Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HVAC systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

25 records · Page 2

Effects of Solar Photovoltaic Panels on Roof Heat Transfer

Building Heating, Ventilation and Air Conditioning (HVAC) is a major contributor to urban energy use. In single story buildings with large surface area such as warehouses most of the heat enters through the roof. A rooftop modification that has not been examined experimentally is solar photovoltaic (PV) arrays. In California alone, several GW in residential and commercial rooftop PV are approved or in the planning stages. With the PV solar conversion efficiency ranging from 5-20% and a typical installed PV solar reflectance of 16-27%, 53-79% of the solar energy heats the panel. Most of this heat is then either transferred to the atmosphere or the building underneath. Consequently solar PV has indirect effects on roof heat transfer. The effect of rooftop PV systems on the building roof and indoor energy balance as well as their economic impacts on building HVAC costs have not been investigated. Roof calculator models currently do not account for rooftop modifications such as PV arrays. In this study, we report extensive measurements of a building containing a flush mount and a tilted solar PV array as well as exposed reference roof. Exterior air and surface temperature, wind speed, and solar radiation were measured and thermal infrared (TIR) images of the interior ceiling were taken. We found that in daytime the ceiling surface temperature under the PV arrays was significantly cooler than under the exposed roof. The maximum difference of 2.5 C was observed at around 1800h, close to typical time of peak energy demand. Conversely at night, the ceiling temperature under the PV arrays was warmer, especially for the array mounted flat onto the roof. A one dimensional conductive heat flux model was used to calculate the temperature profile through the roof. The heat flux into the bottom layer was used as an estimate of the heat flux into the building. The mean daytime heat flux (1200-2000 PST) under the exposed roof in the model was 14.0 Watts per square meter larger than under the tilted PV array. The maximum downward heat flux was 18.7 Watts per square meters for the exposed roof and 7.0 Watts per square meters under the tilted PV array, a 63% reduction due to the PV array. This study is unique as the impact of tilted and flush PV arrays could be compared against a typical exposed roof at the same roof for a commercial uninhabited building with exposed ceiling and consisting only of the building envelope. Our results indicate a more comfortable indoor environment in PV covered buildings without HVAC both in hotter and cooler seasons.

Dominguez, A.↗

The MIST /MIUS Integration and Subsystems Test/ laboratory - A testbed for the MIUS /Modular Integrated Utility System/ program

The MIUS (Modular Integrated Utility System) concept is to be an energy-conserving, economically feasible, integrated community utility system to provide five necessary services: electricity generation, space heating and air conditioning, solid waste processing, liquid waste processing, and residential water purification. The MIST (MIUS Integration and Subsystem Test) integrated system testbed constructed at the Johnson Space Center in Houston includes subsystems for power generation, heating, ventilation, and air conditioning (HVAC), wastewater management, solid waste management, and control and monitoring. The key design issues under study include thermal integration and distribution techniques, thermal storage, integration of subsystems controls and displays, incinerator performance, effluent characteristics, and odor control.

Beckham, W. S., Jr.↗

Lunar Base Heat Pump

The objective of this project was to investigate the feasibility of constructing a heat pump suitable for use as a heat rejection device in applications such as a lunar base. In this situation, direct heat rejection through the use of radiators is not possible at a temperature suitable for lde support systems. Initial analysis of a heat pump of this type called for a temperature lift of approximately 378 deg. K, which is considerably higher than is commonly called for in HVAC and refrigeration applications where heat pumps are most often employed. Also because of the variation of the rejection temperature (from 100 to 381 deg. K), extreme flexibility in the configuration and operation of the heat pump is required. A three-stage compression cycle using a refrigerant such as CFC-11 or HCFC-123 was formulated with operation possible with one, two or three stages of compression. Also, to meet the redundancy requirements, compression was divided up over multiple compressors in each stage. A control scheme was devised that allowed these multiple compressors to be operated as required so that the heat pump could perform with variable heat loads and rejection conditions. A prototype heat pump was designed and constructed to investigate the key elements of the high-lift heat pump concept. Control software was written and implemented in the prototype to allow fully automatic operation. The heat pump was capable of operation over a wide range of rejection temperatures and cooling loads, while maintaining cooling water temperature well within the required specification of 40 deg. C +/- 1.7 deg. C. This performance was verified through testing.

Walker, D.↗

Inertial Centrifugal-Based Pre-filter for Spacecraft Life Support Systems

The intrusion of planetary dust inside space vehicles on future Lunar missions may lead to performance compromises of the cabin air-filtration system. The evasive character of the fine planetary dust, in particular lunar dust, could enable the dust to make its way through the seals and barriers of the EVA hatches and become airborne in the cabin. This can result in performance and capacity overload of the high efficiency filter media and particle separation systems. Adequate pre-filtration can substantially reduce the load on the higher efficiency components leading to smaller dust loads during surge and nominal dust loading conditions, thereby protecting and extending the life of these components. A particle separation concept, based on centrifugal separation, is being investigated for its application as a pre-filter. The concept has previously been proposed for application in the aircraft engine industry, as means of capturing corrosive dust and salt deposits that may harm the engine. The technique has the advantages of being passive, integrable to HVAC and space vehicle architecture, and has the potential for high degree of particle separation with proper fluid dynamic design. Computational Fluid Dynamics (CFD) and particle tracing modeling were used to arrive at an initial design for rapid prototyping and testing. If feasible, the concept can be integrated to the Scroll Filter System which is being developed by NASA to address the filtration demands on long during spaceflight and surface missions. This paper will describe the modeling results of this concept.

Life Support Systems↗

Inertial Centrifugal-Based Pre-filter for Spacecraft Life Support Systems

The intrusion of planetary dust inside space vehicles on future Lunar missions may lead to performance compromises of the cabin air-filtration system. The evasive character of the fine planetary dust, in particular lunar dust, could enable the dust to make its way through the seals and barriers of the EVA hatches and become airborne in the cabin. This can result in performance and capacity overload of the high efficiency filter media and particle separation systems. Adequate pre-filtration can substantially reduce the load on the higher efficiency components leading to smaller dust loads during surge and nominal dust loading conditions, thereby protecting and extending the life of these components. A particle separation concept, based on centrifugal separation, is being investigated for its application as a pre-filter. The concept has previously been proposed for application in the aircraft engine industry, as means of capturing corrosive dust and salt deposits that may harm the engine. The technique has the advantages of being passive, integrable to HVAC and space vehicle architecture, and has the potential for high degree of particle separation with proper fluid dynamic design. Computational Fluid Dynamics (CFD) and particle tracing modeling were used to arrive at an initial design for rapid prototyping and testing. If feasible, the concept can be integrated to the Scroll Filter System which is being developed by NASA to address the filtration demands on long during spaceflight and surface missions. This paper will describe the modeling results of this concept.

Life Support Systems↗

Develop and test fuel cell powered on-site integrated total energy systems: Phase 3: Full-scale power plant development

The development of a commercially viable and cost-effective phospheric acid fuel cell powered on-site integrated energy system (OS/IES) is described. The fuel cell offers energy efficients in the range of 35-40% of the higher heating value of available fuels in the form of electrical energy. In addition, by utilizing the thermal energy generated for heating, ventilating and air-conditioning (HVAC), a fuel cell OS/IES could provide total energy efficiencies in the neighborhood of 80%. Also, the Engelhard fuel cell OS/IES offers the important incentive of replacing imported oil with domestically produced methanol, including coal-derived methanol.

Source record↗

Progress on the CO2 Removal and Compression System

The Carbon Dioxide Removal and Compression System (CRCS) is designed to perform both the Carbon Dioxide(CO2) removal and compress CO2 for further processing. The CRCS was designed as a lower power requirement option to the one currently being used on the International Space Station (ISS). This paper describes the final design, fabrication, assembly, and testing of the integrated CRCS. Initial results indicated that the spiral heaters used did not yield uniform heating within both the adsorption and compression beds. In addition, the heaters for the compression bed were insufficient and an additional HVAC jacket was employed to provide heat to the bed.

Air Revitalization↗