Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Geothermal Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Analysis of seismic moment tensors and in situ stress during Enhanced Geothermal System development at The Geysers geothermal field, California

Seismicity in the vicinity of an Enhanced Geothermal System (EGS) demonstration project in the Northwest Geysers at the Prati 32 (P-32) injection well and the Prati State 31 (PS-31) production well is investigated to determine earthquake focal mechanisms, moment magnitudes and in situ stress of events that occur before and during reservoir stimulation starting 2011 October 6. We present a catalogue of 167 waveform-based seismic moment tensors ranging in moment magnitude from 0.6 to 3.9. The moment tensor catalogue is subsequently used to invert for the stress tensor and to investigate possible temporal stress changes resulting from fluid injection. We find an approximate 15-degree counter-clockwise rotation of the least compressive stress σ3 during injection. More remarkable is a change in orientation of the maximum compressive stress σ1 from subhorizontal to vertical when injection operations temporarily cease. The orientation of σ1 returns to subhorizontal when injection operations resume. It is found that there was a systematic reduction in the stress shape factor, R, as the injected water volume increases, indicating an evolution towards a more transtensional stress state.

58 GEOSCIENCES↗

Electronic Submersible Pump (ESP) Technology and Limitations with Respect to Geothermal Systems (Fact Sheet)

The current state of geothermal technology has limitations that hinder the expansion of utility scale power. One limitation that has been discussed by the current industry is the limitation of Electric Submersible Pump (ESP) technology. With the exception of a few geothermal fields artificial lift technology is dominated by line shaft pump (LSP) technology. LSP's utilize a pump near or below reservoir depth, which is attached to a power shaft that is attached to a motor above ground. The primary difference between an LSP and an ESP is that an ESP motor is attached directly to the pump which eliminates the power shaft. This configuration requires that the motor is submersed in the geothermal resource. ESP technology is widely used in oil production. However, the operating conditions in an oil field vary significantly from a geothermal system. One of the most notable differences when discussing artificial lift is that geothermal systems operate at significantly higher flow rates and with the potential addition of Enhanced Geothermal Systems (EGS) even greater depths. The depths and flow rates associated with geothermal systems require extreme horsepower ratings. Geothermal systems also operate in a variety of conditions including but not limited to; high temperature, high salinity, high concentrations of total dissolved solids (TDS), and non-condensable gases.

15 GEOTHERMAL ENERGY↗

Machine Learning‐Assisted Microearthquake Location Workflow for Monitoring the Newberry Enhanced Geothermal System

Abstract Enhanced geothermal systems (EGS) offer a sustainable energy source but face challenges in accurately locating microearthquakes induced during reservoir stimulation. Locating these microearthquakes provides reliable feedback on the stimulation progress. Current deep learning methods for locating earthquakes require extensive data sets for training, which is problematic as detected microearthquakes are often limited. To address the scarcity of training data, we propose a practical workflow using probabilistic multilayer perceptron (PMLP) which predicts microearthquake locations from cross‐correlation time lags in waveforms. Utilizing a 3D velocity model of Newberry site derived from ambient noise interferometry, we generate numerous synthetic microearthquakes and 3D acoustic waveforms for PMLP training. Accurate synthetic tests prompt us to apply the trained network to the 2012 and 2014 stimulation field waveforms. To enhance the accuracy of source localization, we carefully handpick the P‐arrival times. Predictions on the 2012 stimulation data set show major microseismic activity at depths of 0.5–1.2 km, correlating with a known casing leakage scenario. In the 2014 data set, the majority of predictions concentrate at 2.0–2.9 km depths, consistent with results obtained from conventional physics‐based inversion, and align with the presence of natural fractures from 2.0 to 2.7 km. We validate our findings by comparing the synthetic and field picks, demonstrating a satisfactory match for the first arrivals. By combining the benefits of quick inference speeds and accurate location predictions, we demonstrate the feasibility of using realistic synthetic data set to locate microseismicity for EGS monitoring.

15 GEOTHERMAL ENERGY↗

High Temperature Stability of Aqueous Foams for Potential Application in Enhanced Geothermal System (EGS)

Enhanced Geothermal Systems (EGS) are typically constructed by injecting high-pressure water into the deep hot dry rocks (HDR) under carefully controlled conditions to create new or re-open existing fractures, which usually utilizes an immense quantity of water. Alternatively, aqueous foam-based fracturing fluids may offer potential advantages over conventional water-based fracturing fluid, including reduced consumption of water and environmental impact. Although foam-based fracturing has shown promising results in oil and gas industries, its applicability to EGS is unknown. Foams are complex mixtures of liquids with gaseous phases that are thermodynamically unstable. Their stability will decrease over time due to liquid drainage, bubble coarsening, and coalescence. Therefore, it is essential to stabilize foam fluids at high temperatures for EGS related applications such as fracking of HDRs.This paper is focused on investigating high-temperature stability of N2-in-water or N2 foams containing different surfactants and stabilizing agents. Foam stability was characterized by the half-life, which is defined as the time a foam decreases to 50% of its original height due to drainage. Surfactants with various concentrations dissolved in deionized water were investigated, including alfa olefin sulfonate (AOS), sodium dodecyl sulfonate (SDS), TergitolTM (NP – 40), and cetyltrimethylammonium chloride (CTAC). Also, the effects of other stabilizing agents, including guar gum, bentonite clay, crosslinker, graphene oxide (GO) dispersion on foam stability were tested. Initial results showed that foam stability decreased dramatically as temperature increased. On the other hand, foams became relatively more stable as pressure increased. Certain stabilizing agents, such as guar gum and crosslinker, can enhance foam stability at a wide range of temperatures. Our results indicate that it may be possible to obtain stable foams at high-temperature, high-pressure conditions with appropriate stabilizing agents.

Thakore, Virensinh↗

High Temperature, High Pressure Stability of Aqueous Foams for Potential Application in Enhanced Geothermal System (EGS)

Enhanced Geothermal Systems (EGS) are typically constructed by injecting high-pressure water into deep hot dry rocks (HDR) under carefully controlled conditions to create new or re-open existing fractures, which usually uses an immense quantity of water. In lieu, a more sustainable technique is to utilize aqueous foams as fracturing fluid to reduce water consumption and waste-water treatments of conventional hydraulic fracturing. Although foam-based fracturing has shown promising results in oil and gas industries, its feasibility is not demonstrated in EGS conditions that usually involve high temperature and high pressures. One potential barrier of utilizing foams in EGS applications is that foams are thermodynamically unstable and will become more unstable with increasing temperature due to liquid drainage, bubble coarsening, and coalescence. This work focuses on evaluation of the stability of selected aqueous foams under high-temperature and high-pressure conditions. Specifically, foams generated with surfactant alfa olefin sulfonate (AOS) were studied at temperature up to 200oC, while the pressure ranged between 100 psi and 1000 psi. The effect of additional stabilizing agents was also examined, including guar gum, bentonite clay, borate salt crosslinker, silicon dioxide nanoparticles (SiO2), and graphene oxide (GO) dispersion. Results showed that the stabilizing agents can enhance the foam thermal stability. Foams made with AOS and the borate salt crosslinker exhibited the longest half-life of 20 min at 200°C when the pressure was at 1000 psi. Data fitting showed that foam stability decreased exponentially as temperature increased. On the other hand, pressure increased the foam half-life which followed a power model. This study indicates that it may be possible to obtain highly stable foams at high-temperature and high-pressure conditions with appropriate stabilizing agents.

Thakore, Viren↗

3-Dimensional Geologic Modeling Applied to the Structural Characterization of Geothermal Systems: Astor Pass, Nevada, USA

Geothermal systems in the Great Basin, USA, are controlled by a variety of fault intersection and fault interaction areas. Understanding the specific geometry of the structures most conducive to broad-scale geothermal circulation is crucial to both the mitigation of the costs of geothermal exploration (especially drilling) and to the identification of geothermal systems that have no surface expression (blind systems). 3-dimensional geologic modeling is a tool that can elucidate the specific stratigraphic intervals and structural geometries that host geothermal reservoirs. Astor Pass, NV USA lies just beyond the northern extent of the dextral Pyramid Lake fault zone near the boundary between two distinct structural domains, the Walker Lane and the Basin and Range, and exhibits characteristics of each setting. Both northwest-striking, left-stepping dextral faults of the Walker Lane and kinematically linked northerly striking normal faults associated with the Basin and Range are present. Previous studies at Astor Pass identified a blind geothermal system controlled by the intersection of west-northwest and north-northwest striking dextral-normal faults. Wells drilled into the southwestern quadrant of the fault intersection yielded 94°C fluids, with geothermometers suggesting a maximum reservoir temperature of 130°C. A 3-dimensional model was constructed based on detailed geologic maps and cross-sections, 2-dimensional seismic data, and petrologic analysis of the cuttings from three wells in order to further constrain the structural setting. The model reveals the specific geometry of the fault interaction area at a level of detail beyond what geologic maps and cross-sections can provide.

15 GEOTHERMAL ENERGY↗

Geology and Hydrothermal Alteration of the Raft River Geothermal System, Idaho

The Raft River geothermal system is located in southern Idaho, near the Utah-Idaho state boarder in the Raft River Valley. The field, which is owned and operated by U.S. Geothermal, has been selected as an EGS demonstration site by the U. S. Department of Energy. This paper summarizes ongoing geologic and petrologic investigations being conducted in support of this project. The reservoir is developed in fractured Proterozoic schist and quartzite, and Archean quartz monzonite cut by younger diabase intrusions. The basement complex was deformed during the mid Tertiary and covered by approximately 5000 ft of late Tertiary sedimentary and volcanic deposits. Listric normal faults of Cenozoic age disrupt the Tertiary deposits but do not offset the basement rocks. RRG-9, the target well, was drilled southwest of the main well field to a measured depth (MD) of 6089 ft. The well is deviated to the west and cased to a depth of 2316 ft MD. It penetrated the Proterozoic reservoir rocks at a depth of 5286 ft MD and encountered a maximum temperature of 139 degrees C. Bottomhole temperatures in other deep wells range from 133 to 149 degrees C. X-ray diffraction and thin section analyses are being conducted on samples from 5 deep wells, RRG- 1, 2, 3, 7 and 9, to determine the characteristics of the rock types and hydrothermal alteration within the geothermal system. Thin section analyses of samples from RRG-9 document the presence of strong alteration and brecciation at the contact between the Tertiary and basement complex. The Tertiary rocks consist of ash-flow tuffs, lava flows, tuffaceous siltstone, greywacke, and sandstone. No core is available from RRG-9 but core was obtained from RRG-3C. The sample is a brecciated and altered siltstone from the base of the Tertiary sequence and is similar to rocks at the base of the Tertiary deposits in RRG-9. Here, the results of thermal and quasi-static mechanical property measurements that were conducted on the core sample are presented.

Jones, Clay↗

Neutron imaging for geothermal energy systems

Geothermal systems extract heat energy from the interior of the earth using a working fluid, typically water. Three components are required for a commercially viable geothermal system: heat, fluid, and permeability. Current commercial electricity production using geothermal energy occurs where the three main components exist naturally. These are called hydrothermal systems. In the US, there is an estimated 30 GW of base load electrical power potential for hydrothermal sites. Next generation geothermal systems, named Enhanced Geothermal Systems (EGS), have an estimated potential of 4500 GW. EGSs lack in-situ fluid, permeability or both. As such, the heat exchange system must be developed or engineered within the rock. The envisioned method for producing permeability in the EGS reservoir is hydraulic fracturing, which is rarely practiced in the geothermal industry, and not well understood for the rocks typically present in geothermal reservoirs. High costs associated with trial and error learning in the field have led to an effort to characterize fluid flow and fracturing mechanisms in the laboratory to better understand how to design and manage EGS reservoirs. Neutron radiography has been investigated for potential use in this characterization. An environmental chamber has been developed that is suitable for reproduction of EGS pressures and temperatures and has been tested for both flow and precipitations studies with success for air/liquid interface imaging and 3D reconstruction of precipitation within the core.

Bingham, Philip R↗

Stability study of aqueous foams under high-temperature and high-pressure conditions relevant to Enhanced Geothermal Systems (EGS)

In Enhanced Geothermal System (EGS) hydraulic fracturing is carried out by injecting cold water into deep Hot Dry Rocks (HDR) under carefully controlled conditions to create new or reopen existing fractures. Water-based fracturing fluids demonstrate some challenges including immense quantity of water usage, water sensitivity of the formations, water blocking, and lack of proppant carrying capacity and transportation. Thus, an alternative is to use foam-based fracturing fluid which offers potential advantage over conventional water-based fracturing fluid such as minimum water usage, reduced wellbore damage, high proppant carrying capacity, and less environmental damage. However, foams are complex mixture of gaseous phase and liquid phase which are thermodynamically unstable at downhole conditions, and their stability can decrease over time due to liquid drainage, bubble coarsening, and coalescence. This paper shows laboratory experiments executed to study foam stability at high temperature (200°C) and high pressure (6.9MPa) conditions which simulates the geothermal environment. Foam stability was characterized by half-life of foam, which is defined as the time taken by the foam to decreases by 50% of its original height due to drainage. In this paper, two types of gaseous phases, nitrogen (N 2 ) and carbon dioxide (CO 2 ) were investigated. Also, based on successful practice of foam-based fracturing fluid in oil and gas industries, four surfactants, including Alpha olefin sulfonate (AOS), Sodium dodecyl sulfonate (SDS), Tergitol™ (NP – 40), and Cetyltrimethylammonium chloride (CTAC) at optimum concentration of 1wt.% were tested for best stability performance. In addition, different stabilizing agents including guar gum, bentonite clay, crosslinker, silicon dioxide nanoparticles (SiO 2 ), graphene oxide (GO) were also studied. Experimental results showed that N 2 foams were more stable than CO 2 foams. It was observed that foam half-life decreased with the increase in temperature. Among all the surfactants, AOS foams showed the most promising thermal stability at high temperatures. Moreover, with the addition of stabilizing agents, foam's half-life was enhanced. Stabilizing agents such as crosslinker and GO dispersion showed the most stable foams with half-life recorded at 20min and 17min, respectively, at 200°C and 6.9MPa. Finally, pressure also showed a positive effect on foam stability; with increased pressure, foam half-life was increased. Based on the experimental data, analytical models for the effect of temperature and pressure were developed, considering foam degradation is a first-order kinetic reaction that linearly depends on the foam drainage mechanism. The effect of temperature on foam half-life was studied as an exponential decay model. In this model, foam half-life is a function of drainage rate constant (D A ) and activation energy (E a ) of the foam system. The effect of pressure on foam half-life was found to obey a power-law model where an increase in pressure showed an increase in foam half-life. Furthermore, a linear relation was studied for the effect of pressure on foam activation energy and drainage rate. Then the combined effects of temperature and pressure were studied, which yielded an analytical model to predict the foam stabilities in terms of half-life for different foam compositions. In conclusion, this research indicates that with an appropriate selection of surfactants and stabilizing agents, it is possible to obtain stable foams, which could replace conventional water fracturing fluid under EGS conditions.

15 GEOTHERMAL ENERGY↗

Influence of Reservoir Convection on Heat Extraction with Closed-Loop Geothermal Systems

Over the past few years, advancements in closed-loop geothermal systems (CLGS), also called advanced geothermal systems (AGS), have sparked a renewed interest in these types of designs. CLGS have certain advantages over traditional and enhanced geothermal systems (EGS), including not requiring in-situ reservoir permeability, conservation of the circulating fluid, and allowing for different fluids, including working fluids directly driving a turbine at the surface. CLGS may be attractive in environments where water resources are limited, rock contaminants must be avoided, and stimulation treatments are not available (e.g., due to regulatory or technical reasons). Despite these advantages, CLGS have some challenges, including limited surface area for heat transfer and requiring long wellbores and laterals to obtain multi-MW output in conduction-only reservoirs. CLGS have been investigated in conduction-only systems. In this paper, we explore the impact of both forced and natural convection on the levels of heat extraction with a CLGS deployed in a hot wet rock reservoir. We bound potential benefits of convection by investigating liquid reservoirs over a range of natural and forced convective coefficients. Additionally, we investigate the effects of permeability, porosity, and geothermal temperature gradient in the reservoir on CLGS outputs. Reservoir simulations indicate that reservoir permeabilities of at least ~100 mD are required for natural convection to increase the heat output with respect to a conduction-only scenario. The impact increases with increasing reservoir temperature. When subject to a forced convection flow field, Darcy velocities of at least 10-7 m/s are required to obtain an increase in heat output.

advanced geothermal systems↗

Experimental investigation of flow distribution in enhanced geothermal systems with deep eutectic solvent

Geothermal energy has been recognized as a valuable alternative to fossil fuels and nuclear power, as it is renewable and reliable. Enhanced Geothermal Systems (EGSs) have the potential to expand geothermal energy production by enabling access to previously untapped geothermal resources. Geothermal short-circuiting poses a significant challenge to EGS development, leading to reduced heat extraction. Deep Eutectic Solvent (DES) exhibits favorable thermal and rheological properties, making it a candidate for geothermal applications. Here, this paper examines Choline Chloride-Based Deep Eutectic Solvent (DES) as a working fluid in geothermal applications and its potential to mitigate geothermal short-circuiting. Hydraulic experiments using a dual fracture flow loop were conducted at high temperatures. The results showed that DES exhibited higher differential pressure behavior compared to water. Flow distribution results revealed that DES enhances flow allocation within the small fracture, particularly when a temperature difference exists between fractures. Specifically, DES increased flow distribution by an average of 11% when the temperature difference was 85°C, and by 13% when the difference was 45°C, relative to water. These findings suggest that DES responds to thermal fracture differences, making it a potential remedy to address geothermal short-circuiting.

15 GEOTHERMAL ENERGY↗

Searching for Blind Geothermal Systems Utilizing Play Fairway Analysis, Western Nevada

Geothermal play fairway analysis is a concept adopted from the oil industry aimed at improving the efficiency and success rate of geothermal exploration and drilling. It involves integration of multiple geologic and geophysical parameters indicative of geothermal activity as a means of identifying the most promising areas for new geothermal development. This includes the evaluation of the relative favorability of known, undeveloped geothermal systems, as well as assessing the probability of a particular area for hosting a relatively robust blind system (>~130°C). Finally, blind systems lack surface hot springs and steam vents and are thought to comprise the majority of geothermal systems in the Great Basin region.

15 GEOTHERMAL ENERGY↗

Discovery and analysis of a blind geothermal system in southeastern Gabbs Valley, Western Nevada

This study assessed the potential for high-temperature (≥130°C) blind geothermal systems in southeastern Gabbs Valley by employing a geothermal play fairway analysis approach involving integration of geologic, geophysical, and geochemical datasets. Gabbs Valley is a complex, tectonically active basin within the Great Basin on the boundary between the transtensional central Walker Lane domain and extensional Basin and Range province. The termination of the Petrified Springs fault, a major dextral fault of the central Walker Lane, in an array of normal faults indicates that southeastern Gabbs Valley occupies a displacement transfer zone, which is a favorable structural setting for geothermal activity. The displacement transfer zone is a structurally complicated area with many faults of varying geometries, kinematics, and ages. A substantial northwest-trending gravity high within the south-central part of southeastern Gabbs Valley is produced from offsets along concealed northwest-striking dextral-normal faults that intersect strands of north-northeast-to east-northeast-striking normal faults. This area of tightly spaced faults and fault intersections is a particularly favorable structural setting within the broader-scale displacement transfer zone. Multiple lines of direct and indirect evidence suggest the presence of a relatively high-temperature (≥130°C) blind geothermal system in this area, including collocated intersecting gravity gradients, magnetic-low, low-resistivity, and 2-m temperature anomaly. Potentially related, water samples from agricultural wells ~7 km northwest of the 2-m anomaly yield geothermometers indicating subsurface fluid temperatures of 130-140°C. Six temperature-gradient holes were drilled to target the extent of the shallow-temperature and geophysical anomalies to define the geothermal system in southeastern Gabbs Valley. Two wells contained high temperatures exceeding boiling with bottom-hole temperatures ii of 114.5°C and 124.9°C, respectively, and the remaining wells displayed elevated to background temperatures ranging from 79.2°C to 28.7°C. The observed temperature gradients for the two hottest drill holes necessitate drill-hole intercepts of convecting hydrothermal fluids. The 2-m survey is spatially and thermally consistent with the temperature-gradient holes and constrains the core of upflow at a shallow depth interval (<250m) to an area <0.5-1 km west-southwest of the hottest drill hole. The zone of inferred upwelling occupies the area corresponding to the center of the magnetic-low. This project has several significant implications. The newly discovered blind geothermal system in southeastern Gabbs Valley may be capable of supporting a binary-type geothermal power plant. This detailed study provides an initial validation of the play fairway approach to geothermal exploration. It also demonstrates both the broad applicability of the play fairway exploration strategy and the large untapped potential for commercial-grade blind geothermal systems in many of the basins in the Great Basin region.

15 GEOTHERMAL ENERGY↗

Conceptual model of the Tatun geothermal system, Taiwan

Here, the Tatun geothermal system, located in northern Taiwan, is hosted by the Plio-Pleistocene Tatun volcanic group, consisting dominantly of andesitic lavas, domes and pyroclastic flows. During the late 1960s and early 1970s, geologic mapping, geochemical sampling, geophysical surveys, and the drilling of numerous exploration and temperature gradient wells were conducted at Tatun under the leadership of the Mineral Research and Service Organization (MRSO), the predecessor to the geothermal group at the Industrial Technology Research Institute (ITRI). Deep (1–2 km) wells encountered commercial temperatures (200–300 °C) in the Matsao area, but these initial exploration efforts were discouraged by the presence of very acidic (pH < 3.5) and highly corrosive fluids. Numerous geoscience studies conducted over the past 15 years at Tatun have shown that the central portion of the system is dominated by corrosive volcanic fluids, as evidenced by abundant SO 2 as well as HCl. More reduced gases are encountered on the flanks of the system, suggesting that water-rock interaction may have at least partly neutralized the volcanic-derived fluids on the margins of this geothermal system.

15 GEOTHERMAL ENERGY↗

Modeling of heat extraction from variably fractured porous media in Enhanced Geothermal Systems

Modeling of heat extraction in Enhanced Geothermal Systems is presented. The study builds on recent studies on the use of directional wells to improve heat transfer between doublet injection and production wells. The current study focuses on the influence of fracture orientation on production temperature in deep low permeability geothermal systems, and the effects of directional drilling and separation distance between boreholes on heat extraction. The modeling results indicate that fracture orientation with respect to the well-pair plane has significant influence on reservoir thermal drawdown. As a result, the vertical well doublet is impacted significantly more than the horizontal well doublet

15 GEOTHERMAL ENERGY↗

3D characterization of a Great Basin geothermal system: Astor Pass, NV

The Great Basin exhibits both anomalously high heat flow (~75±5 mWm-2) and active faulting and extension resulting in robust geothermal activity. There are ~430 known geothermal systems in the Great Basin, with evidence suggesting that undiscovered blind geothermal systems may actually represent the majority of geothermal activity. These systems employ discrete fault intersection/interaction areas as conduits for geothermal circulation. Recent studies show that steeply dipping normal faults with step-overs, fault intersections, accommodation zones, horse-tailing fault terminations and transtensional pull-aparts are the most prominent structural controls of Great Basin geothermal systems. These fault geometries produce sub-vertical zones of high fault and fracture density that act as fluid flow conduits. Structurally controlled fluid flow conduits are further enhanced when critically stressed with respect to the ambient stress conditions. The Astor Pass blind geothermal system, northwestern Nevada, lies along the boundary between the Basin and Range to the east and the Walker Lane to the west. Along this boundary, strain is transferred from dextral shear in the Walker Lane to west-northwest directed extension in the Basin and Range. As such, the Astor Pass area lies in a transtensional setting consisting of both northwest-striking, left-stepping dextral faults and more northerly striking normal faults. The Astor Pass tufa tower implies the presence of a blind geothermal system. Previous studies suggest that deposition of the Astor Pass tufa was controlled by the intersection of a northwest-striking dextral normal fault and north-northwest striking normal fault. Subsequent drilling (to ~1200 m) has revealed fluid temperatures of ~94°C, confirming the presence of a blind geothermal system at Astor Pass. Expanding upon previous work and employing additional detailed geologic mapping, interpretation of 2D seismic reflection data and analysis of well cuttings, a 3-dimensional geologic model of the Astor Pass blind geothermal system was constructed. The 3D structural framework indicates that the Pleistocene tufa is associated with three discrete fault zones whose intersections plunge moderately to steeply NW-NNW. These critically stressed fault intersections act as conduits for upwelling geothermal fluids.

15 GEOTHERMAL ENERGY↗

Discovery and analysis of a potential blind geothermal system in southern Gabbs Valley, western Nevada

The southern Gabbs Valley geothermal prospect is a blind thermal anomaly located 5 km north of the Gabbs Valley Range and ~15 km southeast of the Don A. Campbell geothermal power plant in west-central Nevada. The discovery of this blind thermal anomaly was initiated from the development of a detailed geothermal potential map covering 96,000 km2 of the Great Basin region. This map synthesized about 9 geologic and geophysical parameters and showed high geothermal potential in southern Gabbs Valley. Subsequent geologic reconnaissance identified areas of favorable structure for hosting a blind geothermal system. Areas displaying complex fault relationships were then targeted for further exploration utilizing a shallow 2-meter thermal survey. The first 2-meter survey incorporated 60 data points in the basin, with one anomalously high temperature point located in the southern portion of the basin. Water samples were taken from the Diamond A ranch 6 km northwest of the thermal anomaly. These samples yielded a geothermometer of 130-140°C. Additional shallow temperature survey work has been completed constraining the extent of the thermal anomaly and establishing a 7 km2 area with elevated 2-meter temperatures. Subsurface data generated from a new gravity survey show that the 2-meter thermal anomaly corresponds to a significant gravity gradient that probably reflects a subsurface fault and possible fault intersection. Exploration of the system is ongoing, and further detailed mapping of bedrock and Quaternary exposures in the area will aid in understanding the structural controls of this potential geothermal system. The integration of geochemical, geophysical, and geologic datasets in this area will elucidate the probability of a commercial-grade geothermal system and produce a conceptual model to be used in the selection of possible drill targets.

15 GEOTHERMAL ENERGY↗