Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Helium cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Sensitive method for characterizing liquid helium cooled preamplifier feedback resistors

It is pointed out that the simple and traditional method of measuring resistance using an electrometer is ineffective since it is limited to a narrow and nonrepresentative range of terminal voltages. The present investigation is concerned with a resistor measurement technique which was developed to select and calibrate the Transimpedance Mode Amplifier (TIA) load resistors on the Infrared Astronomical Satellite (IRAS) for the wide variety of time and voltage varying signals which will be processed during the flight. The developed method has great versatility and power, and makes it possible to measure the varied and complex responses of nonideal feedback resistors to IR photo-detector currents. When employed with a stable input coupling capacitor, and a narrow band RMS voltmeter, the five input waveforms thouroughly test and calibrate all the features of interest in a load resistor and its associated TIA circuitry.

Smeins, L. G.↗

Liquid helium cooled Fabry-Perot spectrometers

An account is given of two successful efforts to construct cryogenic Fabry-Perot interferometers that are sufficiently compact and stable for such harsh conditions as those of balloon or space observations, as well as ground-based ones. Attention is given to the design features and performance of a Fabry-Perot interferometer incorporating an electromagnet actuator, the ISAS interferometer, a Fabry-Perot spectrometer with superconducting actuators, and the University of Arizona interferometer.

Okuda, H.↗

Absolute photometric calibration of detectors to 0.3 mmag using amplitude-stabilized lasers and a helium-cooled absolute radiometer

Laser sources whose intensity is determined with a cryogenic electrical substitution radiometer are described. Detectors are then calibrated against this known flux, with an overall error of 0.028 percent (0.3 mmag). Ongoing research has produced laser intensity stabilizers with flicker and drift of less than 0.01 percent. Recently, the useful wavelength limit of these stabilizers have been extended to 1.65 microns by using a new modular technology and InGaAs detector systems. Data from Si photodiode calibration using the method of Zalewski and Geist are compared against an absolute cavity radiometer calibration as an internal check on the calibration system.

Miller, Peter J.↗

Calibration of a helium-cooled infrared spatial radiometer and grating spectrometer

Methods used by the Space Dynamics Laboratory of Utah State University (SDL/USU) to calibrate infrared sensors are described, using the Infrared Background Signature Survey (IBSS) spatial radiometer and grating spectrometer as examples. A calibration equation and a radiometric model are given for each sensor to describe their responsivity in terms of individual radiometric parameters. The calibration equation terms include dark offset, linearity, absolute responsivity, and measurement uncertainty, and the radiometric model domains include spatial, spectral, and temporal domains. A portable calibration facility, designed and fabricated by SDL/USU, provided collimated, extended, diffuse scatter, and Jones sources in a single cryogenic dewar. This multi-function calibrator allowed calibration personnel to complete a full calibration of the IBSS infrared radiometer and spectrometer in two 15-day periods. A calibration data system was developed to control and monitor the calibration facility, and to record and analyze sensor data.

Jacobsen, Larry↗

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.↗

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope Observatory, the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.↗

Cryogenic masers

Various factors affecting the frequency stability of hydrogen masers are described and related to maser design parameters. The long-term frequency stability of a hydrogen maser is limited by the mechanical stability of the cavity, and the magnitudes of the wall relaxation, spin exchange, and recombination rates which affect the Q of the line. Magnetic resonance studies of hydrogen atoms at temperatures below 1 K and in containers coated with liquid helium films demonstrated that cryogenic masers may allow substantial improvements in all of these parameters. In particular the thermal expansion coefficients of most materials are negligible at 1 K. Spin exchange broadening is three orders of magnitude smaller at 1 K than at room temperature, and the recombination and wall relaxation rates are negligible at 0.52 K where the frequency shift due to the 4 He-coated walls of the container has a broad minimum as a function of temperature. Other advantages of the helium-cooled maser result from the high purity, homogeneity, and resilence of helium-film-coated walls and the natural compatibility of the apparatus with helium-cooled amplifiers.

Berlinsky, A. J.↗

A helium-3 cooled bolometer system for one millimeter continuum observations

A new, 1-mm-continuum, bolometer detector system has been constructed employing internal adsorption pumping of He-3 to reach an operating temperature close to 0.4 K. The system spectral bandwidth is 800 to 1200 microns. Although the system was originally designed to be used on the 5-m Hale telescope, it has also been successfully used on the 4-m Anglo-Australian telescope and on the 10-m dish at Owens Valley, California. At the 5-m Hale telescope, the system has a full width-half maximum (FWHM) beam size of 55 sec and an instantaneous noise-equivalent flux density of 6 Jy/square root of (Hz)/ in good weather.

Roellig, T. P. L.↗

Infrared spectroscopy of the lower stratosphere with a balloon-borne cryogenic Fourier spectrometer

The IR limb emission of the lower stratosphere has been measured using a balloon-borne liquid nitrogen-cooled Michelson interferometer with liquid helium-cooled Si:Ga detectors. Portions of the thermal emission spectrum have been recorded between 650 and 2000/cm with an unapodized spectral resolution of 0.03/cm. This is the highest spectral resolution limb emission thus far obtained. A preliminary description is given of these data along with a discussion of the significant features. Species identified to date include CO2, O3, CFCl3, CF2Cl2, H2O, CH4, HNO3, N2O, NO2, and ClONO2. A tentative identification is made for NO, representing the first direct spectroscopic detection of NO in emission.

Kunde, Virgil G.↗

Cryogenic Fourier spectrometer for measuring trace species in the lower stratosphere

A cryogenic Fourier transform spectrometer has been built to measure thermal emission of the earth's limb from a balloon-borne platform. Liquid nitrogen cooling of the spectrometer and liquid helium cooling of the detectors has provided sufficient sensitivity to detect, at 5-15 microns, fifteen molecular species relevant to stratospheric ozone chemistry. The spectral resolution achieved, 0.022/cm, is the best yet attained for emission mode data at these wavelengths. The philosophy behind the design of the optical and electronic systems is presented, followed by an analysis of the performance achieved during balloon flight.

Brasunas, John C.↗

Preventing Raman Lasing in High-Q WGM Resonators

A generic design has been conceived to suppress the Raman effect in whispering- gallery-mode (WGM) optical resonators that have high values of the resonance quality factor (Q). Although it is possible to exploit the Raman effect (even striving to maximize the Raman gain to obtain Raman lasing), the present innovation is intended to satisfy a need that arises in applications in which the Raman effect inhibits the realization of the full potential of WGM resonators as frequency-selection components. Heretofore, in such applications, it has been necessary to operate high-Q WGM resonators at unattractively low power levels to prevent Raman lasing. (The Raman-lasing thresholds of WGM optical resonators are very low and are approximately proportional to Q(sup -2)). Heretofore, two ways of preventing Raman lasting at high power levels have been known, but both entail significant disadvantages: A resonator can be designed so that the optical field is spread over a relatively large mode volume to bring the power density below the threshold. For any given combination of Q and power level, there is certain mode volume wherein Raman lasing does not start. Unfortunately, a resonator that has a large mode volume also has a high spectral density, which is undesirable in a typical photonic application. A resonator can be cooled to the temperature of liquid helium, where the Raman spectrum is narrower and, therefore, the Raman gain is lower. However, liquid-helium cooling is inconvenient. The present design overcomes these disadvantages, making it possible to operate a low-spectral-density (even a single-mode) WGM resonator at a relatively high power level at room temperature, without risk of Raman lasing.

Savchenkov, Anatoliy↗

Review of the absorption spectra of solid O2 and N2 as they relate to contamination of a cooled infrared telescope

During contamination studies for the liquid helium cooled shuttle infrared telescope facility, a literature search was conducted to determine the absorption spectra of the solid state of homonuclear molecules of O2 and N2, and ascertain what laboratory measurements of the solid have been made in the infrared. With the inclusion of one unpublished spectrum, the absorption spectrum of the solid oxygen molecule has been thoroughly studied from visible to millimeter wavelengths. Only two lines appear in the solid that do not also appear in the gas or liquid. A similar result is implied for the solid nitrogen molecule because it also is homonuclear. The observed infrared absorption lines result from lattice modes of the alpha phase of the solid, and disappear at the warmer temperatures of the beta, gamma, and liquid phases. They are not observed from polycrystalline forms of O2, while strong scattering is. Scattering, rather than absorption, is considered to be the principal natural contamination problem for cooled infrared telescopes in low earth orbit.

Smith, S. M.↗

Cooled grating infrared spectrometer for astronomical observations

A liquid helium-cooled infrared spectrometer for the 16 to 50 micron range is described. The instrument has six detectors, three each of Si:Sb and Ge:Ga and two diffraction gratings mounted back-to-back. Cold preoptics are used to match the spectrometer to the telescope. In its nominal configuration the system resolution is 0.03 micron from 16 to 30 microns and 0.07 micron from 28 to 50 microns. A cooled filter wheel is used to change order sorting filters. The gratings are driven by a steel band and gear train operating at 4 K. The detector outputs are amplified by a TIA, employing a matched pair of JFETs operating at 70 K inside the dewar. The external warm electronics include a gain stage for the TIA and dc-coupled gating circuit to remove charged-particle (cosmic-ray secondary)-induced noise spikes. The gating circuit reduces the overall system noise by a factor of two when the spectrometer is used on NASA's Kuiper Airborne Observatory. Sample spectra are presented and the deglitcher performance is illustrated.

Houck, J. R.↗

The Astromag superconducting magnet facility configured for a free-flying satellite

The magnet parameters of a free-flying version of Astromag and the parameters of the space cryogenic system for the magnet are presented. Consideration is given to the free-flyer version of the Astromag magnet. The diameter of the magnet, its cryostat, the satellite and the two instruments is limited by the 4.27-m shroud diameter of the Atlas IIa. The magnet coil must use a stable reliable superconductor which can carry the full magnet current at 4.2 K at a peak induction in the coil of 7.5 T. The magnet must operate in the persistent mode. The changes in the overall design and operating requirements for the free-flying-design Astromag suggest that the coils, the cryogenic system, and the charging system can be simplified without a loss of required magnet function. Attention is given to switches, trim coils, and plumbing in the low field region between the coils; the magnet charging system and the quench protection system; and cooled helium supply to the magnet gas-cooled electrical leads.

Green, M. A.↗

The MIPAS balloon borne trace constitutent experiment

A novel cryogenic Fourier transform spectrometer (FTS) has been developed for limb emission measurements in the mid IR-region from balloon-borne platforms. The FTS is a rapid scanning interferometer using a modified Michelson arrangement which allows a spectral resolution of 0.04 cm(exp -1) to be achieved. Solid carbon-dioxide cooling of the spectrometer and liquid-helium cooling of the detectors provide adequate sensitivity. The line of sight can be stabilized in terms of azimuth and elevation. A three-mirror off-axis telescope provides good vertical resolution and straylight rejection. Calibration is performed by high elevation and internal blackbody measurements. Four balloon flights were performed, two of them during spring turn-around 1989 and 1990 over mid-latitudes (Aire sur L'Adour, France, 44 deg N) and two near the northern polar circle in winter 1992 (Esrange, Sweden, 68 deg N). Limb emission spectra were collected from 32 km to 39 km floating altitudes covering tangent heights between the lower troposphere and the floating altitude. The trace gases CO2, H2O, O3, CH4, N2O, HNO3, N2O5, ClONO2, CF2Cl2, CFCl3, CHF2Cl, CCl4, and C2H6 have been identified in the measured spectra. The 1989 data have been analyzed to retrieve profiles of O3, HNO3, CFCl3 and CF2Cl2. The flights over Kiruna have provided the first ever reported profile measurements of the key reservoir species ClONO2 and N2O5 inside the polar vortex.

Oelhaf, H.↗