Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hartmann”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A laboratory verification sensor

The use of a variant of the Hartmann test is described to sense the coalignment of the 36 primary mirror segments of the Keck 10-meter Telescope. The Shack-Hartmann alignment camera is a surface-tilt-error-sensing device, operable with high sensitivity over a wide range of tilt errors. An interferometer, on the other hand, is a surface-height-error-sensing device. In general, if the surface height error exceeds a few wavelengths of the incident illumination, an interferogram is difficult to interpret and loses utility. The Shack-Hartmann aligment camera is, therefore, likely to be attractive as a development tool for segmented mirror telescopes, particularly at early stages of development in which the surface quality of developmental segments may be too poor to justify interferometric testing. The constraints are examined which would define the first-order properties of a Shack-Hartmann alignment camera and the precision and range of measurement one could expect to achieve with it are investigated. Fundamental constraints do arise, however, from consideration of geometrical imaging, diffraction, and the density of sampling of images at the detector array. Geometrical imagining determines the linear size of the image, and depends on the primary mirror diameter and the f-number of a lenslet. Diffraction is another constraint; it depends on the lenslet aperture. Finally, the sampling density at the detector array is important since the number of pixels in the image determines how accurately the centroid of the image can be measured. When these factors are considered under realistic assumptions it is apparent that the first order design of a Shack-Hartmann alignment camera is completely determined by the first-order constraints considered, and that in the case of a 20-meter telescope with seeing-limited imaging, such a camera, used with a suitable detector array, will achieve useful precision.

Vaughan, Arthur H.↗

Refining Martian Ages and Understanding Geological Processes From Cratering Statistics

Senior Scientist William K. Hartman presents his final report on Mars Data Analysis Program grant number NAG5-12217: The third year of the three-year program was recently completed in mid-2005. The program has been extremely productive in research and data analysis regarding Mars, especially using Mars Global Surveyor and Mars Odyssey imagery. In the 2005 alone, three papers have already been published, to which this work contributed.1) Hartmann, W. K. 200.5. Martian cratering 8. Isochron refinement and the history of Martian geologic activity Icarus 174, 294-320. This paper is a summary of my entire program of establishing Martian chronology through counts of Martian impact craters. 2) Arfstrom, John, and W. K. Hartmann 2005. Martian flow features, moraine-like rieges, and gullies: Terrestrial analogs and interrelationships. Icarus 174,32 1-335. This paper makes pioneering connections between Martian glacier-like features and terrestrial glacial features. 3) Hartmann, W.K., D. Winterhalter, and J. Geiss. 2005 Chronology and Physical Evolution of Planet Mars. In The Solar System and Beyond: Ten Years of ISSI (Bern: International Space Science Institute). This is a summary of work conducted at the International Space Science Institute with an international team, emphasizing our publication of a conference volume about Mars, edited by Hartmann and published in 2001.

Hartmann, William K.↗

Recent Enhancements of the Phased Array Mirror Extendible Large Aperture (PAMELA) Telescope Testbed at MSFC

Recent incremental upgrades to the Phased Array Mirror Extendible Large Aperture (PAMELA) telescope testbed have enabled the demonstration of phasing (with a monochromatic source) of clusters of primary mirror segments down to the diffraction limit. PAMELA upgrades include an improved Shack-Hartmann wavefront sensor, passive viscoelastic damping treatments for the voice-coil actuators, mechanical improvement of mirror surface figures, and optical bench baffling. This report summarizes the recent PAMELA upgrades, discusses the lessons learned, and presents a status of this unique testbed for wavefront sensing and control. The Marshall Space Flight Center acquired the Phased Array Mirror Extendible Large Aperture (PAMELA) telescope in 1993 after Kaman Aerospace was unable to complete integration and testing under the limited SDIO and DARPA funding. The PAMELA is a 36-segment, half-meter aperture, adaptive telescope which utilizes a Shack-Hartmann wavefront sensor, inductive coil edge sensors, voice coil actuators, imaging CCD cameras and interferometry for figure alignment, wavefront sensing and control. MSFC originally obtained the PAMELA to supplement its research in the interactions of control systems with flexible structures. In August 1994, complete tip, tilt and piston control was successfully demonstrated using the Shack-Hartmann wavefront sensor and the inductive edge sensors.

Rakoczy, John↗

The Effect of a Rotating Magnetic Field on Rayleigh-Benard Convection

A destabilizing vertical temperature gradient and a rotating magnetic field have been applied to a cylindrical column of liquid gallium. The convective flows which arise as a function of these driving parameters are identified. For small magnetic field strengths, a region of stationary flow is observed. This region is bounded by critical values of the Rayleigh and Hartmann numbers. As the rotating magnetic field is increased, the critical Rayleigh number can increase by more than a factor of 10. The rotating magnetic field itself induces an instability at a critical value of the Hartmann number independent of the Rayleigh number. The nature of the bifurcations (whether subcritical or supercritical) and the convective flows occurring at the critical Rayleigh numbers are dependent upon the Hartmann number. In the stationary flow region, the rotating magnetic field can induce fluid motion with velocities on the order of cm/s. Thus, a rotating magnetic field can be used to achieve the benefits of forced convection during crystal growth processes without triggering deleterious instabilities.

Volz, Martin P.↗

The Effect of a Rotating Magnetic Field on Flow Stability During Crystal Growth

The effect of a rotating magnetic field on the stability of flow in crystal growth configurations has been experimentally modeled using liquid gallium contained in a finite cylinder and heated from below. Several distinct flow regions were determined as a function of the Rayleigh and Hartmann numbers. At low values of the Rayleigh and Hartmann numbers, a region of stationary flow exists. As the rotating magnetic field is increased, the critical Rayleigh number bounding the stationary flow region can increase by a factor of 10. However, the rotating magnetic field itself induces an instability at a critical value of the Hartmann number independent of the Rayleigh number. In the stationary flow region, the rotating magnetic field can induce fluid motion with velocities several orders of magnitude larger than typical semiconductor crystal growth velocities. Thus, a rotating magnetic field can be used to achieve the benefits of forced convection without triggering deleterious instabilities.

Volz, Martin P.↗

Recent Enhancements of the Phased Array Mirror Extendible Large Aperture (PAMELA) Telescope Testbed at MSFC

Recent incremental upgrades to the Phased Array Mirror Extendible Large Aperture (PAMELA) telescope testbed have enabled the demonstration of phasing (with a monochromatic source) of clusters of primary mirror segments down to the diffraction limit. PAMELA upgrades include in improved Shack-Hartmann wavefront sensor, passive viscoelastic damping treatments for the voice-coil actuators, mechanical improvement of mirror surface figures, and optical bench baffling. This report summarizes the recent PAMELA upgrades, discusses the lessons learned, and presents a status of this unique testbed for wavefront sensing and control. The Marshall Space Flight Center acquired the Phased Array Mirror Extendible Large Aperture (PAMELA) telescope in 1993 after Kaman Aerospace was unable to complete integration and testing under the limited SDIO and DARPA funding. The PAMELA is a 36-segment, half-meter aperture, adaptive telescope which utilizes a Shack-Hartmann wavefront sensor, inductive coil edge sensors, voice coil actuators, imaging CCD cameras and interferometry for figure alignment, wavefront sensing and control. MSFC originally obtained the PAMELA to supplement its research in the interactions of control systems with flexible structures. In August 1994, complete tip, tilt and piston control was successfully demonstrated using the Shack-Hartmann wavefront sensor and the inductive edge sensors.

Rakoczy, John↗

Pulsed Ejector Thrust Amplification Tested and Modeled

There is currently much interest in pulsed detonation engines for aeronautical propulsion. This, in turn, has sparked renewed interest in pulsed ejectors to increase the thrust of such engines, since previous, though limited, research had indicated that pulsed ejectors could double the thrust in a short device. An experiment has been run at the NASA Glenn Research Center, using a shrouded Hartmann-Sprenger tube as a source of pulsed flow, to measure the thrust augmentation of a statistically designed set of ejectors. A Hartmann- Sprenger tube directs the flow from a supersonic nozzle (Mach 2 in the present experiment) into a closed tube. Under appropriate conditions, an oscillation is set up in which the jet flow alternately fills the tube and then spills around flow emerging from the tube. The tube length determines the frequency of oscillation. By shrouding the tube, the flow was directed out of the shroud as an axial stream. The set of ejectors comprised three different ejector lengths, three ejector diameters, and three nose radii. The thrust of the jet alone, and then of the jet plus ejector, was measured using a thrust plate. The arrangement is shown in this photograph. Thrust augmentation is defined as the thrust of the jet with an ejector divided by the thrust of the jet alone. The experiments exhibited an optimum ejector diameter and length for maximizing the thrust augmentation, but little dependence on nose radius. Different frequencies were produced by changing the length of the Hartmann-Sprenger tube, and the experiment was run at a total of four frequencies. Additional measurements showed that the major feature of the pulsed jet was a starting vortex ring. The size of the vortex ring depended on the frequency, as did the optimum ejector diameter.

Wilson, Jack↗

Mapping Galactic 60Fe Synthesis in Cen CIR Region

This included a 1 year no cost time extension. The grant was for research into the origin of radioactive 60Fe, whose detection was a mission goal for INTEGRAL and RHESSI. During the grant period, both missions ultimately discovered gamma-line emission from this long lived radioactivity at precisely the value that had been predicted years before by Timmes and Woosley (ApJ, 449,204 (1995)). Unfortunately, using "revised" stellar models and cross sections Rauscher et a1 (ApJ, 576, 323 (2002)), had meanwhile predicted a much larger value. During the grant period, Dieter Hartmann (PI on the complementary grant at Clemson) and Woosley corresponded on this discrepancy and Hartmann visited Santa Cruz (November 20 - 28,2004). All of the grant funds in NAG513659 paid for the expenses of that visit. Subsequently, partly motivated by conversations with Hartmann and Diehl, Woosley re-investigated the production of 60Fe and 26A1 in massive stars from 12 - 120 solar masses, with an eye towards determining the relevant, uncertain physics. The chief changes in Rauscher et a1 were "new" Hauser Feshbach cross sections for 59,60Fe(ng) and 26Al(np)26Mg. The latter has an experimental evaluation which was actually better represented in the study of Timmes and Woosley. The iron (ng) cross sections are from theory and the Timmes and Woosley values were just as reliable as those from Rauscher. Experiments need to be done to resolve who is right. In addition uncertainties in stellar winds, opacities and the IMF were explored. The bottom line is that the value predicted by Timmes and Woosley could well be the correct one, but the experimental error bar is larger than was realized. At least half of the uncertainty is nuclear cross sections that can, and should be measured in the laboratory.

Woosley, Stanford↗

A Broad-Band Phase-Contrast Wave-Front Sensor

A broadband phase-contrast wave-front sensor has been proposed as a real-time wave-front sensor in an adaptive-optics system. The proposed sensor would offer an alternative to the Shack-Hartmann wave-front sensors now used in high-order adaptive-optics systems of some astronomical telescopes. Broadband sensing gives higher sensitivity than does narrow-band sensing, and it appears that for a given bandwidth, the sensitivity of the proposed phase-contrast sensor could exceed that of a Shack-Hartmann sensor. Relative to a Shack-Hartmann sensor, the proposed sensor may be optically and mechanically simpler. As described below, an important element of the principle of operation of a phase-contrast wave-front sensor is the imposition of a 90deg phase shift between diffracted and undiffracted parts of the same light beam. In the proposed sensor, this phase shift would be obtained by utilizing the intrinsic 90 phase shift between the transmitted and reflected beams in an ideal (thin, symmetric) beam splitter. This phase shift can be characterized as achromatic or broadband because it is 90deg at every wavelength over a broad wavelength range.

Bloemhof, Eric↗

Wave-driven winds from cool stars. I - Some effects of magnetic field geometry

The wave-driven wind theory of Hartmann and MacGregor (1980) is extended to include effects due to non-radial divergence of the flow. Specifically, isothermal expansion within a flow tube whose cross-sectional area increases outward faster than the square of the radius near the stellar surface is considered. It is found that the qualitative conclusions of Hartmann and MacGregor concerning the physical properties of Alfven wave-driven winds are largely unaffected. In particular, mass fluxes of similar magnitude are obtained, and wave dissipation is still necessary to produce acceptably small terminal velocities. Increasingly divergent flow geometries generally lead to higher initial wind speeds and slightly lower terminal velocities. For some cases of extremely rapid flow tube divergence, steady supersonic wind solutions which extend to infinity with vanishing gas pressure cannot be obtained. In addition, departures from spherical symmetry can cause the relative Alfven wave amplitude delta-B/B to become approximately greater than 1 within several stellar radii of the base of the wind, suggesting that nonlinear processes may contribute to the wave dissipation required by the theory.

Hartmann, L.↗

Development of MHD flow in the entrance region of a channel.

A general method has been developed for determining the developing magnetohydrodynamic flow in the entrance region of a parallel-plate channel. Closed form solutions are obtained. Numerical results are presented for the development of velocity distribution, pressure drop, and magnetohydrodynamic entrance length at different Hartmann numbers. At large Hartmann numbers, the magnetic field effect becomes dominant and the magnetohydrodynamic entrance length becomes negligible. Also, the pressure drop is enhanced by the magnetic field. Comparison of results with direct numerical analysis shows excellent agreement.-

Wu, S. T.↗

Wavefront error sensing for LDR

Wavefront sensing is a significant aspect of the LDR control problem and requires attention at an early stage of the control system definition and design. A combination of a Hartmann test for wavefront slope measurement and an interference test for piston errors of the segments was examined and is presented as a point of departure for further discussion. The assumption is made that the wavefront sensor will be used for initial alignment and periodic alignment checks but that it will not be used during scientific observations. The Hartmann test and the interferometric test are briefly examined.

Tubbs, Eldred F.↗

Rayleigh Convection in a Rotating Magnetic Field

The onset of steady and time-dependent flows were measured in a cylinder of liquid gallium subjected to a vertical temperature gradient and a horizontal rotating magnetic field (RMF). By varying the applied vertical temperature gradients and the strength of the applied magnetic field, a stability diagram in Rayleigh number - Hartmann number parameter space was constructed. The application of a RMF increased the critical value of the Rayleigh number by up to a factor of 10. However, there was observed a critical value of the Hartmann number where instability set in, regardless of the value of the Rayleigh number. Significant hysteresis in the value of the critical Rayleigh number was observed depending on whether the applied thermal gradient was increasing or decreasing.

Volz, M. P.↗

Phase-Shifting Liquid Crystal Point-Diffraction Interferometry

Microgravity fluid physics experiments frequently measure concentration and temperature. Interferometers such as the Twyman Green illustrated have performed full-field measurement of these quantities. As with most such devices, this interferometer uses a reference path that is not common with the path through the test section. Recombination of the test and reference wavefronts produces interference fringes. Unfortunately, in order to obtain stable fringes, the alignment of both the test and reference paths must be maintained to within a fraction of the wavelength of the light being used for the measurement. Otherwise, the fringes will shift and may disappear. Because these interferometers are extremely sensitive to bumping, jarring and transmitted vibration, they are typically mounted on optical isolation tables. Schlieren deflectometers or the more recent Shack-Hartmann wavefront sensors also measure concentration and temperature in laboratory fluid flows. Ray optics describe the operation of both devices. In a schlieren system, an expanded, collimated beam passes through a test section where refractive index gradients deflect rays. A lens focuses the beam to a filter placed in the rear focal plane of the decollimating lens. In a quantitative color schlieren system, gradients in the index of refraction appear as colors in the field of view due to the action of the color filter. Since sensitivity is a function of the focal length of the decollimating lens, these systems are rather long and filter fabrication and calibration is rather difficult. A Shack-Hartmann wavefront sensor is an array of small lenslets. Typical diameters are on the order of a few hundred microns. Since these lenslets divide the test section into resolution elements, the spatial resolution can be no smaller than an individual lenslet. Such a device was recently used to perform high-speed tomography of heated air exiting a 1.27 cm diameter nozzle. While these wavefront sensors are very compact, the limited spatial resolution and the methods required for data reduction suggest that a more useful instrument needs to be developed. The category of interferometers known as common path interferometers can eliminate much of the vibration sensitivity associated with traditional interferometry as described above. In these devices, division of the amplitude of the wavefront following the test section produces the reference beam. Examples of these instruments include shearing and point diffraction interferometers. In the latter case, shown schematically, a lens focuses light passing through the test section onto a small diffracting object. Such objects are typically either a circle of material on a high quality glass plate or a small sphere in a glass cell. The size of the focused spot is several times larger than the object so that the light not intercepted by the diffracting object forms the test beam while the diffracted light generates a spherical reference beam. While this configuration is mechanically stable, phase shifting one beam with respect to the other is difficult due to the common path. Phase shifting enables extremely accurate measurements of the phase of the interferogram using only gray scale intensity measurements and is the de facto standard of industry. Mercer and Creath 2 demonstrated phase shifting in a point diffraction interferometer using a spherical spacer in a liquid crystal cell as the diffracting object. By changing the voltage across the cell, they were able to shift the phase of the undiffracted beam relative to the reference beam generated by diffraction from the sphere. While they applied this technology to fluid measurements, the device shifted phase so slowly that it was not useful for studying transient phenomena. We have identified several technical problems that precluded operation of the device at video frame rates and intend to solve them to produce a phase-shifting liquid crystal point-diffraction interferometer operating at video frame rates. The first task is to produce high contrast fringes. Since the diffracted beam is much weaker than the transmitted beam, interferograms have poor contrast unless a dye is added to the liquid crystal to reduce the intensity of the undiffracted light. Dyes previously used were not rigorously characterized and suffered from hysteresis in both the initial alignment state of the device and the electro-optic switching characteristics. Hence, our initial effort will identify and characterize dyes that do not suffer from these difficulties and are readily soluble in the liquid crystal host. Since the ultimate goal of this research is to produce interferometers capable of phase shifting at video frame rates, we will quantify the difference in switching times between ferroelectric and nematic liquid crystals. While we have more experience with nematic crystals, they typically switch more slowly than ferroelectric cells. As part of that effort, we will investigate the difference in the modulation of the interferograms as a function of the type of liquid crystal in the cell. Because the temporal switching response of a liquid crystal cell is directly related its thickness, we intend to explore techniques required to produce cells that are as thin as possible. However, the cells must still produce a total phase shift of two pi radians.

Griffin, DeVon W.↗

Response to "No Evidence for Iris"

Hartmann and Michelsen claimed that there was no evidence for the negative relation between the high-level clouds and the sea surface temperature as suggested by Lindzen et al. The assertion made by Hartmann and Michelsen that there is a need for clouds thousands of kilometers away from the equator to be connected to convection at the equator does not seem to have any validity. Nor does their suggestion that the causes of the observational relations shown in Lindzen et al. do not involve detrainment.

Chou, Ming-Dah↗

Comments on "Tropical Convection and the Energy Balance at the Top of the Atmosphere"

Analyses of the Earth Radiation Budget Experiment (ERBE) data show that the effects of clouds on the solar and thermal infrared radiation in the tropical deep convective regions have a similar magnitude but opposite signs. This small difference in the effects of clouds on radiation led Hartmann et al. (2001) to conclude that the contrast in the net radiation at the top of the atmosphere between the convective and non-convective regions must also be small. However, we have found that the ERBE data do not generally show a small contrast in the radiation between the convective and non-convective regions, and the model used by Hartmann et al., therefore, seems unlikely to represent the real physical processes involving convection, radiation, and climate in an appropriate way.

Chou, Ming-Dah↗

Grazing Incidence Wavefront Sensing and Verification of X-Ray Optics Performance

Evaluation of interferometrically measured mirror metrology data and characterization of a telescope wavefront can be powerful tools in understanding of image characteristics of an x-ray optical system. In the development of soft x-ray telescope for the International X-Ray Observatory (IXO), we have developed new approaches to support the telescope development process. Interferometrically measuring the optical components over all relevant spatial frequencies can be used to evaluate and predict the performance of an x-ray telescope. Typically, the mirrors are measured using a mount that minimizes the mount and gravity induced errors. In the assembly and mounting process the shape of the mirror segments can dramatically change. We have developed wavefront sensing techniques suitable for the x-ray optical components to aid us in the characterization and evaluation of these changes. Hartmann sensing of a telescope and its components is a simple method that can be used to evaluate low order mirror surface errors and alignment errors. Phase retrieval techniques can also be used to assess and estimate the low order axial errors of the primary and secondary mirror segments. In this paper we describe the mathematical foundation of our Hartmann and phase retrieval sensing techniques. We show how these techniques can be used in the evaluation and performance prediction process of x-ray telescopes.

Saha, Timo T.↗

Phase Contrast Wavefront Sensing for Adaptive Optics

Most ground-based adaptive optics systems use one of a small number of wavefront sensor technologies, notably (for relatively high-order systems) the Shack-Hartmann sensor, which provides local measurements of the phase slope (first-derivative) at a number of regularly-spaced points across the telescope pupil. The curvature sensor, with response proportional to the second derivative of the phase, is also sometimes used, but has undesirable noise propagation properties during wavefront reconstruction as the number of actuators becomes large. It is interesting to consider the use for astronomical adaptive optics of the "phase contrast" technique, originally developed for microscopy by Zemike to allow convenient viewing of phase objects. In this technique, the wavefront sensor provides a direct measurement of the local value of phase in each sub-aperture of the pupil. This approach has some obvious disadvantages compared to Shack-Hartmann wavefront sensing, but has some less obvious but substantial advantages as well. Here we evaluate the relative merits in a practical ground-based adaptive optics system.

adaptive optics↗