Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Benchmark Case for the Grid Survivability Analysis

Among current priorities of the power system analysis is the development of metrics and computational tools for the resilience analysis during catastrophic events. New methods and tools are required for such an analysis and they have to be validated prior application to real systems. However, benchmark problems are not readily available due to the analysis novelty. The current paper presents a case based on the IEEE 14-bus system for this purpose. The grid is simplified to a graph with nodes representing generators, loads, and buses. Power inputs are imported from real-time simulations of the IEEE 14-bus system. Outcomes of all possible combinations of failed elements are presented in terms of probabilities for the grid to survive, partially survive, or fail. Only the power grid's ability to withstand adverse events (survivability) is analyzed. The grid's recoverability, the other part of the resilience analysis, is not considered.

power system↗

Behavior Computation for Smart Grid Software Analysis

Smart grid embedded software is subject to intrusion and compromise with potentially serious consequences. Current methods of cybersecurity analysis are increasingly challenged by the scope the problem. Oak Ridge National Laboratory (ORNL) is pioneering the new technology of software behavior computation to help address these risks. Software behavior computation and its instantiation in Function eXtraction (FX) systems apply mathematical foundations of denotational semantics to compute the behavior of software in all circumstances of use. Research has shown how to make the effects of recursion-theoretic limitations on this process arbitrarily small. Behavior computation operates on the functional semantics of programs, and is not subject to the limitations of syntactic recognition or testing. ORNL is applying FX technology to help evaluate cyber security properties in smart grid systems, with initial focus on vulnerabilities in embedded software that controls smart meters.

denotational semantics↗

Grid Impact Analysis of Heavy-Duty Electric Vehicle Charging Stations

This paper presents a grid impact analysis of heavy-duty electric vehicle (EV) charging stations. In this work, heavy-duty EVs have battery capacities high enough to provide a range of 250-500 miles on a single charge, such as long-haul trucks. Heavy-duty EVs will require extremely fast charging rates to reduce charging time and will induce very high charging loads (at the multiple-megawatt scale) if several vehicles charge at the same time. Therefore, analysis is needed to understand the impact of charging station loads on the electric power grid and set the baseline for developing mitigation plans and necessary system upgrades. We develop a systematic procedure to analyze the potential impact of the placement of charging stations on the grid. Charging load is modeled using a DC fast-charging station model. A voltage load sensitivity matrix approach is leveraged to investigate the challenges of placing charging stations on the feeder. Given the charging load profiles and suggested charging station locations, time-series simulations are performed on various connection points on the feeder to understand the impact. The analysis is performed on both the IEEE 34-bus system and a realistic feeder from California. Initial mitigation solutions are developed based on insights from this analysis.

47 OTHER INSTRUMENTATION↗

Forced Oscillation Grid Vulnerability Analysis and Mitigation Using Inverter-Based Resources: Texas Grid Case Study

Forced oscillation events have become a challenging problem with the increasing penetration of renewable and other inverter-based resources (IBRs), especially when the forced oscillation frequency coincides with the dominant natural oscillation frequency. A severe forced oscillation event can deteriorate power system dynamic stability, damage equipment, and limit power transfer capability. This paper proposes a two-dimension scanning forced oscillation grid vulnerability analysis method to identify areas/zones in the system that are critical to forced oscillation. These critical areas/zones can be further considered as effective actuator locations for the deployment of forced oscillation damping controllers. Additionally, active power modulation control through IBRs is also proposed to reduce the forced oscillation impact on the entire grid. The proposed methods are demonstrated through a case study on a synthetic Texas power system model. The simulation results demonstrate that the critical areas/zones of forced oscillation are related to the areas that highly participate in the natural oscillations and the proposed oscillation damping controller through IBRs can effectively reduce the forced oscillation impact in the entire system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation of Grid Modification Methods for On- and Off-Track Sonic Boom Analysis

Grid modification methods have been under development at NASA to enable better predictions of low boom pressure signatures from supersonic aircraft. As part of this effort, two new codes, Stretched and Sheared Grid - Modified (SSG) and Boom Grid (BG), have been developed in the past year. The CFD results from these codes have been compared with ones from the earlier grid modification codes Stretched and Sheared Grid (SSGRID) and Mach Cone Aligned Prism (MCAP) and also with the available experimental results. NASA's unstructured grid suite of software TetrUSS and the automatic sourcing code AUTOSRC were used for base grid generation and flow solutions. The BG method has been evaluated on three wind tunnel models. Pressure signatures have been obtained up to two body lengths below a Gulfstream aircraft wind tunnel model. Good agreement with the wind tunnel results have been obtained for both on-track and off-track (up to 53 degrees) cases. On-track pressure signatures up to ten body lengths below a Straight Line Segmented Leading Edge (SLSLE) wind tunnel model have been extracted. Good agreement with the wind tunnel results have been obtained. Pressure signatures have been obtained at 1.5 body lengths below a Lockheed Martin aircraft wind tunnel model. Good agreement with the wind tunnel results have been obtained for both on-track and off-track (up to 40 degrees) cases. Grid sensitivity studies have been carried out to investigate any grid size related issues. Methods have been evaluated for fully turbulent, mixed laminar/turbulent and fully laminar flow conditions.

Nayani, Sudheer N.↗

Visual Analytics for Power Grid Contingency Analysis

Contingency analysis is the process of employing different measures to model scenarios, analyze them, and then derive the best response to remove the threats. This application paper focuses on a class of contingency analysis problems found in the power grid management system. A power grid is a geographically distributed interconnected transmission network that transmits and delivers electricity from generators to end users. The power grid contingency analysis problem is increasingly important because of both the growing size of the underlying raw data that need to be analyzed and the urgency to deliver working solutions in an aggressive timeframe. Failure to do so may bring significant financial, economic, and security impacts to all parties involved and the society at large. The paper presents a scalable visual analytics pipeline that transforms about 100 million contingency scenarios to a manageable size and form for grid operators to examine different scenarios and come up with preventive or mitigation strategies to address the problems in a predictive and timely manner. Great attention is given to the computational scalability, information scalability, visual scalability, and display scalability issues surrounding the data analytics pipeline. Most of the large-scale computation requirements of our work are conducted on a Cray XMT multi-threaded parallel computer. The paper demonstrates a number of examples using western North American power grid models and data.

contingency analysis↗

Machine Committee Framework for Power Grid Disturbances Analysis Using Synchrophasors Data

Events detection is a key challenge in power grid frequency disturbances analysis. Accurate detection of events is crucial for situational awareness of the power system. In this paper, we study the problem of events detection in power grid frequency disturbance analysis using synchrophasors data streams. Current events detection approaches for power grid rely on individual detection algorithm. This study integrates some of the existing detection algorithms using the concept of machine committee to develop improved detection approaches for grid disturbance analysis. Specifically, we propose two algorithms—an Event Detection Machine Committee (EDMC) algorithm and a Change-Point Detection Machine Committee (CPDMC) algorithm. Both algorithms use parallel architecture to fuse detection knowledge of its individual methods to arrive at an overall output. The EDMC algorithm combines five individual event detection methods, while the CPDMC algorithm combines two change-point detection methods. Each method performs the detection task separately. The overall output of each algorithm is then computed using a voting strategy. The proposed algorithms are evaluated using three case studies of actual power grid disturbances. Compared with the individual results of the various detection methods, we found that the EDMC algorithm is a better fit for analyzing synchrophasors data; it improves the detection accuracy; and it is suitable for practical scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Graphically Interactive Approach to Structured and Unstructured Surface Grid Quality Analysis

A graphically interactive approach to structured and unstructured surface grid quality analysis is described. A Surface Analysis Code SurfACe) is developed to help a user analyze surface grid quality based on surface normal vectors, first and second derivatives of these vectors, normal, Gaussian, and mean curvatures, orthogonality, aspect ratio, and cell area. The results demonstrate how this approach can be used to reduce surface grid generation errors and increase the cost effectiveness of Computational Fluid Dynamics as an aircraft design tool.

Stewart, John E.↗

Probabilistic Grid Reliability Analysis with Energy Storage Systems

SAND2025-12025O The Probabilistic Grid Reliability Analysis with Energy Storage Systems (ProGRESS) software tool is an open-source tool for assessing the resource adequacy of the evolving electric power grid integrated with energy storage systems (ESS). This tool uses a simulation engine to create diverse scenarios that test the limits of the modern power grid consisting of a high-volume ESS and variable energy resources (VER). Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Nguyen, Tu↗

Dynamic Wireless Power Transfer - Grid Impacts Analysis

This presentation discusses the current status of analysis of the electricity grid impacts of a dynamic wireless power transfer system deployed to the Atlanta region on select high traffic roadway segments.

33 ADVANCED PROPULSION SYSTEMS↗

Grid Stiffened Structure Analysis Tool

The Grid Stiffened Analysis Tool contract is contract performed by Boeing under NASA purchase order H30249D. The contract calls for a "best effort" study comprised of two tasks: (1) Create documentation for a composite grid-stiffened structure analysis tool, in the form of a Microsoft EXCEL spread sheet, that was developed by originally at Stanford University and later further developed by the Air Force, and (2) Write a program that functions as a NASTRAN pre-processor to generate an FEM code for grid-stiffened structure. In performing this contract, Task 1 was given higher priority because it enables NASA to make efficient use of a unique tool they already have; Task 2 was proposed by Boeing because it also would be beneficial to the analysis of composite grid-stiffened structures, specifically in generating models for preliminary design studies. The contract is now complete, this package includes copies of the user's documentation for Task 1 and a CD ROM & diskette with an electronic copy of the user's documentation and an updated version of the "GRID 99" spreadsheet.

Source record↗

Grid Value Analysis of Medium-Voltage Back-to-Back Converter on DER Hosting Enhancement

This paper presents an analysis of the value that can be realized by medium-voltage back-to-back (MVB2B) converters in terms of the increased utilization rate of distributed energy resources (DERs) and the improvement in operational conditions. A systematic, transferrable, and scalable methodology has been designed to analyze and quantify the increased DER value from three perspectives: 1) curtailment reduction of the DER generation, 2) size reduction of the energy storage needed to otherwise realize DER hosting levels, and 3) hosting capacity improvement of the DERs compared to the base distribution circuit capability. In the case study, the proposed methodology is applied to two utility distribution systems for analysis and quantification of the grid value of the MVB2B converter, installed in the distribution circuit, and provided to the solar photovoltaic (PV) DERs. Here, the analysis results demonstrate that the MVB2B converter can deliver significant value to the PV hosting enhancement of two adjacent distribution systems when they are connected by the MVB2B converter. Based on this case study, this paper analyzes and summarizes the approximate realized grid value of the MVB2B converter for distribution systems dominated by different shares of customer classes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving Trustworthiness of Data-Driven Power Grid Contingency Analysis With Bayesian Residual Graph Neural Networks

The evolving energy landscape requires novel tools to efficiently perform contingency analysis and reliability assessment of power grids, potentially in real-time. The high computational cost of traditional power flow solvers limits their applicability in practice. Machine learning (ML) surrogates such as deep neural networks (NNs) accelerate power flow solvers computations, enabling high-order contingency analysis and real-time decision-making by learning highly nonlinear functions and integrating grid topology via graph architectures. However, (graph) NNs lack predictive power away from training data and do not provide predictive confidence estimates. Here, we present a Bayesian residual graph NN that integrates knowledge from low-fidelity data via residual training and embeds granular quantification of uncertainties, improving trustworthiness critical for high-consequence decision-making. Applying Bayesian concepts to NNs is challenging due to the high-dimensionality of both the parameter space, complicating derivation of a meaningful prior, and the output space in large grid systems, requiring enhanced techniques to assess the predicted high-dimensional uncertainties. Our contributions include: (1) Deriving a prior for fully connected and graph NNs that leverages low-fidelity data to guide mean predictions and appropriately control prior predictive uncertainty. (2) Integrating this prior within an ensembling with anchoring scheme for efficient approximate posterior inference. (3) Deriving enhanced metrics to assess accuracy of both the mean and uncertainty predictions in high dimensions, appropriately accounting for correlations propagated through graph layers. The resulting Bayesian residual graph NN is tested on a contingency analysis task for 14-bus and 118-bus grids.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Grid Strength Analysis for Integrating 30 GW of Offshore Wind Generation by 2030 in the U.S. Eastern Interconnection: Preprint

Offshore wind is a key player in the transition to a decarbonized electric gird, and the United States has set ambitious goals of integrating 30 GW of offshore wind capacity by 2030 and 110 GW by 2050. To facilitate this integration, the National Renewable Energy Laboratory and the Pacific Northwest National Laboratory are conducting the Atlantic Offshore Wind Transmission Study to assess transmission solutions. To achieve the 110-GW target by 2050, meticulous planning for network expansion and resource allocation is essential; however, meeting the 2030 goals requires integrating offshore wind power with minimal system upgrades, thus necessitating a careful study of grid strength and stability. The study team developed the Grid Strength Analysis Tool (GSAT) to assess system strength under various operating conditions and contingencies, focusing on the proposed integration of 30 GW of offshore wind power by 2030. In this paper, we provide a summary of key features of the GSAT software and results of the grid strength analysis for integrating 30 GW of offshore wind generation by 2030 in the U.S. Eastern Interconnection.

Automated System-wide Strength Evaluation Tool (AS↗

A Methodology for Evaluating Operator Usage of Machine Learning Recommendations for Power Grid Contingency Analysis

This work presents the application of a methodology to measure domain expert trust and workload, elicit feedback, and understand the technological usability and impact when a machine learning assistant is introduced into contingency analysis for real-time power grid simulation. The goal of this framework is to rapidly collect and analyze a broad variety of human factors data in order to accelerate the development and evaluation loop for deploying machine learning applications. We describe our methodology and analysis, and we discuss insights gained from a pilot participant about the current usability state of an early technology readiness level (TRL) artificial neural network (ANN) recommender.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Modal Analysis for Grid Operation

MANGO software is to provide a solution for improving small signal stability of power systems through adjusting operator-controllable variables using PMU measurement. System oscillation problems are one of the major threats to the grid stability and reliability in California and the Western Interconnection. These problems result in power fluctuations, lower grid operation efficiency, and may even lead to large-scale grid breakup and outages. This MANGO software aims to solve this problem by automatically generating recommended operation procedures termed Modal Analysis for Grid Operation (MANGO) to improve damping of inter-area oscillation modes. The MANGO procedure includes three steps: recognizing small signal stability problems, implementing operating point adjustment using modal sensitivity, and evaluating the effectiveness of the adjustment. The MANGO software package is designed to help implement the MANGO procedure.

Zhou, Ning↗