Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Grid-forming inverter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

418 records · Page 2

A Study of the Aligned-Grid Retarding Potential Analyzer for Electric Propulsion Applications

During the development of energy analyzers for NASA’s Solar Electric Propulsion Plasma Diagnostics Package, detailed studies were performed to compare the benefits and drawbacks of different types of gridded potential analyzers. In particular, modeling and testing were performed on three types of retarding potential analyzer with aligned grids, and one type with unaligned grids. Additionally, a type of gridded energy analyzer was tested. Analyses of the model and test results showed that manufacturing an analyzer with aligned grids required greater precision and knowledge than other analyzers. A properly designed analyzer with aligned grids exhibited superior signal level, acceptance angle control, energy resolution, and compactness compared to an analyzer with unaligned grids. Additionally, the gridded energy analyzer was found to accept a broad range of incidence angles while having superior signal, energy resolution, and compactness compared to retarding potential analyzer with unaligned grid. This article describes the basic design principles deployed in the study, the associated modeling work, and the characterization tests that were performed. The article summarizes the benefits and drawbacks associated with each type of energy analyzer tested.

Electric Propulsion

UL 1741SC Conformance Development, Evaluation, and Proposal [Slides]

V2G AC is a type of grid interconnection by mobile battery that transforms an EV into a DER with the potential to stabilize the grid and lower costs for electricity. UL 1741SC is a critical new standard to enable grid interconnection of V2G AC-capable vehicles, by defining requirements for V2G AC-intended EVSEs as a gatekeeper between the grid and the EV to support grid safety, such as through redundant voltage trip (namely oversight). EVSE manufacturers need a clear set of conformance test cases and criteria by which to evaluate their equipment and confirm the compliance with UL 1741SC, so that the EVSEs performs as intended for the grid safety. Hence, NLR identified necessary conformance tests and performed the tests identified to understand the maturity.

29 ENERGY PLANNING, POLICY, AND ECONOMY

Charge-exchange erosion studies of accelerator grids in ion thrusters

A particle simulation model is developed to study the charge-exchange grid erosion in ion thrusters for both ground-based and space-based operations. Because the neutral gas downstream from the accelerator grid is different for space and ground operation conditions, the charge-exchange erosion processes are also different. Based on an assumption of now electric potential hill downstream from the ion thruster, the calculations show that the accelerator grid erosion rate for space-based operating conditions should be significantly less than experimentally observed erosion rates from the ground-based tests conducted at NASA Lewis Research Center (LeRC) and NASA Jet Propulsion Laboratory (JPL). To resolve this erosion issue completely, we believe that it is necessary to accurately measure the entire electric potential field downstream from the thruster.

Xiaohang Peng

Power Lane County Electric Grid Handbook

In 2024, Lane Couty was selected to participate in the U.S. Department of Energy’s Energy to Community program. Through the program, National Laboratory researchers from Lawrence Berkeley National Laboratory, Pacific Northwest National Laboratory, and the National Laboratory of the Rockies provide three years of technical assistance to Lane County and their project partners: the Center for Rural Livelihoods, Springfield Utility Board, and Emerald People’s Utility District. The project, named Power Lane County, aims to improve local electric system affordability, reliability and resilience in the face of natural hazards and potentially rising loads. The Power Lane County Electric Grid Handbook establishes a foundational understanding of the energy landscape and electric grid in Lane County to inform community engagement, education, and analysis in future project phases. This document synthesizes public data and utility and stakeholder engagement, including utility interviews to give the reader a comprehensive view of the challenges facing Lane County's electric system and the opportunities to address them

Electricity

Electricity Markets and Long-Duration Energy Storage: A Survey of Grid Services and Revenue Streams

Purpose of Review Long Duration Energy Storage (LDES) is increasingly viewed as a potential resource for providing grid services that enhance the stability and flexibility of electricity systems. While some LDES services are integrated into existing market frameworks, traditional mechanisms may not fully account for their operational characteristics, potentially leading to undervaluation. Within this context, this paper reviews the literature and industry practices to assess potential grid services for LDES, evaluates existing compensation mechanisms, and identifies challenges to full market integration. Recent Findings We first review existing literature and identify key grid services unique to LDES, including enhancing grid resilience during extreme weather events, enabling long-term energy shifting, and providing flexible and firm energy in systems with limited dispatchable resources. Here, we also review how LDES services are compensated in current market frameworks and the challenges associated with the full realization of LDES values. Additionally, we summarize market mechanisms for storage technologies across U.S. wholesale markets. We find that some markets are adjusting incentive structures, such as incorporating storage duration in capacity accreditation, to better align with system needs and LDES contributions to the grid. However, further refinements in capacity remuneration and dispatch timeframes may be needed for more effective realization of LDES value. Summary This review evaluates potential grid services for LDES, examines existing compensation mechanisms for LDES technologies, and identifies gaps between these mechanisms and LDES operational characteristics. The review concludes by outlining potential market enhancements for more effective LDES integration and articulating additional research needs to support its efficient participation in future power systems.

Flexible resources

Resilience Strategies to Ensure Water Supply Continuity During Extended Grid Outages

The towns of Edgartown, Oak Bluffs and Tisbury, on the island of Martha’s Vineyard, MA, are concerned about the effect of prolonged grid outages on continuity of their water supply. Water pumping stations operated by the water utilities that currently serve each of the towns currently have backup power generation that can support water delivery for up to one week during peak water demand periods. Sandia advised on options to extend water supply to two weeks.

Mammoli, Andrea Alberto [Sandia National Laborator

Integration and Optimization of Loads, and Renewables for Grid-Interactive Efficient Buildings

Deploying advanced building control strategies in small- and medium-sized commercial buildings (SMBs) is critical but constrained by two major challenges: (1) the lack of sensor and control infrastructure (SCI) and (2) the significant engineering effort required for implementation and configuration. While these barriers limit large-scale adoption in SMBs, they remain underexplored in the literature, which has largely emphasized feasibility over scalability.

25 ENERGY STORAGE

Are CO2 batteries ready for the grid? A cross-cutting deployment checklist

Metal-CO2 batteries have attracted considerable research interest in the past decade due to the utilization of the greenhouse CO2 gas. The low cost and abundance of CO2 feedstocks, together with high specific capacity metal anodes, make this technology a promising candidate for electricity-demanding data centers and grids. However, nonstandard data reporting, ambiguous hardware designs, and questionable cycling parameters have emerged as the field has grown. A clear checklist and standardized reporting format for research and development are urgently needed. Here, after carefully re-analyzing 15 Na-CO2 and 9 Li-CO2 studies, we propose a general checklist and a flowchart for CO2 batteries and related gas conversion systems. Specific performance values from a deployment-oriented perspective, based on commercial lithium iron phosphate batteries, are integrated into the list. We frame research and development efforts around grid-relevant outputs, including areal rate and capacity, cyclability, gas utilization, and safety. While illustrated for Na- and Li-CO2 cells, this framework is directly transferable to other CO2 batteries and air/oxygen batteries, helping align benchtop demonstrations with systematic metrics that ultimately govern future deployment.

Wu, Wenda [ORNL] (ORCID:000900033307687X)

Vidyut3d: A Gpu Accelerated Fluid Solver for Non-Equilibrium Plasmas on Adaptive Grids

We present the numerical methods, programming methodology, verification, and performance assessment of a non-equilibrium plasma fluid solver that can effectively utilize current and upcoming central processing and graphics processing unit (CPU+GPU) architectures, in this work. Our plasma fluid model solves the coupled conservation equations for species transport, electrostatic Poisson and electron temperature on adaptive Cartesian grids. Our solver is written using performance portable adaptive-grid/particle management library, AMReX, and is portable over widely available vendor specific GPU architectures. We present verification of our solver using method of manufactured solutions that indicate formal second order accuracy with central diffusion and fifth-order weighted-essentially-non-oscillatory (WENO) advection scheme. We also verify our solver with published literature on capacitive discharges and atmospheric pressure streamer propagation. We demonstrate the use of our solver on two 3D simulation cases: an atmospheric streamer propagation in Ar-H2 mixtures and a low pressure twin electrode radio frequency reactor. Our performance studies on three different CPU+GPU architectures indicate approximately 150-400X speed-up using AMD and NVIDIA GPUs per time step compared to a single CPU core for a 4 million cell simulation with 15 species.

Sitaraman, Hariswaran

Adsorptive behavior of poly (vinylidene fluoride) membranes for the recovery of lignin-derived hydrophobic deep eutectic solvents

Abstract Recently, membrane technology has gained significant traction as an energy-efficient alternative to traditional thermal processes for solvent recovery. Deep eutectic solvents (DESs) have emerged as sustainable alternatives to conventional organic solvents, yet a systematic methodology for selecting compatible membrane materials for their recovery remains underdeveloped. This study established a predictive framework for membrane material selection in hydrophobic DES applications using Hansen Solubility Parameters (HSP) with inverted criteria targeting materials with relative energy difference (RED) values greater than 1.0. Flat sheet membranes were fabricated via the non-solvent induced phase separation (NIPS) technique. Four NIPS fabricated polymer membranes were evaluated: polysulfone, cellulose acetate, polyvinylidene fluoride (PVDF) fabricated with polyethylene glycol (PEG) as a pore-forming agent, and polybenzimidazole (PBI). The HSP approach successfully predicted membrane-solvent compatibility, with polysulfone (RED = 0.6) and cellulose acetate (RED = 0.9) dissolving completely within 24 h, while PVDF (RED = 1.9) and PBI (RED = 1.1) maintained structural integrity throughout a 7-day exposure period. Furthermore, PVDF demonstrated superior performance with minimal weight gain (3.0%), hydrophobic surface characteristics (122° water contact angle), and enhanced mechanical properties following DES exposure. Comprehensive chemical and morphological characterization confirmed PVDF’s chemical stability and revealed a surface-selective interaction mechanism involving simultaneous PEG (pore-forming agent) extraction and DES component adsorption. Adsorption kinetics followed pseudo-first-order behavior with reversible characteristics, best described by the Temkin isotherm model (R² = 0.9987). PVDF membranes-maintained separation functionality with average lignin rejection (75.2 ± 7.69%) and demonstrated filtration permeability of 2.0 ± 0.34 LMH/bar. This methodology provides a rational approach for membrane selection in emerging solvent systems, contributing to the advancement of sustainable separation technologies for DES-based biomass processing applications.

Science & Technology - Other Topics

An Overview of Electric Vehicle Load Modeling Strategies for Grid Integration Studies

The adoption of electric vehicles (EVs) has emerged as a solution to reduce greenhouse gas emissions in the transportation sector, which has motivated the implementation of public policies to promote their use in several countries. However, the high adoption of EVs poses challenges for the electricity sector, as it would imply an increase in energy demand and possible impacts on the power quality (PQ) of the power grid. Therefore, it is important to conduct EV integration studies in the power grid to determine the amount that can be incorporated without causing problems and identify the areas of the power sector that will require reinforcements. Accurate EV load patterns are required for this type of study that, through mathematical modeling, reflect both the dynamic behavior and the factors that influence the decision to recharge EVs. This article aims to present an overview of EVs, examine the different factors considered in the literature for modeling EV load patterns, and review modeling methods. EV load modeling methods are classified into deterministic, statistical, and machine learning. The article shows that each modeling method has its advantages, disadvantages, and data requirements, ranging from simple load modeling to more accurate models requiring large datasets.

Computer Science

Lithium-Ion Battery Design for Grid-Scale Energy Storage App

A software that delivers parameters from energy storage system (ESS) to container, rack, module and single cell design, as well as data analysis on arbitrage energy and frequency regulation of ESS in different regions, has been developed. The Lithium-ion Battery Design for Grid-scale Energy Storage App V1.0 has the capability to output the system, module and cell design with the energy, power, capacity, group method, cost of single cell, and single cell test protocol which break down from input energy storage system data in different regions. The default chemistry of the battery is LiFePO4 and graphite. The energy density of the graphite/LiFePO 4 pouch cell ranges from 100 Wh/kg to 200 Wh/Kg in the software. Graphite/LiFePO 4 pouch cell (up to 1Ah in lab) manufacturing line is also built and can be used to evaluate the test protocol, moreover, for electrolyte evaluation in other ESMI seedling projects. The software enables rapid prototyping to accelerate energy storage research, development, and manufacturing.

Liu, Dianying [Pacific Northwest National Laborato

Integrating AI Data Centers with the Power Grid

The rapid expansion of artificial intelligence (AI) has triggered an unprecedented surge in electricity demand, with US data center energy use projected to double or triple 2023 levels by 2028. This exponential growth places strain on grid infrastructure, which can hinder timely construction of desired computing capacity. To bridge this supply-demand gap, utilities and AI developers are increasingly turning to demand flexibility, a strategy that incentivizes shifting or reducing power use during peak periods of grid stress. Data centers are uniquely equipped for flexible operations due to their digital workloads, built-in redundancy, and onsite energy assets. This article outlines four primary mechanisms to enable data center flexibility: computational load flexibility (shifting tasks temporally or geographically), flexible use of core facility infrastructure adjustments, energy storage utilization, and onsite electricity generation. To encourage adoption, utilities are deploying new tariff designs, including voluntary interruptible service riders, mandated flexibility requirements, and streamlined interconnection processes for flexible loads. For the highly capitalized and rapidly growing AI industry, the primary motivators for embracing these strategies are expediting facility interconnection, satisfying emerging regulatory mandates, and mitigating community resistance. While demand flexibility cannot substitute the long-term need for new bulk power generation, it serves as an essential, immediate solution for enabling near-term deployment. By transforming data centers from grid stressors into stabilizing assets, flexible operations can ensure reliable grid integration, ease market pressures, and support a resilient power system.

24 POWER TRANSMISSION AND DISTRIBUTION

POWER ELECTRONICS GRID TIED SYSTEM FINAL REPORT

Across the country, electric utilities are grappling with the persistent hurdles of integrating Distributed Energy Resources (DERs). Managing these assets safely and effectively is a complex endeavor, complicated by varying ownership structures, management philosophies, and the diversity of the technologies themselves. Consequently, the industry has seen a proliferation of bespoke system designs, control strategies, and communication frameworks—forcing utilities to spend significant time and resources developing one-off integration solutions. This project addressed these integration hurdles through a scalable demonstration of intelligent devices designed to coordinate and control diverse resources in low-voltage applications. This concept minimized the need for complex integration by transforming the separate DERs into a dispatchable virtual power plant (VPP) with integrated resiliency functions (called a Node). By collaborating with a utility partner, the project focused on developing rapidly implementable use cases that bridged the gap between theoretical control and real-world deployment

99 GENERAL AND MISCELLANEOUS