Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEAT EFFECT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A diagnostic study of the forcing of the Ferrel cell by eddies, with latent heat effects included

A diagnostic study of the forcing of the Ferrel cell by eddy fluxes in the Northern Hemisphere is carried out. The quasi-geostrophic omega equation, and Oort and Rasmusson's (1971) data set, are used. The effects of condensation associated with the large scale motions are introduced to the omega equation by using the quasi-geostrophic moisture conservation equation. Thus, the dry static stability is replaced by a moist static stability, and the forcing of the Ferrel cell by eddy latent heat fluxes as well as sensible heat and momentum fluxes is included. Both effects tend to enhance the forcing of the Ferrel cell. The numerical analysis indicates that the effects are small in January, but in July the maximum vertical velocities are enhanced by about 30 percent.

Salustri, G.↗

Global and local Joule heating effects seen by DE 2

In the altitude region between 350 and 550 km, variations in the ion temperature principally reflect similar variations in the local frictional heating produced by a velocity difference between the ions and the neutrals. Here, the distribution of the ion temperature in this altitude region is shown, and its attributes in relation to previous work on local Joule heating rates are discussed. In addition to the ion temperature, instrumentation on the DE 2 satellite also provides a measure of the ion velocity vector representative of the total electric field. From this information, the local Joule heating rate is derived. From an estimate of the height-integrated Pedersen conductivity it is also possible to estimate the global (height-integrated) Joule heating rate. Here, the differences and relationships between these various parameters are described.

Heelis, R. A.↗

Shock Heating: Effects on Chondritic Material

At the 1994 Conference on Chondrules and the Protoplanetary Disk, shock waves were discussed as mechanisms that may have been responsible for forming chondrules, millimeter-sized igneous spheres which are significant components of chondritic meteorites, and references therein]. At the time, shock waves were appealing because they were thought to be brief, repetitive events that were quantitatively shown to be able to rapidly heat silicates to the appropriate temperatures for chondrule formation. Since that meeting, more detailed models for the thermal processing of material in shock waves have been developed. These models have tracked the thermal evolution of the silicates for longer periods of time and found that their cooling rates are also consistent with what has been inferred for chondrules. In addition to the thermal histories of these particles, shock waves may be able to explain a number of other features observed in primitive meteorites. Here, we review the recent work that has been done in studying the interaction of solids with shock waves in the solar nebula.

Desch, S. J.↗

On Orbit Daytime Solar Heating Effects: A Comparison of Ground Chamber Arcing Results

The purpose of the current experiment is to make direct comparisons between the arcing results obtained from the diffusion pumped vertical chamber and our newly renovated Teney vacuum chamber which is equipped with a cryogenic pump. Recall that the prior reported results obtained for the Vertical chamber were nominal at best, showing only a slight reduction in the arc rate after 5 heating cycles at the lower bias potentials and virtually no changes at high potential biases. It was concluded that the vertical chamber was unable to remove enough water vapor from the chamber to adequately test the arcing criterion. Because the cryo-pumped Teney chamber has a ten times better pumping speed, (40,000 liters per sec compared to 4,000 liters per sec for the diffusion pumped vertical chamber), a decision was made to retest that experiment in both the Teney and Vertical vacuum chambers. A comparison of the various data is presented with encouraging results.

Galofaro, J.↗

On-Orbit Daytime Solar Heating Effects: A Comparison of Ground Chamber Arcing Results

The purpose of the current experiment is to make direct comparisons between the arcing results obtained from the diffusion pumped vertical chamber and our newly renovated Teney vacuum chamber which is equipped with a cryogenic pump. Recall that the prior reported results obtained for the Vertical chamber were nominal at best, showing only a slight reduction in the arc rate after five heating cycles at the lower bias potentials and virtually no changes at high potential biases. It was concluded that the vertical chamber was unable to remove enough water vapor from the chamber to adequately test the arcing criterion. Because the cryo-pumped Teney chamber has a ten times better pumping speed, (40,000 liters per sec compared to 4,000 liters per sec for the diffusion pumped vertical chamber), a decision was made to retest that experiment in both the Teney and Vertical vacuum chambers. A comparison of the various data is presented with encouraging results.

Galofaro, J.↗

Ignition propagation and heat effects of propellant chips embedded in castable inhibitor using a laser flux test bomb

A castable inhibitor is applied to the aft face of the Space Shuttle Redesigned Solid Rocket Motor (RSRM) forward segment propellant grain to control propellant surface burn area. During fabrication, the propellant surface is trimmed prior to the inhibitor application. This produces a potential for small propellant chips to remain undetected on the propellant surface and contaminate the inhibitor during application. The concern was that undetected propellant chips in the inhibitor might provide a fuse path for premature propellant ignition underneath the inhibitor. To evaluate the fuse path potential, testing was performed on inhibitor samples with embedded propellant. The internal motor environment was simulated with a calibrated CO2 laser beam directed onto a sample which was placed in a 4100 kPa (600 psi) nitrogen pressurized bomb (laser bomb). The testing showed definitive results pertaining to fuse path formation. Embedded propellant chips did not autoignite until the receding heat affected inhibitor surface reached, or passed, the propellant chip. Samples with embedded propellant chips in alignment did not propagate ignition from one chip to another with separation distances as small as 0.010 cm(0.004 inc) and some as little as 0.0051 cm (0.002 in). Propellant chips with volumes approximately less than 0.025 cu cm (0.0015 cu in) (which did not propagate ignition) did not increase the inhibitor material decomposition depth more than the resulting void cavity of the burned out propellant chip. In addition, the depth of this void cavity did not increase until it was overtaken by the surrounding material decomposition depth. This was due, in part, to the retention of the protective inhibitor char layer. Samples with embedded propellant strings, whose thicknesses were below 0.023 cm (0.009 in), did not propagate ignition. Propellant string thicknesses above 0.038 cm (0.015 in) did propagate ignition. Test sample char and heat affected layer measurements and observations compared well with those from the Space Shuttle Solid Rocket Motor (SRM) Technical Evaluation Motor no. 9(TEM-9).

Bolton, Douglas E., Jr.↗

Compressibility and Heating Effects on Pressure Loss and Cooling of a Baffled Cylinder Barrel

Theoretical investigations have shown that, because air is compressible, the pressure-drop requirements for cooling an air-cooled engine will be much greater at high altitudes and high speeds than at sea level and low speeds. Tests were conducted by the NACA to obtain some experimental confirmation of the effect of air compressibility on cooling and pressure loss of a baffled cylinder barrel and to evaluate various methods of analysis. The results reported in the present paper are regarded as preliminary to tests on single-cylinder and multicylinder engines. Tests were conducted over a wide range of air flows and density altitudes.

Goldstein, Arthur W↗

Comparison of Theoretical and Experimental Values for the Effective Heat of Ablation of Ammonium Chloride

Thermodynamic properties of ammonium chloride have been obtained and applied to a theoretical analysis of the shielding mechanism which reduces the rate of heat transfer to a body when ablation takes place at the surface. The analysis has considered the mechanism as one in which the material sublimes directly from the solid to the vapor phase. The results of the computation are compared with the experimental results obtained from the Langley 700-kilowatt arc jet.

Welker, Jean E.↗

Compressibility and Heating Effects on Pressure Loss and Cooling of a Baffled Cylinder Barrel

Theoretical investigations have shown that, because air is compressible, the pressure-drop requirements for cooling an air-cooled engine will be much greater at high altitudes and high speeds than at sea level and low speeds. Tests were conducted by the NACA to obtain some experimental confirmation of the effect of air compressibility on cooling and pressure loss of a baffled cylinder barrel and to evaluate various methods of analysis. The results reported in the present paper are regarded as preliminary to tests on single-cylinder and multi-cylinder engines. Tests were conducted over a wide range of air flows and density altitudes.

Goldstein, Arthur W.↗

Heat Effects of Promoters and Determination of Burn Criterion in Promoted Combustion Testing

Promoted ignition testing (NASA Test 17) [1] is used to determine the relative flammability of metal rods in oxygen-enriched atmospheres. A promoter is used to ignite a metal sample rod, initiating sample burning. If a predetermined length of the sample burns, beyond the promoter, the material is considered flammable at the condition tested. Historically, this burn length has been somewhat arbitrary. Experiments were performed to better understand this test by obtaining insight into the effect a burning promoter has on the preheating of a test sample. Test samples of several metallic materials were prepared and coupled to fast-responding thermocouples along their length. Thermocouple measurements and test video were synchronized to determine temperature increase with respect to time and length along each test sample. A recommended flammability burn length, based on a sample preheat of 500 F, was determined based on the preheated zone measured from these tests. This length was determined to be 30 mm (1.18 in.). Validation of this length and its rationale are presented.

Sparks, Kyle M.↗