Engineering PapersSearch

SEARCH · Engineering Papers

Results for “High Level Trigger”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A machine learning based approach to online electron reconstruction at CLAS12

Online reconstruction is key for monitoring purposes and real time analysis in High Energy and Nuclear Physics experiments. A necessary component of reconstruction algorithms is particle identification that combines information left by a particle passing through several detector components to identify the particle’s type. Of particular interest to electro-production Nuclear Physics experiments such as CLAS12 is electron identification which is used to trigger data recording. A machine learning approach was developed for CLAS12 to reconstruct and identify electrons by combining raw signals at the data acquisition level from several detector components. Here, this approach achieves an electron identification purity above 75% whilst retaining an efficiency close to 100%. The machine learning tools are capable of running at high rates exceeding the data acquisition rates and will allow electron reconstruction in real-time. This work enhances online analyses and monitoring and can contribute to improved triggering at CLAS12. This machine learning driven approach will also be crucial for experiments aiming to transition to streaming readout operations where online reconstruction will be a key component of the data taking paradigm.

Artificial intelligence

Module Testing Procedures and Results for the CMS Phase-2 Outer Tracker Upgrade at Fermilab

The High-Luminosity LHC (HL-LHC) will operate at significantly increased luminosities and is expected to deliver about 3000 $fb^{-1}$ of proton-proton collision data at $\sqrt{s}=14$ TeV over a decade of operation. To maintain efficient tracking and triggering performance under high pileup and radiation conditions, the CMS experiment is upgrading its tracking detector for Phase-2 operations. The upgraded Outer Tracker (OT) will consist of Pixel-Strip (PS) and Strip-Strip (2S) silicon modules capable of providing tracking information to the Level-1 trigger at 40 MHz. Production and qualification of OT modules have been ongoing for about one year across several assembly and testing centers in the US, Europe, India, and Pakistan, requiring extensive testing to ensure stable operation in the HL-LHC environment. Fermilab is responsible for the production and testing of a significant fraction of the OT modules. The testing activities include IV characterization of silicon sensors, noise and pedestal measurements, verification of communication between module components, and burn-in studies using cold-box systems operated under controlled thermal conditions. Results from module testing and qualification studies performed during production will be presented.

Baradia, Sweta [UC, Davis (main)]

Design and Construction of the CMS Outer Tracker for the Phase-2 Upgrade

The High Luminosity LHC (HL-LHC) is expected to deliver an integrated luminosity of 3000-4000~fb$^{-1}$ after 10 years of operation with peak instantaneous luminosity reaching about 5-7.5$\times10^{34}$cm$^{-2}$s$^{-1}$. During Long Shutdown 3, several components of the CMS detector will undergo major changes, called Phase-2 upgrades, to be able to operate in the challenging environment of the HL-LHC. The current CMS tracker will be replaced. The Phase-2 Outer Tracker (OT) will have high radiation tolerance, higher granularity, and the capability to handle higher data rates. Moreover, the OT will provide tracking information to the Level-1 trigger, for the first time at hadron colliders, allowing trigger rates to be kept at a sustainable level without sacrificing physics potential. For this, the OT will be made of modules with two closely spaced silicon sensors read out by front-end ASICs, which can correlate hits in the two sensors creating short track segments (stubs), used for tracking in the L1 track finder. The modules come in two flavors: strip-strip (2S) and pixel-strip (PS), containing different sensor configurations and multiple ASICs. This contribution will present the design of the Phase-2 OT, the first results with pre-production devices, and the quality assurance procedures used to ensure the functionality of the modules: from fulfilling the precision specification of the module assembly procedure to ensuring the proper communication among the module's ASICs.

43 PARTICLE ACCELERATORS

Rapid Inference of Logic Gate Neural Networks for Anomaly Detection in High Energy Physics

The increasing data rates and complexity of detectors at the Large Hadron Collider (LHC) necessitate fast and efficient machine learning models, particularly for rapid selection of what data to store, known as triggering. Building on recent work in differentiable logic gates, we present a public implementation of a Convolutional Differentiable Logic Gate Neural Network (CLGN). We apply this to detecting anomalies at the Level-1 Trigger at CMS using public data from the CICADA project. We demonstrate that the CLGN achieves physics performance on par with or superior to conventional quantized neural networks. We also synthesize an LGN for a Field-Programmable Gate Array (FPGA) and show highly promising FPGA characteristics, notably zero Digital Signal Processor (DSP) resource usage. This work highlights the potential of logic gate networks for high-speed, on-detector inference in High Energy Physics and beyond.

FOS: Physical sciences

Performance Analysis of Phase 2 Tracker Upgrade PS Module Before and After Irradiation

The Large Hadron Collider will undergo a luminosity upgrade targeting a peak instantaneous luminosity ranging from 5 up to 7.5$\times10^{34}$\,cm$^{-2}$s$^{-1}$. The ambitious goal of the High Luminosity LHC is to achieve a total of 3000--4000\,fb$^{-1}$ of proton-proton collisions at a center-of-mass energy of 14\,TeV. To cope with such challenging environmental conditions, the outer tracker of the CMS experiment will be upgraded using closely spaced silicon sensors (pixels and strips) to provide tracking information at the Level-1 trigger. A PS-Module, composed of both a pixel and a strip sensor, was tested at the Fermilab Test-Beam Facility to evaluate its ability to provide accurate tracking information, particle momentum discrimination capabilities and optimal performance at the irradiation levels expected after being exposed to the harsh conditions of the High Luminosity LHC. The results of the test and the comparison of the module performance before and after irradiation will be presented in this poster.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Performance Analysis of Phase 2 Tracker Upgrade PS Module Before and After Irradiation

The Large Hadron Collider will undergo a luminosity upgrade targeting a peak instantaneous luminosity ranging from 5 up to 7.5$\times10^{34}$\,cm$^{-2}$s$^{-1}$. The ambitious goal of the High Luminosity LHC is to achieve a total of 3000--4000\,fb$^{-1}$ of proton-proton collisions at a center-of-mass energy of 14\,TeV. To cope with such challenging environmental conditions, the outer tracker of the CMS experiment will be upgraded using closely spaced silicon sensors (pixels and strips) to provide tracking information at the Level-1 trigger. A PS-Module, composed of both a pixel and a strip sensor, was tested at the Fermilab Test-Beam Facility to evaluate its ability to provide accurate tracking information, particle momentum discrimination capabilities and optimal performance at the irradiation levels expected after being exposed to the harsh conditions of the High Luminosity LHC. The results of the test and the comparison of the module performance before and after irradiation will be presented in this poster.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Performance Analysis of Phase 2 Tracker Upgrade Ps Module before and after Irradiation

The Large Hadron Collider will undergo a luminosity upgrade targeting a peak instantaneous luminosity ranging from 5–7.5×1034 cm−2s−1. The ambitious goal of the High Luminosity LHC is to achieve a total of 3000–4000 fb−1 of proton-proton collisions at a center-of-mass energy of 13–14 TeV by 2029. To cope with such challenging environmental conditions, the outer tracker of the CMS experiment will be upgraded using closely spaced silicon sensors (pixels and strips) to provide tracking information at the Level-1 trigger. A PS-Module, composed of both a pixel and a strip sensor, was tested at the Fermilab Test-Beam Facility to evaluate its ability to provide accurate tracking information, Pt discrimination capabilities, and optimal performance at the irradiation levels expected after being exposed to the harsh conditions of the High Luminosity LHC. The results of the test and the comparison of the module performance before and after irradiation will be presented in this poster

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Beam Test Characterization of an Irradiated Pixel-Strip Module for HL_LHC CMS Tracker Upgrade

A new tracker, for the CMS detector at The Large Hadron Collider, will be built to address the demands of the High Luminosity upgrade which aims to achieve peak instantaneous luminosities from 5 up to 7.5 10^34 cm^-2 s^-1 and an integrated luminosity of 3000 4000 fb^-1 at a center of mass energy of 14 TeV. To meet the resulting challenges, the CMS experiment is changing its outer tracker silicon modules to include tracking capabilities at the Level-1 trigger. As part of this upgrade effort, a prototype module, combining both pixel and strip sensors (PS-module), was irradiated and subsequently tested at the Fermilab Test Beam and Irradiation facilities. These tests evaluated the module's ability to maintain precise tracking, effective particle momentum discrimination, and consistent performance when exposed to the radiation levels expected in the High Luminosity LHC environment. Results from these studies are presented with a focus on comparing the module's performance before and after irradiation.

43 PARTICLE ACCELERATORS

Coastal groundwater salinization impairs tree carbon–water balance

How coastal forest productivity varies with local nutrient availability and water supply remains a knowledge gap under climate change. In a two-decade field experiment manipulating fertilization and density in coastal pine forests, we show that a decade of growth enhancement by simulated sedimentary nutrient inputs has resulted in a striking reversal in growth and increased mortality risk as drought and sea level rise progressed. Recent groundwater salinization has further triggered a shift from nutrient to water limitation, causing severe stomatal closure and decoupling of tree carbon–water balance, which induces a negative intrinsic water use efficiency (iWUE)–growth relationship. Higher tree iWUE predicted sharper tree growth declines, and both nutrient enrichment and high stand density amplified this feedback, increasing the risk of hydraulic failure and mortality. These results suggest that a transient nutrient-stimulatory effect could drive further coastal forest degradation due to heightened belowground saltwater stress under sea-level rise.

Climate-change ecology

Evaluating Radiation Impact on Transmon Qubits in Above and Underground Facilities

Superconducting qubits can be sensitive to abrupt energy deposits caused by cosmic rays and ambient radioactivity. Previous studies have focused on understanding possible correlated effects over time and distance due to cosmic rays. In this study, for the first time, we directly compare the response of a transmon qubit measured initially at the Fermilab SQMS above-ground facilities and then at the deep underground Gran Sasso Laboratory (INFN-LNGS, Italy). We observe same average qubit lifetime T$_1$ of roughly 80 microseconds at above and underground facilities. We then apply a fast decay detection protocol and investigate the time structure, sensitivity and relative rates of triggered events due to radiation versus intrinsic noise, comparing above and underground performance of several high-coherence qubits. Using gamma sources of variable activity we calibrate the response of the qubit to different levels of radiation in an environment with minimal background radiation. Results indicate that qubits respond to a strong gamma source and it is possible to detect particle impacts. However, when comparing above and underground results, we do not observe a difference in radiation induced-like events for these sapphire and niobium-based transmon qubits. We conclude that the majority of these events are not radiation related and to be attributed to other noise sources which by far dominate single qubit errors in modern transmon qubits.

Roy, Tanay

Evaluating Radiation Impact on Transmon Qubits Using a Fast Decay Protocol in Above and Underground Laboratories

Superconducting qubits can be sensitive to sudden energy deposits caused by ambient radioactivity and cosmic rays. Previous studies have focused on understanding possible correlated effects over time and distance due to this radiation. In this study‚ for the first time‚ we directly compare the response of a transmon qubit measured initially at the SQMS above-ground facility (Fermilab‚ Illinois‚ USA) and then at the deep underground Gran Sasso Laboratory (INFN-LNGS‚ Italy). We observe the same average qubit lifetime of roughly 80 microseconds at both facilities. We then apply a fast decay detection protocol and investigate the time structure and relative rates of triggered events due to radiation versus intrinsic noise‚ comparing the above and underground performance of several high-coherence qubits. Using gamma sources of variable intensity we calibrate the response of the qubit to different levels of radiation in an environment with minimal background radiation. Results indicate that qubits respond to a strong gamma source‚ and it is possible to detect particle impacts. However‚ we do not observe a difference in radiation-induced-like events when comparing the above and underground results for niobium-based transmon qubits with sapphire substrates. We conclude that the majority of these events are not radiation-related and are attributed to other noise sources‚ which by far dominate single-qubit errors in modern transmon qubits. [1] Dominicis‚ Roy et al. arXiv:2405.18355

Roy, Tanay

Design and validation of a nanosecond short-wave infrared streak camera using gaseous detonation experiments

A custom short-wave infrared (SWIR) galvanometric streak camera was developed to provide nanosecond- scale, time-resolved optical diagnostics. The system was designed as a compact, mechanically driven alternative to traditional tube-based streak cameras, using a galvanometer mirror and multiple-reflection optical path to achieve high temporal resolution while maintaining electronic synchronization for trigger sequencing. Temporal resolution achieved 139.5 ns/px, allowing direct conversion of image-slope gradients to physical wave velocities. The instrument was validated using hydrogen-oxygen-argon detonations within a modular detonation tube, capturing transient emission structures and post-detonation decay behavior with microsecond precision. Although signal levels in filtered configurations were limited by lens transmission and detector sensitivity, the system successfully resolved intensity rise and decay characteristics across 10-60 % argon mixtures. The observed trends demonstrate the feasibility of compact galvanometer-based streak systems for high-speed SWIR imaging in reactive environments!

42 ENGINEERING

Growth and characterization of high-quality Zr doped AlN epilayers

AlN stands out for its remarkable figures of merit for electronic and photonic devices, attributed to its ultrawide bandgap of ∼6.1 eV and an exceptionally high critical field of ∼15 MV/cm. More recently, zirconium (Zr) doped AlN (AlN:Zr) has also been identified as a promising material platform for the exploration of solid-state qubits for quantum information and technology, high performance piezoelectric acoustic wave resonators, and optically triggered ultrafast power switching devices facilitated by optically activating Zr related impurities. Despite the significant potential, the ability for producing AlN:Zr epitaxial structures has yet to be established. In this study, we have achieved AlN:Zr epilayers with a high Zr doping level [NZr] of up to 1020 cm−3 using industrial standard metal-organic chemical vapor deposition growth technique. High crystalline quality of AlN:Zr was confirmed by x-ray diffraction, revealing a narrow full width at half maximum of the (002) rocking curve at 216 arcsec for 1.8 μm thick epilayers deposited on sapphire at [NZr]=1020 cm−3. Zr doping was observed to slightly increase the c-lattice constant to 4.992 Å for AlN:Zr (at [NZr]=1020 cm−3) compared to 4.980 Å for undoped AlN. X-ray photoelectron spectroscopy measurement results verified the substitution of Zr at the Al site (ZrAl). The formation of (ZrAl–VN) complexes, which are predicted to possess all the desired properties required by quantum qubits, was confirmed through optical absorption studies. The realization of high-quality AlN:Zr epilayers significantly broadens the scope of technologically significant device applications for AlN.

36 MATERIALS SCIENCE

Environmental Conditions Affecting Global Mesoscale Convective System Occurrence

Abstract The ERA5 environments of mesoscale convective systems (MCSs), tracked from satellite observations, are assessed over a 20-yr period. The use of a large set of MCS tracks allows us to robustly test the sensitivity of the results to factors such as region, latitude, and diurnal cycle. We aim to provide novel information on environments of observed MCSs for assessments of global atmospheric models and to improve their ability to simulate MCSs. Statistical analysis of all tracked MCSs is performed in two complementary ways. First, we investigate the environments when an MCS has occurred at different spatial scales before and after MCS formation. Several environmental variables are found to show marked changes before MCS initiation, particularly over land. The vertically integrated moisture flux convergence shows a robust signal across different regions and when considering MCS initiation diurnal cycle. We also found spatial scale dependence of the environments between 200 and 500 km, providing new evidence of a natural length scale for use with MCS parameterization. In the second analysis, the likelihood of MCS occurrence for given environmental conditions is evaluated, by considering all environments and determining the probability of being in an MCS core or shield region. These are compared to analogous non-MCS environments, allowing discrimination between conditions suitable for MCS and non-MCS occurrence. Three environmental variables are found to be useful predictors of MCS occurrence: total column water vapor, midlevel relative humidity, and total column moisture flux convergence. Such relations could be used as trigger conditions for the parameterization of MCSs, thereby strengthening the dependence of the MCS scheme on the environment. Significance Statement Large storm systems called mesoscale convective systems form across Earth. These are collections of thunderstorms, with associated high-level clouds that produce substantial, lighter rainfall and modulate Earth’s energy balance. They produce hazardous weather conditions, such as floods and high winds, and are responsible for a high percentage of rainfall in many regions globally. We investigate the environmental conditions under which they form, so that we can understand the spatial extent of the environment which is important for their formation, and also where and when the effects of these storms might be felt. The novel information generated here should help improve the representation of these storms in weather and climate models, improving the prediction of rainfall, thunderclouds, and high-level clouds.

54 ENVIRONMENTAL SCIENCES

Dosimetric and biological impact of activity extravasation of radiopharmaceuticals in PET imaging

The increasing use of nuclear medicine and PET imaging has intensified scrutiny of radiotracer extravasation. To our knowledge, this topic is understudied but holds great potential for enhancing our understanding of extravasation in clinical PET imaging. This work aims to (1) quantify the absorbed doses from radiotracer extravasation in PET imaging, both locally at the site of extravasation and with the extravasation location as a source of exposure to bodily organs and (2) assess the biological ramifications within the injection site at the cellular level. A radiation dosimetry simulation was performed using a whole-body 4D Extended Cardiac-Torso (XCAT) phantom embedded in the GATE Monte Carlo platform. A 10-mCi dose of 18 F-FDG was chosen to simulate a typical clinical PET scan scenario, with 10% of the activity extravasated in the antecubital fossa of the right arm of the phantom. The extravasation volume was modeled as a 5.5 mL rectangle in the hypodermal layer of skin. Absorbed dose contributions were calculated for the first two half-lives, assuming biological clearance thereafter. Dose calculations were performed as absorbed doses at the organ and skin levels. Energy deposition was simulated both at the local extravasation site and in multiple organs of interest and converted to absorbed doses based on their respective masses. Each simulation was repeated ten times to estimate Monte Carlo uncertainties. Biological impacts on cells within the extravasated volume were evaluated by randomizing cells and exposing them to a uniform radiation source of 18 F and 68 Ga. Particle types, their energies, and direction cosines were recorded in phase space files using a separate Geant4 simulation to characterize their entry into the nucleus of the cellular volume. Subsequently, the phase space files were imported into the TOPAS-nBio simulation to assess the extent of DNA damage, including double-strand breaks (DSBs) and single-strand breaks (SSBs). Organ-level dosimetric estimations are presented for 18 F and 68 Ga radionuclides in various organs of interest. With 10% extravasation, the hypodermal layer of the skin received the highest absorbed dose of 1.32 ± 0.01 Gy for 18 F and 0.99 ± 0.01 Gy for 68 Ga. The epidermal and dermal layers received absorbed doses of 0.07 ± 0.01 Gy and 0.13 ± 0.01 Gy for 18 F, and 0.14 ± 0.01 Gy and 0.29 ± 0.01 Gy for 68 Ga, respectively. In the extravasated volume, 18 F caused an average absorbed dose per nucleus of 0.17 ± 0.01 Gy, estimated to result in 10.58 ± 0.50 DSBs and 268.11 ± 12.43 SSBs per nucleus. For 68 Ga, the absorbed dose per nucleus was 0.11 ± 0.01 Gy, leading to an estimated 6.49 ± 0.34 DSBs and 161.24 ± 8.12 SSBs per nucleus. Absorbed doses in other organs were on the order of micro-gray (µGy). The likelihood of epidermal erythema resulting from extravasation during PET imaging is low, as the simulated absorbed doses to the epidermis remain below the thresholds that trigger such effects. Moreover, the organ-level absorbed doses were found to be clinically insignificant across various simulated organs. The minimal DNA damage at the extravasation site suggests that long-term harm, such as radiation-induced carcinogenesis, is highly unlikely.

DNA strand breaks

Pixel-Strip Module Testing and Performance Analysis for the CMS Phase-2 Outer Tracker Upgrade

In response to the demanding environment of the High-Luminosity Large Hadron Collider (HL-LHC), the Compact Muon Solenoid (CMS) Experiment's Outer Tracker is being replaced with a lighter, higher-granularity, radiation-tolerant silicon detector capable of providing tracking information directly to the Level-1 trigger system. The new Outer Tracker consists of Pixel-Strip (PS) and Strip-Strip (2S) transverse momentum (pT) modules, which are assembled and tested at, among other centers, Fermilab's Silicon Detector Facility. PS modules consist of a pixel sensor, a strip sensor, and multiple application-specific integrated circuits (ASICs). This poster studies the performance of MaPSAs, silicon macro-pixel sensors bump-bonded to 16 macro-pixel ASICS. It presents the testing procedures for MaPSAs and MaPSA-strip sensor sub-assemblies, as well as the results of calibration and performance studies of two PS modules before and after irradiation. These results assess the impact of irradiation on module performance, providing insight into the modules' expected performance in the HL-LHC environment.

Kimrey, Emerson [Scripps College]

Intelligent experiments through real-time AI: Fast Data Processing and Autonomous Detector Control for sPHENIX and future EIC detectors

This R&D project, initiated by the DOE Nuclear Physics AI-Machine Learning initiative in 2022, leverages AI to address data processing challenges in high-energy nuclear experiments (RHIC, LHC, and future EIC). Our focus is on developing a demonstrator for real-time processing of high-rate data streams from sPHENIX experiment tracking detectors. The limitations of a 15 kHz maximum trigger rate imposed by the calorimeters can be negated by intelligent use of streaming technology in the tracking system. The approach efficiently identifies low momentum rare heavy flavor events in high-rate p+p collisions (3MHz), using Graph Neural Network (GNN) and High Level Synthesis for Machine Learning (hls4ml). Success at sPHENIX promises immediate benefits, minimizing resources and accelerating the heavy-flavor measurements. The approach is transferable to other fields. For the EIC, we develop a DIS-electron tagger using Artificial Intelligence - Machine Learning (AI-ML) algorithms for real-time identification, showcasing the transformative potential of AI and FPGA technologies in high-energy nuclear and particle experiments real-time data processing pipelines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Convective Biases in the US DOE Global Storm‐Resolving Model: Insights From Regionally Refined Simulations During the CACTI Campaign

Accurately simulating convective processes in complex terrain remains a critical challenge for global storm-resolving models (GSRMs). This study systematically evaluates moist convective biases in the Regionally Refined Mesh configuration of the U.S. Department of Energy Simple Cloud-Resolving E3SM Atmosphere Model (RRM-SCREAM) using comprehensive observations and large-eddy simulations from the Cloud, Aerosol, and Complex Terrain Interactions (CACTI) campaign in the mountainous area of central Argentina. Comparisons of simulations with high-resolution observations and reanalysis data indicate that RRM-SCREAM effectively captures large-scale meteorological patterns, including regional atmospheric gradients and diurnal variability. However, RRM-SCREAM disproportionately produces smaller precipitation clusters referred to as “popcorn convection,” and exaggerated rainfall intensities compared to observations and reference models. Detailed examination of a representative orographic shallow-to-deep convective transition case shows that RRM-SCREAM delays initial shallow convection growth due to lower-tropospheric dryness and sustained convective inhibition, but once triggered, deep convection becomes overly vigorous with excessively strong vertical velocities and elevated cloud ice content, linked to a thermodynamic structure characterized by suppressed low-level moistening and excessive upper-level moisture retention. Our results highlight specific deficiencies in the model representation of convective vertical velocity, cloud microphysical processes, and convective precipitation organization within RRM-SCREAM. Addressing these biases is essential for improving the predictions of convective clouds and precipitation in the global high-resolution atmospheric models.

Su, Tianning [Lawrence Livermore National Laborato