Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEAT repeats”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Abnormal grain growth of 68Cu–16Al–16Zn alloys for elastocaloric cooling via cyclical heat treatments

Abstract Cu-based superelastic shape memory alloys are promising for low-stress elastocaloric cooling. We have synthesized bulk alloys of 68Cu–16Al–16Zn under different conditions in order to promote its grain growth and enhance its elastocaloric properties. High-temperature x-ray diffraction of untreated 68Cu–16Al–16Zn alloy showed that the phase boundary between the α + β mixed phases and the high temperature phase ( β phase) was between 973 K and 1023 K. Based on this result, the 68Cu–16Al–16Zn alloy was heated and cooled in a furnace repeatedly between 773 K and 1173 K. The maximum grain size after heat treatment of the ingot rolled to 67% reached 11.1 mm. The latent heat of the martensitic transformation after grain growth was 6.3 J g −1 , which is higher than the previously reported value for the compound. The stress–strain curve of 68Cu–16Al–16Zn rolled to 67% rolling with cyclical heat treatments showed a maximum stress of 106 MPa at 4.5% strain, with adiabatic temperature change of 5.9 K in heating during stress loading and 5.6 K in cooling in stress removal. Furthermore, no fatigue in the stress–strain behavior was observed up to at least 60 000 mechanical cycles at 2% strain.

36 MATERIALS SCIENCE↗

Novel Functional Thermal Energy Storage Materials for Buildings Applications

The leakage of solid-liquid phase change materials (PCMs) tremendously limits their long-term application in thermal energy storage (TES). In this work, we present durable and form-stable shape-stabilized PCMs (ss-PCMs) for TES in building envelopes. These ss-PCMs are fabricated by encapsulating polyethylene glycol (PEG) consisting of different molecular weights within mesoporous magnesium oxide and silica dioxide. For the first time, the phase transition temperature (Tt) of ss-PCMs has been fine-tuned synthetically to be comfortable to building occupants by utilizing PEG blends with molecular weights of 600 and 800 g/mol. Several parameters, including surface hydrophilicity/hydrophobicity, surface area, and PCM loading percentage, have been studied to maximize the latent heat enthalpy for high energy efficiency and maintain form stability. The best ss-PCM candidate with suitable Tt and appreciable latent heat enthalpy exhibits a repeatable phase change behavior for up to 1,000 thermal cycles without leakage, which provides a promising solution for durable TES in buildings. The Tt tunability extends its application over a wider temperature range beyond buildings.

building envelope↗

Corrosion-Resistant Plug Materials for Geothermal Well Fluid Control

Conventional cements and plugs are challenged by corrosion in CO 2 -rich and extreme geothermal environments, due to the hostile chemistry and high temperatures. Thermite-based sealing and well intervention technologies are being applied in the oil and gas industry, combining the energy delivery capability of thermite materials with the sealing characteristics of low melt temperature alloys. The thermite reaction products (ceramics) and the sealing alloys used in these plugs both have very attractive corrosion properties, and their operating envelopes extend into geothermal conditions. Thermite plugs and platforms, without supplemental sealing materials, have been considered for nuclear waste isolation, carbon sequestration, and geothermal applications due to the geochemical stability of the ceramic product and its very high service temperature. This study addresses corrosion resistance of the thermite reaction products. A range of engineered thermite systems which yield thermite reaction products including pure aluminum oxide, feldspar, or aluminosilicate solid solutions (in addition to the iron produced in thermite reactions) was developed. These materials were evaluated for their strong acid resistance (pH 1), carbonate resistance (sodium carbonate) and thermal shock resistance (600 °C heating → cold water quenching repeated three times). Performance of different materials was evaluated based on the changes in mechanical properties, water-fillable porosity, phase changes under stress conditions. The aluminosilicate product exhibited very good corrosion resistance, both from material loss and strength perspectives, while the other products performed with varying degrees of stability. This paper presents the results of the thermite corrosion studies and describes the novel tools being deployed, and under development, to satisfy challenging barrier and intervention applications.

02 PETROLEUM↗

Experimental Operation of a Prototype 750C Advanced Chloride Molten Salt Bellows Valve

To achieve DOE 2030 SunShot targets that reduce the cost of liquid-based solar by an additional 40% to 70% beyond 2018 costs, a more reliable, highly manufacturable flow valve, capable of achieving operational temperatures of >700°C is required [1]. This paper investigates the development of an innovative high-temperature chloride molten salt valve, with operation up to 750°C. This valve is intended to be employed within Gen 3 CSP liquid-based thermal energy storage (TES) systems as well as Gen 4 modular salt reactor (MSR) technologies. This work details the general design and flow testing of a bellows-seal flow control valve (FCV). This design includes an integrated closed-loop thermal control system to ensure robust design for freeze-thaw cycles. The self-contained thermal management STM system, is unique in the salt valve industry since it is an integrated solution to provide a consistent, repeatable alternative to typical heat tracing. Additionally, the design includes the employment of a novel heat pipe valve stem to facilitate enhanced passive thermal management into the valve assembly. This valve stem heat pipe is designed to facilitate natural circulation within the bonnet to ensure robust operation, during both nominal and transient thermal operation. The valve body and trim will be designed using SS316H, consistent with Flowserve Corporation’s existing product base and is code qualified but will utilize clad material for materials corrosion, manufacturing cost reduction and compatibility to ensure design flexibility. A test campaign was performed in this investigation utilizing a novel 750°C ternary chloride (20%NaCl/40%MgCl2/40%KCl by mol. wt. %) molten salt flow loop. A discussion about the design and installation of the valves within this test bed is provided for this investigation. Valve test results from this study assessed Cv curves as well as multiple actuator cycles, under varying thermodynamic and operational mode conditions, which would be characteristic within a commercial molten salt facility. The results indicate nominal operation for the baseline design, though improved performance and reliability is expected with the full designed FCV.

Armijo, Kenneth (ORCID:0000000346832147)↗

Disorder-induced time effect in the antiferromagnetic domain state of Fe 1+ y Te

Herein we report on temperature-dependent soft X-ray absorption spectroscopy (XAS) measurements utilizing linearly polarized synchrotron radiation to probe magnetic phase transitions in iron-rich Fe 1+y Te (y ≈ 0.12). X-ray magnetic linear dichroism (XMLD) signals, which sense magnetic ordering processes at surfaces, start to increase monotonically below the Néel temperature T N = 57 K. This increase is due to a progressive bicollinear antiferromagnetic (AFM) alignment of Fe spins of the monoclinic Fe 1+y Te parent phase. This AFM alignment was achieved by a [1 0 0]-oriented biasing field favoring a single-domain state during cooling across T N . Our specific heat and magnetization measurements confirm the bulk character of this AFM phase transition. On longer time scales, however, we observe that the field-biased AFM state is highly unstable even at the lowest temperature of T = 3 K. After switching off the biasing field, the XMLD signal decays exponentially with a time constant τ = 1506 s. The initial XMLD signal is restored only upon repeating a cycle consisting of heating and field-cooling through T N . We explain the time effect by a gradual formation of a multi-domain state with 90° rotated AFM domains, promoted by structural disorder, facilitating the motion of twin-domains. Significant disorder in our Fe 1+y Te sample is evident from our X-ray diffraction and specific heat data. The stability of magnetic phases in Fe-chalcogenides is an important material property, since the Fe(Te 1-x Se x ) phase diagram shows magnetism intimately connected with superconductivity.

36 MATERIALS SCIENCE↗

Constraining dark matter substructure with Gaia wide binaries

ABSTRACT We use a catalogue of stellar binaries with wide separations (up to 1 pc) identified by the Gaia satellite to constrain the presence of extended substructure within the Milky Way galaxy. Heating of the binaries through repeated encounters with substructure results in a characteristic distribution of binary separations, allowing constraints to be placed independent of the formation mechanism of wide binaries. Across a wide range of subhalo density profiles, we show that subhaloes with masses $\gtrsim 65\, \mathrm{ M}_\odot$ and characteristic length scales similar to the separation of these wide binaries cannot make up 100 per cent of the Galaxy’s dark matter. Constraints weaken for subhaloes with larger length scales and are dependent on their density profiles. For such large subhaloes, higher central densities lead to stronger constraints. Subhaloes with density profiles similar to those expected from cold dark matter must be at least ∼5000 times denser than predicted by simulation to be constrained by the wide binary catalogue.

Astronomy & Astrophysics↗

Robust Combined Heat and Hybrid Power (CHHP) for High Electrical Efficiency Cogeneration

Georgia Tech (Prime Recipient), the University of Texas at El Paso (UTEP) and the National Energy Technology Laboratory (NETL) investigated a hybrid fuel cell/ gas turbine system concept as a combined heat and hybrid power (CHHP) system for both robust and high power-to-process heat ratio cogeneration. The novelty of the proposed system entailed the distinct, elevated electrical efficiencies it maintains while simultaneously supporting a broad span of heating needs (e.g., supply temperatures) demanded across variable heat loads. The scope included: 1) leveraging a pioneering national lab facility configured for dynamic system operability development of hybrid fuel cell/gas turbine cycles; 2) enabling technology development to adjust and modulate the quality and quantity of thermal supply to bottoming heat loads via novel extreme temperature gas bypass valves. Hybrid fuel cell/gas turbine systems have primarily been reduced-to-practice in a constrained (e.g., initial proof-of-concept) manner and have still demonstrated considerable electrical efficiencies. However, these pre-pilot systems have focused upon electrical efficiencies and electrical power generation as the exclusive energy demand. Such hybrid systems had not been extensively researched or developed for flexible and variable operation consisting of both power and heat demands; however, these variable combined power and heat demands are characteristic of many types of manufacturers such as animal/poultry processing, bakeries and milk/flour/pastry manufacturing, textile mills, and electrochemical processing. Commercially, developing the system into a working combined heat and power system benefits these types of manufacturers by allowing them to meet their power and heat demands at a lower cost, higher efficiency, and/or through onsite generation. Therefore, the technical scope of this project was largely to study and facilitate these hybrid systems as combined heat and hybrid power (CHHP) systems that include dynamic operability for variable heat and power loads and/or grid dynamics for various types of manufacturers. Simulation results were used to predict the performance of the CHHP system and conceptually develop it to achieve desired dynamic operability. Experimentally, the primary goal was to design, manufacture, and experiment upon a high-temperature bypass valve. Experimental data included air mass flow rates through the valve orifice when the valve was changed to variable extent between fully closed and fully open. The experimental data was then used to create a semi-empirical computational model of the bypass valve. Concluded simulation goals for the research included developing computational heat exchanger models for the hybrid system inclusive of the bottoming heat exchanger and the recuperative heat exchanger, and then combining the computational recuperator model with the computational valve model. Afterwards, the computational models were then integrated to predict the dynamic operation of hybrid fuel cell/gas turbine cycles throughout a design space and reporting such. The scope stated in the preceding paragraph was packaged into five specific goals: 1) enabling the simulation of dynamic combined heat and power through the creation of computational, modular heat exchanger models; 2) simulation and exploration of the CHHP system’s performance by integrating the heat exchanger models with the national lab’s pre-existing hybrid system (computational) simulation, but without the recuperator bypass valve concept in order to initially determine how the (baseline) system behaves and can be controlled in order to meet variable heat and power demands; 3) development and initial deployment of the high-temperature recuperator bypass valve technology in order to confirm and characterize the approach; 4) usage of the experimental data for the valve to create a semi-empirical computational model for the bypass valve which could then be combined with the heat exchanger computational models; 5) repeat of the second task of simulating and exploring the system’s performance, but this time including the bypass valve to resolve its efficacy. Tasks were successfully completed, and the general notion of flexibly operating, high electrical efficiency CHHP was further corroborated. Supportive details are provided in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AmeriFlux US-GL1 Stannard Rock

This is the AmeriFlux version of the carbon flux data for the site US-GL1 Stannard Rock. Site Description - Stannard Rock is located 39 km from the nearest shore (Keweenaw Peninsula) in Lake Superior, 44 miles NNE of Marquette, Michigan, and 24 miles ESE of Manitou Island. The site is located on the historic Stannard Rock Lighthouse, which was completed in 1882. Eddy covariance instrumentation was installed in 2008 by a network of scientists from both US and Canada, eventually to be called the Great Lakes Evaporation Network (GLEN). The intent of GLEN has been to provide observations of over-lake meteorology and evaporation, improve forecasting of Great Lakes water levels, and support a wide variety of stakeholders, including the National Weather Service (NWS), Environment and Climate Change Canada, National Oceanic and Atmospheric Administration, U.S. Coast Guard, recreational boaters and commercial shipping, emergency management officials, and the Great Lakes research community. The eddy covariance station along with other ancillary meteorological instrumentation is located at an approximate elevation of 39.2 meters above mean lake water level. Meteorological data from the lighthouse are sent to the National Data Buoy Center, where they can be viewed in real-time at http://www.ndbc.noaa.gov/station_page.php?station=stdm4 Uncorrected half-hour fluxes were computed directly on the logger using a 30-minute block averaging period as high-frequency data were not available. The half hour flux measurements downloaded from the datalogger were post-processed with the following filters and corrections. Latent and sensible heat and carbon dioxide fluxes were corrected with 2-D coordinate rotation. Although the primary objective of data collection at Stannard Rock was to quantify the evaporative flux, additional preliminary measurements of the carbon dioxide concentration and flux from the LI-7500 are also included in this dataset but it is advised to use the carbon data with caution. Carbon data reported in this dataset includes turbulent fluxes of CO2 with no storage correction (FC, µmol m-2 s-1) and CO2 density in mole fraction of wet air (CO2), which was originally output on the datalogger as average CO2 density (mg m-2 s-1) and converted into µmol mol-1 using air temperature and pressure in post-processing. Webb, Pearman, and Leuning terms were applied to account for density fluctuations for water vapor and CO2. Sonic path length, high-frequency attenuation and sensor separation were accounted for according to Horst and Massman, and the oxygen absorption correction for the KH2O hygrometer was also applied. Latent and sensible heat fluxes were assumed to be unrealistic above an absolute value of 1000 W m-2 and were removed. Both carbon flux (FC) and carbon dioxide mole fraction in wet air (CO2) and were assumed to be unrealistic above 1000 µmol m-2 s-1 and 1000 µmol mol-1 respectively. Spikes in latent and sensible heat and carbon fluxes and densities (often due to periods of precipitation) were identified by computing the mean and standard deviation over a moving, overlapping window of 336 half-hours (7 days), similar to Shao et al., and were removed when the flux was more than 1.5 standard deviations from the moving window’s mean. While Vickers and Mahrt use a threshold of 3.5 standard deviations from the mean, a conservative value of 1.5 was chosen due to the noisy nature of over-lake data at this particular site. This process was repeated twice for latent and sensible heat, and carbon dioxide fluxes and densities and therefore it is possible that some real, realistic data was filtered out in this process. No detrending was performed. As per AmeriFlux standards, no friction velocity (USTAR, m s-1) filtering was performed.

Spence, Chris↗

AmeriFlux FLUXNET-1F US-GL1 Stannard Rock

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-GL1 Stannard Rock. This is the FLUXNET version of the carbon flux data for the site US-GL1 Stannard Rock produced by applying the standard ONEFlux (1F) software. Site Description - Stannard Rock is located 39 km from the nearest shore (Keweenaw Peninsula) in Lake Superior, 44 miles NNE of Marquette, Michigan, and 24 miles ESE of Manitou Island. The site is located on the historic Stannard Rock Lighthouse, which was completed in 1882. Eddy covariance instrumentation was installed in 2008 by a network of scientists from both US and Canada, eventually to be called the Great Lakes Evaporation Network (GLEN). The intent of GLEN has been to provide observations of over-lake meteorology and evaporation, improve forecasting of Great Lakes water levels, and support a wide variety of stakeholders, including the National Weather Service (NWS), Environment and Climate Change Canada, National Oceanic and Atmospheric Administration, U.S. Coast Guard, recreational boaters and commercial shipping, emergency management officials, and the Great Lakes research community. The eddy covariance station along with other ancillary meteorological instrumentation is located at an approximate elevation of 39.2 meters above mean lake water level. Meteorological data from the lighthouse are sent to the National Data Buoy Center, where they can be viewed in real-time at http://www.ndbc.noaa.gov/station_page.php?station=stdm4 Uncorrected half-hour fluxes were computed directly on the logger using a 30-minute block averaging period as high-frequency data were not available. The half hour flux measurements downloaded from the datalogger were post-processed with the following filters and corrections. Latent and sensible heat and carbon dioxide fluxes were corrected with 2-D coordinate rotation. Although the primary objective of data collection at Stannard Rock was to quantify the evaporative flux, additional preliminary measurements of the carbon dioxide concentration and flux from the LI-7500 are also included in this dataset but it is advised to use the carbon data with caution. Carbon data reported in this dataset includes turbulent fluxes of CO2 with no storage correction (FC, µmol m-2 s-1) and CO2 density in mole fraction of wet air (CO2), which was originally output on the datalogger as average CO2 density (mg m-2 s-1) and converted into µmol mol-1 using air temperature and pressure in post-processing. Webb, Pearman, and Leuning terms were applied to account for density fluctuations for water vapor and CO2. Sonic path length, high-frequency attenuation and sensor separation were accounted for according to Horst and Massman, and the oxygen absorption correction for the KH2O hygrometer was also applied. Latent and sensible heat fluxes were assumed to be unrealistic above an absolute value of 1000 W m-2 and were removed. Both carbon flux (FC) and carbon dioxide mole fraction in wet air (CO2) and were assumed to be unrealistic above 1000 µmol m-2 s-1 and 1000 µmol mol-1 respectively. Spikes in latent and sensible heat and carbon fluxes and densities (often due to periods of precipitation) were identified by computing the mean and standard deviation over a moving, overlapping window of 336 half-hours (7 days), similar to Shao et al., and were removed when the flux was more than 1.5 standard deviations from the moving window’s mean. While Vickers and Mahrt use a threshold of 3.5 standard deviations from the mean, a conservative value of 1.5 was chosen due to the noisy nature of over-lake data at this particular site. This process was repeated twice for latent and sensible heat, and carbon dioxide fluxes and densities and therefore it is possible that some real, realistic data was filtered out in this process. No detrending was performed. As per AmeriFlux standards, no friction velocity (USTAR, m s-1) filtering was performed.

Spence, Chris [Environment and Climate Change Cana↗

Creep Behavior of Friction Stir Processed Haynes 282

Haynes 282 is a nickel-based superalloy designed for use in hot sections of turbines for aircraft and power generation. In these applications, elevated temperature creep performance is critical. To that end, creep behavior of friction stir processed material was carried out to investigate the high-temperature performance of this alloy. Friction stir processing of Haynes 282 was successfully completed, and the processed region was found to be defect-free. Various mechanical property characterization approaches were carried out in post-heat treated condition. Transverse tensile samples repeatedly failed in the base metal indicating 100% joint efficiency. Creep property evaluation was completed at 760 °C and at various stress levels. The creep-rupture lifetime of the processed material was similar to the base metal. Detailed electron microscopy analysis of the failed sample was carried out to understand the microstructural evolution in various locations of the sample during creep.

creep↗

Sudden collapse of a pressure profile generated by off-axis heating in a linear magnetized plasma

Here, the features of an unexpected, large event that arises spontaneously during a basic heat transport experiment are presented. It consists of the sudden collapse of the radial plasma pressure profile, akin to disruption events observed in toroidal magnetic confinement devices. The experiment is performed on the Large Plasma Device at the University of California, Los Angeles (UCLA). It uses a LaB6 thermionic emitter of annular shape to induce off-axis heating of a cold, afterglow plasma, in a linear magnetic geometry. The temporal evolution consists of three regimes. During an early, quiescent period, classical heat transport along and across the magnetic field arises from Coulomb collisions. After significant pressure gradients develop, drift-Alfvén waves become unstable. Upon reaching large amplitude, they trigger avalanche events that flatten the outer part of the heated region, which, in turn, quenches the instability. Due to the sustained heating, the pressure profile rebuilds and the process repeats, leading to a relatively long, second regime that displays multiple avalanches, but suddenly, the annular pressure profile is observed to collapse. After this collapse, the system enters a third regime with large fluctuations. Before the collapse, a rapid, runaway heating environment arises whose time evolution exhibits a self-similar dependence on the applied voltage. The time evolution, morphology, and scaling of the collapse event are presented, and an examination is made of the underlying mechanisms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhanced condensation heat transfer using porous silica inverse opal coatings on copper tubes

Abstract Phase-change condensation is commonplace in nature and industry. Since the 1930s, it is well understood that vapor condenses in filmwise mode on clean metallic surfaces whereas it condenses by forming discrete droplets on surfaces coated with a promoter material. In both filmwise and dropwise modes, the condensate is removed when gravity overcomes pinning forces. In this work, we show rapid condensate transport through cracks that formed due to material shrinkage when a copper tube is coated with silica inverse opal structures. Importantly, the high hydraulic conductivity of the cracks promote axial condensate transport that is beneficial for condensation heat transfer. In our experiments, the cracks improved the heat transfer coefficient from ≈ 12 kW/m 2 K for laminar filmwise condensation on smooth clean copper tubes to ≈ 80 kW/m 2 K for inverse opal coated copper tubes; nearly a sevenfold increase from filmwise condensation and identical enhancement with state-of-the-art dropwise condensation. Furthermore, our results show that impregnating the porous structure with oil further improves the heat transfer coefficient by an additional 30% to ≈ 103 kW/m 2 K. Importantly, compared to the fast-degrading dropwise condensation, the inverse opal coated copper tubes maintained high heat transfer rates when the experiments were repeated > 20 times; each experiment lasting 3–4 h. In addition to the new coating approach, the insights gained from this work present a strategy to minimize oil depletion during condensation from lubricated surfaces.

Adera, Solomon↗

Collection, release, and detection of analytes with polymer composite sampling materials

A unique fiber core sampler composition, related systems, and techniques for designing, making, and using the same are described. The sampler is used to interface with existing field instrumentation, such as Ion Mobility Spectrometer (IMS) equipment. Desired sampler characteristics include its: stiffness/flexibility; thermal mass and conductivity; specific heat; trace substance collection/release dependability, sensitivity and repeatability; thickness; reusability; durability; stability for thermal cleaning; and the like. In one form the sampler has a glass fiber core with a thickness less than 0.3 millimeter that is coated with a polymer including one or more of: polymeric organofluorine, polyimide, polyamide, PolyBenzlmidazole (PBI), PolyDiMethylSiloxane (PDMS), sulfonated tetrafluoroethylene (PFSA) and Poly(2,6-diphenyl-p-phenylene Oxide) (PPPO). Multiple polymer coatings with the same or different polymer types may be included, core/substrate surface functionalization utilized, and/or the core/substrate may be at partially filled with thermally conductive particles.

Addleman, Raymond S.↗

Tempering kinetics during multilayer laser additive manufacturing of a ferritic steel

Grade 91 steel forms martensite during additive manufacturing and the extent of tempering of martensite significantly affects the mechanical properties of parts. Currently, there is a lack of quantitative understanding of the tempering kinetics for Grade 91 steel, and as a result, the effects of repeated thermal cycles on properties for different processing conditions cannot be determined. Here we evaluate the tempering kinetics by determining the constant terms in the Johnson Mehl Avrami kinetic equation from the tempering data available in the literature and the thermal cycles computed using a rigorously-tested heat and fluid flow model of multi-layer additive manufacturing. The raw tempering data are cleaned using a neural network to enhance accuracy. The lower layers experience repeating cycles of heating and cooling when the upper layers are added. As a result, the hardness is reduced owing to the tempering of martensite. In contrast, martensite formed in the upper layers is not tempered to the same extent and the hardness remains high. Therefore, the hardness of the part increases with the distance from the substrate. Variations in the heat input at different laser powers and scanning speeds significantly affect the extent of tempering. Finally, since the method used here can provide a quantitative understanding of the tempering of martensite and the spatial variation in hardness, it can be used to tailor the microstructure and hardness of heat treatable printed metallic parts.

36 MATERIALS SCIENCE↗

Laser heating and evaporation of a single droplet

The laser technology is being abundantly studied for controlled energy deposition for a range of applications in aerodynamic flow control, material processing, ignition, and combustion. The absorption of laser radiation by liquid droplets affects further propagation of laser in the atmosphere and causes bleaching of suspended droplets while the ignition and combustion characteristics in combustors are influenced by the evaporation rate of the sprayed fuel. In this work, we present a multi-dimensional mathematical model built on OpenFOAM for laser heating and evaporation of a single droplet in the diffusion dominated regime taking into account absorption of the laser radiation, evaporation process and vapor flow dynamics. The developed solver is validated against available experimental and numerical data for the ethanol and water droplet heating and evaporation. For continuous heating the peak temperature is established by the balance of cooling, evaporation and heating and results in high temperature for larger droplets. It has been shown that for heating by a single laser pulse the maximum temperature of droplets depends only on the peak intensity of the laser radiation. Furthermore, for the peak irradiance close to the transition to the boiling regime, temporal dynamics of the droplet temperature is independent of the droplet size. With proper normalization of time, the dynamics of the droplet shrinkage and cooling is shown to be independent of droplet sizes and peak laser intensities. The influence of cooling and evaporation processes on droplet heating was found to be controlled by the pulse repetition rate for repeated pulse operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

COVID-19 global pandemic planning: Performance and electret charge of N95 respirators after recommended decontamination methods

Shortages of N95 respirators for use by medical personnel have driven consideration of novel conservation strategies, including decontamination for reuse and extended use. Decontamination methods listed as promising by the Centers for Disease Control and Prevention (CDC) (vaporous hydrogen peroxide (VHP), wet heat, ultraviolet irradiation (UVI)) and several methods considered for low resource environments (bleach, isopropyl alcohol and detergent/soap) were studied for two commonly used surgical N95 respirators (3M™ 1860 and 1870+ Aura™). Although N95 filtration performance depends on the electrostatically charged electret filtration layer, the impact of decontamination on this layer is largely unexplored. As such, respirator performance following decontamination was assessed based on the fit, filtration efficiency, and pressure drop, along with the relationship between (1) surface charge of the electret layer, and (2) elastic properties of the straps. Decontamination with VHP, wet heat, UVI, and bleach did not degrade fit and filtration performance or electret charge. Isopropyl alcohol and soap significantly degraded fit, filtration performance, and electret charge. Pressure drop across the respirators was unchanged. Modest degradation of N95 strap elasticity was observed in mechanical fatigue testing, a model for repeated donnings and doffings. CDC recommended decontamination methods including VHP, wet heat, and UV light did not degrade N95 respirator fit or filtration performance in these tests. Extended use of N95 respirators may degrade strap elasticity, but a loss of face seal integrity should be apparent during user seal checks. NIOSH recommends performing user seal checks after every donning to detect loss of appropriate fit. Decontamination methods which degrade electret charge such as alcohols or detergents should not be used on N95 respirators. The loss of N95 performance due to electret degradation would not be apparent to a respirator user or evident during a negative pressure user seal check.

60 APPLIED LIFE SCIENCES↗

Morphological Transitions of a Photoswitchable Aramid Amphiphile Nanostructure

Self-assembly of small amphiphilic molecules in water can lead to nanostructures of varying geometries with pristine internal molecular organization. Here we introduce a photoswitchable aramid amphiphile (AA), designed to exhibit extensive hydrogen bonding and robust mechanical properties upon self-assembly, while containing a vinylnitrile group for photoinduced cis-trans isomerization. We demonstrate spontaneous self-assembly of the vinylnitrile-containing AA in water to form nanoribbons. Upon UV irradiation, trans-to-cis isomerizations occur concomitantly with a morphological transition from nanoribbons to nanotubes. The nanotube structure persists in water for over six months, stabilized by strong and collective intermolecular interactions. We demonstrate that the nanoribbon-to-nanotube transition is reversible upon heating and that switching between states can be achieved repeatedly. Finally, we use electron microscopy to capture the transition and propose mechanisms for nanoribbon-to-nanotube rearrangement and vice versa. This stability and switchability of photoresponsive AA nanostructures make them viable for a range of future applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Falling particle impact erosion testing for particle based CSP systems

CSP systems are currently being examined as an effective method for using solar energy to generate electricity. While much of this research has been conducted using molten salt as the heat transfer medium, in recent years, solid particles have been posited as a cheaper and more energy efficient heat transfer medium for use in CSP systems. Many researchers have looked into the effectiveness of solid particles as a heat transfer medium. However, a concern with the use of particles is that the falling particles will impact various components within the CSP system, such as the hopper, the heat exchanger, and the insulating material, resulting in surface erosion and damage. With repeated impacts from falling particles, material from the surfaces under impact is removed. The degree of erosion depends on whether the substrate is made of brittle or ductile material. Furthermore, factors such as particle shape, size, hardness, concentration, impact angle, particle velocity, and substrate hardness will contribute to the erosion process and determine how much and how quickly erosion will takes place in a system. Three types of erosion will be observed simultaneously: impact erosion from particle impact on receiver, particle storage, and heat exchanger walls, abrasion erosion from particle sliding motion along walls, and attrition erosion as the particles breakdown from particle-to-particle contact and particle-to-wall interactions. It is imperative to understand each of these erosions individually for a more comprehensive understanding and prediction of CSP system durability. In this work, we developed an experimental test setup capable of measuring impact erosion at conditions relevant to 1MW CSP plant. Subsequently, Impact erosion measurements were performed for three different candidate substrate materials at low particle velocities using HSP 40/70 ceramic particles.

14 SOLAR ENERGY↗