Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GEONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

33 records · Page 2

Shakeup and shakeoff spectra in the electron capture decay of atomic 7 Be

The most stringent laboratory-based experimental limits on the existence of submegaelectronvolt sterile neutrinos are currently set by decay spectroscopy of radioactive 7 Be embedded into superconducting sensors. The systematic uncertainties are dominated by the modeling of the electron shakeup and shakeoff spectra that are not based on state-of-the-art atomic theory and do not include electron correlations or relativistic effects. We have used the multiconfiguration Dirac-Fock formalism to obtain correlated wave functions ab initio and compute all single and double shake processes in the electron capture decay of atomic 7 Be . The simulations can explain some but not all of the observed spectral features, likely because the wave functions are modified by the Ta sensor material that the 7 Be is embedded into. The new models also show that the 𝐿/𝐾 electron capture ratio of 7 Be in Ta has previously been slightly underestimated revising the previous value of 0.070(7) to a new value of 0.0756(20).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Signal processing and spectral modeling for the BeEST experiment

The Beryllium Electron capture in Superconducting Tunnel junctions (BeEST) experiment searches for evidence of heavy neutrino mass eigenstates in the nuclear electron capture decay of 7 Be by precisely measuring the recoil energy of the 7 Li daughter. In Phase III, the BeEST experiment has been scaled from a singl superconducting tunnel junction (STJ) sensor to a 36-pixel array to increase sensitivity and mitigate gamma-induced backgrounds. Phase III also uses a new continuous data acquisition system that greatly increases the flexibility for signal processing and data cleaning. Here, we have developed procedures for signal processing and spectral fitting that are sufficiently robust to be automated for large datasets. Furthermore, this article presents the optimized procedures before unblinding the majority of the Phase III dataset to search for physics beyond the standard model.

6 ≤ A ≤ 19↗

Development of Fast Decay-Energy Spectroscopy With Magnetic Microcalorimeters

Decay energy spectroscopy (DES) is an increasingly important radiometric technique arising from the unique thermal detection physics and the precision of low-temperature microcalorimetry. DES can enable high-precision analysis of very small amounts of radioactive material with simple and rapid sample preparation, making it a key new tool for nuclear safeguards, nuclear forensics, the improvement of nuclear data, measurements of absolute activity, and other applications. For problems in nuclear safeguards and nuclear forensics it is highly desirable to increase the count rates achievable in DES, while maintaining simple and rapid sample preparation. Here, in this report, we describe progress in a new project to achieve high count rates in DES by taking advantage of the physics of magnetic microcalorimetry. We describe the results of initial modeling and experiment to validate the idea, a sample fabrication technique suitable for nuclear materials laboratories, the preparation and initial tests of paramagnetic Au-Er alloy in thin foil form, and the development of a sensing coil geometry that will perform well with the increased-thickness sensor used in the new technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Aluminum-Based Superconducting Tunnel Junction Sensors for Nuclear Recoil Spectroscopy

The BeEST experiment is searching for sub-MeV sterile neutrinos by measuring nuclear recoil energies from the decay of 7 Be implanted into superconducting tunnel junction (STJ) sensors. The recoil spectra are affected by interactions between the radioactive implants and the sensor materials. We are therefore developing aluminum-based STJs (Al-STJs) as an alternative to existing tantalum devices (Ta-STJs) to investigate how to separate material effects in the recoil spectrum from potential signatures of physics beyond the Standard Model. Three iterations of Al-STJs were fabricated. The first had electrode thicknesses similar to existing Ta-STJs. They had low responsivity and reduced resolution, but were used successfully to measure 7 Be nuclear recoil spectra. The second iteration had STJs suspended on thin SiN membranes by backside etching. These devices had low leakage current, but also low yield. The final iteration was not backside etched, and the Al-STJs had thinner electrodes and thinner tunnel barriers to increase signal amplitudes. These devices achieved 2.96 eV FWHM energy resolution at 50 eV using a pulsed 355 nm (~3.5 eV) laser. These results establish Al-STJs as viable detectors for systematic material studies in the BeEST experiment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hunting Sub-GeV Dark Matter with Diamonds and Magnetic Microcalorimeters Principle

This project is to study feasibility of a new concept for the sub-GeV dark matter (DM) detection using diamond crystals and magnetic microcalorimeters (MMCs). Diamond crystals are made of low mass carbon constituent that maximize kinetic energy of nuclear recoils from sub-GeV DM scattering due to their relatively similar masses. MMC is employed as a sensitive phonon sensor to measure athermal phonons that are produced by DM scattering in diamond crystals with 100 ns timing resolution and ~10 eV energy resolution. MMC’s fast timing resolution allows high precision phonon pulse shape analysis to separate out unwanted background or noise signals in the low energy region at E < 1 keV. Especially, the low energy excess (LEE) problems have been reported in the dark matter detection community and the proposed diamond-MMC detector might be able to provide important information to understand the origins of LEE signals in DM detectors. In this project a diamond-MMC detector has been built for proof-of-concept experiments and athermal phonon collection efficiencies have been investigated for single crystal and poly-crystal chemical-vapour-diamonds (SC and PC CVDs) as well as reference sapphire crystals are tested in the same geometries to quatify athermal phonon propagation and their collection to the MMC phonon sensors. Athermal phonon collection efficiencies and their lifetime in the diamond and sapphire crystals are successfully measured in the same geometry and experimental setup for comparison. SC CVD crystals exhibit poorer performance than the sapphire reference crystals in athermal phonon collection, while the PC CVD crystal exhibit better result than the sapphire. PC CVD with MMC phonon sensors would be feasible for sub GeV DM detection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Safeguards Technolgy Development Program FY2023 Mid-Year Report

We will develop specific aspects of ultra-high-resolution microcalorimetry that support IAEA NML needs in preparation for transfer of the technology. Two techniques will be considered: gamma spectroscopy for nondestructive isotopic analysis of milligram- to gram-scale uranium and plutonium samples, and decay energy spectroscopy (DES) for isotopic analysis of specially prepared nanogram- to microgram-scale samples of alpha decaying actinides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

LLNL measurements of thermally irradiated HEU sample and saltwater-matrixed HEU sample

Two scintillation vials, kindly provided by the PNNL team, were received in the LLNL radiochemistry building on June 10, 2024; one containing approximately 2 mL dissolved thermally-irradiated HEU, and the other containing dried salt from irradiated seawater. A quick, semiquantitative screening count of the salt showed that the activation product activities were very low, with the highest activity being ~1 Bq 24 Na. The dissolved HEU solution was transferred to a Prindle vial (LLNL standard counting geometry) and weighed. Approximately 2 mL 3 M HNO 3 was added so that the solution completely covered the bottom of the vial and Gamanal software would be able to accurately generate an efficiency curve. This sample, called “PNNLFP24” is the irradiated HEU solution received, gravimetrically diluted by a factor of 1.7356 ± 0.0003, and was sent for quick gamma counting prior to further modification. Meanwhile the salt was quantitatively transferred to a 250 mL polyethylene bottle and dissolved in 160 mL 3 M HNO 3 . After counting, 50 µL PNNLFP24 was aliquoted for Resonance Ionization Mass Spectrometry (RIMS) analysis, and then 10.0 mL of the salt solution (6.03% of the total salt, gravimetrically) was added to the remaining PNNLFP24 solution to make “PNNLFPSW24”. After weighing, two 100 µL aliquots were removed for RIMS and DES, and 3 mL was aliquoted for microfluidic chemistry. The remaining “PNNLFPSW24” solution was weighed and proceeded for singles and coincidence counting on the MCBOS system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Full-scale Demonstration of Pressurized Water Reactor Core Design Optimization using Multi-Cycle Optimization Methodology

The U.S. nuclear sector encounters a difficulty in upholding essential safety standards while also securing economic viability for continued operation. Safety stands as a pivotal factor across all facets of operations within light-water reactor nuclear power plants. Achieving economic feasibility alongside safety can be facilitated through the utilization of a risk-informed framework, exemplified by the ongoing development within the Risk-Informed Systems Analysis Pathway under the auspices of the U.S. Department of Energy's LWRS Program. This initiative advocates for a diverse array of research and development endeavors aimed at optimizing both safety and economic efficacy within nuclear power plants, particularly pertinent as many plants contemplate second license renewals. The Risk-Informed Systems Analysis Pathway has two main goals: deploy methodologies and technologies that better represent safety margins and cost and safety factors and develop advanced applications that enable cost-effective plant operation. This report assesses the potential for resolving multi-cycle plant reload challenges through real-world scenarios utilizing the Plant ReLoad Optimization (PRLO) framework. This framework offers reactor core design developers analytic tools of reactor safety and fuel performance with the assistance of artificial intelligence (AI) to enhance core design solutions. Multi-objective genetic algorithm alongside acceleration techniques is explored as an enabling technology for improving fuel efficiency while upholding safety thresholds. The demonstration of multi-cycle core design optimization is performed. This report investigates the practical application of the PRLO platform in addressing real-world core design challenges, supporting AI efforts, and contrasting outcomes with those derived from heuristic or conventional algorithms.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dark Matter Search in Pu-241 Beta Decays

Our universe is predominantly composed of mysterious unknowns: Dark Matter (DM) and Dark Energy. DM constitutes approximately 27% of the universe, yet its nature and origins remain elusive. Among the various candidates for dark matter, this project focuses on the search for keV-scale sterile neutrinos. A sterile neutrino is a hypothetical particle that belongs to the neutrino family and may possess a higher mass than ordinary neutrinos. They are considered a compelling warm dark matter candidate if their mass is on the order of kilo-electronvolts. Existence of sterile neutrinos can be investigated via high precision beta spectroscopy. Sterile neutrinos can be produced during nuclear beta decay processes, similar to ordinary active neutrinos, but they uniquely alter the beta decay spectrum. The emission of sterile neutrinos will introduce a distinctive "kink" structure in the middle of the beta spectrum. This project investigated the existence of sterile neutrino dark matter by employing high-precision decay energy spectroscopy of Pu-241 beta decays using magnetic microcalorimeters (MMCs). The Pu-241 source material is embedded within the microcalorimeter detectors, enabling the measurement of full beta decay energies with ultra-high energy resolution. In this project, the most precise Pu-241 spectrum to date was obtained by collecting a total of 1 billion beta decay events in the MMC detectors. This extensive data set allows us to investigate evidence of keV sterile neutrino emission in beta decays with unprecedented sensitivity.

79 ASTRONOMY AND ASTROPHYSICS↗

FY26 Mid-Year Report

The goal of this project is to develop specific aspects of ultra-high-resolution microcalorimeter technologies that support IAEA Nuclear Material Laboratory needs and the goals of SP-1 19/NML-003 "Microcalorimetry Analysis Technique for NML" but are outside the scope of the SP-1. The focus is on commissioning, assembly, and testing of the microcalorimeter decay energy spectrometer with superconducting transition-edge sensors (TESs) and magnetic microcalorimeters (MMCs) in preparation for transfer to the IAEA Nuclear Material Laboratory.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Harvesting Subsea Water Motion to Provide Clean Electrical Power

This TEAMER project had three main objectives related to characterizing the performance of a vortex-induced vibration (VIV) marine energy harvesting device called the Whatever Input To Torsion (WITT). The first was to characterize the motion of the WITT device as it vibrates on top of a pipe in a natural tidal flow. The second was to measure how much electricity the WITT device generates when it is deployed on top of a pipe that is secured to the seabed with a lander. The third objective was to measure how much electricity the WITT device generates in the same configuration but with a longer pipe. This TEAMER project succeeded in satisfying the first objective by measuring the motion of the WITT device with an inertial measurement unit (IMU) mounted in the WITT housing. The motion was described by examining changes in the acceleration, pitch, roll, and yaw, and displacement. The frequency of the motion was characterized using spectral analysis. The TEAMER project succeeded in reaching the second objective by measuring the power produced by the WITT. It is reported here as the average and maximum power in hourly intervals. WITT Energy decided to not have us pursue the third objective of testing a longer pipe because the first test was unexpectedly successful at having the system vibrate at the target frequency. A longer pipe would have resulted in a decreased frequency and therefore not have been a useful test. Based on these findings, the decision was made to keep the same pipe length for both tests and improve on other aspects of the test structure that had failed during the first test. The key finding of this TEAMER project is that the WITT is capable of generating electricity in moderate flow speeds when it is in a housing that is attached to a 2.5 m pipe and secured to the seabed by a lander. This report contains the first power values for a VIV instrument that generates electricity from a pendulum swinging at the top of a long pipe. The experiment demonstrated that the vibration frequency of the device varied with the tidal current speed, which changed throughout a given tidal cycle. This meant that the desired peak frequency was not sustained for more than one hour. The success of this TEAMER test provides evidence that continued research in the area of electricity generation from VIV holds promise as a source of marine energy for offshore applications. Future tests should focus on refining the pipe length equations and improving the power take off system of the WITT power electronics. In addition, experiments aimed at expanded testing and evaluation (e.g. longer than one month) are needed to measure the power production at higher tidal current speeds and test the system's durability.

Branch, Ruth A. (ORCID:0000000202356719)↗

Shake-up and shake-off spectra in the electron capture decay of atomic $^7$Be

The most stringent laboratory-based experimental limits on the existence of sub-MeV sterile neutrinos are currently set by decay spectroscopy of radioactive $^7$Be embedded into superconducting sensors. The systematic uncertainties are dominated by the modeling of the electron shake-up and shake-off spectra that are not based on state-of-the-art atomic theory and do not include electron correlations or relativistic effects. We have used the multiconfiguration Dirac-Fock formalism to obtain correlated wavefunctions ab initio and compute all single and double shake processes in the electron capture decay of atomic $^7$Be. The simulations can explain some but not all of the observed spectral features, likely because the wave functions are modified by the Ta sensor material that the $^7$Be is embedded into. The new models also show that the L/K electron capture ratio of $^7$Be in Ta has previously been slightly underestimated revising the previous value of 0.070(7) to a new value of 0.0756(20).

Atomic Physics (physics.atom-ph)↗

Report of the Topical Group on Particle Dark Matter for Snowmass 2021

This report summarizes the findings of the CF1 Topical Subgroup to Snowmass 2021, which was focused on particle dark matter. One of the most important scientific goals of the next decade is to reveal the nature of dark matter (DM). To accomplish this goal, we must delve deep, to cover high priority targets including weakly-interacting massive particles (WIMPs), and search wide, to explore as much motivated DM parameter space as possible. A diverse, continuous portfolio of experiments at large, medium, and small scales that includes both direct and indirect detection techniques maximizes the probability of discovering particle DM. Detailed calibrations and modeling of signal and background processes are required to make a convincing discovery. In the event that a candidate particle is found through different means, for example at a particle collider, the program described in this report is also essential to show that it is consistent with the actual cosmological DM. The US has a leading role in both direct and indirect detection dark matter experiments -- to maintain this leading role, it is imperative to continue funding major experiments and support a robust R&D program.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗