Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Nucleon spin structure and perturbative QCD frontier on the move

We discuss the interplay between higher orders of the perturbative QCD expansion and higher-twist contributions in the analysis of recent Jefferson Lab data on the lowest moments of spin-dependent proton and neutron structure functions {Gamma}{sub 1}{sup p,n}(Q{sup 2}) and Bjorken sum rule function {Gamma}{sub 1}{sup p-n}(Q{sup 2}) at 0.05<Q{sup 2}<3 GeV{sup 2}. We demonstrate that the values of the higher-twist coefficients {mu}{sub 2k}{sup p,n} extracted from the mentioned data by using the singularity-free analytic perturbation theory provide a better convergence of the higher-twist series than with the standard perturbative QCD. From the high-precision proton data, we extract the value of the singlet axial charge a{sub 0}(1 GeV{sup 2})=0.33{+-}0.05. We observe a slow Q{sup 2} dependence of fitted values of the twist coefficient {mu}{sub 4} and a{sub 0} when going to lower energy scales, which can be explained by the well-known renormalization group evolution of {mu}{sub 4}(Q{sup 2}) and a{sub 0}(Q{sup 2}). As the main result, a good quantitative description of all the Jefferson Lab data sets down to Q{approx_equal}350 MeV is achieved.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-492: Influence of Clipping PTV in Build-Up Region On IMRT Plan Quality and Deliverability

Purpose: To study the influence of clipping PTV from body contour on plan quality and deliverability in build-up region for superficial target. Methods: Five previously treated patients of post-operative carcinoma of parotid were re-planned for IMRT (6MV X-rays, sliding window technique, five fields and 60Gy/30 fractions) using eclipse treatment planning system (TPS) by keeping dose volume constraints and all other parameters constant, only PTV was clipped from body contour by 0mm, 1mm, 2mm and 3mm respectively. Planned fluence was transferred to previously scanned solid water phantom by placing I’matriXX array at 0.5cm depth (2mm slab+3mm inherent). Fluence was delivered by Varian CL2300C/D linac at 99.5cm source to detector distance. Measured fluence was compared with TPS dose plane using 2D gamma evaluation using 3%/3mm DTA criteria. Total MU (monitor unit) required to deliver a plan was also noted. For plan quality, PTV, maximum-dose, minimum-dose, coverage index (CI=PTV volume covered by prescription dose/PTV) and heterogeneity index HI=D5/D95 were analyzed using dose volume histogram (DVH). Results: The Result of gamma function analysis for I’matriXX and TPS were 97.63±1.79%, 97.48±0.99, 98.08±0.89% and 98.01±0.78% at 0.5cm build-up depth for 0, 1, 2 and 3mm PTV clipping, respectively. I’matriXX measured dose was higher compared to TPS. Total MU required for delivering a plan were 552±61, 503±47, 436±24 and 407±22. Maximum-dose to PTV was 6635.80±62.01cGy, 6635.80±40.60cGy, 6608.43±51.07cGy and 6564.20±28.51cGy. Similarly, minimum-dose to PTV was 3306.23±458.56cGy, 3546.57±721.01cGy, 4591.43±298.81cGy and 4861.90±412.40cGy. CI was 0.9347±0.020, 0.9398±0.021, 0.9448±0.022 and 0.9481±0.021. Similarly, HI was 1.089±0.015, 1.084±0.014, 1.078±0.009 and 1.074±0.008 for 0, 1, 2 and 3mm PTV clipping, respectively. Conclusion: Gamma function analysis resulted in almost similar results. However, I’matriXX was overestimating the dose compared to TPS. MU required to deliver a plan decreases with increase in PTV clipping. CI, PTV minimum-dose and plan homogeneity increases with increase in PTV clipping from skin.

60 APPLIED LIFE SCIENCES↗

Improvement of Stratospheric Aerosol Extinction Retrieval from OMPS/LP Using a New Aerosol Model

The Ozone Mapping and Profiler Suite Limb Profiler (OMPS/LP) has been flying on the Suomi National Polar-orbiting Partnership (S-NPP) satellite since October 2011. It is designed to produce ozone and aerosol vertical profiles at 2-kilometer vertical resolution over the entire sunlit globe. Aerosol extinction profiles are computed with Mie theory using radiances measured at 675 nanometers. The operational Version 1.0 (V1.0) aerosol extinction retrieval algorithm assumes a bimodal lognormal aerosol size distribution (ASD) whose parameters were derived by combining an in situ measurement of aerosol microphysics with the Stratospheric Aerosol and Gas Experiment (SAGE II) aerosol extinction climatology. Internal analysis indicates that this bimodal lognormal ASD does not sufficiently explain the spectral dependence of LP-measured radiances. In this paper we describe the derivation of an improved aerosol size distribution, designated Version 1.5 (V1.5), for the LP retrieval algorithm. The new ASD uses a gamma function distribution that is derived from Community Aerosol and Radiation Model for Atmospheres (CARMA)-calculated results. A cumulative distribution fit derived from the gamma function ASD gives better agreement with CARMA results at small particle radii than bimodal or unimodal functions. The new ASD also explains the spectral dependence of LP-measured radiances better than the V1.0 ASD. We find that the impact of our choice of ASD on the retrieved extinctions varies strongly with the underlying reflectivity of the scene. Initial comparisons with collocated extinction profiles retrieved at 676 nanometers from the SAGE III instrument on the International Space Station (ISS) show a significant improvement in agreement for the LP V1.5 retrievals. Zonal mean extinction profiles agree to within 10 percent between 19 and 29 kilometers, and regression fits of collocated samples show improved correlation and reduced scatter compared to the V1.0 product. This improved agreement will motivate development of more sophisticated ASDs from CARMA results that incorporate latitude, altitude and seasonal variations in aerosol properties.

Ozone Mapping Profiler Suite Limb Profiler (OMPS/L↗

On Study of Air/Space-borne Dual-Wavelength Radar for Estimates of Rain Profiles

In this study, a framework is discussed to apply air/space-borne dual-wavelength radar for the estimation of characteristic parameters of hydrometeors. The focus of our study is on the Global Precipitation Measurements (GPM) precipitation radar, a dual-wavelength radar that operates at Ku (13.8 GHz) and Ka (35 GHz) bands. As the droplet size distributions (DSD) of rain are expressed as the Gamma function, a procedure is described to derive the median volume diameter (D(sub 0)) and particle number concentration (N(sub T)) of rain. The correspondences of an important quantity of dual-wavelength radar, defined as deferential frequency ratio (DFR), to the D(sub 0) in the melting region are given as a function of the distance from the 0 C isotherm. A self-consistent iterative algorithm that shows a promising to account for rain attenuation of radar and infer the DSD without use of surface reference technique (SRT) is examined by applying it to the apparent radar reflectivity profiles simulated from the DSD model and then comparing the estimates with the model (true) results. For light to moderate rain the self-consistent rain profiling approach converges to unique and correct solutions only if the same shape factors of Gamma functions are used both to generate and retrieve the rain profiles, but does not converges to the true solutions if the DSD form is not chosen correctly. To further examine the dual-wavelength techniques, the self-consistent algorithm, along with forward and backward rain profiling algorithms, is then applied to the measurements taken from the 2nd generation Precipitation Radar (PR-2) built by Jet Propulsion Laboratory. It is found that rain profiles estimated from the forward and backward approaches are not sensitive to shape factor of DSD Gamma distribution, but the self-consistent method is.

Liao, Liang↗

Comparison of γZ-structure function models

The γZ-box is an important contribution to the proton's weak charge. The γZ-box is calculated dispersively and depends on γZ-structure functions, F{sub 1,2,3}{sup γZ}(x,Q{sup 2}). At present there is no data for these structure functions and they must be modeled by modifying existing fits to electromagnetic data. Each group that has studied the γZ-box used different modifications. The results of the PVDIS experiment at Jefferson Lab may provide a first test of the validity of each group's models. I present details of the different models and their predictions for the PVDIS result.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Statistical (n,$$\gamma $$) cross section model comparison for short-lived nuclei

Abstract Neutron-capture cross sections of neutron-rich nuclei are calculated using a Hauser–Feshbach model when direct experimental cross sections cannot be obtained. A number of codes to perform these calculations exist, and each makes different assumptions about the underlying nuclear physics. We investigated the systematic uncertainty associated with the choice of Hauser-Feshbach code used to calculate the neutron-capture cross section of a short-lived nucleus. The neutron-capture cross section for $$^{73}\hbox {Zn}$$ 73 Zn (n, $$\gamma $$ γ ) $$^{74}\hbox {Zn}$$ 74 Zn was calculated using three Hauser-Feshbach statistical model codes: TALYS, CoH, and EMPIRE. The calculation was first performed without any changes to the default settings in each code. Then an experimentally obtained nuclear level density (NLD) and $$\gamma $$ γ -ray strength function ( $$\gamma \hbox {SF}$$ γ SF ) were included. Finally, the nuclear structure information was made consistent across the codes. The neutron-capture cross sections obtained from the three codes are in good agreement after including the experimentally obtained NLD and $$\gamma \hbox {SF}$$ γ SF , accounting for differences in the underlying nuclear reaction models, and enforcing consistent approximations for unknown nuclear data. It is possible to use consistent inputs and nuclear physics to reduce the differences in the calculated neutron-capture cross section from different Hauser-Feshbach codes. However, ensuring the treatment of the input of experimental data and other nuclear physics are similar across multiple codes requires a careful investigation. For this reason, more complete documentation of the inputs and physics chosen is important.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gamma-ray strength functions and their relation to astrophysics

The nuclear {gamma}-ray strength function is one of the indispensable inputs needed for reaction-rate calculations, and is particularly important for the neutron-capture cross section. The nuclear physics group at the Oslo Cyclotron Laboratory has developed a method to extract simultaneously nuclear level density and {gamma}-ray strength function from particle-{gamma} coincidence measurements. Data on the strength functions of Sn nuclei as well as for lighter elements are presented. The Sn isotopes all display a resonance-like structure close to the neutron threshold, that could possibly be due to the neutron-skin oscillation mode. This so-called pygmy dipole resonance greatly influences the neutron-capture rates. In the lighter nuclei, an enhancement of the strength function at low {gamma} energies is observed. The possible impact of this increase on Maxwellian-averaged reaction rates has been investigated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Closed-Form E1 Radiative Strength Functions for Gamma-Decay and Photoabsorption

Photoabsorption cross sections and {gamma}-decay strength functions are calculated and compared with experimental data to test simple phenomenological models of E1 gamma-strength description in the middle-weight and heavy atomic nuclei. Radiative strength functions with energy asymmetric shape are recommended for overall estimation of averaged gamma-strengths. Systematics for giant dipole resonance (GDR) parameters are given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The {gamma}-ray Strength Function in Nuclear Astrophysics

The {gamma}-ray strength function is a key statistical nuclear ingredient to the s-, r- and p-process nucleosynthesis of heavy elements. It has recently become apparent that extra {gamma}-ray strengths that appear near neutron threshold on top of the low-energy tail of GDR play an important role in neutron capture and photodisintegration. We discuss extra {gamma}-ray strengths of pigmy E1 and giant M1 nature based on the latest experimental photoneutron cross sections measured with laser Compton scattering {gamma}-rays.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-T-568: QA of a Multi-Target Multi-Dose VMAT SRS

Purpose: To, experimentally, corroborated the prescribed doses utilizing dosimeters (e.g. films and TLDs) that can provide high spatial resolution, allow dose measurement of multiple targets at once, and provide accurate dosimetric results. Methods: A single-isocenter 6FFF SRS VMAT plan consisting of one 358° arc at 0° couch angle and four 179° arcs at 30°, 60°, 330° and 300° couch angles respectively, was generated in ECLIPSE v.11 using a Rando-Alderson anthropomorphic head phantom CT study. This plan was a reproduction of a clinical plan generated for a stage-IV melanoma patient diagnosed with 19 intracranial lesions. The phantom was loaded with axially mounted (between phantom slabs) Gafchromic EBT3 film and TLDs strategically positioned within various target volumes. Film and TLDS were calibrated according to established protocols. Target prescription doses were 16 Gy (3cc≤, 3 lesions), 18 Gy (∼1–3cc, 10 lesions) and 20 Gy (≤1cc, 6 lesions). Phantom setup was verified through CBCT imaging prior to irradiation. Gafchromic films were scanned in transmission mode and TLDs were read, respectively, ∼24 hrs after irradiation. Results: Dose calibrated Gafchromic film data were compared to the ECLIPSE calculated data using a 3% / 3mm gamma function analysis. Results for the gamma values were 96–99% in agreement with the calculated data and with 84–90% of the film pixels within the 3% dose difference. TLD data showed a dose difference of 0.4–8% while the film data for those same locations yielded a difference of 0.4–4%. It was observed that the highest dose discrepancies correlated with the location of the small volume targets. Conclusion: Overall this study corroborated that a VMAT SRS treatment, employing various treatment table rotations and arcs, to multiple intracranial lesions with multiple dose prescriptions can be delivered accurately with the existing radiotherapy technology.

60 APPLIED LIFE SCIENCES↗

Ab initio calculation of double ionization of atoms

The Solov'ev-Vinitsky method was used to perform an ab initio calculation of the triple-differential cross section for the double single-photon photoionization of helium for the case of equal emitted-electron energies. A Gaussian width {gamma} describing angular electron-electron correlations at the total electron energy E taking values in range between 0.1 and 100 eV was obtained for this cross section. The results agree with available experimental data, but they raise a doubt as to whether the well-known Wannier law {gamma} {proportional_to} E{sup 1/4} is applicable at experimentally accessible energies. The Gaussian width {gamma} was investigated as a function of the total emitted-electron energy for targets that have a strongly asymmetric configuration of the initial state-specifically, a negative atomic-hydrogen ion H{sup -} and heliumin the 1s2s{sup 1}S and 1s3s{sup 1}S excited states. It was found that this function, {gamma}(E), had a maximum at low energies. It was also shown that, at low energies, the dependence of the double-differential cross section on the angle between the emitted-electron momenta for the targets indicated above differed substantially from the Gaussian dependence, featuring maxima whose number was equal to the number of radial nodes in the initial state. This opens new possibilities for a qualitative analysis of the electron structure of targets.

74 ATOMIC AND MOLECULAR PHYSICS↗

Further Development of a Function Generator Technique

Further features and properties of functions generated by generalization of the process originally uncovered to describe the evolution of pressure in a rigid volume due to outgassing or desorption are explored. Properties presented include development of a general Maclaurin series associated with these functions, a limitation in using integration by parts to produce asymptotic expansions, and a general description of an implicit Adams-Moulton method for numerical quadrature of transformed functions. These developments are then applied to develop and explore functions that solve the Sievert integral and the modified Bessel function of the first kind, order zero. Features of the error function and the incomplete lower gamma function are also considered.

Michael S. Woronowicz↗

Coupling External Radiation Transport Code Results to the GADRAS Detector Response Function

Simulating gamma spectra is useful for analyzing special nuclear materials. Gamma spectra are influenced not only by the source and the detector, but also by the external, and potentially complex, scattering environment. The scattering environment can make accurate representations of gamma spectra difficult to obtain. By coupling the Monte Carlo Nuclear Particle (MCNP) code with the Gamma Detector Response and Analysis Software (GADRAS) detector response function, gamma spectrum simulations can be computed with a high degree of fidelity even in the presence of a complex scattering environment. Traditionally, GADRAS represents the external scattering environment with empirically derived scattering parameters. By modeling the external scattering environment in MCNP and using the results as input for the GADRAS detector response function, gamma spectra can be obtained with a high degree of fidelity. This method was verified with experimental data obtained in an environment with a significant amount of scattering material. The experiment used both gamma-emitting sources and moderated and bare neutron-emitting sources. The sources were modeled using GADRAS and MCNP in the presence of the external scattering environment, producing accurate representations of the experimental data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE CHEMICAL SIGNATURES OF THE FIRST STAR CLUSTERS IN THE UNIVERSE

The chemical abundance patterns of the oldest stars in the Galaxy are expected to contain residual signatures of the first stars in the early universe. Numerous studies attempt to explain the intrinsic abundance scatter observed in some metal-poor populations in terms of chemical inhomogeneities dispersed throughout the early Galactic medium due to discrete enrichment events. Just how the complex data and models are to be interpreted with respect to 'progenitor yields' remains an open question. Here we show that stochastic chemical evolution models to date have overlooked a crucial fact. Essentially, all stars today are born in highly homogeneous star clusters and it is likely that this was also true at early times. When this ingredient is included, the overall scatter in the abundance plane [Fe/H] versus [X/Fe] (C-space), where X is a nucleosynthetic element, can be much less than derived from earlier models. Moreover, for moderately flat cluster mass functions ({gamma} {approx}< 2), and/or for mass functions with a high mass cutoff (M{sub max} {approx}> 10{sup 5} M{sub sun}), stars exhibit a high degree of clumping in C-space that can be identified even in relatively small data samples. Since stellar abundances can be modified by mass transfer in close binaries, clustered signatures are essential for deriving the yields of the first supernovae. We present a statistical test to determine whether a given set of observations exhibit such behavior. Our initial work focuses on two dimensions in C-space, but we show that the clustering signal can be greatly enhanced by additional abundance axes. The proposed experiment will be challenging on existing 8-10 m telescopes, but relatively straightforward for a multi-object echelle spectrograph mounted on a 25-40 m telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

New determination of the millisecond pulsar gamma-ray luminosity function and implications for the Galactic Center gamma-ray excess

It has been suggested that the Galactic Center gamma-ray excess (GCE) could be produced by a large number of centrally located millisecond pulsars. The fact that no such pulsar population has been detected implies that these sources must be very faint and very numerous. Here, in this study, we use the contents of Fermi’s recently released Third Pulsar Catalog (3PC) to measure the luminosity function of the millisecond pulsars in the Milky Way’s disk. We find that this source population exhibits a luminosity function with a mean γ -ray luminosity of ⟨ L γ ⟩ ∼ 6 × 10 32 erg / s (integrated above 0.1 GeV). If the GCE were generated by millisecond pulsars with the same luminosity function, we find that ∼ 20 such sources from the inner Galaxy population should have already been detected by Fermi and included in the 3PC. Given the lack of such observed sources, we exclude the hypothesis that the GCE is generated by pulsars with the same luminosity function as those in the Galactic disk with a significance of 3.4 σ . We conclude that either less than 39% of the GCE is generated by pulsars, or that the millisecond pulsars in the inner Galaxy are at least 5 times less luminous on average than those found in the Galactic disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Linearization of dose-response curve of the radiochromic film dosimetry system

Purpose: Despite numerous advantages of radiochromic film dosimeter (high spatial resolution, near tissue equivalence, low energy dependence) to measure a relative dose distribution with film, one needs to first measure an absolute dose (following previously established reference dosimetry protocol) and then convert measured absolute dose values into relative doses. In this work, we present result of our efforts to obtain a functional form that would linearize the inherently nonlinear dose-response curve of the radiochromic film dosimetry system. Methods: Functional form [{zeta}= (-1){center_dot}netOD{sup (2/3)}/ln(netOD)] was derived from calibration curves of various previously established radiochromic film dosimetry systems. In order to test the invariance of the proposed functional form with respect to the film model used we tested it with three different GAFCHROMIC Trade-Mark-Sign film models (EBT, EBT2, and EBT3) irradiated to various doses and scanned on a same scanner. For one of the film models (EBT2), we tested the invariance of the functional form to the scanner model used by scanning irradiated film pieces with three different flatbed scanner models (Epson V700, 1680, and 10000XL). To test our hypothesis that the proposed functional argument linearizes the response of the radiochromic film dosimetry system, verification tests have been performed in clinical applications: percent depth dose measurements, IMRT quality assurance (QA), and brachytherapy QA. Results: Obtained R{sup 2} values indicate that the choice of the functional form of the new argument appropriately linearizes the dose response of the radiochromic film dosimetry system we used. The linear behavior was insensitive to both film model and flatbed scanner model used. Measured PDD values using the green channel response of the GAFCHROMIC Trade-Mark-Sign EBT3 film model are well within {+-}2% window of the local relative dose value when compared to the tabulated Cobalt-60 data. It was also found that criteria of 3%/3 mm for an IMRT QA plan and 3%/2 mm for a brachytherapy QA plan are passing 95% gamma function points. Conclusions: In this paper, we demonstrate the use of functional argument to linearize the inherently nonlinear response of a radiochromic film based reference dosimetry system. In this way, relative dosimetry can be conveniently performed using radiochromic film dosimetry system without the need of establishing calibration curve.

60 APPLIED LIFE SCIENCES↗

Initiation of persistent fission chains in the fast burst reactor Caliban

We provide in this article, experimental data of initiation of persistent fission chains obtained at different supercritical states, using the Fast Burst Reactor CALIBAN. In many past papers, theory has been compared mostly to initiation experiments at various super-prompt critical states, whereas very few experimental data has been published in delayed supercritical states. To fill the lack of data, we have conducted three campaigns on the reactor at reactivities far below 0.7$ which was one of the rare lowest state ever published on a similar assembly [2][1]. We give a justification of the use of the gamma function to fit experimental results of the temporal distributions of waiting times and compare experiments with numerical simulations obtained with a zero-D punctual Monte Carlo code. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗