Engineering PapersSearch

SEARCH · Engineering Papers

Results for “GAS ANALYZER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Trace Gas Analyzer (TGA) program

The design, fabrication, and test of a breadboard trace gas analyzer (TGA) is documented. The TGA is a gas chromatograph/mass spectrometer system. The gas chromatograph subsystem employs a recirculating hydrogen carrier gas. The recirculation feature minimizes the requirement for transport and storage of large volumes of carrier gas during a mission. The silver-palladium hydrogen separator which permits the removal of the carrier gas and its reuse also decreases vacuum requirements for the mass spectrometer since the mass spectrometer vacuum system need handle only the very low sample pressure, not sample plus carrier. System performance was evaluated with a representative group of compounds.

Source record

An investigation of accelerating mode and decelerating mode constant-momentum mass spectrometry and their application to a residual gas analyzer

A theoretical analysis of constant momentum mass spectrometry was made. A maximum resolving power for the decelerating mode constant momentum mass spectrometer was shown theoretically to exist for a beam of ions of known energy. A vacuum system and an electron beam ionization source was constructed. Supporting electronics for a residual gas analyzer were built. Experimental investigations of various types of accelerating and decelerating impulsive modes of a constant momentum mass spectrometer as applied to a residual gas analyzer were made. The data indicate that the resolving power for the decelerating mode is comparable to that of the accelerating mode.

Ng, Y. S.

Hubble space telescope component qualification utilizing a residual gas analyzer

An approach is described for integrating an automated residual gas analyzer (RGA) into the thermal vacuum outgas process. The RGA has the capability of detailed analysis over a 200 amu range with monitoring of each peak as the test progresses. The NASA criterion of either a 50% reduction of each peak over 44 amu or less than an 0.1% amplitude of the 28 amu base peak for all amu's above 44 amu is satisfied. A computer sorts, reports which peaks do not satisfy the criterion, and reports test completion. The computer plots amplitudes of all the peaks from 1 amu through 200 amu for each scan. This RGA real time approach is unique in that it provides sufficient detail to highlight a problem as it occurs. By comparison, a quartz crystal microbalance (QCM) or a thermoelectric quartz crystal microbalance (TQCM) indicates to the operator when changes occur, but not what has happened. Optical witness samples indicate whether a test was satisfactory within a few days after the test was completed.

Westfall, A. H.

Evaluation of Portable Multi-Gas Analyzers for use by Safety Personnel

During confined space entry operations as well as Shuttle-safing operations, United Space Alliance (USA)/National Aeronautics and Space Administration (NASA) safety personnel use a variety of portable instrumentation to monitor for hazardous levels of compounds such as nitrogen dioxide (N%), monomethylhydrazine (NMM), FREON 21, ammonia (NH3), oxygen (O2), and combustibles (as hydrogen (H2)). Except for O2 and H2, each compound is monitored using a single analyzer. In many cases these analyzers are 5 to 10 years old and require frequent maintenance. In addition, they are cumbersome to carry and tend to make the job of personnel monitoring physically taxing. As part of an effort to upgrade the sensor technology background information was requested from a total of 27 manufacturers of portable multi-gas instruments. A set of criteria was established to determine which vendors would be selected for laboratory evaluation. These criteria were based on requests made by USA/NASA Safety personnel in order to meet requirements within their respective areas for confined-space and Shuttle-safing operations. Each of the 27 manufacturers of multi-gas analyzers was sent a copy of the criteria and asked to fill in the appropriate information pertaining to their instrumentation. Based on the results of the sensor criteria worksheets, a total of 9 vendors out of 27 surveyed manufacturers were chosen for evaluation. Each vendor included in the final evaluation process was requested to configure each of two analyzers with NO2, NH3, O2, and combustible sensors. A set of lab tests was designed in order to determine which of the multi-gas instruments under evaluation was best suited for use in both shuttle and confined space operations. These tests included linearity/repeatability, zero/span drift response/recovery, humidity, interference, and maintenance. At the conclusion of lab testing three vendors were selected for additional field testing. Based on the results of both the lab and field evaluations a single vendor was recommended for use by NASA/IJSA Safety personnel. Vendor selection criteria, as well as the results from both laboratory and field testing of the multi-gas analyzers, are presented as part of this paper.

Lueck, D. E.

Characteristics and performance of several mass spectrometer residual gas analyzers

The operation and properties of various mass-spectrometer residual gas analyzers for use in vacuum measurements were analyzed in terms of efficiencies of ion extraction, ion separation and transmission, and ion collection. Types of instruments studied were magnetic sector, omegatron, quadrupole, and monopole. Experimental results presented include absolute sensitivity to argon, relative sensitivity to 10 gases, and cracking patterns for these gases. It is shown that the properties are strongly dependent on instrument range, resolution, and the particular voltages, currents, or field intensities used to control the instrument.

Hultzman, W. W.

Design, fabrication, assembly and delivery of a laboratory prototype of a residual gas analyzer

The design, development, and testing of a wide mass range residual gas analyzer which will be one component of an integrated real time contamination monitor system are described. The instrument has been developed and tested to the laboratory prototype phase, demonstrating the performance that can be expected from a flight instrument of similar design. The instrument's analyzer is of the quadrupole type and a cold cathode ion source is employed as the ionizer. The associated electronics supply all necessary operating and mass sweep voltages for the ionizer, analyzer and electron multiplier ion detector. The instrument features a very fast linear electrometer with automatic range changing. The full mass range of 2 to 300 amu is automatically and repetitively scanned every sixty seconds and suitable telemetry outputs are provided for intensity and mass identification as well as a digital identification of the electrometer range.

Kreisman, W. S.

Program for computing partial pressures from residual gas analyzer data

A computer program for determining the partial pressures of various gases from residual-gas-analyzer data is given. The analysis of the ion currents of 18 m/e spectrometer peaks allows the determination of 12 gases simultaneously. Comparison is made to ion-gage readings along with certain other control information. The output data are presented in both tabular and graphical form.

Easton, D. S.

Gas Analyzer

The M200 originated in the 1970's under an Ames Research Center/Stanford University contract to develop a small, lightweight gas analyzer for Viking Landers. Although the unit was not used on the spacecraft, it was further developed by The National Institute for Occupational Safety and Health (NIOSH). Three researchers from the project later formed Microsensor Technology, Inc. (MTI) to commercialize the analyzer. The original version (Micromonitor 500) was introduced in 1982, and the M200 in 1988. The M200, a more advanced version, features dual gas chromatograph which separate a gaseous mixture into components and measure concentrations of each gas. It is useful for monitoring gas leaks, chemical spills, etc. Many analyses are completed in less than 30 seconds, and a wide range of mixtures can be analyzed.

Source record

In-Lab Rapid Analytical Detection of Lunar Volatiles By Universal Gas Analyzer With Comparison to GC-MS System

Introduction: The curation of permanently shadowed regions (PSRs) [1] on the lunar surface is centered around studies based upon the observed volatiles from the LCROSS mission [2]. The rapid detection of important volatile gases and vapors present in planetary bodies and Astromaterials by a standalone analytical device is an area of intense research interest in our group and Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility and this work is relevant to the future preparation of viable lunar simulants for testing curation efforts down the road. The groundbreaking results obtained from the LCROSS Mission [2] open the requirements for the direct detection of volatiles present in regolith materials collected from the lunar surface. The mass spectrometry of volatile chemicals is a general technique that utilizes a set of instruments that creates charged ions from a gaseous chemical species and measures the intensities vs. mass-to-charge ratio (m/z) [3]. In this context, we discuss in-lab experimental results and procedures for rapid qualitative analysis of main LCROSS volatiles (water, H2S, NH3, CO2, and CH3OH) by a Universal Gas Analyzer (UGA) instrument. Additionally, the instrument performance was evaluated by measuring the isotopic abundance ratio of atmospheric Ar-40 to Ar-36 present in room air since, argon is a relevant gas in planetary studies as it can provide an insight and reference point to isotope studies [4]. Additional, cross comparisons were attempted and made between the two instruments to develop a robust analytical technique by comparing mass spectral data for H2S headspace samples with a Trace-1310/ ISQ 7000 (ThermoFisher Scientific.) GC-MS system. Background: The benchtop UGA System is equipped with an SRS UGA 300 quadrupole mass spectrometer designed and built by Stanford Research Systems [5]. This system can be configured for several types of gaseous chemical analysis. The inlet line continuously samples gases at low flow rates (several milliliters per minute) through a capillary limiting the intake pressure making the instrument ideal for online analysis of select gases and/or room atmosphere. Moreover, in our current UGA system, a change in composition at the inlet can be detected in about 200 milliseconds and a complete spectrum is acquired (for a range of 1-100 amu) in under 45 sec with masses measured at rates up to 25 msec per point [5]. This system provides a quick upstream analytical data that we can then compare to results obtained by our GC-MS system. Sample Preparation: Small volume (2-4 mL) of analyte sample was taken in a 10 mL glass vial and sealed with a crimped cap and purged with pure Ar or N2 gas to displace air from the top. The headspace sample was scanned by the UGA instrument at analog, histogram, and pressure vs. time modes. The isotopic abundance ratio for 40Ar-to-36Ar was estimated by measuring partial pressure vs. time scans and setting the mass at 40 and 36 respectively. Results and Discussions: In this work, we have investigated the applicability of the UGA system by qualitative analysis of a series of LCROSS volatiles measured individually. Fig. 1 demonstrates a set of vertically offset spectra for the partial pressures measured as a function of mass-to-charge (m/z) ratios. The average acquisition time for each spectrum was less than a minute suggesting that the UGA system is ideal for quick analysis of geochemical volatiles. For the cross-comparison, we analyzed an H2S headspace sample by a Trace-1310/ISQ-7000 system and compared mass spectral data with previously measured UGA histogram scan data (Fig. 2). In both cases, major peak positions are the same, however, the intensities of fragment ions ([1H132S]+ and [32S]+) are higher for UGA suggesting that the fragment ionization process is stronger in UGA compared to that of GC-MS. To investigate how the integrated area under each chromatogram varies with the headspace sample volume, a set of five H2S headspace samples with increasing volumes was analyzed by the GC-MS system (Fig. 3, inset). A small volume (e.g., 200 to 1000 µL) of H2S/H2O vapor was withdrawn from a 20 mL stock sample vial containing ~5 mL of 0.4% H2S in water by a gas-tight syringe and added to another 20 mL vial filled with argon and analyzed by the GC-MS system. Finally, the UGA detector sensitivity was evaluated by calculating the atmospheric 40Ar-to-36Ar isotopic abundance ratio in room air by running a partial pressure vs. time scan with setting the atomic mass at 40, and 36. Fig. 4(a) shows a ~25 min duration “P vs. time” scan for 40Ar (plot for 36Ar is not shown). The partial pressure values (~100 points) were corrected by subtracting the corresponding background pressure value for 37Ar and utilized to calculate 40Ar-to-36Ar isotopic abundance ratios as shown by Fig. 4b. The average isotopic abundance ratio is ~306 with a 2*STDEV ~13. This abundance ratio is significantly close to the previously reported value of 298.56 [6] and the ratio obtained by our GC-MS system (303 for a UHP grade Ar sample). Conclusions: Our study strongly evidenced that the benchtop UGA system is a valuable analytical tool for the detection of major LCROSS volatiles. The rapid scanning capability, the inexpensiveness of the whole system, and impressive detection sensitivity prove its worthiness as an essential device for advanced geochemical applications. Moreover, cross comparisons with the GC-MS provide important bridges into advanced curatorial efforts into the future. References: [1] Bickel, V.T., et al. (2021) Nat Commun 12, 5607. [2] Colaprete, A., et al. (2010) Science, 330, 463-468. [3] Glavin, D. P. et al. (2012) 2012 IEEE Aerospace Conference, 1-11. [4] Willett, C. D., et al. (2022) Geochimica et Cosmochimica Acta 329, 119-134. [5] Operation Manual and Programming Reference. (2018) Universal gas Analyzers, Stanford Research Systems. [6] Lee, J. Y., et al. (2006) Geochimica et Cosmochimica Acta 70, 4507–4512. Notes: (4 figures are attached with text as shown by the attached file)

Curation

Development of a Contingency Gas Analyzer for the Orion Crew Exploration Vehicle

NASA's experience with electrochemical sensors in a hand-held toxic gas monitor serves as a basis for the development of a fixed on-board instrument, the Contingency Gas Analyzer (CGA), for monitoring selected toxic combustion products as well as oxygen and carbon dioxide on the Orion Crew Exploration Vehicle (CEV). Oxygen and carbon dioxide are major components of the cabin environment and accurate measurement of these compounds is critical to maintaining a safe working environment for the crew. Fire or thermal degradation events may produce harmful levels of toxic products, including carbon monoxide (CO), hydrogen cyanide (HCN), and hydrogen chloride (HCl) in the environment. These three components, besides being toxic in their own right, can serve as surrogates for a panoply of hazardous combustion products. On orbit monitoring of these surrogates provides for crew health and safety by indicating the presence of toxic combustion products in the environment before, during and after combustion or thermal degradation events. Issues identified in previous NASA experiences mandate hardening the instrument and components to endure the mechanical and operational stresses of the CEV environment while maintaining high analytical fidelity. Specific functional challenges involve protecting the sensors from various anticipated events- such as rapid pressure changes, low cabin pressures, and extreme vibration/shock exposures- and extending the sensor lifetime and calibration periods far beyond the current state of the art to avoid the need for on-orbit calibration. This paper focuses on lessons learned from the earlier NASA hardware, current testing results, and engineering solutions to the identified problems. Of particular focus will be the means for protecting the sensors, addressing well known cross-sensitivity issues and the efficacy of a novel self monitoring mechanism for extending sensor calibration periods.

Niu, Bill

Temperature, density, and composition in the disturbed thermosphere from Esro 4 gas analyzer measurements - A global model

An analysis of density measurements of Ar, N2, O, and He made at 280 km with the gas analyzer aboard the polar-orbiting satellite Esro 4 has yielded a global model of the variations in temperature, density, and composition that occur in the disturbed thermosphere. In the model the increase of temperature over quiet conditions is a nonlinear function of the planetary geomagnetic index, its latitude profile being approximated by a fourth-power sin phi law, where phi is the 'invariant' magnetic latitude. A density wave proceeding from high latitudes is approximated by a fourth power cos phi law. A strong nonlinearity in the relation between the temperature variations and the variations in the height of the homopause explains a previously found behavioral difference in the variation of atomic oxygen during magnetic storms and during periods of sustained geomagnetic activity.

Jacchia, L. G.

Summary of Results from the Mars Phoenix Lander's Thermal Evolved Gas Analyzer

The Mars Phoenix Scout Mission with its diverse instrument suite successfully examined several soils on the Northern plains of Mars. The Thermal and Evolved Gas Analyzer (TEGA) was employed to detect evolved volatiles and organic and inorganic materials by coupling a differential scanning calorimeter (DSC) with a magnetic-sector mass spectrometer (MS) that can detect masses in the 2 to 140 dalton range [1]. Five Martian soils were individually heated to 1000 C in the DSC ovens where evolved gases from mineral decompostion products were examined with the MS. TEGA s DSC has the capability to detect endothermic and exothermic reactions during heating that are characteristic of minerals present in the Martian soil.

Sutter, B.

(Ca,Mg)-Carbonate and Mg-Carbonate at the Phoenix Landing Site: Evaluation of the Phoenix Lander's Thermal Evolved Gas Analyzer (TEGA) Data Using Laboratory Simulations

Calcium carbonate (4.5 wt. %) was detected in the soil at the Phoenix Landing site by the Phoenix Lander s The Thermal and Evolved Gas Analyzer [1]. TEGA operated at 12 mbar pressure, yet the detection of calcium carbonate is based on interpretations derived from thermal analysis literature of carbonates measured under ambient (1000 mbar) and vacuum (10(exp -3) mbar) conditions [2,3] as well as at 100 and 30 mbar [4,5] and one analysis at 12 mbar by the TEGA engineering qualification model (TEGA-EQM). Thermodynamics (Te = H/ S) dictate that pressure affects entropy ( S) which causes the temperature (Te) of mineral decomposition at one pressure to differ from Te obtained at another pressure. Thermal decomposition analyses of Fe-, Mg-, and Ca-bearing carbonates at 12 mbar is required to enhance the understanding of the TEGA results at TEGA operating pressures. The objectives of this work are to (1) evaluate the thermal and evolved gas behavior of a suite of Fe-, Mg-, Ca-carbonate minerals at 1000 and 12 mbar and (2) discuss possible emplacement mechanisms for the Phoenix carbonate.

Sutter, B.

Organic Combustion in the Presence of Ca-Carbonate and Mg-Perchlorate: A Possible Source for the Low Temperature CO2 Release Seen in Mars Phoenix Thermal and Evolved Gas Analyzer Data

Two of the most important discoveries of the Phoenix Lander were the detection of approx.0.6% perchlorate [1] and 3-5% carbonate [2] in landing site soils. The Thermal and Evolved Gas Analyzer (TEGA) instrument on the Phoenix lander could heat samples up to approx.1000 C and monitor evolved gases with a mass spectrometer. TEGA detected a low (approx.350 C) and high (approx.750 C) temperature CO2 release. The high temp release was attributed to the thermal decomposition of Ca-carbonate (calcite). The low temperature CO2 release could be due to desorption of CO2, decomposition of a different carbonate mineral, or the combustion of organic material. A new hypothesis has also been proposed that the low temperature CO2 release could be due to the early breakdown of calcite in the presence of the decomposition products of certain perchlorate salts [3]. We have investigated whether or not this new hypothesis is also compatible with organic combustion. Magnesium perchlorate is stable as Mg(ClO4)2-6H2O on the martian surface [4]. During thermal decomposition, this perchlorate salt releases H2O, Cl2, and O2 gases. The Cl2 can react with water to form HCl which then reacts with calcite, releasing CO2 below the standard thermal decomposition temperature of calcite. However, when using concentrations of perchlorate and calcite similar to what was detected by Phoenix, the ratio of high:low temperature CO2 evolved is much larger in the lab, indicating that although this process might contribute to the low temp CO2 release, it cannot account for all of it. While H2O and Cl2 cause calcite decomposition, the O2 evolved during perchlorate decomposition can lead to the combustion of any reduced carbon present in the sample [5]. We investigate the possible contribution of organic molecules to the low temperature CO2 release seen on Mars.

Archer, Douglas

Regolith Evolved Gas Analyzer (REGA): An Instrument to Characterize the Martian Soil Mineralogy and Atmosphere Composition

This abstract describes an instrument and experiment to be proposed for a future Mars surface mission to conduct basic research on environmental characterization. The Regolith Evolved Gas Analyzer (REGA) experiment is designed to provide information on Mars surface material properties in preparation for human missions of exploration. The goals of the investigation are: 1) Define and determine surface mineralogy of soil and dust and their effects on humans and machines; and 2) Conduct in-situ investigations aimed at identifying possible evidence of past or present life on Mars.

Hoffman, John H.

The Search for Water and Other Volatiles in Martian Surface Materials: The Thermal Evolved Gas Analyzer (TEGA)

Volatile-bearing minerals and phases (e.g., Fe-oxyhydroxides, phyllosilicates, carbonates, sulfates, palagonites, glasses) may be important components of the Martian regolith. However, essentially no information exists on the mineralogical composition of volatile-bearing phases in the regolith. The Thermal Evolved Gas Analyzer (TEGA), which was part of the Mars Polar Lander payload, was to determine the abundances of two of the most important volatile compounds (i.e., water and carbon dioxide) in the martian soil and to identify the minerals or phases that harbor these volatiles. The TEGA instrument was composed of a differential scanning calorimeter (DSC) interfaced with evolved gas analysis (EGA). The EGA consisted of a Herriott cell of a tunable-diode laser (TDL) spectrometer that determines CO2 and H2O abundances. The sample chamber was to operate at about 100 mbar (-76 torr) with a N2 carrier gas flow of 0.4 sccm. Specifications of TEGA are described in detail elsewhere in this volume.

Ming, D. W.

A Possible Organic Contribution to the Low Temperature CO2 Release Seen in Mars Phoenix Thermal and Evolved Gas Analyzer Data

Two of the most important discoveries of the Phoenix Mars Lander were the discovery of approx.0.6% perchlorate [1] and 3-5% carbonate [2] in the soils at the landing site in the martian northern plains. The Thermal and Evolved Gas Analyzer (TEGA) instrument was one of the tools that made this discovery. After soil samples were delivered to TEGA and transferred into small ovens, the samples could be heated up to approx.1000 C and the gases that evolved during heating were monitored by a mass spectrometer. A CO2 signal was detected at high temperature (approx.750 C) that has been attributed to calcium carbonate decomposition. In addition to this CO2 release, a lower temperature signal was seen. This lower temperature CO2 release was postulated to be one of three things: 1) desorption of CO2, 2) decomposition of a different carbonate mineral, or 3) CO2 released due to organic combustion. Cannon et al. [3] present another novel hypothesis involving the interaction of decomposition products of a perchlorate salt and calcium carbonate.

Archer, P. D. Jr.