At least 37 records · Page 2

An Application of Molecular Recognition for the Efficient Removal of Cesium from Hanford Nuclear Waste by Modular Solvent Extraction

In this work, experimental results leading to flowsheet design are presented showing how a calixarene-crown ether based solvent-extraction process can meet the challenge of cesium removal from nuclear tank wastes stored at the US Department of Energy Hanford site. Cleanup of legacy Cold War nuclear waste stored in underground tanks represents one of the greatest environmental challenges facing the US Department of Energy in terms of risk, cost, and effectiveness of applicable science and technology. Planning for the cleanup at the Hanford Site calls for the removal of the radioactive fission product 137Cs from its alkaline salt waste, including the use of modular processes that can be deployed near the tank farms. To meet the resulting need for extremely high selectivity, the Next-Generation Caustic-Side Solvent Extraction (NG-CSSX) process employing a calix[4]arene-crown ether in modified kerosene has been adapted to remove sub-millimolar cesium in competition with molar sodium and potassium in a high-nitrate alkaline matrix. Potassium loading in the solvent was determined in extraction, scrubbing, and stripping, leading to an empirical model closely approximating cesium distribution ratios for a variety of Hanford waste types. Process chemistry has been developed based on this molecular-recognition approach, focusing on the competitive effect of potassium loading and the mitigating process modifications needed, including extending the scrub section. The result is a modular flowsheet design that can achieve cesium decontamination factors well in excess of 15,000 even for the worst-case Hanford waste.

Williams, Neil [ORNL] (ORCID:000000023159226X)

Prototype Hanford Barrier Performance Monitoring Report: Fiscal Year 2024

This report provides an annual update on performance monitoring of the Prototype Hanford Barrier (PHB) at the Hanford Site. The PHB is part of a long-term study that serves as the scientific basis for many of the evapotranspiration-capillary barrier designs currently used globally and for future engineered barrier designs planned for remedial actions over waste and demolition sites at the Hanford Site. The PHB allows us to identify potential future issues and develop better monitoring techniques before these engineered barriers are constructed. Surface barriers like the PHB are essential for preventing water infiltration and curbing the spread of contaminants to groundwater. Effective monitoring of soil moisture levels above and below these barriers is crucial given that performance metrics could span up to 1,000 years. From July 2023 to June 2024, the water flux (as measured by tipping buckets) through the 2-m-thick silt loam layer of the PHB – a fine silty material that stores water under high capillary tension – remained well below the 0.5-mm-per-year performance threshold, demonstrating its effectiveness in preventing water penetration. In 2024, degraded tipping bucket gauges were replaced to ensure the accuracy of future data. Additionally, neutron probes revealed that the wetting front from the rainy season only penetrated to a maximum depth of 1.2 m into the silt loam. This further demonstrated the barrier's efficiency, as the wetting front did not fully penetrate the 2-m-thick capillary barrier. The western gravel slope of the PHB, composed of Hanford Site pit gravel of varying sizes, demonstrated low flux rates. In contrast, the eastern riprap slope exhibited higher flux rates. Zhang (2017) found that the riprap side slope of the PHB had the highest drainage rates in January and the lowest in late summer or early fall, indicating significant summer evaporation. Drainage rates increased significantly under enhanced precipitation conditions, far exceeding the design criterion, which could lead to water infiltration into the waste zone. The study introduced the “edge effect,” where elevated drainage rates from the riprap may migrate laterally beneath the barrier, compromising its ability to isolate waste, and recommended expanding the barrier and conducting further research to mitigate this issue. This report provides a review on surface barrier edge effects and their potential impact to subsurface contaminant migration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Vitrification of Hanford Tank 241-AW-105 Waste and Equivalent Simulant

Hanford Site nuclear waste is to be vitrified at the Waste Treatment and Immobilization Plant (WTP), which is a part of the safe and efficient retrieval, treatment, and disposal mission of the U.S. Department of Energy - Hanford Field Office. A portion of Hanford tank 241-AW-105 (referred to herein as AW-105) waste was retrieved by Hanford Tank Waste Operations and Closure (H2C) and transferred to Pacific Northwest National Laboratory (PNNL). Compared to previously received and vitrified wastes (AP-107, AP-101, AN-107 and AP-105), the concentration of potassium in AW-105 was greater by an order of magnitude.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

A Prototype Software to Demonstrate a Data Catalog for Hanford Environmental Datasets

Ensuring that data on long-term environmental remediation at the Hanford Site is high-quality, traceable, and easily accessible is an ongoing challenge, complicated by decades of data collection, multiple contractors maintaining data sources, and the wide range of data types. A centralized data catalog, known as the Hanford Environmental Information and Data Index (HEIDI), has been under development as part of the Hanford Environmental Data Management (HEDM) program to address these challenges. HEIDI fulfills a critical need to bring together a wide range of data types and sizes from multiple authoritative data sources, while documenting the data pedigree and quality information (i.e., traceable to the data source/originator). This document describes additional development and maturation of the HEIDI prototype. Key accomplishments included deploying the catalog software, Esri Geoportal Server, on a server accessible to Hanford Local Area Network users, conducting cybersecurity evaluations, investigating integrated authentication solutions, and conducting functional testing of the catalog prototype. The server-based deployment enabled targeted feedback, leading to enhancements including improved accessibility features and an expanded metadata schema. Specifications for the server-based deployment of the prototype catalog and the HEIDI metadata schema are provided in this document to support subsequent HEIDI deployment by the U.S. Department of Energy Richland Operations Office.

54 ENVIRONMENTAL SCIENCES

Summary of Developing a Hanford Grout Modeling Framework Initial Workshop

The “Development of the Hanford Grout Modeling Framework” project as part of the Network of National Laboratories for Environmental Management and Stewardship (NNLEMS) funding program is underway. An initial project team workshop was held in Richland, WA on June 4 and 5, 2024 with participants from PNNL, SRNL, SNL, WRPS and CRESP (VU and UCF). The workshop covered an overview of the current state of the art in grout modeling tools provided by the team. Based on a focus on liquid waste immobilization grout and encapsulation grout for solid wastes and tank closure grout at Hanford, the team identified preliminary conceptual models for these three applications which will be used to form the basis of the Hanford Grout Modeling Framework. The key processes that can drive mechanisms impacting the grout performance were identified for each test case. The programmatic plan was also identified with five core Themes being selected that will form the focus of the project. Within each theme, individual tasks for Year 1 were planned in support of the development of an updated Hanford Grout Modeling Framework. This report presents a summary of the information presented during the workshop.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Annual Summary Report (FY 2025) Composite Analysis for Low-Level Waste Disposal in the Central Plateau of the Hanford Site

In accordance with DOE M 435.1-1, Radioactive Waste Management Manual, requirements, the U.S. Department of Energy (DOE) Hanford Field Office (HFO) prepared this Annual Summary Report (ASR) for fiscal year (FY) 2025 for the Hanford Site Composite Analysis (CA) reported in DOE/RL-2019-52, Composite Analysis for Low-Level Waste Disposal in the Hanford Site Central Plateau (FY 2020) (hereinafter referred to as the Hanford Site Composite Analysis). The preparation of this ASR follows the technical specifications provided in DOE-STD-5002-2017, Disposal Authorization Statement and Tank Closure Documentation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Cathodic Protection Modeling for Hanford Underground Double-Shell Tank Farms

Hanford stores millions of gallons of radioactive and chemically hazardous waste from the production of weapon materials in tank farms consisting of underground carbon-steel storage tanks surrounded by reinforced concrete. Six of these Hanford tank farms use double-shell storage tanks (DSTs). The DST farms were constructed from 1968 to 1986 with a planned 40–50 year design life, so some are already operating beyond their initial life expectancy. Ultrasonic testing (UT) has indicated significant thinning on the bottom of the secondary (outer) liner of these tanks, believed to arise from groundwater intrusion driving concrete side corrosion. There is no direct access to the steel/concrete interface between the tank and the concrete pad, making it difficult to apply a chemical-based mitigation strategy or to conduct repairs, but cathodic protection (CP) is a possible method to inhibit further concrete-side corrosion. Hanford already uses CP to protect below grade steel piping within the tank farms and connected to the tanks, but this system was not designed to protect the tank bottoms. CP design must account for the structures surrounding the DSTs, including the steel reinforcing bars (rebar) within the concrete pad and vault, various process lines, and the existing CP system. In this study, finite element analysis (FEA) modeling was carried out to simulate CP protection of 1) a single tank and CP anode to develop options for modeling the rebar and to compare to a simpler circuit model and 2) the entire Hanford AN tank farm as a representative example consisting of seven tanks, associated piping, and both existing and new CP anodes. Both circuit and FEA models predict that significant protective current could be delivered to the bottoms of the tanks with the addition of tank-protection anodes below the depth of the tanks. Simulations with only the existing pipe-protection anodes active confirmed that only a very small current to the tank bottoms is predicted under present conditions. Multiple simplified representations of the dome and wall rebar were tested to reduce the computational complexity of the tank-farm simulations, resulting in modeling the rebar as edge elements with a prescribed effective circumference that matches the real rebar surface area. The geometry of the rebar is also simplified into horizontal hoops around the tank walls and radial rebar over the dome with increased effective circumference to retain the target surface area. This simplification was found to greatly reduce the complexity and solution time of the models without large changes in current distributions, especially to the tank bottom. A range of values were tested for model parameters such as soil and concrete resistivities and polarization resistance to investigate their impact on the current and electric potential distributions. Depending on the parameters used, FEA simulations predict some risk of overprotection, particularly on the piping system; since overprotection can also lead to surface damage associated with hydrogen gas generation at the interface (e.g. hydrogen embrittlement or damage to coatings), this needs to be considered when refining the design of the new CP system. Comparison between the FEA models and the circuit model representation demonstrated that the circuit model could not match the predicted FEA current distribution, even when using the exact same surface areas. This discrepancy appeared to be at least partly attributable to the impact of the relative positions of the tank components and anodes to each other and to the ground surface. The FEA model accounts for the relative positions since it solves the governing equations in three dimensions, but the circuit model cannot account for the positioning. In particular, the circuit model underpredicts the current to the tank bottom and overpredicts the current to the dome compared to FEA for the baseline geometry. The FEA models omitted the electrically isolated rebar in the bottom concrete slab. However, a circuit based stray current model estimated that only 2.1% of the total current through the slab would stray into the rebar, corresponding to ~0.21 A for a target current density of 2 mA/ft2 to the tank bottom. The estimated corrosion driven by this amount of stray current is predicted to yield a lifetime of >400 years for the minimum rebar diameter, assuming an acceptable cross-section area loss of 10%.

d'Entremont, Anna [Savannah River National Laborat

Development of a Robust Reference Electrode in Aggressive Chemical and Radiation Environments in the Hanford Waste Tanks

The Hanford site stores more than 200 million liters of radioactive and chemically hazardous wastes from the production of weapons materials. The wastes are stored in 177 underground carbon-steel storage tanks, separated between 149 single shell tanks (SSTs) and 28 double shell tanks (DSTs). The DSTs provide critical retrieval and interim storage before the waste is vitrified in the Waste Treatment and Isolation Plant (WTP). The tanks will need to remain in-service far beyond the initial 40-year design life, and effective corrosion control practices must remain in force to extend the tanks’ lifespans. This effort includes direct measurements of corrosion rate (e.g., ultrasonic measurements and corrosion coupons) and electrochemical processes (e.g., linear polarization measurements and open circuit potential measurements). The Hanford site began monitoring the corrosion potential in select DSTs in 2008. Of the 45 reference electrodes that have been installed, 29 have failed and 6 others provided unreliable results. DOE-EM is supporting a 3-year program to develop a chemical and radiation resistant reference electrode for application in the Hanford tanks. The first year of the program focused on understanding the failure mechanism for the reference electrodes and identification of candidate construction materials that would mitigate degradation of the electrodes in the waste environment. During the second year of the program, the objectives were to: 1) test candidate materials under simulated waste conditions, 2) design components that will extend the service life of the electrode, 3) fabricate materials for prototype reference electrodes, and 4) assemble prototype reference electrodes for accelerated testing. The reference electrode is constructed of four principal parts: 1) junction, 2) casing, 3) inner chamber backfill materials, and 4) the sensing wire. Principally, improvements of the junction, casing, and inner chamber backfill materials are being pursued. The junction material at the interface between the waste and the inner chamber of the reference electrode was identified as a critical component in the failure of the reference electrodes. Nine candidate replacement junction materials were tested under simulated waste conditions to evaluate permeation rate. These materials included a variety of polymeric and ceramic materials, some of which were 3-D printed. Thus far, porous polyvinylidene fluoride materials have performed satisfactorily and are being considered for prototype development. The commercial electrode casing materials in general have performed well. Additionally, 3-D printing of chemically and mechanically stable materials is being investigated as a means for further improvement in fabrication consistency. SRNL has also investigated altering the reference electrode design to extend the service life. The new design of the interior of the reference electrode casing creates a longer, more tortuous path between the junction material and the electrode sensing wire. A finite element model was used to optimize the design without adversely impacting the circuit resistance of the electrode during the measurements, thus preserving the measurement accuracy while enhancing the service life. The inner chamber back fill materials are also critical to the performance of the reference electrode. Materials that are resistant to intruding tank waste and provide a conductive path to the sensing wire were investigated. Gel and powder materials that are interspersed with a conductive chloride bearing material were tested for their influence on diffusion and electrode resistance. All the investigated materials and components will be assembled, with collaboration from commercial vendors, to fabricate the initial prototypes. Accelerated testing of the prototypes will be initiated in Year 2 of the program and will be completed in Year 3. A recommendation on the materials of construction and the design of the new robust reference electrode will be presented to the Hanford tank farm facility.

Sykes, Kiana [Savannah River National Laboratory (

Volume Change from Solidification Correlation for Hanford Tank Waste.

The U.S. Department of Energy (DOE), Hanford Field Office’s primary mission is to safely and effectively treat Hanford’s tank waste and deliver environmental remediation. Mixed radioactive waste is stored in the underground tanks at the Hanford Site. It was recently estimated that retrieval of the waste in the 200 West Area underground tanks in the SY, S, SX, and U Tank Farms will result in about 41 million gallons of mixed low-level waste (MLLW) (RPP-RPT-65147, Rev. 1). The current plan is to retrieve at least 22 S, SX, and U Farm tanks and pretreat1 to produce pretreated tank waste (PTW) which will be further treated (including solidification /immobilization) for Resource Conservation and Recovery Act (RCRA) Land Disposal Restriction (LDR) organics and inorganics before being transferred to an offsite out-of-state facility for disposal (RPP-PLAN-66135, Rev. 2). In addition, solidified PTW from the 200 East Area may also be transferred to an offsite out-of-state facility for disposal to ensure availability of critical Double-Shell Tank space, meet retrieval obligations, and optimize 200 East Area operations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Determining Drying Conditions to Mitigate Hanford Transfer Line Corrosion

Hanford Site Background • Hanford site located in Washington State and established in 1943: 1460 km2 • Since 1988 the site has been engaged in a comprehensive environmental clean-up effort. Waste Tanks • 177 underground tanks with 56 million gallons of high-level radioactive waste and chemical waste in 150 Single Shell Tanks (SSTs) and 27 Double Shell Tanks (DSTs)

Shukla, Pavan K. [Savannah River National Laborato

Organic Evaporation, Oxidation, and Hydrolysis Testing in Support of Hanford Sample-and-Send

The Hanford site has approximately 54 to 56 million gallons of radioactive mixed waste stored in 156 unretrieved underground storage tanks. The Hanford Waste Treatment and Immobilization Plant (WTP) is being built to treat and immobilize the tank waste. The baseline method for immobilization of Low Activity Waste (LAW) through the WTP is vitrification, but additional immobilization capacity is needed to supplement the initial LAW melters. An alternative cementitious waste form is being investigated for that future immobilization method. However, one impediment to a cementitious waste form is the presence of Land Disposal Restricted (LDR) organic chemicals in tank waste, which are regulated on a concentration based standard in the final waste form. Hence, if the quantity of organics in LAW is high enough, they must be destroyed or removed to make a waste form compatible with disposal in a mixed low level waste landfill. This work evaluates potential avenues for treatment of LDR organics to eliminate the impediment and permit possible use of a cementitious waste form. Vacuum evaporation testing to remove LDR organics consisted of preparing a non-radioactive LAW simulant, spiking that simulant with organic chemicals, and evaporating the mixture via differential distillation. The apparatus was a laboratory-scale vacuum evaporator operated at 60 ±5 torr absolute (vacuum evaporation). The LAW simulant represented the liquid expected to be retrieved from the Hanford tank farms at approximately 4.0 M [Na+] total sodium ion concentration. The concentration of the organic chemicals added was significantly higher than typically found in the tank waste samples since the higher levels were necessary to assist in analytical measurement and tracking of the spiked species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Vitrification of Hanford Tank 241-AN-107 Waste and Equivalent Simulant

Hanford Site nuclear waste is to be vitrified at the Waste Treatment and Immobilization Plant (WTP), which is a part of the safe and efficient retrieval, treatment, and disposal mission of the U.S. Department of Energy Office of River Protection. Hanford tank 241-AN-107 (referred to herein as AN-107) is one of the initial Hanford radioactive tank wastes planned to be processed and vitrified. A portion of AN-107 waste was retrieved by Washington River Protection Solutions, LLC (WRPS) and transferred to Pacific Northwest National Laboratory (PNNL). Compared to previously received and vitrified wastes (AP-107, AP-105, and AP-105), the concentration of organics in AN-107 was greater by an order of magnitude, while the activity of radionuclides was multiple orders of magnitude greater.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

PFAS Removal by Ion Exchange Resins: Background and Knowledge Gaps with Respect to the Hanford Site

Per- and polyfluoroalkyl substances (PFAS) have been a rising concern for the past two decades, with the United States Department of Defense and Environmental Protection Agency investing millions of dollars in research into remediation and clean-up technologies. Due to the environmental persistence, toxicity, biological uptake, and ongoing changes in both federal and state regulatory space, understanding the fate and transport of PFAS compounds has been of growing concern to the US Department of Energy (DOE). The DOE’s Hanford Site is investigating historical use of PFAS and will be doing site characterization for PFAS. Thus, PFAS have not yet been identified as a contaminant concern in regulatory documents. Based on historical records that mention the discharge of aqueous film-forming foam containing PFAS and having on-site fire stations (a risk factor for PFAS contamination), it seems likely that environmental releases of PFAS may have occurred. Pump and treat (P&T) remediation is the selected remedy for multiple groundwater contaminant plumes at Hanford. These P&T systems use ion exchange (IX) as a component of aboveground treatment, with the specific resins depending on the target contaminants. There is potential that these IX resins may be able to remove PFAS from groundwater, but investigation is needed to understand affinity/selectivity and removal capacity given the groundwater composition and the operating conditions. This report provides background on PFAS uses and chemistry, then provides a review of IX resin applications for PFAS, identifying knowledge gaps. Recommendations are provided regarding research needed to address knowledge gaps and acquire information needed to propose IX as a future PFAS remediation technology at the Hanford Site, as well as other U.S. Department of Energy sites. Generally, PFAS compounds are fluorinated substances that contain at least one fully fluorinated methyl or methylene carbon – with a few noted exceptions, any chemical with at least a perfluorinated methyl group (–CF3) or a perfluorinated methylene group (–CF2–) is a PFAS. These chemical compounds are characterized as non-biodegradable, non-reactive, non-photolytic, and hydrolysis resistant. This makes them highly recalcitrant within the environment, however polyfluoroalkyl materials are less recalcitrant as the carbon chains contain C–H bonds which are more easily broken than carbon – fluorine (C–F) bonds. The backbone carbon structures are commonly punctuated with a head group, the most well-known of them are perfluorooctanesulfonic acid and perfluorooctanoic acid, which possess a sulfonate and a carboxylate group, respectively. IX resins are marketed for the removal of PFAS from water systems and industrial water, however, the mechanism of removal is not as well understood as for anion or cation removal. A better understanding of the mechanism of removal would enable the development of IX resins that have improved specificity for PFAS removal. Four knowledge gaps were identified: 1) the effect of dissolved ions on the IX resin PFAS removal effectiveness, 2) the effect of additional primary contaminants of concern (PCOCs) or secondary contaminants of concern (SCOCs) on the effectiveness of PFAS via IX resin, 3) the mechanisms of PFAS removal from water, and 4) practical solutions to IX resin regeneration and waste disposal.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Evaluation of Hanford 200 West Area Tank Farms (241-S/241-SX-/241-U tank farms) Physical Properties Data for Use in Development of West Area Tank Treatment (WATT) Processing

With the recent acceptance of West Area Tank Treatment disposition alternative for 200 West Area tanks at the Hanford Site by the State of Washington and the U.S. Department of Energy, a review was initiated to identify the physical properties data available in the literature for the Hanford 241-S, 241-SX, and 241-U tank farms. The literature reviewed indicated that there is a relatively small set of useful data on physical properties of 200 West Area tanks, and the data that do exist are biased around a narrow range of tank samples. Much of the testing between the 1990s and mid-2010s was intended to support either enhanced sludge washing or feed delivery to the Pretreatment Facility at the Hanford Waste Treatment and Immobilization Plant. As such, some physical properties of 200 West Area samples were measured under conditions that are no longer relevant. Because of the distinctly different nature of many past processes at the 200 West Area compared to the 200 East Area, insight from waste testing in the 200 East Area waste should be used with caution, as there may be significantly different qualities in the physical properties data between these two areas (both in situ and as measured in laboratory analyses). Based on this assessment, there is a need to collect additional physical property data to support planning for 200 West Area retrievals.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Ambient airborne solids concentrations including volcanic ash at Hanford, Washington sampling sites subsequent to the Mount St. Helens eruption

Airborne solids concentrations were measured on a near daily basis at two Hanford, Washington sites after the eruption of Mount St. Helens on May 18, 1980. These sites are about 211 km east of Mount St. Helens. Collected airborne solids included resuspended volcanic ash plus normal ambient solids. Average airborne solids concentrations were greater at the Hanford meteorological station sampling site which is 24 km northwest of the Horn Rapids dam sampling site. These increased concentrations reflect the sampling site proximity to greater ash fallout depths. Both sites are in low ash fallout areas although the Hanford meteorological station site is closer to the greater ash fallout areas. Airborne solids concentrations were decreased by rain, but airborne solids concentrations rapidly increased as surfaces dried. Airborne concentrations tended to become nearly the same at both sampling sites only for July 12 and 13.

Sehmel, G. A.

Update on Integrity Monitoring, Prediction and Assessment, Corrosion Control, and Repair of the Hanford Storage Tanks

DOE has launched a multi-year research program with the focus of preserving and increasing available volume for waste storage at Hanford. The long-term availability and operability of the Hanford Double Shell Tanks (DST) is critical to the completion of the Hanford mission. Maintaining the integrity of the tank will involve having a technology for repair or refurbishment of a DST should the tank function be compromised by degradation, monitoring the tank for indications of accelerated degradation, developing a means for mitigating accelerated degradation, and evaluating options for increasing the storage capacity in the tank farm without constructing new tanks. The project work was started in the middle of 2024; significant progress has been made in the following four areas: (i) tank refurbishment using a high performance grout and an epoxy sealant layer system, (ii) developing a chemically and radiologically stable reference electrode, (iii) designing and implementing a cathodic protection system to mitigate underside corrosion of DST secondary shells, and (iv) exploring evaporation to increase waste storage capacity.

Shukla, Pavan [Savannah River National Laboratory

Hanford Site Raptor Nest Monitoring Report for Calendar Years 2024 and 2025

The focus of this report is to document the distribution and abundance of nesting raptors on the HFO-managed portion of the Hanford Site. Raptor nest surveys provide land managers with specific locations of nest sites so that the nests can be avoided and disturbances minimized during the nesting season. Long-term trends in nesting raptor populations also allow for the assessment of potential impacts from Hanford Site operations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN

Enhanced prediction of Cs removal by CST from Hanford tank waste with K accountability

Abstract The treatment of Hanford tank waste is one of the most challenging environmental cleanup activities to date. To expedite the processing of liquid waste stored in underground tanks in Washington State it is necessary to remove the significant dose contributor, 137 Cs. Crystalline silicotitanate ion exchanger is currently used to remove 137 Cs from the aqueous phase of Hanford tank wastes in preparation for vitrification at the Waste Treatment and Immobilization Plant (WTP). Improving the understanding of potassium impacts on ion exchange behavior of Cs will help in the operation of a critical component of one of the most complex treatment processes in the world today. Optimization of this process can result in significant cost savings and less waste production. Toward this effort, a series of batch contact tests varied in potassium concentration were conducted to look at the impact of potassium concentration on Cs distribution. Experimental distribution ratios ( K d ) were compared to the distribution ratios predicted using the ZAM model. A significant underprediction of Cs capacity in the presence of potassium was seen with the existing model. A revision of the equilibrium constants was determined and provided a statistically better fit for determining the Cs K d values in tank waste matrices.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W