Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Development of a segmented n-type germanium detector, and its application to astronomical gamma-ray spectroscopy

Extensive calculations and simulations have shown that the instrumental background in a coaxial germanium photon detector flown at balloon altitudes or in space, can be substantially reduced by segmenting the outer contact. The contact is divided into horizontal strips around the side of the detector, giving it many characteristics similar to that of a stack of planar detectors. By choosing different segment coincidence requirements in different energy ranges, one can obtain a factor of approx. 2 increase in sensitivity to spectral lines between 40 keV and 1 MeV, compared with an unsegmented detector. The reverse electrode configuration (using n-type germanium), with the p contact outside, is preferred for this application due to its thin dead layer and resistance to radiation damage in space. A small two segment n type detector is being developed to serve as a prototype for larger multisegment devices. Results of this development effort and of detector tests are presented.

Gehrels, N.↗

The development of a segmented N-type germanium detector, and its application to astronomical gamma-ray spectroscopy

Extensive calculations and simulations have shown that the instrumental background in a coaxial germanium photon detector flown at balloon altitudes or in space, can be substantially reduced by segmenting the outer contact. The contact is divided into horizontal strips around the side of the detector, giving it many characteristics similar to that of a stack of planar detectors. By choosing different segment coincidence requirements in different energy ranges, one can obtain a factor of approx. 2 increase in sensitivity to spectral lines between 40 keV and 1 MeV, compared with an unsegmented detector. The reverse electrode configuration (using n-type germanium), with the p contact outside, is preferred for this application due to its thin dead layer and resistance to radiation damage in space. A small two segment n type detector is being developed to serve as a prototype for larger multisegment devices. Results of this development effort and of detector tests are presented. Previously announced in STAR as N84-13039

Gehrels, N.↗

Variable-Temperature Cryostat For Radiation-Damage Testing Of Germanium Detectors

Variable-temperature cryostats developed to study radiation damage to, and annealing of, germanium gamma-ray detectors. Two styles: one accommodates large single detector and one accommodates two medium-sized detectors. New cryostats allow complete testing of large-volume germanium gamma-ray detectors without breaking cryostat vacuum and removing detectors for annealing.

Floyd, Samuel R.↗

Gamma-ray observations of SN 1987A with an array of high-purity germanium detectors

A balloonborne gamma-ray spectrometer comprising an array of high-purity n-type germanium (HPGe) detectors surrounded by an active NaI(T1) collimator and Compton suppressing anticoincidence shield was flown on May 29-30, 1987. The average column depth of residual atmosphere in the direction of SN 1987A at float altitude was 6.3 g/sq cm during the observation. The 3-sigma upper limit obtained for the 1238-keV line from Co-56 is 0.0013 photons/sq cm s. The corresponding limit for the 847-keV line is 0.0017 photons/sq cm s.

Sandie, W. G.↗

High-energy proton radiation damage of high-purity germanium detectors

Quantitative studies of radiation damage in high-purity germanium gamma-ray detectors due to high-energy charged particles have been carried out; two 1.0 cm thick planar detectors were irradiated by 6 GeV/c protons. Under proton bombardment, degradation in the energy resolution was found to begin below 7 x 10 to the 7th protons/sq cm and increased proportionately in both detectors until the experiment was terminated at a total flux of 5.7 x 10 to the 8th protons/sq cm, equivalent to about a six year exposure to cosmic-ray protons in space. At the end of the irradiation, the FWHM resolution measured at 1332 keV stood at 8.5 and 13.6 keV, with both detectors of only marginal utility as a spectrometer due to the severe tailing caused by charge trapping. Annealing these detectors after proton damage was found to be much easier than after neutron damage.

Pehl, R. H.↗

Germanium detector vacuum encapsulation

This paper describes an encapsulation technology that should significantly improve the viability of germanium gamma-ray detectors for a number of important applications. A specialized vacuum chamber has been constructed in which the detector and the encapsulating module are processed in high vacuum. Very high vacuum conductance is achieved within the valveless encapsulating module. The detector module is then sealed without breaking the chamber vacuum. The details of the vacuum chamber, valveless module, processing, and sealing method are presented.

Madden, N. W.↗

Charged Particle Induced Radiation damage of Germanium Detectors in Space: Two Mars Observer Gamma-Ray Detectors

The Mars Observer Gamma-Ray Spectrometer (MO GRS) was designed to measure gamma-rays emitted by the Martian surface. This gamma-ray emission is induced by energetic cosmic-ray particles penetrating the Martian surface and producing many secondary particles and gamma rays. The MO GRS consisted of an high-purity germanium (HPGe) detector with a passive cooler. Since radiation damage due to permanent bombardment of energetic cosmic ray particles (with energies up to several GeV) was expected for the MO GRS HPGe crystal, studies on radiation damage effects of HPGe crystals were carried on earth. One of the HPGe crystals (paradoxically called FLIGHT) was similar to the MO GRS crystal. Both detectors, MO GRS and FLIGHT, contained closed-end coaxial n-type HPGe crystals and had the same geometrical dimensions (5.6 x 5.6 cm). Many other parameters, such as HV and operation temperature, differed in space and on earth, which made it somewhat difficult to directly compare the performance of both detector systems. But among other detectors, detector FLIGHT provided many useful data to better understand radiation damage effects.

Bruekner, J.↗

A position-sensitive germanium detector for gamma-ray astronomy

The critical problem in high-resolution cosmic gamma-ray spectroscopy in the energy range from 0.02 to 10 MeV is the limited spectral sensitivity of the detectors used. This results from the small effective area of the detectors and the high background noise due to induced radioactivity and scattering in the detectors' high-energy particle environment. The effective area can be increased by increasing the number of detectors, but this becomes prohibitive because of the size and expense of the resulting instrument. We have taken a new approach: a segmented large-volume germanium gamma-ray detector which can effectively discriminate against internal background yet maintain the high spectral resolution and efficiency of conventional coaxial Ge detectors. To verify this concept, a planar detector divided into two segments has been fabricated and laboratory measurements agree well with Monte Carlo calculations. A large coaxial detector which will be divided into five segments is being built using the techniques developed for the planar detector. Monte Carlo calculations show that the sensitivity (minimum detectable flux) of the segmented coaxial detector is a factor of 2-3 better than conventional detectors because of the reduction in the internal background.

Varnell, L. S.↗

High-Resolution Gamma-Ray Imaging Measurements Using Externally Segmented Germanium Detectors

Fully two-dimensional gamma-ray imaging with simultaneous high-resolution spectroscopy has been demonstrated using an externally segmented germanium sensor. The system employs a single high-purity coaxial detector with its outer electrode segmented into 5 distinct charge collection regions and a lead coded aperture with a uniformly redundant array (URA) pattern. A series of one-dimensional responses was collected around 511 keV while the system was rotated in steps through 180 degrees. A non-negative, linear least-squares algorithm was then employed to reconstruct a 2-dimensional image. Corrections for multiple scattering in the detector, and the finite distance of source and detector are made in the reconstruction process.

spectroscopy gamma ray germanium sensor nucleosynt↗

Neutron energy determination with a high-purity germanium detector

Two areas that are related to planetary gamma-ray spectrometry are investigated. The first task was the investigation of gamma rays produced by high-energy charged particles and their secondaries in planetary surfaces by means of thick target bombardments. The second task was the investigation of the effects of high-energy neutrons on gamma-ray spectral features obtained with high-purity Ge-detectors. For both tasks, as a function of the funding level, the experimental work was predominantly tied to that of other researchers, whenever there was an opportunity to participate in bombardment experiments at large or small accelerators for charged particles.

Beck, Gene A.↗

Simulation results of Pulse Shape Discrimination (PSD) for background reduction in INTEGRAL Spectrometer (SPI) germanium detectors

Pulse Shape Discrimination (PSD) for background reduction will be used in the INTErnational Gamma Ray Astrophysics Laboratory (INTEGRAL) imaging spectrometer (SPI) to improve the sensitivity from 200 keV to 2 MeV. The observation of significant astrophysical gamma ray lines in this energy range is expected, where the dominant component of the background is the beta(sup -) decay in the Ge detectors due to the activation of Ge nuclei by cosmic rays. The sensitivity of the SPI will be improved by rejecting beta(sup -) decay events while retaining photon events. The PSD technique will distinguish between single and multiple site events. Simulation results of PSD for INTEGRAL-type Ge detectors using a numerical model for pulse shape generation are presented. The model was shown to agree with the experimental results for a narrow inner bore closed end cylindrical detector. Using PSD, a sensitivity improvement factor of the order of 2.4 at 0.8 MeV is expected.

Slassi-Sennou, S. A.↗

Extension of long wavelength response by modulation doping in extrinsic germanium infrared detectors

A new concept for infrared detectors based on multilayer epitaxy and modulation doping has been investigated. This permits a high doping concentration and lower excitation energy in the photodetecting layer as is necessary for longer wavelength response, without incurring the detrimental effects of increased dark current and noise as would be the case with conventional detector designs. Germanium photodetectors using conventional materials and designs have a long wavelength cutoff in the infrared at 138 microns, which can only be extended through the inconvenient application of mechanical stress or magnetic fields. As a result of this approach which was arrived at from theoretical considerations and subsequently demonstrated experimentally, the long wavelength cutoff for germanium extrinsic detectors was extended beyond 200 microns, as determined by direct infrared optical measurements.

Hadek, V.↗

The HEAO 3 gamma-ray spectrometer

The third High Energy Astronomy Observatory (HEAO 3), successfully launched into low earth orbit on September 20, 1979, carries a large high-resolution gamma-ray spectrometer designed for cosmic nuclear spectroscopy. This gamma-ray spectrometer (the HEAO C-1 experiment) consists of a cluster of four coaxial high-purity germanium detectors, each with a volume of approximately 100 cu cm. Surrounding the germanium detectors is a 6.6-cm thick CsI shield operating in active anticoincidence with the central detectors and defining a field of view of about 30 deg FWHM. An initial energy resolution of 3 keV FWHM at 1.46 MeV was achieved for each detector. All valid events in the germanium detectors are individually analyzed by an 8192-channel pulse area analyzer and transmitted at a maximum rate of 15.6 evens/s for each detector. During a 6-month mission, the experiment will perform a complete sky survey for narrow cosmic gamma-ray line emission to the sensitivity level of about 0.0001 photons/sq cm s over an operating energy range of 0.05-10 MeV.

Mahoney, W. A.↗

Low background spectral response of 30-130-micron detectors from blackbody measurements

Low background far infrared detector responsivity and low background spectral response calibrations can be performed simultaneously with a cooled, temperature-swept blackbody. This makes the use of a cooled, low background spectrometer unnecessary in many applications. Calibrations of a beryllium-doped germanium detector showing unwanted 100-micron response, and of a gallium-doped germanium detector, are described.

Moore, W. J.↗

Gamma-ray burst and spectroscopy instrumentation development at the Goddard Space Flight Center

This paper summarizes the activities that are specifically related to the development of instrumentation for gamma-ray astronomy. Three programs are described: (1) the Gamma-Ray Imaging Spectrometer (GRIS), a balloon-borne array of seven germanium detectors for high-resolution spectrographic studies of persistent gamma-ray sources; (2) the Transient Gamma-Ray Spectrometer (TGRS), a single radiatively-cooled germanium detector for the spectrographic study of gamma-ray bursts, and (3) the Rapidly Moving Telescope (RMT), a ground-based optical telescope for the detection and study of short-lived optical transients, particularly those that occur in coincidence with gamma-ray bursts.

Teegarden, B. J.↗

16 November 1979 gamma-ray bursts observed with HEAO-3 High-Resolution Gamma-Ray Spectrometer

On 1979 November 16, two gamma-ray bursts were observed by the High-Resolution Gamma-Ray Spectrometer on HEAO-3. The first event occurred at 14:16:41 U.T. and lasted about eight seconds. This event was detected only by the instrument's five CsI anticoincidence shield pieces. The second event occurred 61 sec later, at 14:17:42, and lasted about 18 sec. This event was clearly detected by the high-resolution germanium detectors. Because of the close temporal coincidence of the two events, the possibility is considered that both events originated from one celestial source, and that the scanning motion of HEAO-3 (nominal spin period 20 min) excluded the first from the approximately 30 deg FWHM field of view of the germanium detectors but included the second. Directional information from the relative response of the five shield pieces and the earth occultation constraint are all consistent with this interpretation and suggest a source location near RA equals 10 hr, Dec equals 45 deg. No significant spectral features appear in the high-resolution data from the second burst.

Wheaton, W. A.↗