Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gas tracking detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ariel 6 measurements of ultra-heavy cosmic ray fluxes in the region 34 or = Z or = 48

The Ariel VI satellite was launched by NASA on a Scout rocket on 3rd June 1979 from Wallops Island, Virginia, USA, into a near circular 625 km orbit inclined at 55 deg. It carried a spherical cosmic ray detector designed by a group from Bristol University. A spherical aluminum vessel of diameter 75 cm contains a gas scintillation mixture and a thin spherical shell of Pilot 425 plastic, and forms a single optical cavity viewed by 16 photomultipliers. Particle tracks through the detector may be characterized by their impact parameter p and by whether or not they pass through the cup of plastic scintillator placed between the sphere and the spacecraft body (referred to below as the Anti-Coincidence Detector or ACD). Individual particle charges are determined by separately measuring the gas scintillation and the Cerenkov emission from the plastic shell. This is possible because of the quite different distribution in time of these emissions.

Fowler, P. H.↗

Fast spark-detection system for GEM detectors

The sPHENIX experiment is currently under commissioning at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Lab (BNL). The Time Projection Chamber (TPC) serves as a tracking detector for the experiment. The sPHENIX TPC uses a stack of four Gas Electron Multipliers (GEMs) as a gain stage in a reduced ion back-flow configuration. To mitigate the damaging effects of sparks in the GEMs, an online spark monitoring system was created. Once the system detects a spark in a GEM stack, the voltages across the GEMs in that stack can be lowered to prevent further sparking without affecting the gain and efficiency of the other modules. Spark signals are coupled out of the GEM stack by a pick-off capacitor attached to the bottom of the bottom GEM. Custom PCBs convert the oscillatory spark signal into a mono-polar pulse that is then digitized. The software then saves the waveform in a server and uses experimentally derived thresholds to determine how to react. As a result, the system has so far proven to be effective at improving the stability of the TPC and preventing damaging events while collecting cosmic ray data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GEMS X-ray Polarimeter Performance Simulations

The Gravity and Extreme Magnetism Small explorer (GEMS) is an X-ray polarization telescope selected as a NASA small explorer satellite mission. The X-ray Polarimeter on GEMS uses a Time Projection Chamber gas proportional counter to measure the polarization of astrophysical X-rays in the 2-10 keV band by sensing the direction of the track of the primary photoelectron excited by the incident X-ray. We have simulated the expected sensitivity of the polarimeter to polarized X-rays. We use the simulation package Penelope to model the physics of the interaction of the initial photoelectron with the detector gas and to determine the distribution of charge deposited in the detector volume. We then model the charge diffusion in the detector,and produce simulated track images. Within the track reconstruction algorithm we apply cuts on the track shape and focus on the initial photoelectron direction in order to maximize the overall sensitivity of the instrument, using this technique we have predicted instrument modulation factors nu(sub 100) for 100% polarized X-rays ranging from 10% to over 60% across the 2-10 keV X-ray band. We also discuss the simulation program used to develop and model some of the algorithms used for triggering, and energy measurement of events in the polarimeter.

Baumgartner, Wayne H.↗

Performance of the Three-Dimensional Track Imager (3-DTI) for Gamma-Ray Telescopes

We have been developing a gas time projection chamber for the imaging of gamma-rays between 0.3 - 50 MeV, the Three-Dimensional Track Imager (3DTI). The detector is being designed for use on satellite experiments for the imaging of astrophysical gamma-ray sources. Electrons produced by pair production or Compton scattering ionize the gas and these ionization electrons are detected by the cross-strip micro-well detector at the bottom of the chamber. Discrete component of front end electronics and time digitization electronics have been developed. We will present results of prototype microwell detector and laboratory set-up in various gas mixtures.

Son, Seunghee↗

Avalanche gain and its effect on energy resolution in GEM-based detectors

Here, we present avalanche gain and associated resolution measurements recorded with a 4 He:CO 2 (70:30) gas mixture and pure SF 6 , a Negative Ion (NI) gas. SF 6 is of particular interest to the directional dark matter detection community, as its low thermal diffusion helps to retain recoil ionization track features over long drift lengths. With the aid of a general form of the reduced first Townsend coefficient (RFTC), multiple GEM-based detector data sets are used to study the high-gain behavior of the 4 He:CO 2 gas mixture. The high-gain data is well described purely in terms of the reduced electric field strength and the number of GEMs, and the robust relationship between the RFTC and the average, reduced, electric field strength across the GEMs is emphasized. The associated (pulse-height) resolution measurements are used to discuss the variance of the avalanche distribution and to describe and estimate the lower limits of energy resolution one should expect to measure using a simple relationship with the RFTC. In the end, a description of avalanche gain, its effect on energy resolution, and the contributing experimental parameters in GEM-based detectors is developed over a broad parameter space for further use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPY: a conceptual design study of a magnet system for a high-pressure gaseous TPC neutrino detector

Here, we present a novel conceptual design for a magnet system that provides the magnetic field necessary for the analysis of tracks in a high-pressure gaseous argon TPC while simultaneously serving as a pressure vessel to contain the TPC gas volume. The magnet was developed within a Near Detector proposal for the Deep Underground Neutrino Experiment (DUNE). The high-pressure gaseous argon TPC is a component proposed to be one of the elements of an ensemble of near detectors that are needed for DUNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Measurement of the Neutron Electric Form Factor with the Super Bigbite Spectrometer Apparatus

Protons and neutrons, collectively known as nucleons, make up the nuclei at the core of atoms which form our world. The nucleon has been under intensive study for over 100 years, and yet we still do not fully understand the internal dynamics which govern properties like its spin or its mass-which contributes to almost all of the visible mass in the universe. These dynamics are governed by quantum chromodynamics(QCD), the predictions of which are experimentally tested at high energy accelerator facilities such as Jefferson Lab. TheGEN-II experiment (E12-09-016) is one such experiment. GEN-II is part of the Super Bigbite Spectrometer (SBS) experimental form factor pro gramme taking place in Hall A at Jefferson Lab, which aims to make precision measurements of the nucleon electromagnetic form factors(EMFFs)at record high values of squared four momentum transfer ¿2. EMFFs describe the electric and magnetic moment distributions within the nucleon. They can be measured through elastic electron scattering off the nucleon, and describe the recoil response of the target nucleon at a given energy scale. GEN-II is a double polarized semi-exclusive beam target asymmetry (BTA) experiment, seeking to measure the electric form factor of the neutron,¿¿ ¿,at three new values of squared four-momentum transfer¿2 =2.92,6.74and9.82GeV². The latter two points being at record high ¿2. The form factor is determined through measuring the BTA of quasielliptical scattering of a neutron from a polarized nuclear target. The experiment utilized the CEBAF accelerator to produce longitudinally polarized electrons up to ~85% polarization, which were scattered off neutrons within a novel polarized helium-3 (³He) target. This new polarized ³He target was employed by building on the technology of its precursors which existed in similar preceding experiments. This target was designed to operate at the high luminosities typical of Hall A, and reached a record breaking combination of polarization and beam intensity known as figure of merit, three times larger than those predecessors. The SBS collaboration designed and constructed two brand new high acceptance spectrometers for these experiments, an electron arm named Bigbite (BB) and a hadron arm named Super Bigbite. Both spectrometers featured a large acceptance EM dipole magnet, and complementary detector systems. The electron arm contained gaseous electronmultipliers(GEMs) which were used for high precision tracking of the scattered electrons, a heavy gas cherenkov (GRINCH) which was used for PID between electrons and pions, a plastic i ii scintillator timing hodoscope to provide high resolution timing of the start of events, and a pair of EM calorimeters (BBCal) which provided energy measurements of detected particles, and provided the experimental trigger. The hadron arm also contained a system of GEMs which will be utilized for future SBS experiments, and a hadron calorimeter designed to provide position, timing and energy measurements of the recoiling nucleon. The calibration of all detector subsystems, beam and target data is discussed, with a focus on novel timing calibrations to the hodoscope and hadron calorimeter. An analysis of selecting quasielliptical events and suppressing background contributions from a number of sources which contaminate the final event sample is given. The largest irreducible backgrounds are found to be from misidentified protons, timing accidentals and inelastic events. The physical asymmetry is measured and used to extract a value for the form factor ratio ¿¿ ¿/¿¿ ¿. High precision ¿2 data for ¿¿ ¿ is used to then extract ¿¿ ¿. This work finds at ¿2 = 2.92 GeV2 that ¿¿ ¿ = 0.0129+0.0019 -0.0020. This result is in statistical agreement with existing fits to world data, and predictions from the constituent quark model and Dyson–Schwinger equations, in this region of ¿2.

Penman, Gary [Univ. of Glasgow, Scotland (United K↗

Ion tracking in an electrostatic potential distribution

An ion tracking system utilizing a single detector was designed to resolve two dimensional potential distributions in a vacuum. The ion detector consisted of a continuous dynode electron multiplier tube mounted behind a series of aperture plates. The detector was located on a track below a wedge shaped structure used to produce the desired potential distribution. A 150 volt electron beam aimed at selected regions, ionized the residual gas in the chamber. The ions were ejected from their source points by electrostatic forces causing them to drift downward toward the detector. Measurements of particle energy, detector position, and entry angle of the incoming particle flux were used to initialize a computer trajectory-tracing program. The program assumes a known theoretically calculated potential distribution near the wedge for computation of particle trajectories, providing a basis for evaluating the data. Special attention was given to characterization of the ion detector.

Ross, D. P.↗

Potential absence of observed π2 linear-chain structures in 14O via 10C(α,α) resonances scattering

Background: The preference for light nuclear systems to coagulate into -particle clusters has been well-studied. The possibility of a linear chain configuration of -particles would allow for a new way to study this phenomenon. Purpose: A rotational band of states in C has been claimed showing a linear chain structure. The mirror system, O, has been studied here to examine how this linear chain structure is affected by replacing the valence neutrons with protons. Method: A beam of C was incident into a chamber filled with He:CO gas with the tracks recorded inside the TexAT Time Projection Chamber and the recoil -particles detected by a silicon detector array to measure the cross section. Results: The experimental cross section was compared with previous studies and fit using R-Matrix theory with the previously-observed O states being transformed to the C using mirror symmetry. The measured cross section does not replicate the claimed states, with the predicted cross section exceeding that observed at several energies and angles. Conclusion: A series of possibilities are highlighted with the most likely being that the originally-seen C states did not constitute a rotational band with a potentially incorrect spin assignment due to the limitations of the angular correlation method with non-zero spin particles. The work highlights the difficulties in measuring broad resonances corresponding to a linear chain state in a high level density.

Bishop, J.↗

FPMS_XPeRT_INL_Poster

As nuclear energy expands and experimental programs increasingly rely on the facilities at Idaho National Laboratory (INL) for reactor and fuel testing, research capabilities must also expand to meet these demands. A new Fission Product Monitoring System (FPMS) has been deployed at the Advanced Test Reactor (ATR) at the Auxiliary Lead-out Experiment (ALE) House to support this expanding fuel testing mission. By tracking gaseous fission products releases from test fuel in near real-time, release rates, calculated from FPMS data, can be used to characterize the effectiveness of fuel cladding, especially for Tri-structural Isotropic (TRISO) fuel concepts. The new iteration of the FPMS supports up to 14 fission product monitors for online fission-product tracking via gamma-ray spectroscopy of the experiment’s effluent gas. Each monitor consists of a nominally 10% HPGe detector housed in a copper-lined lead shield with a warm gas trap. The new system features gamma-ray count rate information with a five-second temporal resolution and provides isotopic activity every five minutes, capable of resolving multiple overlapping fission product releases over a broad range of activities in near real-time. This work includes data from ATR cycle 175D data to demonstrate these capabilities. The hourly resolution data shows general trends and significant releases over the cycle, while the 5-minute resolution data allows for a more detailed examination of events due to unexpected particle releases.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

NEXT-CRAB-0: a high pressure gaseous xenon time projection chamber with a direct VUV camera based readout

The search for neutrinoless double beta decay(0νββ) remains one of the most compelling experimentalavenues for the discovery in the neutrino sector.Electroluminescent gas-phase time projection chambers are wellsuited to 0νββ searches due to their intrinsicallyprecise energy resolution and topological event identificationcapabilities. Scalability to ton- and multi-ton masses requiresreadout of large-area electroluminescent regions with fine spatialresolution, low radiogenic backgrounds, and a scalable dataacquisition system. This paper presents a detector prototype thatrecords event topology in an electroluminescent xenon gas TPC viaVUV image-intensified cameras. This enables an extendable readoutof large tracking planes with commercial devices that reside almostentirely outside of the active medium. Following furtherdevelopment in intermediate scale demonstrators, this technique mayrepresent a novel and enlargeable method for topological eventimaging in 0νββ.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DRiFT - Release 2.1.0: Organic Scintillators and Gas Detectors

DRiFT (a Detector Response Function Toolkit) is LANL-developed software that post-processes output from the extensively validated radiation transport code, MCNP, and generates realistic nuclear instrumentation response. DRiFT is designed to be flexible, enabling users to specify detector type and many experimental settings, as well as accommodating the addition of their own desired features. The focus of this release is on organic scintillator, gas detector, and associated capabilities, while semiconductor features are still under development. Organic scintillators are widely used in the areas of nuclear safeguards and nuclear non-proliferation efforts. DRiFT has several diagnostic and detector physics features relevant to detailed scintillator simulations including: tracking source particle information, scintillation light production, the effects of PMT quantum efficiency and gain, and digitizer settings. Users can select responses from many scintillator and PMT types supported natively by DRiFT, or add their own by following the instructions in this document. DRiFT also has several diagnostic and detector physics features relevant to neutron gas detector simulations including: gas detector wall effects, inactive areas at the end of detector tubes, and effects of a preamplifier. We acknowledge that DRiFT is under active development, bug reports and general questions and comments should be directed to Madison Andrews, madison@lanl.gov. This manual is divided into four parts: I) An overview of DRiFT, including how to obtain and install the executable, II) A description of the detector physics related to scintillators available, III) a description of more general DRiFT features the user may find useful, and IV) a description of the test suite and examples made available with the code release.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the CMS detector for the CERN LHC Run 3

Since the initial data taking of the CERN LHC, the CMSexperiment has undergone substantial upgrades and improvements. Thispaper discusses the CMS detector as it is configured for the thirddata-taking period of the CERN LHC, Run 3, which started in2022. The entire silicon pixel tracking detector was replaced. A newpowering system for the superconducting solenoid was installed. Theelectronics of the hadron calorimeter was upgraded. All the muonelectronic systems were upgraded, and new muon detector stationswere added, including a gas electron multiplier detector. Theprecision proton spectrometer was upgraded. The dedicated luminositydetectors and the beam loss monitor were refurbished. Substantialimprovements to the trigger, data acquisition, software, andcomputing systems were also implemented, including a new hybridCPU/GPU farm for the high-level trigger.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Muon tracking in a LiquidO opaque scintillator detector

LiquidO is an innovative radiation detector concept. The core idea is to exploit stochastic light confinement in a highly scattering medium to self-segment the detector volume. In this paper, we demonstrate event-by-event muon tracking in a LiquidO opaque scintillator detector prototype. The detector consists of a 30 mm cubic scintillator volume instrumented with 64 wavelength-shifting fibres arranged in an 8 × 8 grid with a 3.2 mm pitch and read out by silicon photomultipliers. A wax-based opaque scintillator with a scattering length of approximately 0.5 mm is used. The tracking performance of this LiquidO detector is characterised with cosmic-ray muons and the position resolution is demonstrated to be 450 μm per row of fibres. These results highlight the potential of LiquidO opaque scintillator detectors to achieve fine spatial resolution, enabling precise particle tracking and imaging.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of recoil-imaging time projection chambers to directional neutron background measurements in the SuperKEKB accelerator tunnel

Gaseous time projection chambers (TPCs) with high readout segmentation are capable of reconstructing detailed 3D ionization distributions of nuclear recoils resulting from elastic neutron scattering. Here, using a system of six compact TPCs with pixel ASIC readout, filled with a 70:30 mixture of He:CO 2 gas, we analyze the first directional measurements of beam-induced neutron backgrounds in the tunnel regions surrounding the Belle II detector at the SuperKEKB e + e – collider. With the use of 3D recoil tracking, we show that these TPCs are capable of maintaining nearly 100% nuclear recoil purity to reconstructed ionization energies (E reco ) as low as 5 keV ee . Using a large sample of Monte-Carlo (MC)-simulated 4 He, 12 C, and 16 O recoil tracks, we find consistency between predicted and measured recoil energy spectra in five of the six TPCs, providing useful validation of the neutron production mechanisms modeled in simulation. Restricting this sample to 4 He recoil tracks with E reco > 40 keV ee , we further demonstrate axial angular resolutions within 8° and we introduce a procedure that under suitable conditions, correctly assigns the vector direction to 91% of these simulated 4 He recoils. Applying this procedure to assign vector directions to measured 4 He recoil tracks, we observe consistency between the angular distributions of observed and simulated recoils, providing first experimental evidence of localized neutron “hotspots” in the accelerator tunnel. Observed rates of nuclear recoils in these TPCs suggest that simulation overestimates the neutron flux from these hotspots. Despite this, we estimate these hotspots to produce the majority of neutron backgrounds in the accelerator tunnel at SuperKEKB’s target luminosity of 6.3 x 10 35 cm –2 s –1 , making them important regions to continue to monitor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Astro-D Prelaunch Mission Operation Report (MOR)

The Prelaunch Mission Operation Report for the Astro-D mission is enclosed for your information. Astro-D is a Japanese-led program involving the United States as a participating partner. The Japanese Institute of Space and Astronautical Science (ISAS) provides overall program management, the launch vehicle, the spacecraft, and two Gas Scintillation Imaging System detectors. NASA is providing four nested, thin-foil, grazing-incidence telescope mirrors and two X-ray charged-coupled device solid-state detectors. NASA also provides telemetry tracking support using Deep Space Network ground stations. In return for its scientific instrument contribution, the U.S. will receive 15 percent of the observing time and will share an additional 25 percent for collaborative U.S./Japan scientific investigations. Launch is scheduled for mid- February 1993 from the ISAS launch center near Kagoshima in southern Japan. This MOR: (a) describes the NASA objectives for the Astro-D mission; (b) provides brief descriptions of the spacecraft and its scientific instruments; (c) provides a chronology of launch and deployment; and (d) describes the ground operation elements that support the mission. .

Source record↗

MOPITT - A gas correlation spectrometer for tropospheric Earth observations

MOPITT (Measurement of Pollution in the Troposphere) is an instrument that will fly on the EOS AM-1 Polar Orbiting Platform, to be launched in mid-1998. The instrument accurately measures the concentration of carbon monoxide (CO) and methane (CH4) gas in the troposphere, using novel and conventional gas correlation spectroscopy techniques. These techniques are used to measure both the column amount and the vertical profile of the two gases in the troposphere. The instrument is nadir viewing and has cross-track scanning ability. It measures upwelling IR radiation through the atmosphere in the 4.6-micron and 2.3-micron bands for CO detection, and 2.2-micron for CH4. The instrument performance is enhanced using Stirling cycle mechanical coolers to maintain the IR detectors at less than 100 K. MOPITT has a total of eight detector channels to measure the total column of atmospheric CH4 gas to a precision of 1 percent, and to measure CO profiles to a precision of 10 percent. The instrument is self-calibrating to ensure data validity using internal targets and an external cold space view.

Drummond, James R.↗

Use of dew-point detection for quantitative measurement of sweating rate

A method of measuring sweat rate (SR) based on detection of dew point (DP) is proposed which has advantages that may be attractive to other laboratories concerned with recording SR from selected areas of skin. It is similar to other methods in that dry gas is passed through a capsule which isolates several square centimeters of skin surface. The difference is in the means of determining how much gaseous water is carried off in the effluent moist gas. The DP detector used is free of the drawbacks of previous devices. DP is obtained through the fundamental technique of determining the temperature at which condensate forms on a mirror. Variations in DP are tracked rapidly, and accurately (+ or - 0.8 C nominal, sensitivity + or - 0.05 C) over a wide range ( -40 C to +50 C) without measurable hysteresis. The detector asembly is rugged and readily opened for cleaning and inspection.

Brengelmann, G. L.↗