Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Free Field Characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Calibration of High Frequency MEMS Microphones

Understanding and controlling aircraft noise is one of the major research topics of the NASA Fundamental Aeronautics Program. One of the measurement technologies used to acquire noise data is the microphone directional array (DA). Traditional direction array hardware, consisting of commercially available condenser microphones and preamplifiers can be too expensive and their installation in hard-walled wind tunnel test sections too complicated. An emerging micro-machining technology coupled with the latest cutting edge technologies for smaller and faster systems have opened the way for development of MEMS microphones. The MEMS microphone devices are available in the market but suffer from certain important shortcomings. Based on early experiments with array prototypes, it has been found that both the bandwidth and the sound pressure level dynamic range of the microphones should be increased significantly to improve the performance and flexibility of the overall array. Thus, in collaboration with an outside MEMS design vendor, NASA Langley modified commercially available MEMS microphone as shown in Figure 1 to meet the new requirements. Coupled with the design of the enhanced MEMS microphones was the development of a new calibration method for simultaneously obtaining the sensitivity and phase response of the devices over their entire broadband frequency range. Over the years, several methods have been used for microphone calibration. Some of the common methods of microphone calibration are Coupler (Reciprocity, Substitution, and Simultaneous), Pistonphone, Electrostatic actuator, and Free-field calibration (Reciprocity, Substitution, and Simultaneous). Traditionally, electrostatic actuators (EA) have been used to characterize air-condenser microphones for wideband frequency ranges; however, MEMS microphones are not adaptable to the EA method due to their construction and very small diaphragm size. Hence a substitution-based, free-field method was developed to calibrate these microphones at frequencies up to 80 kHz. The technique relied on the use of a random, ultrasonic broadband centrifugal sound source located in a small anechoic chamber. Phase calibrations of the MEMS microphones were derived from cross spectral phase comparisons between the reference and test substitution microphones and an adjacent and invariant grazing-incidence 1/8-inch standard microphone.

Shams, Qamar A.↗

Deep-ultraviolet ptychographic pocket-scope (DART): mesoscale lensless molecular imaging with label-free spectroscopic contrast

The mesoscale characterization of biological specimens has traditionally required compromises between resolution, field-of-view, depth-of-field, and molecular specificity, with most approaches relying on external labels. Here we present the Deep-ultrAviolet ptychogRaphic pockeT-scope (DART), a handheld platform that transforms label-free molecular imaging through intrinsic deep-ultraviolet spectroscopic contrast. By leveraging biomolecules’ natural absorption fingerprints and combining them with lensless ptychographic microscopy, DART resolves down to 308-nm linewidths across centimeter-scale areas while maintaining millimeter-scale depth-of-field. The system’s virtual error-bin methodology effectively eliminates artifacts from limited temporal coherence and other optical imperfections, enabling high-fidelity molecular imaging without lenses. Through differential spectroscopic imaging at deep-ultraviolet wavelengths, DART quantitatively maps nucleic acid and protein distributions with femtogram sensitivity, providing an intrinsic basis for explainable virtual staining. We demonstrate DART’s capabilities through imaging of tissue sections, cytopathology specimens, blood cells, and neural populations, revealing detailed molecular contrast without external labels. The combination of high-resolution molecular mapping and broad mesoscale imaging in a portable platform opens new possibilities from rapid clinical diagnostics, tissue analysis, to biological characterization in space exploration.

60 APPLIED LIFE SCIENCES↗

Coronal holes.

Coronal holes are extensive regions of extremely low density in the solar corona within 60 deg of latitude from the equator. We have superposed maps of the calculated current-free (potential) coronal magnetic field with maps of the coronal electron density for the period of November 1966, and find that coronal holes are generally characterized by weak and diverging magnetic field lines. The chromosphere underlying the holes is extremely quiet, being free of weak plages and filaments. The existence of coronal holes clearly has important implications for the energy balance in the transition region and the solar wind.

Altschuler, M. D.↗

Simultaneous bright- and dark-field X-ray microscopy at X-ray free electron lasers

Abstract The structures, strain fields, and defect distributions in solid materials underlie the mechanical and physical properties across numerous applications. Many modern microstructural microscopy tools characterize crystal grains, domains and defects required to map lattice distortions or deformation, but are limited to studies of the (near) surface. Generally speaking, such tools cannot probe the structural dynamics in a way that is representative of bulk behavior. Synchrotron X-ray diffraction based imaging has long mapped the deeply embedded structural elements, and with enhanced resolution, dark field X-ray microscopy (DFXM) can now map those features with the requisite nm-resolution. However, these techniques still suffer from the required integration times due to limitations from the source and optics. This work extends DFXM to X-ray free electron lasers, showing how the $$10^{12}$$ 10 12 photons per pulse available at these sources offer structural characterization down to 100 fs resolution (orders of magnitude faster than current synchrotron images). We introduce the XFEL DFXM setup with simultaneous bright field microscopy to probe density changes within the same volume. This work presents a comprehensive guide to the multi-modal ultrafast high-resolution X-ray microscope that we constructed and tested at two XFELs, and shows initial data demonstrating two timing strategies to study associated reversible or irreversible lattice dynamics.

47 OTHER INSTRUMENTATION↗

Mean free paths of energetic particles at very large heliodistances (Pioneer 11 at 20 AU)

The parallel mean free path and the diffusion coefficient parallel to the magnetic field line are derived from magnetic field data at 20 AU to characterize heliospheric modulation and energetic-particle/magnetic-field interaction. The computational method of Moussas et al. (1975, 1982) is employed, and the values of the parallel mean free path are shown to be significantly larger than the values estimated in studies of up to 6 AU. The distance dependence of the parallel diffusion mean free path is found to follow a power law, and the diffusion coefficient dependence upon energy is determined by a constant mean free path and the velocity of the particle. The contribution of the diffusion coefficient perpendicular to the magnetic field is expected to dominate the radial diffusion coefficient of cosmic rays, although the contribution of the diffusion parallel to the field is important with respect to the small-scale structure of intensity gradients.

Moussas, X.↗

Low-frequency rotational noise in closed-test-section wind tunnels

The effects of closed-section wind-tunnel walls on the sound field radiated from a helicopter rotor are investigated by means of numerical simulations, summarizing the findings reported by Mosher (1986). The techniques used to model the rotor and the test section (including geometry, wall absorption, and measurement location) are outlined, and the results are presented in extensive tables and graphs. It is found that first-harmonic acoustic measurements obtained in a hard-walled wind tunnel twice as wide as the rotor diameter do not accurately represent the free-field rotational noise, that the relationship between the sound-pressure levels in the wind tunnel and in the free field is complex, that multiple near-field measurements are needed to characterize the direct acoustic field of the rotor, and that absorptive linings are of little value in enlarging the accurate-measurement zone.

Mosher, Marianne↗

Electric Motor Noise for Small Quadcopters: Part I - Acoustic Measurements

There is increased interest in using electric motors to drive propulsors across a range of small air vehicle classes. Applications include both vertical lift and conventional takeoff and landing systems for Small Unmanned Aircraft Systems. Mission profiles call for integrating these systems into urban airspaces exposing populated areas to new noise sources. In addition to the propulsor noise from rotors and propellers, electric motors are expected to contribute to the overall sound levels and possibly human annoyance. This work presents acoustic measurements of electric motors used for small quadcopters to characterize the sound and identify sources with and without a propeller. Free field microphone measurements were used to determine directivity and a phased microphone array was used to identify sound sources. A companion paper (Part II – Source Characteristics and Prediction) compares the far field results with current probe measurements of the signal driving the motor, the structural response of the motor case, and describes prediction methods of electric motor noise.

Aircraft Noise↗

Electric Motor Noise from Small Quadcopters: Part 1 - Acoustic Measurements

There is increased interest in using electric motors to drive propulsors across a range of small air vehicle classes. Applications include both vertical lift and conventional takeoff and landing systems for Small Unmanned Aircraft Systems. Mission profiles call for integrating these systems into urban airspaces exposing populated areas to new noise sources. In addition to the propulsor noise from rotors and propellers, electric motors are expected to contribute to the overall sound levels and possibly human annoyance. This work presents acoustic measurements of electric motors used for small quadcopters to characterize the sound and identify sources with and without a propeller. Free field microphone measurements were used to determine directivity and a phased microphone array was used to identify sound sources. A companion paper (Part II - Source Characteristics and Prediction) compares the far field results with current probe measurements of the signal driving the motor, the structural response of the motor case, and describes prediction methods of electric motor noise.

Electric Propulsion↗

Preflare magnetic and velocity fields

A characterization is given of the preflare magnetic field, using theoretical models of force free fields together with observed field structure to determine the general morphology. Direct observational evidence for sheared magnetic fields is presented. The role of this magnetic shear in the flare process is considered within the context of a MHD model that describes the buildup of magnetic energy, and the concept of a critical value of shear is explored. The related subject of electric currents in the preflare state is discussed next, with emphasis on new insights provided by direct calculations of the vertical electric current density from vector magnetograph data and on the role of these currents in producing preflare brightenings. Results from investigations concerning velocity fields in flaring active regions, describing observations and analyses of preflare ejecta, sheared velocities, and vortical motions near flaring sites are given. This is followed by a critical review of prevalent concepts concerning the association of flux emergence with flares

Hagyard, M. J.↗

Electric Potential and Electric Field Imaging with Applications

The technology and techniques for remote quantitative imaging of electrostatic potentials and electrostatic fields in and around objects and in free space is presented. Electric field imaging (EFI) technology may be applied to characterize intrinsic or existing electric potentials and electric fields, or an externally generated electrostatic field may be used for (illuminating) volumes to be inspected with EFI. The baseline sensor technology, electric field sensor (e-sensor), and its construction, optional electric field generation (quasistatic generator), and current e-sensor enhancements (ephemeral e-sensor) are discussed. Demonstrations for structural, electronic, human, and memory applications are shown. This new EFI capability is demonstrated to reveal characterization of electric charge distribution, creating a new field of study that embraces areas of interest including electrostatic discharge mitigation, crime scene forensics, design and materials selection for advanced sensors, dielectric morphology of structures, inspection of containers, inspection for hidden objects, tether integrity, organic molecular memory, and medical diagnostic and treatment efficacy applications such as cardiac polarization wave propagation and electromyography imaging.

Generazio, Ed↗

Electric Potential and Electric Field Imaging with Dynamic Applications: 2017 Research Award Innovation

The technology and methods for remote quantitative imaging of electrostatic potentials and electrostatic fields in and around objects and in free space is presented. Electric field imaging (EFI) technology may be applied to characterize intrinsic or existing electric potentials and electric fields, or an externally generated electrostatic field may be used for illuminating volumes to be inspected with EFI. The baseline sensor technology (e-Sensor) and its construction, optional electric field generation (quasi-static generator), and current e- Sensor enhancements (ephemeral e-Sensor) are discussed. Critical design elements of current linear and real-time two-dimensional (2D) measurement systems are highlighted, and the development of a three dimensional (3D) EFI system is presented. Demonstrations for structural, electronic, human, and memory applications are shown. Recent work demonstrates that phonons may be used to create and annihilate electric dipoles within structures. Phonon induced dipoles are ephemeral and their polarization, strength, and location may be quantitatively characterized by EFI providing a new subsurface Phonon-EFI imaging technology. Initial results from real-time imaging of combustion and ion flow, and their measurement complications, will be discussed. These new EFI capabilities are demonstrated to characterize electric charge distribution creating a new field of study embracing areas of interest including electrostatic discharge (ESD) mitigation, crime scene forensics, design and materials selection for advanced sensors, combustion science, on-orbit space potential, container inspection, remote characterization of electronic circuits and level of activation, dielectric morphology of structures, tether integrity, organic molecular memory, atmospheric science, and medical diagnostic and treatment efficacy applications such as cardiac polarization wave propagation and electromyography imaging.

Generazio, Ed↗

Electric Potential and Electric Field Imaging with Dynamic Applications & Extensions

The technology and methods for remote quantitative imaging of electrostatic potentials and electrostatic fields in and around objects and in free space is presented. Electric field imaging (EFI) technology may be applied to characterize intrinsic or existing electric potentials and electric fields, or an externally generated electrostatic field made be used for volumes to be inspected with EFI. The baseline sensor technology (e-Sensor) and its construction, optional electric field generation (quasi-static generator), and current e- Sensor enhancements (ephemeral e-Sensor) are discussed. Critical design elements of current linear and real-time two-dimensional (2D) measurement systems are highlighted, and the development of a three dimensional (3D) EFI system is presented. Demonstrations for structural, electronic, human, and memory applications are shown. Recent work demonstrates that phonons may be used to create and annihilate electric dipoles within structures. Phonon induced dipoles are ephemeral and their polarization, strength, and location may be quantitatively characterized by EFI providing a new subsurface Phonon-EFI imaging technology. Results from real-time imaging of combustion and ion flow, and their measurement complications, will be discussed. Extensions to environment, Space and subterranean applications will be presented, and initial results for quantitative characterizing material properties are shown. A wearable EFI system has been developed by using fundamental EFI concepts. These new EFI capabilities are demonstrated to characterize electric charge distribution creating a new field of study embracing areas of interest including electrostatic discharge (ESD) mitigation, manufacturing quality control, crime scene forensics, design and materials selection for advanced sensors, combustion science, on-orbit space potential, container inspection, remote characterization of electronic circuits and level of activation, dielectric morphology of structures, tether integrity, organic molecular memory, atmospheric science, weather prediction, earth quake prediction, and medical diagnostic and treatment efficacy applications such as cardiac polarization wave propagation and electromyography imaging.

Generazio, Ed↗

Statistically-driven Experimental Design to Improve Reference-free Quantification of Small Molecules by Liquid Chromatography-Mass Spectrometry

Non-targeted analysis of small molecules and metabolites in unknown, complex samples using liquid chromatography-tandem mass spectrometry remains challenging. One of the main bottlenecks is the extensive unannotated regions of metabolomics mass spectrometry data, resulting in knowledge gaps. Small molecule annotation in mass spectrometry data has conventionally relied on reference standards and libraries for compound identification and confirmation, which can constrain compound identification to those molecules already known, thus limiting the ability to discover new knowledge and new markers. Retention time prediction can facilitate and expedite unknown compound identification in non-targeted analysis of complex metabolomics samples. Additionally, accurate retention time predictions can also inform sample mixture design for LC-MS/MS analyses. However, current machine learning-based methods for retention time prediction are typically developed for specific chromatographic platforms and are not generalizable across scales. And while technologies and methods to improve reference-free metabolite identification for more comprehensive annotation of unknowns has received much attention, development of the same for quantitation without reference standards has been much more limited, despite its importance in toxicological, environmental, food safety, forensics, and clinical applications. We believe that a reference-free quantitation strategy that exploits mass spectrometry data already collected for reference-free identification can provide much more insight on unknowns, and move the metabolomics field for more complete unknowns characterization. As such, we pursue two efforts to improve upon current state-of-the-art methods in non-targeted analysis: (1) machine learning-based retention time prediction and (2) statistical design of experiments framework for reference-free quantitation. In this work, we develop and demonstrate (1) a generalizable retention time prediction capability across chromatographic conditions and scales, and (2) a statistical design-based framework for response factor contribution elucidation and reference-free quantitation. Evaluation of our retention time prediction model, PrediToR, showed approximately 24% improvement over current models, and we observed approximately 10X improvement in concentration estimation accuracy from our statistical design-based response factor model over a primarily ionization efficiency-based model. We expect that future efforts to improve upon these new capabilities will further advance non-targeted analysis of small molecules towards truly reference-free metabolomics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resolving Graphite‐Electrolyte Interphase of Lithium‐Ion Batteries using Air‐Tight Ambient Mass Spectrometry

Abstract The formation of a stable solid electrolyte interphase (SEI) at graphite electrode is necessary for lithium‐ion batteries (LIB) to prevent excessive degradation of electrolytes. Until now, the exact organic composition of SEI has not been decisively determined with lithium ethylene mono‐carbonate (LEMC) being one of the debated components. An air‐tight ambient mass spectrometry (MS) platform is developed to directly characterize the air‐sensitive organic components present in SEI. Ionization occurs via a solvent‐free field‐induced process at atmospheric pressure. Our experimental data, based on tandem MS analysis, revealed LEMC to be the major organic component in SEI. This result resolves a long‐standing mystery surrounding the composition of native SEI in LIB, where no trace of the other debated compound, lithium ethylene dicarbonate, was detected. The energetics of fragmentation of LEMC and the corresponding stabilities of various ionic species detected during the air‐tight ambient MS analysis were calculated using density functional theory (DFT). Our findings confirmed favorable protonation energies and suggested the molecular structures for many of the detected species. Solvent (i. e., ethylene carbonate)‐induced stabilization effects observed during the ionization process were also confirmed by DFT. The reported study encourages the routine use of ambient mass spectrometry to characterize both anodic and cathodic electrodes of all battery types as well as to study other air‐sensitive materials in their native state.

25 ENERGY STORAGE↗

Field Calibration Techniques used to Characterize the Radiometric Stability of the GEO-CAPE Airborne Simulator (GCAS)

The GEOstationary Coastal and Air Pollution Events (GEO-CAPE) Airborne Simulator (GCAS) was developed at NASA’s Goddard Space Flight Center (GSFC) and has flown in multiple field campaigns to perform mapping of the regional-scale EPA criteria pollutants nitrogen dioxide, ozone, and formaldehyde. GCAS will also participate invalidation campaigns for NASA’s Tropospheric Emissions: Monitoring POllution (TEMPO) mission and the Korean Geostationary Environment Monitoring Spectrometer (GEMS) mission, both scheduled to launch in the early 2020s. GCAS houses two commercial Offner-type grating spectrometers that measure backscattered solar spectral radiance from the near-ultraviolet to near-infrared at high spatial resolution (typically 250 meters at 8.5 kilometer altitude). These radiances are used to retrieve spatial and temporal distributions of trace gases relevant to the boundary layer and free tropospheric atmospheric chemistry cycles. In this paper, we describe the field calibration techniques employed to characterize the spectral and temporal radiometric stability of the system during its most recent deployment in the 2018 Long Island Sound Trace Ozone Study (LISTOS) field campaign. Overall measurement uncertainty, retrieval impacts, and lessons learned for future deployments will also be described.

NASA’s Tropospheric Emissions: Monitoring POllutio↗

Physics-informed Estimation of the Covariance Matrix for Various Neutron Spectra

A method for estimating covariance matrices which capture the uncertainties in calculated reactor spectra has been developed. This method is based on perturbing the parameters of a physics-based analytic model fitted to a calculated spectrum. The covariance of the perturbed analytic spectra imposes energy-dependent correlations due to the physics of the neutron processes in the reactor, i.e., a fission component, a 1/E down-scatting component, and a thermal Maxwellian component. An analytic model is developed which is shown to produce good fits to several reactor environments. The covariance matrices produced via this method are then used as the prior spectrum in STAYSL least squares spectrum adjustment where it is combined with integral metrics, such as activation measurements, to produce a high-fidelity neutron spectrum characterization. It was concluded that the methodology showed agreeable results for the ACRR free-field spectrum adjustment in STAYSL resulting in a 𝜒 2 value of 2.21 (per degree of freedom), but further work is needed to describe scattering and interface regions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Equilibrium of magnetic fields with arbitrary interweaving of the lines of force. II - Discontinuities in the field

The surfaces of discontinuity (SDs) identified by Parker (1986) in the torsion of a force-free magnetic field in an infinitely conducting fluid contained betweeen two fixed boundary planes are characterized analytically. It is shown that field discontinuities (current sheets) occur whenever an SD terminates within the fluid or intersects with another SD, that intersections occur in most cases, and that the resulting current sheets are responsible for most field dissipation in highly conducting fluids. The astrophysical implications of these findings and a number of unresolved problems are discussed.

Parker, E. N.↗

Infrared imaging - A validation technique for computational fluid dynamics codes used in STOVL applications

The need for a validation technique for computational fluid dynamics (CFD) codes in STOVL applications has led to research efforts to apply infrared thermal imaging techniques to visualize gaseous flow fields. Specifically, a heated, free-jet test facility was constructed. The gaseous flow field of the jet exhaust was characterized using an infrared imaging technique in the 2 to 5.6 micron wavelength band as well as conventional pitot tube and thermocouple methods. These infrared images are compared to computer-generated images using the equations of radiative exchange based on the temperature distribution in the jet exhaust measured with the thermocouple traverses. Temperature and velocity measurement techniques, infrared imaging, and the computer model of the infrared imaging technique are presented and discussed. From the study, it is concluded that infrared imaging techniques coupled with the radiative exchange equations applied to CFD models are a valid method to qualitatively verify CFD codes used in STOVL applications.

Hardman, R. R.↗