Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Gaseous detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Performance of the LHCb muon detector in Run 3

In Run 3 of the LHC, the instantaneous luminosity at the LHCb interaction point has been increased by a factor of five, from to $\mathscr{L}$ = 4 x 10 32 cm -2 s -2 to $\mathscr{L}$ = 2 x 10 33 cm -2 s -1 . Several hardware interventions, including a complete overhaul of the readout electronics, have been carried out on the muon detector. The muon identification algorithms in the software trigger were improved with the aim of ensuring Run 2 performance under a higher particle rate. The operation and calibration of the upgraded muon detector are presented. The muon detection efficiency and muon identification performance are evaluated on data calibration samples collected during the year 2024. A muon identification efficiency above 90% with sub-percent hadron misidentification probability is achieved by exploiting the pattern of hits in the muon detector.

Gaseous detectors

SALSA: a new versatile readout chip for MPGD detectors

The SALSA chip is a future readout ASIC foreseen for the MPGD detectors, developed in the framework of the EIC collider project, to equip the MPGD trackers of the EPIC experiment. It is designed to be versatile, to be adapted to other usages of MPGD detectors like TPC or photon detectors. It integrates a frontend block and an ADC for each of the 64 channels, associated to a configurable DSP processor meant to correct data and reduce the raw data flux to limit the output bandwidth. It will be compatible with the continuous readout foreseen for the EPIC DAQ, but will also work in a triggered environment. Several prototypes are already produced in order to qualify the different blocks of the chip, in particular the frontend, the ADC and the clock generation. The next 32-channel prototype is currently under development and is planed to be produced in 2025. In conclusion, the final prototype will be produced and tested from 2026 for a production of the SALSA chip at the horizon of 2027.

Data processing

Early Career Award: Single Molecule Fluorescence Imaging for a Background-Free Neutrinoless Double Beta Decay Search

This project aimed to develop a suite of novel technologies targeted at detecting individual barium ions produced in neutrinoless double beta decays of 136 Xe, as part of the NEXT program of gaseous xenon detectors. We realized novel molecules which could sense Ba 2+ ions in dry conditions; new microscopy techniques operable in dry noble gases, including the required operating conditions of xenon at 10 bar pressure; and new radiofrequency ion transport methods (developed both theoretically and experimentally) that can transport ions in dense xenon gas. Together, these developments represent a major advance toward a background-free neutrinoless double beta decay experiment based on single molecule fluorescence imaging of Ba 2+ daughter ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

LArCADe | Liquid Argon Charge Amplification Devices

The Liquid Argon Charge Amplification Devices (LArCADe) project is an R$\&$D effort aimed at developing instrumentation capable of lowering detection thresholds for ionization signatures in liquid and gaseous argon detectors and achieving O(100 $\mu$m) position resolution. The core concept is the use of sharp “tip arrays” that generate strong local electric-field enhancement, enabling charge amplification and collection with improved spatial resolution. A key physics motivation for this work is to enhance the experimental sensitivity of Coherent Elastic Neutrino-Nucleus Scattering (CEvNS) measurements to low-energy nuclear recoils by enabling spatially resolved charge reconstruction at reduced ionization thresholds, with the goal of achieving event-by-event energy reconstruction for interactions originating from localized accelerator or astrophysical neutrino sources. This poster will present the current status of the instrumentation R$\&$D, which leverages Fermilab’s Noble Liquid Test Facility and UC Santa Barbara’s Nanofabrication Facility, and will discuss the potential physics impact of this technology.

Antonakis, Alexander [UC, Santa Barbara]

Anode sensitivity calibration of photomultiplier tubes used as a readout of the ELOSS detector

We present and discuss the methodology and results for an anode sensitivity calibration of Photomultiplier Tubes (PMTs) that serve as the optical readout of the Energy Loss Optical Scintillation System (ELOSS). The ELOSS detector, under development at the Facility for Rare Isotope Beams (FRIB), is a gaseous Xe scintillation-based detector designed to identify the atomic number (Z) of nuclear reaction fragments by energy-loss measurement. Variation in the anode sensitivity from tube to tube of commercially available PMTs limits ELOSS from reaching its ultimate Z resolution. A methodical approach to calibrating PMT anode sensitivities to a single target value by systematic PMT gain corrections is presented. Although the calibration process is discussed in terms of its impact on ELOSS performance, the presented method is applicable to any optical detector system composed of a large number of PMTs needing anode sensitivity calibration.

Instrumentation for heavy-ion accelerators

Detection of scintillation light in noble gases with wavelength-shifting optical fibers

Wavelength-shifting (WLS) techniques enable particle detectors based on noble gases, whose scintillation light is predominantly emitted in the vacuum-ultraviolet. We investigate WLS fibers coated with tetraphenyl butadiene (TPB) for scintillation light detection in gaseous xenon and argon at pressures up to 8.5 bar, motivated by future high-pressure xenon time-projection chambers of the NEXT program. Two detector configurations are studied: an elongated high-pressure vessel with four PTFE panels equipped with WLS fibers read by temperature-stabilized SiPMs, and a compact box-shaped detector operated at 1 bar Xe with WLS fibers read out by PMTs. Both operate with continuous gas purification. The detector response is characterized using cosmic muons and alpha particles from a $^{241}$Am source. With the SiPM setup, we measure a light collection efficiency (LCE) of ${1.18 \pm 0.01~\mathrm{(sta.)}~^{+0.07}_{-0.09}~\mathrm{(sys.)}~\%}$ for xenon and ${1.07 \pm 0.01~\mathrm{(sta.)}~^{+0.06}_{-0.08}~\mathrm{(sys.)}~\%}$ for argon. With PMT readout, we measure a LCE of ${0.45 \pm 0.01~\mathrm{(sta.)} \pm 0.05~\mathrm{(sys.)}~\%}$ in xenon, in agreement with the SiPM result once photon detection efficiency is accounted for. Average scintillation waveforms in xenon and argon are studied to assess the time structure of the emitted light. Cosmic-muon measurements yield a mean energy required to produce a scintillation photon $45\pm7~\mathrm{(sta.)}~^{+4}_{-5}~\mathrm{(sys.)}~\mathrm{eV}$ at 1.5 bar, in agreement with the literature. The results demonstrate that TPB-coated WLS fiber systems can reliably detect scintillation light in high-pressure gaseous noble detectors, with a LCE representing an upper limit for realistic large-scale TPCs, where additional photon losses from materials and fiber attenuation are expected.

Soleti, S. R. [Donostia Intl. Phys. Ctr., San Seba

THE STRUCTURE FUNCTION OF THE FREE NEUTRON AT HIGH X-BJORKEN

Understanding the internal structure of nucleons is one of the primary goal of nuclear physicists. As protons and neutrons are only the bound state solution of the QCD lagrangian (at least inside atomic nuclei), studying protons and neutrons helps uncover nuclear struc ture. Due to its easy availability, many studies on protons have been done on a wide range of kinematics. However, free neutron targets are not readily achievable. So, any information on neutrons has to be extracted from neutron-rich nuclei, and some nuclear models have to be used to subtract the contributions from other nucleons to extract the information on neutrons. So, the Barely Off-shell Nucleon Structure (BONuS12) experiment at Jefferson Lab was conducted to overcome these challenges by using spectator tagging. The experiment effectively created a quasi-free neutron target by scattering electrons off a deuterium target and detecting low-momentum, backward-moving protons using a custom-built Radial Time Projection Chamber (RTPC). Selecting the low momentum and backward-moving spectators would enable us to minimize the model-dependent effects due to final state interactions and target fragmentation. The RTPC was a 40 cm-long cylindrical detector that works on the principle of gaseous ionization. It had three layers of Gas Electron Multipliers (GEMs) for charge amplification and a surrounding readout pad. The scattered electrons were measured using the CLAS12 detector, and data were collected using a 10.4 GeV electron beam dur ing Spring and Summer 2020. Using spectator tagging, we extracted the structure function ratio Fn 2 of the quasi-free neutron in the deep inelastic scattering at high x, upto x ~ 0.8. The result was extracted in the region with the invariant mass W > 1.8 GeV/c2, and Q2 in the range 1.3 to 11 GeV2. This dissertation presents the methodology, event selection criteria and refinements, estimation and subtraction of backgrounds, and complete analysis of extraction of Fn 2/Fp 2 in a model-independent way. Also, systematic uncertainties in our final analysis will be discussed in detail.

Pokhrel, Madhusudhan [Old Dominion Univ., Norfolk,

A New Measurement of the Neutron Electric Form Factor with the Super Bigbite Spectrometer Apparatus

Protons and neutrons, collectively known as nucleons, make up the nuclei at the core of atoms which form our world. The nucleon has been under intensive study for over 100 years, and yet we still do not fully understand the internal dynamics which govern properties like its spin or its mass-which contributes to almost all of the visible mass in the universe. These dynamics are governed by quantum chromodynamics(QCD), the predictions of which are experimentally tested at high energy accelerator facilities such as Jefferson Lab. TheGEN-II experiment (E12-09-016) is one such experiment. GEN-II is part of the Super Bigbite Spectrometer (SBS) experimental form factor pro gramme taking place in Hall A at Jefferson Lab, which aims to make precision measurements of the nucleon electromagnetic form factors(EMFFs)at record high values of squared four momentum transfer ¿2. EMFFs describe the electric and magnetic moment distributions within the nucleon. They can be measured through elastic electron scattering off the nucleon, and describe the recoil response of the target nucleon at a given energy scale. GEN-II is a double polarized semi-exclusive beam target asymmetry (BTA) experiment, seeking to measure the electric form factor of the neutron,¿¿ ¿,at three new values of squared four-momentum transfer¿2 =2.92,6.74and9.82GeV². The latter two points being at record high ¿2. The form factor is determined through measuring the BTA of quasielliptical scattering of a neutron from a polarized nuclear target. The experiment utilized the CEBAF accelerator to produce longitudinally polarized electrons up to ~85% polarization, which were scattered off neutrons within a novel polarized helium-3 (³He) target. This new polarized ³He target was employed by building on the technology of its precursors which existed in similar preceding experiments. This target was designed to operate at the high luminosities typical of Hall A, and reached a record breaking combination of polarization and beam intensity known as figure of merit, three times larger than those predecessors. The SBS collaboration designed and constructed two brand new high acceptance spectrometers for these experiments, an electron arm named Bigbite (BB) and a hadron arm named Super Bigbite. Both spectrometers featured a large acceptance EM dipole magnet, and complementary detector systems. The electron arm contained gaseous electronmultipliers(GEMs) which were used for high precision tracking of the scattered electrons, a heavy gas cherenkov (GRINCH) which was used for PID between electrons and pions, a plastic i ii scintillator timing hodoscope to provide high resolution timing of the start of events, and a pair of EM calorimeters (BBCal) which provided energy measurements of detected particles, and provided the experimental trigger. The hadron arm also contained a system of GEMs which will be utilized for future SBS experiments, and a hadron calorimeter designed to provide position, timing and energy measurements of the recoiling nucleon. The calibration of all detector subsystems, beam and target data is discussed, with a focus on novel timing calibrations to the hodoscope and hadron calorimeter. An analysis of selecting quasielliptical events and suppressing background contributions from a number of sources which contaminate the final event sample is given. The largest irreducible backgrounds are found to be from misidentified protons, timing accidentals and inelastic events. The physical asymmetry is measured and used to extract a value for the form factor ratio ¿¿ ¿/¿¿ ¿. High precision ¿2 data for ¿¿ ¿ is used to then extract ¿¿ ¿. This work finds at ¿2 = 2.92 GeV2 that ¿¿ ¿ = 0.0129+0.0019 -0.0020. This result is in statistical agreement with existing fits to world data, and predictions from the constituent quark model and Dyson–Schwinger equations, in this region of ¿2.

Penman, Gary [Univ. of Glasgow, Scotland (United K

SCGSR Final Report

Dual phase noble liquid time projection chambers (TPCs) have an unprecedented sensitivity towards dark matter searches and neutrinos, owing to their ability to detect single electrons. When a particle deposits energy into one of these detectors, electrons are released and drifted into a gaseous region of high electric field. In the gas, the electrons are accelerated to produce extra light into what is called an S2 pulse. This light is far easier to detect than the current induced from a single electron. The two widely used elements for noble liquid detectors are Xe and Ar. Xe has a larger chance of being hit by neutrinos or dark matter, but ends with a lower (i.e. harder to detect) energy when struck. However, Ar light is hard to reflect and detect due to its short wavelength which is absorbed by most materials. While one may use TPB to re-emit this light at a longer wavelength, spatial variations of TPB thickness can smear the amount of re-emitted light, and thus cause a poor S2 energy resolution and spatial resolution. Furthermore, a single electron pulse in Ar is spread over a much longer time than one in Xe, which makes it harder to identify single electrons in Ar. The goal of Xe doping is to combine the best aspects of Ar with the best aspects of Xe. More specifically, this means a detector with a larger yield of photons and electrons produced per energy deposition, an ability to collect more of the light given by those signals, and a narrower pulse from the electron signal. During this project, we developed and operated a detector that can overcome the thermodynamic challenges of Xe doping – namely, preventing Xe from freezing. In the first experimental run during this award period, we found that we can achieve at least 5% of Xe in LAr, and measure the Xe concentration in the gas. In the second run, we installed our detector and saw the first S2 pulses in a dual phase Xe doped LAr TPC. With the data we took, we quantified the effect of Xe doping on the detectability of wavelength-shifted light produced in a Xe doped Ar mixture, as well as the single electron pulse shape. While the Ar light has successfully been wavelength shifted, we learned that much to our surprise, Xe doping actually makes the S2 pulse wider before it makes it narrower.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Expected tracking performance of the ATLAS Inner Tracker at the High-Luminosity LHC

The high-luminosity phase of LHC operations (HL-LHC), will feature a large increase in simultaneous proton-proton interactions per bunch crossing up to 200, compared with a typical leveling target of 64 in Run 3. Such an increase will create a very challenging environment in which to perform charged particle trajectory reconstruction, a task crucial for the success of the ATLAS physics program, and will exceed the capabilities of the current ATLAS Inner Detector (ID). A new all-silicon Inner Tracker (ITk) will replace the current ID in time for the start of the HL-LHC. To ensure successful use of the ITk capabilities in Run 4 and beyond, the ATLAS tracking software has been successfully adapted to achieve state-of-the-art track reconstruction in challenging high-luminosity conditions with the ITk detector. This paper presents the expected tracking performance of the ATLAS ITk based on the latest available developments since the ITk technical design reports.

47 OTHER INSTRUMENTATION

Development of an In Situ Fission Gas Release Instrument for Fuel Sample Irradiations in the High Flux Isotope Reactor

Experimental measurement of gaseous fission product release with respect to temperature and burnup is a critical aspect of understanding nuclear fuel performance, validating predictive models, and qualifying new fuels. To measure this phenomenon in real-time, Oak Ridge National Laboratory has developed an instrument for measuring in situ fission gas release from small-scale fuel samples irradiated in the High Flux Isotope Reactor (HFIR). The instrument uses a continuous flow of Heover the fuel samples to sweep gaseous fission products from a sealed capsule in the HFIR Be reflector to an instrument station adjacent to the reactor. The instrument station houses two high-purity germanium (HPGe) detectors that measure decay gamma rays from fission products passing through a room temperature dwell chamber placed over the detector crystal. The sealed capsules in the reactor are designed to modulate fuel sample temperatures between 700 and 1,100°C by changing the Ar/He gas mixture surrounding the capsules during irradiation. N-type thermocouples are incorporated into the capsule housing to record real-time fuel temperatures. The capsules are heated primarily by prompt gamma rays emitted from the HFIR core with minimal heat contributions from fission in the fuel samples to minimize temperature gradients in the specimens for separate-effects characterization of the material. This paper describes modeling of time-dependent nuclear heating and fission product formation in fuel samples, thermal characteristics of the in-core capsules, and expected gaseous fission product gamma spectra at the HPGe instrument station.

Mulligan, Padhraic L [ORNL] (ORCID:000000025826540

Correcting beam space charge effects in Active-Target Time Projection Chamber

By providing a large gaseous volume for nuclear interactions while simultaneously recording the tracks of resulting reaction products, an active target serves as both a thick target and a detector. Once a reaction occurs, the emitted charged fragments strip electrons from the target gas along their path as they transverse the detector. Collection of these stripped electrons allow for detection of the product tracks. As beam intensity increases, the resulting ionization in the active target can significantly distort this collection of electrons. If left uncorrected, the resulting measurements could be wrong. In this paper, we investigate the impact of the space charge produced by heavy radioactive beams within the Active Target - Time Projection Chamber at Michigan State University. The beams are injected parallel to the electric field of the time projection chamber which is operated without a magnetic field for this experiment. Furthermore, we analyze the rate dependence of the space charge effects and demonstrate that they can be modeled and effectively corrected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Flow and thermal modelling of the argon volume in the DarkSide-20k TPC

The DarkSide-20k dark matter experiment, currently under construction at LNGS, features a dual-phase time projection chamber (TPC) with a ∼ 50 t argon target from an underground well. At this scale, it is crucial to optimise the argon flow pattern for efficient target purification and for fast distribution of internal gaseous calibration sources with lifetimes of the order of hours. To this end, we have performed computational fluid dynamics simulations and heat transfer calculations. The residence time distribution shows that the detector is well-mixed on time-scales of the turnover time (∼ 40 d). Notably, simulations show that despite a two-order-of-magnitude difference between the turnover time and the half-life of 83m Kr of 1.83 h, source atoms have the highest probability to reach the centre of the TPC 13 min after their injection, allowing for a homogeneous distribution before undergoing radioactive decay. We further analyse the thermal aspects of dual-phase operation and define the requirements for the formation of a stable gas pocket on top of the liquid. We find a best-estimate value for the heat transfer rate at the liquid-gas interface of 62 W with an upper limit of 144 W and a minimum gas pocket inlet temperature of 89 K to avoid condensation on the acrylic anode. This study also informs the placement of liquid inlets and outlets in the TPC. The presented techniques are widely applicable to other large-scale, noble-liquid detectors.

47 OTHER INSTRUMENTATION

Spatially and temporally resolved plasma parameter estimations of laser heated MagLIF relevant gas pipes at NIF

The ability to control laser pre-heat is an integral part of the inertial confinement fusion concept known as Magnetized Liner Inertial Fusion. This process is studied at the National Ignition Facility (NIF) where 4 of the 192 laser beams are propagated through a 1-cm long gas cell where they deposit >20 kJ of energy into the gaseous fuel via inverse bremsstrahlung absorption. This process ionizes the gas, producing a plasma that follows behind the laser front and expands over the radius of the cell. Emission from this plasma, as viewed by a gated x-ray detector, can be used to build spatially and temporally resolved estimations of the pre-heat plasma's density and temperature profiles. This can then be used to estimate the plasma pressure, internal energy, and radiation losses. Estimations show the evolution of the plasma in magnetized and unmagnetized gas cells filled with ambient temperature neopentane (C5H12) +1% Ar, as well as unmagnetized cryogenically cooled (32 K) deuterium +1% Ne filled targets. This analysis shows the effects of initial gas-fill density, composition, and axial magnetization on the time-dependent plasma parameters. Previously, these parameters at the NIF had not been experimentally characterized, and these estimations provided a potential new means of testing radiation magneto-hydrodynamic predictive capability models. Results in unmagnetized targets have strong agreement with simulations. However, in targets with a 19 T applied axial magnetic field, this method yields electron temperatures up to 100% hotter than those predicted by HYDRA codes.

Bremsstrahlung

Measurement of the mean excitation energy of liquid argon

The mean excitation energy (I-value) of liquid argon is a critical input for energy estimation in neutrino oscillation experiments. It is measured to be 199 +4 -5 eV using the range of 402.2 MeV protons from the Fermilab Linac. This compares to the author's recent evaluation of (197 ± 7) eV based on a combination of an oscillator strength distribution analysis, gaseous argon range measurements, sparse stopping power data on solid argon, and an extrapolation of data on the effect of phase from other substances. Using all sources of information, we recommend a value of (198 ± 4) eV for liquid argon, which is significantly higher than 188 eV, from ICRU-37's gaseous argon evaluation, commonly used in Monte Carlo codes such as Geant4.

47 OTHER INSTRUMENTATION

FGMS-poster

Idaho National Laboratory (INL) performs post irradiation examination (PIE) of tri-structural isotropic (TRISO)-coated particle fuel to help qualify it for high temperature gas cooled reactors. TRISO fuel compacts are re-irradiated in the Neutron Radiography Reactor (NRAD) to generate the short lived fission products needed for fission product release testing. The Fuel Accident Condition Simulator (FACS) furnace and newly added Screen Neutron Irradiated Fuel for Failure (SNIFF) furnace heat the compacts in helium to temperatures of up to 2,000°C, prompting fission product release—predominantly gaseous xenon and krypton isotopes and condensable products such as cesium—from failed particles. These released isotopes are transported to a fission gas monitoring system (FGMS 1 or FGMS 3), where they accumulate in cryogenic cold traps and are quantified using high-purity germanium (HPGe) detectors. The addition of SNIFF and FGMS 3 increases throughput by enabling simultaneous testing of multiple compacts. Furthermore, automated INL developed software provides continuous, near-real time monitoring of fission product inventories and manages the liquid nitrogen cooling of the traps. These system enhancements improve the efficiency, data quality, and testing capacity of TRISO fuel performance evaluations.

07 - ISOTOPES AND RADIATION SOURCES

JENSA: Past, present, and future

Nuclear reaction studies rely on three main physical components: the beam of nuclei provided by the facility, the detector systems used to measure the outgoing particles of interest, and the target. Target fabrication is thus a critical aspect of studying the reactions that power stars and probe the evolution of nuclear structure. The Jet Experiments in Nuclear Structure and Astrophysics (JENSA) gas jet target is the most dense helium jet target for rare isotope beam reaction studies in the world, providing targets of gaseous elements such as helium, nitrogen, and neon. A brief overview of the design and operation of JENSA, including commissioning and recent science experiments, and a discussion the future of JENSA coupled to the dedicated recoil separator SECAR, are presented.

Chipps, Kelly [ORNL] (ORCID:0000000330501298)

FPMS_XPeRT_INL_Poster

As nuclear energy expands and experimental programs increasingly rely on the facilities at Idaho National Laboratory (INL) for reactor and fuel testing, research capabilities must also expand to meet these demands. A new Fission Product Monitoring System (FPMS) has been deployed at the Advanced Test Reactor (ATR) at the Auxiliary Lead-out Experiment (ALE) House to support this expanding fuel testing mission. By tracking gaseous fission products releases from test fuel in near real-time, release rates, calculated from FPMS data, can be used to characterize the effectiveness of fuel cladding, especially for Tri-structural Isotropic (TRISO) fuel concepts. The new iteration of the FPMS supports up to 14 fission product monitors for online fission-product tracking via gamma-ray spectroscopy of the experiment’s effluent gas. Each monitor consists of a nominally 10% HPGe detector housed in a copper-lined lead shield with a warm gas trap. The new system features gamma-ray count rate information with a five-second temporal resolution and provides isotopic activity every five minutes, capable of resolving multiple overlapping fission product releases over a broad range of activities in near real-time. This work includes data from ATR cycle 175D data to demonstrate these capabilities. The hourly resolution data shows general trends and significant releases over the cycle, while the 5-minute resolution data allows for a more detailed examination of events due to unexpected particle releases.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN