Creep at elevated temperatures and high vacuum Semiannual report no. 4
Creep tests on high purity copper wires in high vacuum in argon bombarded clean state and after oxidization in air
High-vacuum system for teaching and research.
High vacuum system of low cost noting operating principles, layout, construction, operating sequences, performance and simplicity
Updates of the KArLE Experiment: New Libs Calibration Under High Vacuum for the Quantification of Potassium in Basalt for In Situ Geochronology
In planetary exploration, in situ absolute geochronology is one of the main important measurements that needs to be accomplished. Until now, on Mars, the age of the surface is only determined by crater density counting, which gives relative ages. These ages can have a lot of uncertainty as they depend on many parameters. More than that, the curves must be ties to absolute ages. Thus far, only the lost lander Beagle 2 was designed to conduct absolute geochronology measurements, though some recent attempts using MSL Curiosity show that this investigation is feasible and should be strongly encouraged for future flight. Experimental: The Potassium (K)-Argon Laser Experiment (KArLE) is being developed at MSFC through the NASA Planetary Instrument Definition and Development Program (PIDDP). The goal of this experiment is to provide in situ geochronology based on the K-Ar method. A laser ablates a rock under high vacuum, creating a plasma which is sensed by an optical spectrometer to do Laser Induced Breakdown Spectroscopy (LIBS). The ablated material frees gases, including radiogenic 40Ar,which is measured by a mass spectrometer (MS). As the potassium is a content and the 40Ar is a quantity, the ablated mass needed in order to relate them. The mass is given by the product of the ablated volume by the density of this material. So we determine the mineralogy of the ablated material with the LIBS spectra and images and calculate its density. The volume of the pit is measured by using microscopy. LIBS measurement of K under high vacuum: Three independant projects [1, 2, 3] including KArLE, are developing geochronological instruments based on this LA-LIBS-MS method. Despite several differences in their setup, all of them have validated the methods with analyses and ages. However, they all described difficulties with the LIBS measurements of K [3,4]. At ambient pressure, the quantification of K by LIBS on geological materials can be accurate [5]. However the protocol of the LA-LIBS-MS experiment required hundreds of shots under high vacuum in order to free enough 40Ar* to be measured by the QMS. This long duration of ablation may induces significant changes in the LIBS spectra. The pressure may increases by orders of magnitudewithin the chamber and the laser pit geometry can change the effectiveness of ablation and intensity of plasma light received. These effects introduce variation between the first and last spectra and so the quantification of K is more complex. The ablation of one crater can give, depending on the protocol of acquisition, from tens to hundreds of spectra. Protocol and results: We are in the process of further characterizing the variation introduced into LIBS spectra by the use of hundreds of laser shots, and definining a protocol that can be used to ensure accuracy and reporoducibility in the results.We are using natural rock powder standards fused in a furnace, as well as mars analog samples with known K content. We will show the result of the calibration and some new statistical approaches in order to apprehend the effects of the long time ablation on rocks under high vacuum.
Lubrication and wear fundamentals for high vacuum applications
Lubrication, and friction and wear concepts for high vacuum applications
The effect of surface oxide layer on the rate of hydrogen emission from aluminum and its alloys in a high vacuum
The influence of surface oxide layers on the kinetics of hydrogen emission at the high vacuum of 10 to the minus 8th power torr was investigated at temperatures from 20 to 450 C using samples of pure AB00 aluminum and the cast alloy AMg. Cast and deformed samples of AMts alloy were used to study the effect of oxide film thickness on the rate of hydrogen emission. Thermodynamic calculations of the reactions of the generation and dissociation of aluminum oxide show that degasification at elevated temperatures (up to 600 C) and high vacuum will not reduce the thickness of artificially-generated surface oxide layers on aluminum and its alloys.
High-vacuum Technology, Testing, 154 Measurement Meeting Compilation of papers
Papers presented at high vacuum simulation techniques conference
Combination double door high-vacuum valve provides access to vacuum chamber
Double door provides an extreme high vacuum seal as well as access to a vacuum chamber for insertion of test devices into the vacuum environment. This arrangement is applicable to any vacuum chamber and could be of value in cryopumping or mechanically pumped chambers.
Low-Cost, Rugged High-Vacuum System
A need exists for miniaturized, rugged, low-cost high-vacuum systems. Recent advances in sensor technology have led to the development of very small mass spectrometer detectors as well as other analytical instruments such as scanning electron microscopes. However, the vacuum systems to support these sensors remain large, heavy, and power-hungry. To meet this need, a miniaturized vacuum system was developed based on a very small, rugged, and inexpensive-to-manufacture molecular drag pump (MDP). The MDP is enabled by a miniature, very-high-speed (200,000 rpm), rugged, low-power, brushless DC motor optimized for wide temperature operation and long life. The key advantages of the pump are reduced cost and improved ruggedness compared to other mechanical hig-hvacuum pumps. The machining of the rotor and stators is very simple compared to that necessary to fabricate rotor and stator blades for other pump designs. Also, the symmetry of the rotor is such that dynamic balancing of the rotor will likely not be necessary. Finally, the number of parts in the unit is cut by nearly a factor of three over competing designs. The new pump forms the heart of a complete vacuum system optimized to support analytical instruments in terrestrial applications and on spacecraft and planetary landers. The MDP achieves high vacuum coupled to a ruggedized diaphragm rough pump. Instead of the relatively complicated rotor and stator blades used in turbomolecular pumps, the rotor in the MDP consists of a simple, smooth cylinder of aluminum. This will turn at approximately 200,000 rpm inside an outer stator housing. The pump stator comprises a cylindrical aluminum housing with one or more specially designed grooves that serve as flow channels. To minimize the length of the pump, the gas is forced down the flow channels of the outer stator to the base of the pump. The gas is then turned and pulled toward the top through a second set of channels cut into an inner stator housing that surrounds the motor. The compressed gas then flows down channels in the motor housing to the exhaust port of the pump. The exhaust port of the pump is connected to a commercially available diaphragm or scroll pump.
Effect of high vacuum on the fatigue properties of magnesium and two magnesium alloys.
High vacuum environment and vacuum outgassing time effects on magnesium alloys fatigue properties under constant load and reversed bending
Improved molecular sorbent trap for high-vacuum systems
Closed cycle refrigeration loop in which trays holding molecular sorbent are made to serve as cooling baffles improves the performance of high vacuum systems. High performance is obtained with almost no decrease in pumping speed.
Extension of gage calibration study in extreme high vacuum /orbitron and magnetron studies/
Orbitron and magnetron studies for gauge calibration in extreme high vacuum
Thermocouples of tantalum and rhenium alloys for more stable vacuum-high temperature performance
Thermocouples of the present invention provide stability and performance reliability in systems involving high temperatures and vacuums by employing a bimetallic thermocouple sensor wherein each metal of the sensor is selected from a group of metals comprising tantalum and rhenium and alloys containing only those two metals. The tantalum, rhenium thermocouple sensor alloys provide bare metal thermocouple sensors having advantageous vapor pressure compatibilities and performance characteristics. The compatibility and physical characteristics of the thermocouple sensor alloys of the present invention result in improved emf, temperature properties and thermocouple hot junction performance. The thermocouples formed of the tantalum, rhenium alloys exhibit reliability and performance stability in systems involving high temperatures and vacuums and are adaptable to space propulsion and power systems and nuclear environments.
Cryogen-free modular scanning tunneling microscope operating at 4-K in high magnetic field on a compact ultra-high vacuum platform
One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen-free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high magnetic field (HF), and compatibility with μm-sized samples, pose additional challenges to an already ambitious build. We present the design, construction, and performance of a cryogen-free, UHV, low temperature, and high magnetic field system for modular STM operation. An internal vibration isolator reduces vibrations in this system, allowing for atomic resolution STM imaging while maintaining a low base temperature of ∼4 K and magnetic fields up to 9 T. Samples and tips can be conditioned in situ utilizing a heating stage, an ion sputtering gun, an e-beam evaporator, a tip treater, and sample exfoliation. In situ sample and tip exchange and alignment are performed in a connected UHV room temperature stage with optical access. Multisite operation without breaking vacuum is enabled by a unique quick-connect STM head design. A novel low-profile vertical transfer mechanism permits transferring the STM between room temperature and the low temperature cryostat.
Elevated temperature fatigue of TZC MOLYBDENUM alloy under high frequency and high vacuum conditions
Elevated temperature fatigue of TZC molybdenum alloy determined in high frequency and high vacuum tests
Tribological characteristics of perfluoropolyether liquid lubricants under sliding conditions in high vacuum
Tribological characteristics of three PFPE's (Fomblin Z, Demnum, and Krytox) were studied under high vacuum using a four-ball apparatus with 440C steel specimens. Fomblin Z and Demnum exhibited initial scuffing-like high friction whereas Krytox did not. Steady state friction with Fomblin Z was the lowest among the three oils. Frictional values for Demnum and Krytox were almost the same. The lowest wear rate in air was provided by Krytox regardless of load, and low wear rates in vacuum at high load were achieved with Krytox and Demnum. Results are explained by reactivity and pressure-viscosity characteristics of the oils.
High-vacuum condenser tank for ion rocket tests Patent
High-vacuum condenser tank for testing ion rocket engines
Long time creep behavior of tantalum-10 tungsten in high vacuum