Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HIV-1”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

22 records · Page 2

Small Ion Channel Linking Molecular Simulations and Electrophysiology

Ion channels are pore-forming protein assemblies that mediate the transport of small ions across cell membranes. Otherwise, membrane bilayers would be almost impermeable to ions incapable to traverse the low dielectric constant, hydrophobic membrane core. Ion channels are ubiquitous to all life forms. In humans and other higher organisms they play the central role in conducting nerve impulses, cardiac functions, muscle contraction and apoptosis. On the other extreme of biological complexity, viral ion channels (viroporins) influence many stages of the virus infection cycle either through regulating virus replication, such as entry, assembly and release or modulating the electrochemical balance in the subcellular compartments of host cells. Ion channels were crucial components of protocells. Their emergence facilitated adaptation of nascent life to different environmental conditions. The earliest ion channels must have been much simpler than most of their modern ancestors. Viral channels are among only a few naturally occurring models to study the structure, function and evolution of primordial channels. Experimental studies of these properties are difficult and often unreliable. In principle, computational methods, and molecular dynamics (MD) simulations in particular, can aid in providing information about both the structure and the function of ion channels. However, MD suffers from its own problems, such as inability to access sufficiently long time scales or limited accuracy of force fields. It is, therefore, essential to determine the reliability of MD simulations. We propose to do so on the basis of two criteria. One is channel stability on time scales that extend for several microseconds or longer. The other is the ability to reproduce the measured ionic conductance as a function of applied voltage. If both the stability and the calculated ionic conductance are satisfactory it will greatly increase our confidence that the structure and the function of a channel are described sufficiently accurately. To our knowledge, long time scale stability (approx.10 micro-sec) and the correct electrophysiology have been shown so far for only one channel - the synthetic LS3 hexamer). In this presentation, this approach will be discussed in application to two viral channels - Vpu, encoded by the HIV-1 genome and p7 of hepatitis C.

Pohorille, Andrzej↗

Simple Ion Channels: From Structure to Electrophysiology and Back

A reliable way to establish whether our understanding of a channel is satisfactory is to reproduce its measured ionic conductance over a broad range of applied voltages in computer simulations. In molecular dynamics (MD), this can be done by way of applying an external electric field to the system and counting the number of ions that traverse the channel per unit time. Since this approach is computationally very expensive, we have developed a markedly more efficient alternative in which MD is combined with the electrodiffusion (ED) equation. In this approach, the assumptions of the ED equation can be rigorously tested, and the precision and consistency of the calculated conductance can be determined. We have demonstrated that the full current/voltage dependence and the underlying free energy profile for a simple channel can be reliably calculated from equilibrium or non-equilibrium MD simulations at a single voltage. To carry out MD simulations, a structural model of a channel has to be assumed, which is an important constraint, considering that high-resolution structures are available for only very few simple channels. If the comparison of calculated ionic conductance with electrophysiological data is satisfactory, it greatly increases our confidence that the structure and the function are described sufficiently accurately. We examined the validity of the ED for several channels embedded in phospholipid membranes - four naturally occurring channels: trichotoxin, alamethicin, p7 from hepatitis C virus (HCV) and Vpu from the HIV-1 virus, and a synthetic, hexameric channel, formed by a 21-residue peptide that contains only leucine and serine. All these channels mediate transport of potassium and chloride ions. It was found that the ED equation is satisfactory for these systems. In some of them experimental and calculated electrophysiological properties are in good agreement, whereas in others there are strong indications that the structural models are incorrect.

molecular dynamics (MD↗

Ion Channels – From Structure to Electrophysiology and Back

A reliable way to establish whether our understanding of a channel is satisfactory is to reproduce its measured ionic conductance over a broad range of applied voltages in computer simulations. In molecular dynamics (MD), this can be done by way of applying an external electric field to the system and counting the number of ions that traverse the channel per unit time. Since this approach is computationally very expensive, we have developed a markedly more efficient alternative in which MD is combined with the electrodiffusion (ED) equation. In this approach, the assumptions of the ED equation can be rigorously tested, and the precision and consistency of the calculated conductance can be determined. We have demonstrated that the full current/voltage dependence and the underlying free energy profile for a simple channel can be reliably calculated from equilibrium or non-equilibrium MD simulations at a single voltage. Free energy profiles can be obtained from non-equilibrium simulations without a loss of accuracy even without the knowledge of diffusion coefficient. To carry out MD simulations, a structural model of a channel has to be assumed, which is an important constraint, considering that high-resolution structures are available for only very few simple channels. If the comparison of calculated ionic conductance with electrophysiological data is satisfactory, it greatly increases our confidence that the structure and the function are described sufficiently accurately. We examined the validity of the ED for several channels embedded in phospholipid membranes - four naturally occurring channels: trichotoxin, alamethicin, p7 from hepatitis C virus (HCV) and Vpu from the HIV-1 virus, a synthetic, hexameric channel, formed by a 21-residue peptide that contains only leucine and serine and a bacterial pentameric ligand-gated ion channel, GLIC. All these channels mediate transport of potassium and chloride ions. It was found that the ED equation is satisfactory for these systems. In some of them, experimental and calculated electrophysiological properties are in good agreement, whereas in others there are strong indications that the structural models are incorrect.

Pohorille, Andrew↗

Epstein-Barr virus and human immunodeficiency virus serological responses and viral burdens in HIV-infected patients treated with HAART

Epstein-Barr virus (EBV) associated non-Hodgkin lymphoma is recognized as a complication of human immunodeficiency virus (HIV) infection. Little is known regarding the influence of highly active antiretroviral therapy (HAART) on the biology of EBV in this population. To characterize the EBV- and HIV-specific serological responses together with EBV DNA levels in a cohort of HIV-infected adults treated with HAART, a study was conducted to compare EBV and HIV serologies and EBV DNA copy number (DNAemia) over a 12-month period after the commencement of HAART. All patients were seropositive for EBV at baseline. Approximately 50% of patients had detectable EBV DNA at baseline, and 27/30 had detectable EBV DNA at some point over the follow-up period of 1 year. Changes in EBV DNA copy number over time for any individual were unpredictable. Significant increases in the levels of Epstein-Barr nuclear antigen (EBNA) and Epstein-Barr early antigen (EA) antibodies were demonstrated in the 17 patients who had a good response to HAART. Of 29 patients with paired samples tested, four-fold or greater increases in titers were detected for EA in 12/29 (41%), for EBNA in 7/29 (24%), for VCA-IgG in 4/29 (14%); four-fold decreases in titers were detected in 2/29 (7%) for EA and 12/29 (41%) for EBNA. A significant decline in the titer of anti-HIV antibodies was also demonstrated. It was concluded that patients with advanced HIV infection who respond to HAART have an increase in their EBV specific antibodies and a decrease in their HIV-specific antibodies. For the cohort overall, there was a transient increase in EBV DNA levels that had declined by 12 months. Copyright 2002 Wiley-Liss, Inc.

NASA Discipline Regulatory Physiology↗