Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HVAC systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Automated fault detection and diagnosis of airflow and refrigerant charge faults in residential HVAC systems using IoT-enabled measurements

While automated fault detection and diagnosis (AFDD) in residential heating, ventilation, and air-conditioning (HVAC) using smart thermostat data is gaining increasing attention in recent times, it still requires in-depth investigation for market adoption, especially with real-life data. Furthermore, this paper proposes an Internet of Things (IoT) - based approach that adds a smart sensor to the smart thermostat data to carry out AFDD. The approach uses a model which predicts enthalpy change across the evaporator and compares the prediction to the measured enthalpy change. Deviations which exceed analytically determined thresholds then signal faults in the HVAC system. The faults detected are either installation related or degradation related. Experimental tests were carried out in four homes located in Norman, Oklahoma. From the tests, installation issues like indoor/outdoor mismatch were detected in two homes, while a 30% low charge and low indoor airflow rate were detected in one home. The results show that the proposed AFDD algorithm was able to successfully detect two prevalent faults, namely low indoor airflow and low refrigerant charge. Unlike most of the smart thermostat-based approaches, the proposed IoT-based approach can detect and diagnose both faults but only require one additional sensor which is provided by smart thermostat manufacturers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains.Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling.The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

99 GENERAL AND MISCELLANEOUS↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Haxall-based (Axon) fault auto-correction package for building HVAC system (Haxall-based Fault Correction) v1.0

Haxall-based Fault Correction is a set of fault auto-correction algorithms implemented using the Axon language. These algorithms can automatically fix equipment and control problems as they arise and improve the operation of building Heating, Ventilation, and Air Conditioning (HVAC) systems. The coded auto-correction algorithms include mitigation of rogue zones, ASHRAE Guideline 36 static pressure and supply air reset, resolution of control hunting due to improper settings in a proportional-integral-derivative controller, correction of biased temperature sensors, etc. FDD tools with enhanced auto-correction capability can resolve control problems as they are detected, increasing energy savings and emissions reductions while freeing up operational staff expertise for the hardest facility problems.

Vitti, Raphael↗

Infrared-Fused Vision-Based Thermoregulation Performance Estimation for Personal Thermal Comfort-Driven HVAC System Controls

Thermal comfort is one of the primary factors influencing occupant health, well-being, and productivity in buildings. Existing thermal comfort systems require occupants to frequently communicate their comfort vote via a survey which is impractical as a long-term solution. Here, we present a novel thermal infrared-fused computer vision sensing method to capture thermoregulation performance in a non-intrusive and non-invasive manner. In this method, we align thermal and visible images, detect facial segments (i.e., nose, eyes, face boundary), and accordingly read the temperatures from the appropriate coordinates in the thermal image. We focus on the human face since it is often clearly visible to cameras and is not merged into a hot background (unlike hands). We use a regularized Gaussian Mixture model to track the thermoregulation changes over time and apply a heuristic algorithm to extract hot and cold indices. We present a personalized and a generalized comfort modeling method, selected based on the availability of the occupant historical indices measurements in a neutral environment, and use the time-series of the hot and cold indices to define corrections to HVAC system operations in the form of setpoint constraints. To evaluate the efficacy of our proposed approach in responding to thermal stimuli, we designed a series of controlled experiments to simulate exposure to cold and hot environments. While applying personalized modeling showed an acceptable average accuracy of 91.3%, the generalized model’s average accuracy was only 65.2%. This shows the importance of having access to physiological records in modeling and assessing comfort. We also found that individual differences should be considered in selecting the cooling and heating rates when some knowledge of the occupant’s overall thermal preference is available.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bringing Fault Detection and Diagnostics (FDD) Tools into the Mainstream: Retro Commissioning and Continuous Commissioning of HVAC and Refrigeration Systems

HVAC systems in the commercial building sector consume about 3.4 quads of energy annually. Of all the HVAC systems, packaged rooftop air–conditioning units (RTUs) provide cooling and heating for over 60 percent of the commercial building floorspace (about 90 billion ft2) in the U.S. and they are a significant source of energy consumption and peak demand. All HVAC systems suffer from faults that impact thermal comfort and increase energy consumption. There are several commercially available Automated Fault Detection and Diagnostic (AFDD) tools on the market that can detect and diagnose faults, and if those faults are corrected, can save significant national energy. However, there are multiple market barriers for these tools including lack of independent verification of their performance in the field in terms of their technical capabilities, ease of use and installation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cascaded Control for Building HVAC Systems in Practice

Actuator hunting is a widespread and often neglected problem in the HVAC field. Hunting is typically characterized by sustained or intermittent oscillations, and can result in decreased efficiency, increased actuator wear, and poor setpoint tracking. Cascaded control loops have been shown to effectively linearize system dynamics and reduce the prevalence of hunting. This paper details the implementation of cascaded control architectures for Air Handling Unit chilled water valves at three university campus buildings. A framework for implementation the control in existing Building Automation software is developed that requires only a single line of additional code. Results gathered for more than a year show that cascaded control not only eliminates hunting in control loops with documented hunting issues, but provides better tracking and more consistent performance during all seasons. A discussion of efficiency losses due to hunting behavior is presented and illustrated with comparative data. Furthermore, an analysis of cost savings from implementing cascaded chilled water valve control is presented. Field tests show 2.2–4.4% energy savings, with additional potential savings from reduced operational costs (i.e., maintenance and controller retuning).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Autonomous Anomaly Detection for MPC Forecasts of HVAC Systems in Residential Communities

The use of residential heating, ventilation, and air conditioning (HVAC) to shift peak demand or provide ancillary services is a potential solution in the presence of older grids and distributed renewables. However, to ensure the efficient use of devices, utilities need to accurately forecast the load and adopt error correction schemes when necessary. While significant theoretical research exists in the area of predictive control of HVAC, little experimental evidence exists. The lack of experimental data in turn causes researchers to be unprepared for unsystematic errors which emerge due to the higher complexity of the data generating process. This study offers an anomaly detection methodology that uses unsupervised machine learning algorithms to detect and isolate these errors with different forecast error ranges. The results of anomaly detection procedure can then be used for error correction and would eventually help develop better predictive controllers. The methodology is tested using real world data from a smart neighborhood that currently operates in Atlanta. GA.

Lebakula, Viswadeep↗

An evaluation of the demand response potential of integrated dynamic window and HVAC systems

Demand response (DR) increases the flexibility and reliability of the electricity grid as use of intermittent renewable energy sources increases. HVAC and envelope DR measures present the largest aggregate energy and peak demand savings potential of all commercial building end uses because their net demand savings occur during critical peak demand periods. Controllable envelope measures include switchable electrochromic windows, operable window attachments such as outdoor louvers, roller shades, and awnings, as well as other innovative facade technologies that can modulate both solar heat gain and daylight admission over a broad solar-optical range. This study evaluated the technical potential of DR-enabled dynamic windows to reduce critical peak demand for a prototypical medium office building situated in all 16 U.S. climates. Model predictive control (MPC) algorithms were designed to minimize electricity cost in daylit perimeter office zones through control of an electrochromic window with and without HVAC thermostat setpoint control. Conventional and time-of-use rates were used to shape the degree of DR. Median annual peak demand savings with window and thermostat control across all climate zones were 24.3 kW (4.4 W/m 2 ) per building or 15.9 W/m 2 for non-north perimeter zones. Resource adequacy at the whole building level was estimated to be 13.1 to 43.4 $/kW per year over the 30-year life of the installation. Co-benefits were increased energy efficiency, and reduced electricity cost and emissions. Visual and thermal comfort requirements were met at all times. Dynamic facades controlled by MPC have substantial technical potential for DR across all U.S. climates and warrant serious consideration for inclusion in DR portfolios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heating Ventilation Air-Conditioning (HVAC) System Analysis and Optimization for Revit with the OpenStudio Analytical Framework (CRADA Final Report)

This project proposes to integrate the NREL-developed OpenStudio (OS) and its accompanying Analytical Framework (OSAF) into Autodesk’s (ADSK’s) market leading suite of building information modeling (BIM) tools. As a result, BIM users will gain access to advanced (but user-friendly) building energy modeling (BEM), calibration, and design optimization capabilities. Following integration, the BIM software will automatically generate a consistent OS-based BEM model, allowing users to develop projects in an integrated manner, moving back and forth between architectural and engineering perspectives without redundancy or data loss, saving time and effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Validation of Packaged RAD-AC HVAC System: Efficiency and Load Shifting via Electrochemical Regeneration of Liquid Desiccants

In this project, Mojave and SRI have demonstrated field validation and load shifting of liquid desiccant air conditioning systems with two liquid desiccant dedicated outdoor air system (DOAS) air conditioner units – one employing traditional thermal desiccant regeneration and the other utilizing Mojave’s novel electrochemical desiccant regeneration technology based on Redox Assisted electrodialysis. The Redox Assisted Dehumidification Air Conditioning (RAD-AC) technology is further developed and validated in this work to demonstrate an Integrated Seasonal Moisture Removal Efficiency (ISMRE) > 5.0 kg/kWh and shifting of ≥ 10% electric load in ≤ 72 hours. Furthermore, the longevity and durability of Mojave’s liquid desiccant air conditioning technology is validated in field testing of the thermally regenerated unit, with the unit demonstrating operation with >90% uptime while experiencing an efficiency degradation of < 10% during a testing campaign of over 5400 hours.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Advances in supervisory control strategies for a heat pump centric HVAC system − a comprehensive review on applications

There is an increase in research investigating the development and deployment of supervisory controllers that enable high efficiency electrically driven vapor compression heat pumps operating within grid interactive efficient buildings to provide demand side management. This paper reviews over sixty relevant case studies within this domain that focus on commercial off-the-shelf heat pumps whose primary task is providing space conditioning. The concept of a heat pump-centric heating, ventilation, and air-conditioning system is introduced, accompanied by a detailed overview of various kinds of electric heat pumps and building-level thermal energy storage configurations. Additionally, the different types of supervisory controller designs, including rule-based control and model predictive control, are discussed, along with the various methods for communication between a supervisory controller and a downstream heat pump’s local controller. A comparative analysis is conducted in order to categorize the reviewed case studies based on their system design, supervisory control algorithm, and validation methodology. This detailed analysis allows the review to establish current research trends, identify potential gaps, and suggest future directions for the development of this technology. Overall, the authors recommend that more future research be devoted to low-cost practical retrofits that allow for easy integration of active thermal energy storage within heat pump-centric heating, ventilation, and air-conditioning system systems that utilize direct expansion heat pumps. We also suggest more research into the development and deployment of supervisory controllers that can properly communicate with commercial off-the-shelf heat pump local controller available control inputs, e.g., zone temperature setpoint. Lastly, more rigorous experimental demonstrations of advanced supervisory control within real and or closed-loop, transient/ quasi-steady state environments are necessary to reduce industry wide skepticism of this technology.

Demand side management↗