Comparison of Irradiated and Unirradiated Graphite Oxidation Performance
This work examines the oxidation behavior of NBG-25 graphite using irradiated specimens and (not irradiated) companion specimens from the Advanced Graphite Creep (AGC) Experiment. Irradiated and companion specimens were quartered, split into four small samples, to enable four oxidation test runs for each (0.5 inch diameter by 0.25 inch tall) piggyback button obtained from the AGC Experiment inventory. These split samples were oxidized in air in a thermogravimetric analyzer (TGA) and benchmarked against observations with separately sourced same-grade specimens of three geometries oxidized either in the TGA or in a vertical furnace built and operated to satisfy the specifications of ASTM D7542. The study considers both irradiation damage and relief of damage by thermal annealing. A range of isothermal oxidation temperatures were tested for specimens exposed to a similar irradiation environment, nominally 6.5 dpa at 650°C. To assess the dose dependency of observed oxidation behavior, specimens with a range of irradiation exposures (up to 6.8 dpa) were tested at the single oxidation temperature of 650°C. In the conventional analysis (rate determined over the 5-10% mass loss range) any annealing effects appear to be negligible, while irradiation to ~6.5 dpa may double or triple the subsequent oxidation rate. However, examination of rate with extent of reaction (over incremental ranges from initial onset up to 5% mass loss) illustrates that (at least for ~6.5 dpa) irradiation initially inhibits oxidation. Slower rates of oxidation than companion split samples are clearly indicated across all oxidation temperatures tested up to ~0.5% mass loss. Over the range of 0.5-1% mass loss, regardless of normalization strategy, there is no statistically meaningful difference in oxidation rate. However, beyond 0.5% mass loss oxidation of the irradiated sample becomes progressively faster than the companion sample (up to the 10% mass loss level observed).