Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gasket”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Liquid-Oxygen-Compatible Cement for Gaskets

Fluorelastomer and metal bonded reliably by new procedure. To cure fluoroelastomer cement, metal plate/gasket assembly placed in vacuum bag evacuated to minimum vacuum of 27 inches (69 cm) of mercury. Vacuum maintained throughout heating process and until assembly returns to ambient room temperature. Used to seal gaskets and O-rings or used to splice layers of elastomer to form non-standard sized O-rings. Another possible use is to apply protective, liquid-oxygen-compatible coating to metal parts.

Elmore, N. L.↗

Pressure concentrations due to plastic deformation of thin films or gaskets between anvils

Plastic deformation of either a sample or a gasket between diamond anvils leads to large pressure concentrations, i.e., the maximum pressure can be many times the average pressure. This behavior is discussed using elementary plasticity theory for the case where the pressures are sufficiently low that the yield stress can be assumed not to vary with pressure. It is then shown that the pressure concentration factor can be even much larger when the yield stress of the sample at the highest pressure is much greater than the yield stress at the lowest pressure. This is illustrated with solid xenon where it is shown that the assumption that Nelson and Ruoff made about the pressure distribution in their xenon samples is incorrect. The pressure distribution is shown to be much steeper than assumed. Thus, the pressure they observed electrical conduction in xenon was above 1 Mbar.

Chan, K. S.↗

Making Intricate, Thin Gaskets

Effective but inexpensive method developed for quickly fabricating intricate thin-film elastomeric seals for use in instrumentation manifolds. Uses aluminum stock and standard machine practices to prepare intricate thin-film seals quickly. Holes burned through gasket material with hot probes, using aluminum fixture for precise alignment.

Geouge, Wayne D.↗

O-ring gasket test fixture

An apparatus is presented for testing O-ring gaskets under a variety of temperature, pressure, and dynamic loading conditions. Specifically, this apparatus has the ability to simulate a dynamic loading condition where the sealing surface in contact with the O-ring moves both away from and axially along the face of the O-ring.

Turner, James Eric↗

Indium Foil Serves As Thermally Conductive Gasket

Indium foil found useful as gasket to increase thermal conductance between bodies clamped together. Deforms to fill imperfections on mating surfaces. Used where maximum temperature in joint less than melting temperature of indium. Because of low melting temperature of indium, most useful in cryogenic applications.

Eastman, G. Yale↗

Investigation of Bolt Preload Relaxation for JWST Thermal Heat Strap Assembly Joints with Aluminum-1100 and Indium Gaskets

Accurately predicting fastener preload relaxation in the James Webb Space Telescope (JWST) heat strap assemblies is essential to insure adequate thermal performance during its mission lifecycle. The mechanisms for preload relaxation in the strap joints include Al-1100 material creep, indium gasket flow-out, and embedment of the joint faying surfaces. This report documents the results from a bolted joint relaxation test, including analysis and curve fitting of the test data for predicting preloads five years after initial torque application. The report also includes the derivation of a preload uncertainty factor enveloping both torque/preload application scatter and expected preload relaxation at the end of mission life.

Joint↗

Investigation of Bolt Preload Relaxation for JWST Thermal Heat Strap Assembly Joints with Aluminum-1100 and Indium Gaskets

Accurately predicting fastener preload relaxation in the James Webb Space Telescope (JWST) heat strap assemblies is essential to insure adequate thermal performance during its mission lifecycle. The mechanisms for preload relaxation in the strap joints include Al-1100 material creep, indium gasket flow-out, and embedment of the joint faying surfaces. This report documents the results from a bolted joint relaxation test, including analysis and curve fitting of the test data for predicting preloads five years after initial torque application. The report also includes the derivation of a preload uncertainty factor enveloping both torque/preload application scatter and expected preload relaxation at the end of mission life.

Preload↗

Sealing Assembly for Sealing a Port and the Like

The sealing assembly for a port of a valve or the like is disclosed. In detail, the sealing assembly includes the port having a circular shaped end with a circular shaped knife-edge thereon. The sealing assembly further includes a hollow cap having a closed first end with an aperture therethrough and an open second end. The cap further includes internal threads adapted to mate with the external threads of the port. A gasket is mounted within the cap having flat first and second principle sides and made of a deformable metal, the first principle side of the gasket for mounting against the circular shaped knife edge of the port. A plunger having a circular shaped disc portion is adapted to fit within the hollow cap and is engagable with the first principle surface of the gasket and includes a shaft portion extending out of the aperture. The cap and shaft of the plunger include external wrenching flats. Thus when the cap is screwed onto the port and the plunger is prevented from rotating by a wrench mounted on the wrenching flats of the shaft portion of the plunger, the gasket is forced into engagement with the knife edge in pure compression and no rotation of the gasket occurs causing the knife edge to locally deform the gasket sealing of the port.

Jon W Haas↗

Continuous self-locking spiral wound seal

A spiral wound seal for effecting a seal between two surfaces is described. The seal consists of a strip of gasket material wound into a groove machined into one of the surfaces. The gasket strip is wider than the groove is deep so that a portion of the gasket material protrudes from the groove. The seal is effected by clamping the second surface onto the first surface and compressing the protruding gasket material.

Irick, S. C.↗

Improvement of Odor Control for the UWMS Hard-Sided Fecal Canister and the Alternate Fecal Canister

On longer range exploration missions, the mass and volume of critical hardware and consumables required to support crew will pose a big stowage challenge. This includes the hardware for the collection and storage of human metabolic solid waste. The amount of stowage needed for this hardware both before (empty) and after (full) use will be a significant burden on the overall spacecraft habitable volume, layout, and design. To help with this challenge, the National Aeronautics and Space Administration (NASA) Mars Campaign Office (MCO) Logistics Reduction (LR) Portfolio has developed a collapsible canister for the collection and containment of fecal deposits. The Alternate Fecal Canister (AFC) is a collapsible alternative to the exploration toilet Hard-sided Fecal Canister (HFC). The AFC in its empty state has a volumetric benefit to smaller vehicles on longer missions. The current designs for HFC and AFC were tested with human fecal material for odor containment at White Sands Test Facility (WSTF) where the tests on both were unsuccessful. The source of the lack of containment was isolated to a gasket used on both HFC and AFC. The gasket used was found to be open cell in design. This paper provides a summary of the materials selection and testing process to identify a replacement gasket material with the intention to replace the gaskets on both existing units as well as incorporate it into the designs going forward for future builds for exploration. Details will be provided on the design of the canisters interface with the odor bacteria lid which led to the selection of the thickness of the desired replacement. Finally, the paper will provide an update on the testing in advance of a return to WSTF for final testing and detail plans to complete testing and perform a demonstration on ISS with UWMS.

ECLSS↗

Improvement of Odor Control for the UWMS Hard-Sided Fecal Canister and the Alternate Fecal Canister

On longer range exploration missions, the mass and volume of critical hardware and consumables required to support crew will pose a big stowage challenge. This includes the hardware for the collection and storage of human metabolic solid waste. The amount of stowage needed for this hardware both before (empty) and after (full) use will be a significant burden on the overall spacecraft habitable volume, layout, and design. To help with this challenge, the National Aeronautics and Space Administration (NASA) Mars Campaign Office (MCO) Logistics Reduction (LR) Portfolio has developed a collapsible canister for the collection and containment of fecal deposits. The Alternate Fecal Canister (AFC) is a collapsible alternative to the exploration toilet Hard-sided Fecal Canister (HFC). The AFC in its empty state has a volumetric benefit to smaller vehicles on longer missions. The current designs for HFC and AFC were tested with human fecal material for odor containment at White Sands Test Facility (WSTF) where the tests on both were unsuccessful. The source of the lack of containment was isolated to a gasket used on both HFC and AFC. The gasket used was found to be open cell in design. This paper provides a summary of the materials selection and testing process to identify a replacement gasket material with the intention to replace the gaskets on both existing units as well as incorporate it into the designs going forward for future builds for exploration. Details will be provided on the design of the canisters interface with the odor bacteria lid which led to the selection of the thickness of the desired replacement. Finally, the paper will provide an update on the testing in advance of a return to WSTF for final testing and detail plans to complete testing and perform a demonstration on ISS with UWMS.

Toilet↗

Heat and Pressure Seal for Doors

Proposed tubular gasket for doors performs dual function: seals in pressure, and seals out heat. Composed of quartz fabric filled with alumina matting, gasket is bonded with room-temperature-vulcanizing material to periphery of door. When door is closed, gasket is compressed like O-ring: fills gap between door and frame; and prevents leakage of air and heat.

Gillespie, C. A.↗

Hermetic edge sealing of photovoltaic modules

The feasibility of using an electrostatic bonding (ESB) and ultrasonic welding process to produce hermetic edge seals on terrestrial solar cell modules was investigated. The fabrication sequence is to attach an aluminum foil "gasket' to the perimeter of a glass sheet. A cell circuit is next encapsulated inside the gasket, and its aluminum foil back cover is seam welded ultrasonically to the gasket. An ESB process for sealing aluminum to glass was developed in an ambient air atmosphere, which eliminates the requirement for a vacuum or pressure vessel. An ultrasonic seam welding process was also developed which did not degrade the quality of the ESB seal. Good quality welds with minimal deformation were produced. The effectiveness of the above described sealing techniques was tested by constructing 400 sq cm (8 x 8 s64 sq in) sample modules, and then subjecting them to nondestructive fine and gross leak tests. The gross leak tests identified several different causes of leaks which were then eliminated by modifying the assembly process.

Nowlan, M. J.↗

Helium Balloon Valve Improvement

The NASA Balloon Program Office (BPO), located at Wallops Flight Facility asked the Mechanical Systems Branch (Code 548) to improve the design of their balloon valve. BPO uses two main types of balloons, Zero Pressure Balloon (ZPB) and Super Pressure Balloon (SPB), which both use the valve. It is used for termination of the ZPB, and inflation and termination of the SPB. During launch campaigns the valve showed signs of helium leakage which lead the BPO to ask for an improvement. As part of a Professional Readiness Engineering Program (PREP), research and review of the current valve was conducted and a new design was prepared. The current custom designed valve consists of a "pie" plate that is actuated up and down via a gear rack that is driven by a globe motor. When closed the knife edge of the pie plate bites into a silicone gasket to seal the structure. Unfortunately, the gasket material permanently deforms after being compressed and the plate itself bends under the force induced by the motor, introducing two possible helium leak paths. The new custom designed valve utilizes o-rings instead of one gasket to reduce the possibility of leakage from permanent deformation. One o-ring seals the valve structure to its mating surface and a spring energized o-ring is used in a piston design to seal the valve once it's closed. The design also utilizes different materials to increase stiffness and strength so that it is less likely to bend under the force from the motor. Currently the new valve has finished the design and analysis phases and is proceeding towards manufacturing and testing.

Seo, Lindsey↗