by automated methods, than looking for crystalline features. We are now testing the use of high fluorescence intensity regions, in the absence of clear crystalline features or "hits", as a means for determining potential lead conditions. A working hypothesis is that kinetics leading to non-structured phases may overwhelm and trap more slowly formed ordered assemblies, which subsequently show up as regions of brighter fluorescence intensity. Preliminary experiments with test proteins have resulted in the extraction of a number of crystallization conditions from screening outcomes based solely on the presence of bright fluorescent regions. Subsequent experiments will test this approach using a wider range of proteins. The trace fluorescently labeled crystals will also emit with sufficient intensity to aid in the automation of crystal alignment using relatively low cost optics, further increasing throughput at synchrotrons.

Pusey, Marc L.↗

A High-Throughput, Adaptive FFT Architecture for FPGA-Based Space-Borne Data Processors

Historically, computationally-intensive data processing for space-borne instruments has heavily relied on ground-based computing resources. But with recent advances in functional densities of Field-Programmable Gate-Arrays (FPGAs), there has been an increasing desire to shift more processing on-board; therefore relaxing the downlink data bandwidth requirements. Fast Fourier Transforms (FFTs) are commonly used building blocks for data processing applications, with a growing need to increase the FFT block size. Many existing FFT architectures have mainly emphasized on low power consumption or resource usage; but as the block size of the FFT grows, the throughput is often compromised first. In addition to power and resource constraints, space-borne digital systems are also limited to a small set of space-qualified memory elements, which typically lag behind the commercially available counterparts in capacity and bandwidth. The bandwidth limitation of the external memory creates a bottleneck for a large, high-throughput FFT design with large block size. In this paper, we present the Multi-Pass Wide Kernel FFT (MPWK-FFT) architecture for a moderately large block size (32K) with considerations to power consumption and resource usage, as well as throughput. We will also show that the architecture can be easily adapted for different FFT block sizes with different throughput and power requirements. The result is completely contained within an FPGA without relying on external memories. Implementation results are summarized.

Nguyen, Kayla↗

Screening and Crystallization Plates for Manual and High-throughput Protein Crystal Growth

In one embodiment, a crystallization and screening plate comprises a plurality of cells open at a top and a bottom, a frame that defines the cells in the plate, and at least two films. The first film seals a top of the plate and the second film seals a bottom of the plate. At least one of the films is patterned to strongly pin the contact lines of drops dispensed onto it, fixing their position and shape. The present invention also includes methods and other devices for manual and high-throughput protein crystal growth.

Thorne, Robert E.↗

High-Throughput Top-Down and Bottom-Up Processes for Forming Single-Nanotube Based Architectures for 3D Electronics

We have developed manufacturable approaches to form single, vertically aligned carbon nanotubes, where the tubes are centered precisely, and placed within a few hundred nm of 1-1.5 micron deep trenches. These wafer-scale approaches were enabled by chemically amplified resists and inductively coupled Cryo-etchers for forming the 3D nanoscale architectures. The tube growth was performed using dc plasma-enhanced chemical vapor deposition (PECVD), and the materials used for the pre-fabricated 3D architectures were chemically and structurally compatible with the high temperature (700 C) PECVD synthesis of our tubes, in an ammonia and acetylene ambient. Tube characteristics were also engineered to some extent, by adjusting growth parameters, such as Ni catalyst thickness, pressure and plasma power during growth. Such scalable, high throughput top-down fabrication techniques, combined with bottom-up tube synthesis, should accelerate the development of PECVD tubes for applications such as interconnects, nano-electromechanical (NEMS), sensors or 3D electronics in general.

plasma-enhanced chemical vapor deposition (PECVD),↗

Achieving High Throughput for Data Transfer over ATM Networks

File-transfer rates for ftp are often reported to be relatively slow, compared to the raw bandwidth available in emerging gigabit networks. While a major bottleneck is disk I/O, protocol issues impact performance as well. Ftp was developed and optimized for use over the TCP/IP protocol stack of the Internet. However, TCP has been shown to run inefficiently over ATM. In an effort to maximize network throughput, data-transfer protocols can be developed to run over UDP or directly over IP, rather than over TCP. If error-free transmission is required, techniques for achieving reliable transmission can be included as part of the transfer protocol. However, selected image-processing applications can tolerate a low level of errors in images that are transmitted over a network. In this paper we report on experimental work to develop a high-throughput protocol for unreliable data transfer over ATM networks. We attempt to maximize throughput by keeping the communications pipe full, but still keep packet loss under five percent. We use the Bay Area Gigabit Network Testbed as our experimental platform.

Johnson, Marjory J.↗

PURE mRNA display and cDNA display provide rapid detection of core epitope motif via high‐throughput sequencing

The reconstructed in vitro translation system known as the PURE system has been used in a variety of cell‐free experiments such as the expression of native and de novo proteins as well as various display methods to select for functional polypeptides. We developed a refined PURE‐based display method for the preparation of stable messenger RNA (mRNA) and complementary DNA (cDNA)‐peptide conjugates and validated its utility for in vitro selection. Our conjugate formation efficiency exceeded 40%, followed by gel purification to allow minimum carry‐over of components from the translation system to the downstream assay enabling clean and efficient random peptide sequence screening. We chose the commercially available anti‐FLAG M2 antibody as a target molecule for validation. Starting from approximately 1.7 × 10(exp 12) random sequences, a round‐by‐round high‐throughput sequencing showed clear enrichment of the FLAG epitope DYKDDD as well as revealing consensus FLAG epitope motif DYK(D/L/N)(L/Y/D/N/F)D. Enrichment of core FLAG motifs lacking one of the four key residues (DYKxxD) indicates that Tyr(Y) and Lys (K) appear as the two key residues essential for binding. Furthermore, the comparison between mRNA display and cDNA display method resulted in overall similar performance with slightly higher enrichment for mRNA display. We also show that gel purification steps in the refined PURE‐based display method improve conjugate formation efficiency and enhance the enrichment rate of FLAG epitope motifs in later rounds of selection especially for mRNA display. Overall, the generalized procedure and consistent performance of two different display methods achieved by the commercially available PURE system will be useful for future studies to explore the sequence and functional space of diverse polypeptides.

cDNA display, FLAG epitope, mRNA display, peptide ↗

Space Link Extension (SLE) Emulation for High-Throughput Network Communication

As the data rate requirements for space communications increases, signicant stressis placed not only on the wireless satellite communication links, but also on the groundnetworks which forward data from end-users to remote ground stations. These wide areanetwork (WAN) connections add delay and jitter to the end-to-end satellite communicationlink, eects which can have signicant impacts on the wireless communication link. It isimperative that any ground communication protocol can react to these eects such that theground network does not become a bottleneck in the communication path to the satellite.In this paper, we present our SCENIC Emulation Lab testbed which was developed to testthe CCSDS SLE protocol implementations proposed for use on future NASA communica-tion networks. Our results show that in the presence of realistic levels of network delay,high-throughput SLE communication links can experience signicant data rate throttling.Based on our observations, we present some insight into why this data throttling happens,and trace the probable issue back to non-optimal blocking communication which is sup-ported by the CCSDS SLE API recommended practices. These issues were presented aswell to the SLE implementation developers which, based on our reports, developed a newrelease for SLE which we show xes the SLE blocking issue and greatly improves the pro-tocol throughput. In this paper, we also discuss future developments for our end-to-endemulation lab and how these improvements can be used to develop and test future spacecommunication technologies.

Networking↗

Space Link Extension (SLE) Emulation for High-Throughput Network Communication

As the data rate requirements for space communications increases, significant stress is placed not only on the wireless satellite communication links, but also on the ground networks which forward data from end-users to remote ground stations. These wide area network (WAN) connections add delay and jitter to the end-to-end satellite communication link, effects which can have significant impacts on the wireless communication link. It is imperative that any ground communication protocol can react to these effects such that the ground network does not become a bottleneck in the communication path to the satellite. In this paper, we present our SCENIC Emulation Lab testbed which was developed to test the CCSDS SLE protocol implementations proposed for use on future NASA communication networks. Our results show that in the presence of realistic levels of network delay, high-throughput SLE communication links can experience significant data rate throttling. Based on our observations, we present some insight into why this data throttling happens, and trace the probable issue back to non-optimal blocking communication which is sup-ported by the CCSDS SLE API recommended practices. These issues were presented as well to the SLE implementation developers which, based on our reports, developed a new release for SLE which we show fixes the SLE blocking issue and greatly improves the protocol throughput. In this paper, we also discuss future developments for our end-to-end emulation lab and how these improvements can be used to develop and test future space communication technologies.

Networking↗

Developing High-Throughput Organ-on-a-Chip Models to Investigate the Effects of Ionizing Radiation on the Central Nervous System

One of the main health risks in human space exploration is central nervous system (CNS) damage by ionizing radiation due to exposure to the galactic cosmic rays (GCRs). In animal models, irradiation with simulated GCRs or their components has been shown to cause neuronal damage and neuroinflammation associated with cognitive and behavioral dysfunction. In general, the extent of CNS damage is partially regulated by the blood-brain barrier (BBB), which enables immune cells to enter the CNS. The main cellular regulators of BBB permeability are astrocytes, which also modulate neuronal death, immune responses and oxidative stress, and thus could serve as a robust CNS-specific target for countermeasure development. However, studies on BBB permeability and astrocyte functions in regulating CNS responses to ionizing radiation have been limited, especially in human tissue/organ analogs. Therefore, we established a high-throughput 3D organ-on-a-chip system to study human CNS and BBB impairments in response to ionizing radiation, based on commercially available OrganoPlates (Mimetas, Inc.) seeded with primary or induced pluripotent stem cell-derived human cells. We investigated both immediate and delayed CNS responses to major GCR components: 0.15-0.5 Gy 250MeV/n 4-He, and 0.3-0.8 Gy 600 MeV/n 56-Fe; as well as to 0.5-1 Gy X-rays. We observed ionizing radiation-mediated increases in BBB permeability that was exacerbated by astrocyte presence and accompanied by morphological changes in endothelial cells and tight junctions, altered cytokine profile including TNFa upregulation, and increased oxidative stress. We also quantified irradiation-mediated changes in astrocyte activation and neuronal functions, revealing major astrocyte damage mediated by 600MeV/n 56-Fe particles. Thus, we demonstrate that deep space radiation may contribute to CNS damage by disrupting both astrocyte and endothelial cell components of the blood-brain barrier. Our next steps include mapping and validating the transcriptomic changes induced by simulated GCRs and their components in human CNS models. Ultimately, we aim to uncover potential novel targets for countermeasure developments to mitigate CNS damage in long duration spaceflight.

Radiation↗

Microfabrication of a High-Throughput Nanochannel Delivery/Filtration System

A microfabrication process is proposed to produce a nanopore membrane for continuous passive drug release to maintain constant drug concentrations in the patient s blood throughout the delivery period. Based on silicon microfabrication technology, the dimensions of the nanochannel area, as well as microchannel area, can be precisely controlled, thus providing a steady, constant drug release rate within an extended time period. The multilayered nanochannel structures extend the limit of release rate range of a single-layer nanochannel system, and allow a wide range of pre-defined porosity to achieve any arbitrary drug release rate using any preferred nanochannel size. This membrane system could also be applied to molecular filtration or isolation. In this case, the nanochannel length can be reduced to the nanofabrication limit, i.e., 10s of nm. The nanochannel delivery system membrane is composed of a sandwich of a thin top layer, the horizontal nanochannels, and a thicker bottom wafer. The thin top layer houses an array of microchannels that offers the inlet port for diffusing molecules. It also works as a lid for the nanochannels by providing the channels a top surface. The nanochannels are fabricated by a sacrificial layer technique that obtains smooth surfaces and precisely controlled dimensions. The structure of this nanopore membrane is optimized to yield high mechanical strength and high throughput.

Ferrari, Mauro↗

The High Throughput X-ray Spectroscopy (HTXS) Mission

The HTXS mission concept combines large effective area (approximately 15,000 sq cm at 1 keV), high spectral resolution (E/Delta(E) approximately 300-3000), and broad energy bandpass (0.25-40 keV and possibly up to 100 keV) by using replicated optics together with a complement of spectroscopic instrumentation including reflection gratings readout by charge-coupled device detectors (CCDs), quantum micro-calorimeters, and cadmium zinc telluride (CZT) or comparable high energy detectors. An essential feature of this concept involves minimization of cost (approximately $350M for development and approximately $500-600M including launches) and risk by building six identical modest satellites to achieve the large area. Current mission and technology studies are targeted towards a new start in the 2002 timeframe, with first launch around 2005-2006. The HTXS mission represents a major advance, providing as much as a factor of 100 increase in sensitivity over currently planned high resolution X ray spectroscopy missions. HTXS will mark the start of a new era when high quality X ray spectra will be obtained for all classes of X ray sources, over a wide range of luminosity and distance. With its increased capabilities, HTXS will address many fundamental astrophysics questions such as the origin and distribution of the elements from carbon to zinc, the formation and evolution of clusters of galaxies, the validity of general relativity in the strong gravity limit, the evolution of supermassive black holes in active galactic nuclei, the details of supernova explosions and their aftermath, and the mechanisms involved in the heating of stellar coronae and driving of stellar winds.

White, N. E.↗

(abstract) A High Throughput 3-D Inner Product Processor

A particularily challenging image processing application is the real time scene acquisition and object discrimination. It requires spatio-temporal recognition of point and resolved objects at high speeds with parallel processing algorithms. Neural network paradigms provide fine grain parallism and, when implemented in hardware, offer orders of magnitude speed up. However, neural networks implemented on a VLSI chip are planer architectures capable of efficient processing of linear vector signals rather than 2-D images. Therefore, for processing of images, a 3-D stack of neural-net ICs receiving planar inputs and consuming minimal power are required. Details of the circuits with chip architectures will be described with need to develop ultralow-power electronics. Further, use of the architecture in a system for high-speed processing will be illustrated.

imaging parallel processing algorithms linear vect↗

Design considerations for a monolithic, GaAs, dual-mode, QPSK/QASK, high-throughput rate transceiver

A monolithic, GaAs, dual mode, quadrature amplitude shift keying and quadrature phase shift keying transceiver with one and two billion bits per second data rate is being considered to achieve a low power, small and ultra high speed communication system for satellite as well as terrestrial purposes. Recent GaAs integrated circuit achievements are surveyed and their constituent device types are evaluated. Design considerations, on an elemental level, of the entire modem are further included for monolithic realization with practical fabrication techniques. Numerous device types, with practical monolithic compatability, are used in the design of functional blocks with sufficient performances for realization of the transceiver.

Kot, R. A.↗

Informatics and High Throughput Screening of Thermophysical Properties

The combination of computer-aided experiments with computational modeling enables a new class of powerful tools for materials research. A non-contact method for measuring density, thermal expansion, and creep of undercooled and high-temperature materials has been developed, using electrostatic levitation and optical diagnostics, including digital video. These experiments were designed to take advantage of the large volume of data (many gigabytes/experiment, terabytes/campaign) to gain additional information about the samples. For example, using sub-pixel interpolation to measure about 1000 vectors per image of the sample's surface allows the density of an axisymmetric sample to be determined to an accuracy of about 200 ppm (0.02%). A similar analysis applied to the surface shape of a rapidly rotating sample is combined with finite element modeling to determine the stress-dependence of creep in the sample in a single test. Details of the methods for both the computer-aided experiments and computational models will be discussed.

Hyers, Robert W.↗

Link Analysis of High Throughput Spacecraft Communication Systems for Future Science Missions

NASA's plan to launch several spacecraft into low Earth Orbit (LEO) to support science missions in the next ten years and beyond requires down link throughput on the order of several terabits per day. The ability to handle such a large volume of data far exceeds the capabilities of current systems. This paper proposes two solutions, first, a high data rate link between the LEO spacecraft and ground via relay satellites in geostationary orbit (GEO). Second, a high data rate direct to ground link from LEO. Next, the paper presents results from computer simulations carried out for both types of links taking into consideration spacecraft transmitter frequency, EIRP, and waveform; elevation angle dependent path loss through Earths atmosphere, and ground station receiver GT.

Antennas↗

Link Analysis of High Throughput Spacecraft Communication Systems for Future Science Missions

NASA's plan to launch several spacecrafts into low Earth Orbit (LEO) to support science missions in the next ten years and beyond requires down link throughput on the order of several terabits per day. The ability to handle such a large volume of data far exceeds the capabilities of current systems. This paper proposes two solutions, first, a high data rate link between the LEO spacecraft and ground via relay satellites in geostationary orbit (GEO). Second, a high data rate direct to ground link from LEO. Next, the paper presents results from computer simulations carried out for both types of links taking into consideration spacecraft transmitter frequency, EIRP, and waveform; elevation angle dependent path loss through Earths atmosphere, and ground station receiver GT.

Amplifier↗

High throughput narrowband 83.4 nm self-filtering camera

Photometric imaging of ionospheric/magnetospheric O II emission at 83.4 nm is a primary objective for mapping the distribution of O(+) ions. However, instrumental sensitivity has been a major barrier to realizing this goal. We report an instrumental design employing a low focal ratio three-mirror camera where the reflecting surfaces act as both narrowband reflection filters at 83.4 nm and as a high quality imaging system. The design includes coatings with reflectances that are relatively insensitive to the angle of incidence of light. The peak reflectance per mirror is more than 60 percent at 83.4 nm with the average reflectance for out-of-band wavelengths of less than 5 percent. The net reflective transmission for the three mirrors is greater than 20 percent with 6.8 nm bandwidth and 0.01 percent maximum transmittance for out-of-band wavelengths. The transmittance at 30.4 nm is 0.03 percent at 58.4 nm 0.05 percent, and at 121.6 nm 0.004 percent. When used with an open microchannel plate detector, contamination by H Ly-alpha is essentially eliminated. With this spectral purity and effective elimination of major contributors to background contamination noise, a signal-to-noise ratio (excluding detector noise) of 10 is achievable for a 0.01 R signal in 8.8 seconds for the full 6 deg field-of-view.

Zukic, Muamer↗