Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Force Measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

NASA ATP Force Measurement Technology Capability Strategic Plan

The Aeronautics Test Program (ATP) within the National Aeronautics and Space Administration (NASA) Aeronautics Research Mission Directorate (ARMD) initiated a strategic planning effort to re-vitalize the force measurement capability within NASA. The team responsible for developing the plan included members from three NASA Centers (Langley, Ames and Glenn) as well as members from the Air Force s Arnold Engineering and Development Center (AEDC). After visiting and discussing force measurement needs and current capabilities at each participating facility as well as selected force measurement companies, a strategic plan was developed to guide future NASA investments. This paper will provide the details of the strategic plan and include asset management, organization and technology research and development investment priorities as well as efforts to date.

Rhew, Ray D.↗

The preliminary checkout, evaluation and calibration of a 3-component force measurement system for calibrating propulsion simulators for wind tunnel models

The propulsion simulator calibration laboratory (PSCL) in which calibrations can be performed to determine the gross thrust and airflow of propulsion simulators installed in wind tunnel models is described. The preliminary checkout, evaluation and calibration of the PSCL's 3 component force measurement system is reported. Methods and equipment were developed for the alignment and calibration of the force measurement system. The initial alignment of the system demonstrated the need for more efficient means of aligning system's components. The use of precision alignment jigs increases both the speed and accuracy with which the system is aligned. The calibration of the force measurement system shows that the methods and equipment for this procedure can be successful.

Scott, W. A.↗

Force Measurements of Single and Double Barrier DBD Plasma Actuators in Quiescent Air

We have performed measurements of the force induced by both single (one electrode insulated) and double (both electrodes insulated) dielectric barrier discharge plasma actuators in quiescent air. We have shown that, for single barrier actuators, as the electrode diameter decreased below those values previously studied the induced Force increases exponentially rather than linearly. This behavior has been experimentally verified using two different measurement techniques: stagnation probe measurements of the induced flow velocity and direct measurement of the force using an electronic balance. In addition, we have shown the the induced force is independent of the material used for the exposed electrode. The same techniques have shown that the induced force of a double barrier actuator increases with decreasing narrow electrode diameter.

Hoskinson, Alan R.↗

Comparisons of Force Measurement Methods for DBD Plasma Actuators in Quiescent Air

We have performed measurements of the force induced by both single (one electrode insulated) and double (both electrodes insulated) dielectric barrier discharge plasma actuators in quiescent air. We have shown that, for single barrier actuators with cylindrical exposed electrodes, as the electrode diameter decrease the force efficiencies increase much faster than a previously reported linear trend. This behavior has been experimentally verified using two different measurement techniques: stagnation probe measurements of the induced flow velocity and direct measurement of the force using an electronic balance. Actuators with rectangular cross-section exposed electrodes do not show the same rapid increase at small thicknesses. We have also shown that the induced force is independent of the material used for the exposed electrode. The same techniques have shown that the induced force of a double barrier actuator increases with decreasing narrow electrode diameter.

Hoskinson, Alan R.↗

Direct force-measuring transducer used in blood pressure research

Direct force measuring transducer acts as an arterial tonometer, gives a direct readout to instrumentation, and is unaffected by ambient noise. It uses a semiconductor strain gage which is deflected by pressure pulses in the artery. The deflection changes the resistance of the gage and alters the voltage reading on the associated instrumentation.

Eige, J. J.↗

Update: Partnership for the Revitalization of National Wind Tunnel Force Measurement Technology Capability

NASA's Aeronautics Test Program (ATP) chartered a team to examine the issues and risks associated with the lack of funding and focus on force measurement over the past several years, focusing specifically on strain-gage balances. NASA partnered with the U.S. Air Force's Arnold Engineering Development Center (AEDC) to exploit their combined capabilities and take a national level government view of the problem and established the National Force Measurement Technology Capability (NFMTC) project. This paper provides an update on the team's status for revitalizing the government's balance capability with respect to designing, fabricating, calibrating, and using the these critical measurement devices.

Rhew, Ray D.↗

Icing Research Tunnel (IRT) Force Measurement System (FMS)

An Electronics Engineer at the Glenn Research Center (GRC), requested the NASA Engineering and Safety Center (NESC) provide technical support for an evaluation of the existing force measurement system (FMS) at the GRC's Icing Research Tunnel (IRT) with the intent of developing conceptual designs to improve the tunnel's force measurement capability in order to better meet test customer needs. This report contains the outcome of the NESC technical review.

Roberts, Paul W.↗

Subminiature transducers for measuring forces and deformation of heart muscle

Two subminiature transducers, one measuring muscle forces and one measuring muscle displacement, can be inserted into heart muscle without interfering with it. Probe, approximately 1 mm (0.04 in), causes no damage to heart muscle. Probe can be rotated to different positions to measure muscle forces from various directions.

Feldstein, C.↗

Aerodynamic force measurements with a strain-gage balance in a cryogenic wind tunnel

Aerodynamic force measurements on a generalized 75 deg delta wing model with sharp leading edges were made with a three component internal strain gage balance in a cryogenic wind tunnel at stagnation temperatures of 300 K, 200 K, and 110 K. The feasibility of using a strain gage balance without thermal control in a cryogenic environment as well as the use of electrical resistance heaters, an insulator between the model and the balance, and a convection shield on the balance was investigated. Force and moment data on the delta wing model as measured by the balance are compared at the different temperatures while holding constant either the Reynolds number or the tunnel stagnation pressure. Tests were made at Mach numbers of 0.3 and 0.5 and at angles of attack up to 29 deg. The results indicate that it is feasible to acquire accurate force and moment data while operating at steady state thermal conditions in a cryogenic wind tunnel, either with or without electrical heaters on the balance. Within the limits of the balance accuracy, there were no apparent Reynolds number effects on the aerodynamic results for the delta wind model.

Boyden, R. P.↗

Force Measurements in Magnetic Suspension and Balance System

The description of an infrared telemetry system for measurement of drag forces in Magnetic Suspension and Balance Systems (MSBS) is presented. This system includes a drag force sensor, electronic pack and transmitter placed in the model which is of special construction, and receiver with a microprocessor-based measuring device, placed outside of the test section. Piezosensitive resonators as sensitive elements and non-magnetic steel as the material for the force sensor are used. The main features of the proposed system for load measurements are discussed and the main characteristics are presented.

Kuzin, Alexander↗

Two-Pulsed Technique for Ablative Laser Propulsion: Force Measurement in Vacuum

This is a continuation of studies using a two-pulsed technique for Ablative Laser Propulsion (ALP) extended to force measurements in vacuum. Aluminum samples were ablated using pairs of laser pulses, each of 100 ps width, 532 nm wavelength and 5 mJ energy. The pulses were temporally separated in the 0 - 0.67 ns range. The force imparted on Al targets was measured in situ by means of a piezoelectric force gauge. The preliminary results confirm the previously reported oscillatory behavior of ion velocity and number density observed by means of a time-of-flight energy analyzer. The uncertainties of presented measurements and future directions for the study are discussed.

Herren, Kenneth A.↗

Force Measurement for Wind Tunnel Facilities - Current Practices and Research Investments

This presentation will provide an introduction to strain gage balances (force transducers) used in NASA’s wind tunnel facilities. It will cover the breadth of wind tunnel applications using balances ranging from cryogenic facilities to facilities with aero heating affects. Specific areas of expertise including six-component balance design and calibration will also be discussed. Moreover, research areas including additive manufacturing of wind tunnel balances, the development of topology optimization tools to produce novel force transducer geometries, and dynamic force measurement will also be highlighted.

Wind tunnel balance↗

Development of Field Excavator with Embedded Force Measurement

A semi-intelligent excavation mechanism was developed for use with the NASA-built Centaur 2 rover prototype. The excavator features a continuously rotatable large bucket supported between two parallel arms, both of which share a single pivot axis near the excavator base attached to the rover. The excavator is designed to simulate the collection of regolith, such as on the Moon, and to dump the collected soil into a hopper up to one meter tall for processing to extract oxygen. Because the vehicle can be autonomous and the terrain is generally unknown, there is risk of damaging equipment or using excessive power when attempting to extract soil from dense or rocky terrain. To minimize these risks, it is critical for the rover to sense the digging forces and adjust accordingly. It is also important to understand the digging capabilities and limitations of the excavator. This paper discusses the implementation of multiple strain gages as an embedded force measurement system in the excavator's arms. These strain gages can accurately measure and resolve multi-axial forces on the excavator. In order to validate these sensors and characterize the load capabilities, a series of controlled excavation tests were performed at Glenn Research Center with the excavator at various depths and cut angles while supported by a six axis load cell. The results of these tests are both compared to a force estimation model and used for calibration of the embedded strain gages. In addition, excavation forces generated using two different types of bucket edge (straight vs. with teeth) were compared.

Soils↗

Aerodynamic Characteristics of NACA RM-10 Missile in 8- by 6-foot Supersonic Wind Tunnel at Mach Numbers from 1.49 to 1.98 II : Presentation and Analysis of Force Measurements

Experimental investigation of aerodynamic forces acting on body of revolution (NACA RM-10 missile) with and without stabilizing fins was conducted at Mach numbers from 1.49 to 1.98 at angles of attack from 0 to 9 degrees and at Reynolds number of approximately 30,000,000. Comparison of experimental lift, drag, and pitching-moment coefficients and center of pressure location for body alone is made with linearized potential theory and a semiempirical method. Results indicate that aerodynamic characteristics were predicted more accurately by semiempirical method than by potential theory. Breakdown of measured drag coefficients into components of friction, pressure, and base-pressure drag is presented for body alone at zero angle of attack.

TAIL-BODY COMBINATIONS - MISSILES↗

Acoustic force measurement in a dual-temperature resonant chamber

The acoustic radiation force was measured for a dual-temperature resonant chamber. This rectangular chamber has its long dimension approximately 8.5 times the square cross-sectional dimension, and the opposite ends are at widely different temperatures. Force profiles were obtained for two hot end temperatures of 520 C and 760 C, while the cool end remained at approximately room temperature. Force magnitudes as high as 17 dyn for a sample 1.2 cm in diameter at 760 C and at 162-dB input level were measured.

Robey, Judith L.↗