Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GODIVA IV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Godiva-IV Dosimetry Exercise 2022 Preliminary Results

Integral Experiment Request (IER) 538 is part of a series of dose characterization and nuclear accident dosimetry (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). This is the second NAD exercise using the Godiva-IV critical assembly and the third NAD exercise overall. The participating laboratories provided their own dosimeters that were mounted on the Lawrence Livermore National Laboratory (LLNL) BOttle Manikin ABsorption (BOMAB) phantoms and aluminum plates. The BOMABs and plates were placed at two, three, and four meters away from the center of Godiva. Alongside the NADs, there was a LLNL Passive Neutron Spectrometer (PNS), Atomic Weapons Establishment (AWE) PNS, and Y-12 Sphere present to measure the neutron dose from Godiva. Two irradiations were conducted to test the NAD performance from each laboratory and assesses their performance to the DOE-STD-1098-2017 part 515 criteria. Neutron and gamma doses were measured prior to this exercise. This work presents a model for the neutron and gamma dose respectively to serve as the reference value. A code written in C/C++/ROOT was used to fit the measured neutron and gamma dose with the new models. It was assumed that the neutron and gamma doses are proportional to the change in temperature of Godiva after a burst irradiation. Uncertainties for the reference values were calculated using error propagation of the model’s parameters. Preliminary results (within twenty-four hours) and final results were compared for each laboratory. On average of all the participating laboratories, 32% of neutron doses and 78% of gamma doses were outside the DOE standards. One laboratory did not report their dose readings and were not included in this average. There is a bias for a lower neutron dose and a higher gamma dose based on the distribution of results. In comparison with the past Godiva-IV NAD exercise, there is an improvement in neutron dose readings by 20%.

BOttle Manikin ABsorption (BOMAB)↗

IER 557: Godiva IV Reproducibility/Characterization [Slides]

The primary goal of the IER 557 Godiva IV reproducibility/characterization process is to determine reproducibility for 70°C bursts. The secondary goal is to characterize the radiation field, including absolute calibration with radchem counting of fission foils.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IER 538: International Dosimetry Intercomparison Exercise with Godiva-IV [Slides]

Presentation on International Dosimetry Intercomparison Exercise with Godiva-IV. This presentation details Department of Energy (DOE) requirements and irradiation. Graphs show Neutron dose conversion factors, Neutron dose characterization, and Photon dose characterization. Results of 2m, 3m, and 4m tests are then compared to DOE standards. Findings show photon dose measurements were limited by instrumentation not available. Additionally, there has been a turnover of staff in dosimetry. However, funding is being provided for Universal Nuclear Accident Dosimeter (U-NAD).

61 RADIATION PROTECTION AND DOSIMETRY↗

Godiva-IV Critical Assembly [Slides]

The objectives of this presentation are to: (1) gain awareness of the Godiva-IV assembly, including its design and intent; (2) create familiarization of the differences between subcritical, delayed-critical, and prompt-critical; and (3) observe the effects of temperature-dependent reactivity feedback.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experiment Logistics for an International Blind Intercomparison Exercise for Nuclear Accident Dosimetry at Godiva-IV

This document is the Experimental Set-up and Design (CED-3A) Report for IER-538, “Full Dosimetry Exercise Around Godiva Reactors” The report discusses the structure of the exercise consisting of two critical excursions, identifying the participating laboratories and their points of contact. The report also includes details of all dosimetry each laboratory will submit to be placed in proximity to Godiva-IV on aluminum plates or BOMAB phantoms. Each laboratory list the counting and spectroscopy equipment to be utilized at the LLNL NAD Laboratory in Mercury. The exercise is tentatively scheduled for one week in fiscal year 2022.

61 RADIATION PROTECTION AND DOSIMETRY↗

Godiva IV Shielding Benchmark Overview [Slides]

This presentation shows that Integral experiments increase the level of realism from that of data measurements. Further, Godiva IV is capable of intensities to activate foils. IER 498 uses a relative measurement to provide an intermediate level of realism. With reproducibility and room return management are key components. The test matrix put forward in CED-2 enables numerous cross-comparisons. IER 498 facilitates various additional works using a room return shield to isolate the source. IER 557 demonstrated burst reproducibility sufficient for IER 498.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Godiva-IV Dosimetry Exercise 2022 (IER-538 CED4A Report)

This report presents the final results of IER 538, The International Nuclear Accident Dosimeter (NAD) Intercomparison Exercise with Godiva-IV. The purpose of the exercise, held in August of 2022, was to test participants’ NADs and dosimetry personnel to the dose estimation requirements established by ANSI/HPS-N13.3 Dosimetry for Criticality Accidents and DOE-STD-1098-2017, Radiological Control. Two prompt critical bursts of the Godiva critical assembly were used to simulate criticality accidents, and NADs from participating laboratories were placed at known locations around Godiva, mounted on either BOttle Manikin ABsorptions (BOMABs) phantoms (to simulate doses received by people) or plates (to simulate doses in free air). Similar exercises have been held in 2016 and 2018 using National Criticality Experiments Research Center’s (NCERC’s) Flattop and Godiva assemblies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Characterization Summary: Godiva IV Critical Assembly Environments at the In-Core, Top Hat, 1m, and 2m Irradiation Locations

This document presents the facility-recommended characterization of the neutron, prompt gamma ray, and delayed gamma ray radiation fields at the Godiva IV critical assembly at the National Criticality Experiments Research Center (NCERC). The environments assessed include the In-Core location, a location on the Top Hat, 1m away from the assembly, and 2m away from the assembly. The neutron, prompt gamma ray, and delayed gamma ray energy spectra, uncertainties, and covariance matrices are presented as well as radial and axial neutron and gamma ray fluence profiles on the Top Hat surrounding the critical assembly. Recommended constants are given to facilitate the conversion of various dosimetry readings into radiation metrics desired by experimenters. Representative pulse operations are presented with conversion examples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

237 Np Fission Spectrum Cumulative Fission Product Yield Measurement Using Godiva IV Critical Assembly

Precise integral measurement of fast neutron-induced fission product yields for various actinides is of high interest for applied nuclear science. The goal of this effort is to improve uncertainties in fission product yield values of 237 Np. Fission was induced in a NpO 2 (NO 3 ) target using the Godiva IV critical assembly in burst mode. The irradiated sample was transferred to a high-resolution γ-ray detection setup within 50 minutes. γ-ray list mode data was collected from 50 minutes to 1 week after the irradiation. γ-ray spectroscopy was performed to analyze the time dependent γ-ray yields using an automated peak search algorithm to identify isotopes by their decay γ-ray energy and half-life. Finally, the initial activity for each isotope identified was used to calculate their fission product yield.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

239 Pu Fission Spectrum Cumulative Fission Product Yield Measurement Using Godiva IV Critical Assembly

Precise integral measurement of fast neutron-induced fission product yields for various actinides is of high interest for applied nuclear science. The goal of this effort is to improve uncertainties in fission product yield values of 239 Pu. Fission was induced in a pure 239 Pu (>99%) target using the Godiva IV critical assembly in burst mode. Further, the irradiated sample was transferred to a high-resolution γ-ray detector within 45 minutes. γ-ray list mode data was collected from 45 minutes to 1 week after the irradiation. γ-ray spectroscopy was performed to analyze the time dependent γ-ray yields using an automated peak search algorithm to identify isotopes by their decay γ-ray energy and half-life. The initial activity for each isotope identified was used to calculate their fission product yield.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CAAS-3S Radiation Testing for Y-12 and UPF with Godiva-IV

The Y-12 National Security Complex and the Uranium Processing Facility (UPF) selected the Mirion CAAS-3S as the Criticality Accident Alarm System for UPF and for Y-12 facilities replacing their legacy CAAS as part of efforts to extend the facility lifespans. As part of this process, the CAAS-3S system was exposed to a high radiation dose and dose rate during reactor testing with the Godiva-IV fast burst reactor. The reactor testing was designed around preliminary analyses that determined Y-12 and UPF requirements, and simulations of the radiation field within the reactor facility were used to determine reactor operating parameters, CAAS equipment locations, and the design of a neutron shield wall. This paper presents the design and results of the testing, and discusses how the test results were interpreted by criticality safety engineers at Y-12 and UPF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

R-Value Measurements Performed on Actinide Targets Irradiated using the GODIVA IV Critical Assembly in FY22

The separation and characterization of two irradiated uranium targets, a depleted uranium (DU) and a highly enriched uranium (HEU) target as well as a plutonium (Pu) target, was conducted in April of 2022. The three targets were assembled at Los Alamos National Laboratory (LANL) and irradiated using the GODIVA critical assembly at the National Criticality Experiments Research Center (NCERC). Splits of the dissolved targets were received by Pacific Northwest National Laboratory (PNNL) after which the PNNL and LANL teams chemically separated the solutions using independent separation schemes and analyzed the separated fractions for short lived actinides and fission products. Chemical separations were traced with stable or radioactive tracers to allow for the determination of chemical yields, analyzing using either inductively coupled plasma optical emission spectroscopy (ICP-OES), inductively coupled plasma mass spectrometry (ICP-MS) or gamma emission analysis (GEA) depending on the nature of the tracer. The Pu target solution was traced with stable elements at LANL to follow elemental fractionation during a Pu removal step. Many analytical techniques were used by PNNL including kinetic phosphorescence analysis (KPA), ICP-OES, ICP-MS, GEA, and thermal ionization mass spectrometry (TIMS) depending on the analyte’s need.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CAAS-3S Radiation Testing for Y-12 and UPF with Godiva-IV

Goals: 1) Qualify the CAAS-3S system to a mixed-field radiation dose and dose rate, and 2) Extend the Y-12 Shielding MCNP Validation to rad-si. This paper represents the efforts of Y-12 and UPF personnel, and their interpretation of the test results.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗