Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Focal planes.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Future directions in focal-plane signal processing for space-borne scientific imagers

The potential of focal-plane signal processing for space-borne scientific imagers is discussed. Significant improvement in image quality and consequent scientific return may be enabled through the utilization of focal-plane signal processing techniques. The possible application of focal-plane signal processing to readout noise reduction, cosmic ray circumvention, non-uniformity correction, and throughput enhancement is described. On-focal-plane analog-to-digital (A/D) conversion and micromotion stabilization are also discussed. It is the intention of this paper to stimulate further thought and efforts in this field.

Fossum, Eric R.↗

Focal Plane Geometry Characterization of the Kepler Mission

The Kepler Mission focal plane contains 42 charge-coupled device (CCD) photodetectors. Each CCD is composed of 2.2 million square pixels, 27 micrometers on a side, arranged in a grid of 2,200 columns by 1,044 rows. The science goals of the Kepler Mission require that the position of each CCD be determined with an accuracy of 0.1 pixels, corresponding to 2.7 micrometers or 0.4 seconds of arc, a level which is not achievable through pre-flight metrology. We describe a technique for determining the CCD positioning using images of the Kepler field of view (FOV) obtained in flight. The technique uses the fitted centroid row and column positions of 400 pre-selected stars on each CCD to obtain empirical polynomials which relate sky coordinates (right ascension and declination) to chip coordinates (row and column). The polynomials are in turn evaluated to produce constraints for a nonlinear model fit which directly determines the model parameters describing the location and orientation of each CCD. The focal plane geometry characterization algorithm is itself embedded in an iterative process which determines the focal plane geometry and the Pixel Response Function for each CCD in a self-consistent manner. In addition to the fully automated calculation, a person-in-the-loop implementation was developed to allow an initial determination of the geometry in the event of large misalignments, achieving a much looser capture tolerance for more modest accuracy and reduced automation.

ccd↗

Interferometric focal planes

We propose arrays of integrated interferometers to characterize the mutual intensity on focal planes. While focal coherence measurement does not increase the aperture-limited spatial bandpass, it can increase Shannon information capacity relative to irradiance measurement by increasing the number of degrees of freedom per Nyquist sample. We describe a sampling model for interferometric measurement using arrays of 2-port Mach-Zehnder interferometers and show within this model that interferometric focal planes enable more accurate estimation of prototypical scene parameters.

Brady, David J. (ORCID:0000000156552478)↗

MWIR and LWIR Megapixel QWIP Focal Plane Arrays

A mid-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) 1024x1024 pixel quantum well infrared photodetector (QWIP) focal plane array has been demonstrated with excellent imagery. MWIR focal plane has given noise equivalent differential temperature (NETD) of 19 mK at 95K operating temperature with f/2.5 optics at 300K background and LWIR focal plane has given NEDT of 13 mK at 70K operating temperature with same optical and background conditions as MWIR array. Both of these focal plane arrays have shown background limited performance (BLIP) at 90K and 70K operating temperatures with the same optics and background conditions. In this paper, we will discuss their performance in quantum efficiency, NETD, uniformity, and operability.

multi band↗

An Integrated Optimal Estimation Approach to Spitzer Space Telescope Focal Plane Survey

This paper discusses an accurate and efficient method for focal plane survey that was used for the Spitzer Space Telescope. The approach is based on using a high-order 37-state Instrument Pointing Frame (IPF) Kalman filter that combines both engineering parameters and science parameters into a single filter formulation. In this approach, engineering parameters such as pointing alignments, thermomechanical drift and gyro drifts are estimated along with science parameters such as plate scales and optical distortions. This integrated approach has many advantages compared to estimating the engineering and science parameters separately. The resulting focal plane survey approach is applicable to a diverse range of science instruments such as imaging cameras, spectroscopy slits, and scanning-type arrays alike. The paper will summarize results from applying the IPF Kalman Filter to calibrating the Spitzer Space Telescope focal plane, containing the MIPS, IRAC, and the IRS science Instrument arrays.

optimal estimations↗

Measuring the Flatness of Focal Plane for Very Large Mosaic CCD Camera

Large mosaic multiCCD camera is the key instrument for modern digital sky survey. DECam is an extremely red sensitive 520 Megapixel camera designed for the incoming Dark Energy Survey (DES). It is consist of sixty two 4k x 2k and twelve 2k x 2k 250-micron thick fully-depleted CCDs, with a focal plane of 44 cm in diameter and a field of view of 2.2 square degree. It will be attached to the Blanco 4-meter telescope at CTIO. The DES will cover 5000 square-degrees of the southern galactic cap in 5 color bands (g, r, i, z, Y) in 5 years starting from 2011. To achieve the science goal of constraining the Dark Energy evolution, stringent requirements are laid down for the design of DECam. Among them, the flatness of the focal plane needs to be controlled within a 60-micron envelope in order to achieve the specified PSF variation limit. It is very challenging to measure the flatness of the focal plane to such precision when it is placed in a high vacuum dewar at 173 K. We developed two image based techniques to measure the flatness of the focal plane. By imaging a regular grid of dots on the focal plane, the CCD offset along the optical axis is converted to the variation the grid spacings at different positions on the focal plane. After extracting the patterns and comparing the change in spacings, we can measure the flatness to high precision. In method 1, the regular dots are kept in high sub micron precision and cover the whole focal plane. In method 2, no high precision for the grid is required. Instead, we use a precise XY stage moves the pattern across the whole focal plane and comparing the variations of the spacing when it is imaged by different CCDs. Simulation and real measurements show that the two methods work very well for our purpose, and are in good agreement with the direct optical measurements.

43 PARTICLE ACCELERATORS↗

Approaches and Analysis for On-Focal-Plane Analog-to-Digital Conversion

This paper presents approaches for on-focal-plane analog-to-digital conversion (ADC). Common approaches and architectures for ADC and their utility for on-focal-plane integration are discussed. Candidate approaches are analyzed with respect to required amplifier gain, bandwidth, capacitance matching, noise and offsets as a function of ADC resolution. A column-parallel ADC architecture appears to be an effective compromise of chip area, power, circuit speed and ADC resolution. The discussion is valid for both infrared focal-plane arrays (FPAs) and visible image sensors.

analog-to-digital↗

Performance of an Achromatic Focal Plane Mask for Exoplanet Imaging Coronagraphy

Coronagraph technology combined with wavefront control is close to achieving the contrast and inner working angle requirements in the lab necessary to observe the faint signal of an Earth-like exoplanet in monochromatic light. An important remaining technological challenge is to achieve high contrast in broadband light. Coronagraph bandwidth is largely limited by chromaticity of the focal plane mask, which is responsible for blocking the stellar PSF. The size of a stellar PSF scales linearly with wavelength; ideally, the size of the focal plane mask would also scale with wavelength. A conventional hard-edge focal plane mask has a fixed size, normally sized for the longest wavelength in the observational band to avoid starlight leakage. The conventional mask is oversized for shorter wavelengths and blocks useful discovery space. Recently we presented a solution to the size chromaticity challenge with a focal plane mask designed to scale its effective size with wavelength. In this paper, we analyze performance of the achromatic size-scaling focal plane mask within a Phase Induced Amplitude Apodization (PIAA) coronagraph. We present results from wavefront control around the achromatic focal plane mask, and demonstrate the size-scaling effect of the mask with wavelength. The edge of the dark zone, and therefore the inner working angle of the coronagraph, scale with wavelength. The achromatic mask enables operation in a wider band of wavelengths compared with a conventional hard-edge occulter.

Focal Plane Mask↗

HgCdTe infrared focal plane arrays for imaging spectrometer applications

It is pointed out that the development of two-dimensional infrared focal plane arrays (FPAs) offers new alternatives in imaging and remote sensing. Attention is given to an imaging spectrometer which represents a new concept exploiting two-dimensional arrays. This instrument is to be used for the remote sensing of the earth on the basis of a utilization of reflected sunlight in both the visible (VIS) and short wavelength infrared (SWIR). The imaging spectrometer concept is to make it possible to obtain contiguous spectral coverage at high resolution without having to use increasingly complex scanners. The concept utilizes a prism spectrometer to disperse the image of the slit across the area arrays in the focal plane. The focal plane consists of silicon CCDs for the VIS and near infrared portions of the spectrum and HgCdTe hybrid arrays for the SWIR.

Rode, J. P.↗

Multispectral linear array (MLA) focal plane mechanical and thermal design

The mechanical and thermal design of an integrated focal plane subsystem of a Multispectral Linear Array (MLA) instrument is discussed in terms of focal-plane alignment, thermoelastic performance, and thermal requirements. The modular construction and thermal control of the focal plane array are discussed.

Mitchell, A. S.↗

An Efficient Focal Plane Alignment Methodology with Application to the ASTERIA Nanosatellite Space Telescope

The process of aligning an instrument focal plane toprecursor optics such as a telescope can be a difficult and timeconsuming process. The final alignment must achieve sufficientperformance at multiple locations across the field of view. Inthe case of instruments with infinite conjugates, such as a spacetelescope, there are practical challenges in illuminating the system at multiple off-axis field points simultaneously. Iterationduring the alignment process can cause a lengthy search for localminima within the performance cost function.This paper presents a focal plane alignment methodology thatavoids the above difficulties and obtains the desired level ofoptical performance in an efficient manner. The approach isbased on systematically measuring spot size across a set of fieldpoints and defocus positions, and then using a least squaresfit to determine the optimal location for the focal plane. Thisapproach has the additional benefit of revealing the amount offield curvature present in the instrument. It also provides theanalyst with a direct calculation of the shims needed to place thefocal plane at the computed best-fit location.This approach was successfully applied to the Arcsecond SpaceTelescope Enabling Research In Astrophysics (ASTERIA) payload. ASTERIA is a cubesat mission that was deployed intolow-Earth orbit in November 2017 and operated until December2019. In addition to presenting the theoretical basis for themethodology, this paper will present laboratory measurementsobtained during the payload alignment campaign. This approach is applicable to future space-borne optical instrumentsthat require an efficient methodology for focal plane alignmentwith limited cost or schedule resources.

Smith, Matthew W↗

Long-Wavelength Infrared (LWIR) Quantum Dot Infrared Photodetector (QDIP) Focal Plane Array

We have exploited the artificial atomlike properties of epitaxially self-assembled quantum dots for the development of high operating temperature long wavelength infrared (LWIR) focal plane arrays. Quantum dots are nanometer-scale islands that form spontaneously on a semiconductor substrate due to lattice mismatch. QDIPs are expected to outperform quantum well infrared detectors (QWIPs) and are expected to offer significant advantages over II-VI material based focal plane arrays. QDIPs are fabricated using robust wide bandgap III-V materials which are well suited to the production of highly uniform LWIR arrays. We have used molecular beam epitaxy (MBE) technology to grow multi-layer LWIR quantum dot structures based on the InAs/InGaAs/GaAs material system. JPL is building on its significant QWIP experience and is basically building a Dot-in-the-Well (DWELL) device design by embedding InAs quantum dots in a QWIP structure. This hybrid quantum dot/quantum well device offers additional control in wavelength tuning via control of dot-size and/or quantum well sizes. In addition the quantum wells can trap electrons and aide in ground state refilling. Recent measurements have shown a 10 times higher photoconductive gain than the typical QWIP device, which indirectly confirms the lower relaxation rate of excited electrons (photon bottleneck) in QDPs. Subsequent material and device improvements have demonstrated an absorption quantum efficiency (QE) of approx. 3%. Dot-in-the-well (DWELL) QDIPs were also experimentally shown to absorb both 45 deg. and normally incident light. Thus we have employed a reflection grating structure to further enhance the quantum efficiency. JPL has demonstrated wavelength control by progressively growing material and fabricating devices structures that have continuously increased in LWIR response. The most recent devices exhibit peak responsivity out to 8.1 microns. Peak detectivity of the 8.1 micrometer devices has reached approx. 1 x 10(exp 10) Jones at 77 K. Furthermore, we have fabricated the first long-wavelength 640x512 pixels QDP focal plane array. This QDIP focal plane may has produced excellent infrared imagery with noise equivalent temperature difference of 40 mK at 60K operating temperature. In addition, we have managed to increase the quantum efficiency of these devices from 0.1% (according to the data published in literature) to 20% in discrete devices. This is a factor of 200 increase in quantum efficiency. With these excellent results, for the first time QDIP performance has surpassed the QWIP performance. Our goal is to operate these long-wavelength detectors at much higher operating temperature than 77K which can be passively achieved in space. This will be a huge leap in high performance infrared detectors specifically applicable to space science instruments.

infrared imaging↗

Towards Dualband Megapixel QWIP Focal Plane Arrays

Mid-wavelength infrared (MWIR) and long-wavelength infrared (LWIR) 1024 x 1024 pixel quantum well infrared photodetector (QWIP) focal planes have been demonstrated with excellent imaging performance. The MWIR QWIP detector array has demonstrated a noise equivalent differential temperature (NEDT) of 17 mK at a 95 K operating temperature with f/2.5 optics at 300 K background and the LWIR detector array has demonstrated a NEDT of 13 mK at a 70 K operating temperature with the same optical and background conditions as the MWIR detector array after the subtraction of system noise. Both MWIR and LWIR focal planes have shown background limited performance (BLIP) at 90 K and 70 K operating temperatures respectively, with similar optical and background conditions. In addition, we have demonstrated MWIR and LWIR pixel co-registered simultaneously readable dualband QWIP focal plane arrays. In this paper, we will discuss the performance in terms of quantum efficiency, NEDT, uniformity, operability, and modulation transfer functions of the 1024 x 1024 pixel arrays and the progress of dualband QWIP focal plane array development work.

Infrared detectors↗

HIGH PERFORMANCE PIAA CORONAGRAPHY WITH COMPLEX AMPLITUDE FOCAL PLANE MASKS

We describe a coronagraph approach where the performance of a Phase-Induced Amplitude Apodization (PIAA) coronagraph is improved by using a partially transmissive phase-shifting focal plane mask and a Lyot stop. This approach combines the low inner working angle offered by phase mask coronagraphy, the full throughput and uncompromized angular resolution of the PIAA approach, and the design flexibility of Apodized Pupil Lyot Coronagraph. A PIAA complex mask coronagraph (PIAACMC) is fully described by the focal plane mask size, or, equivalently, its complex transmission which ranges from 0 (opaque) to -1 (phase shifting). For all values of the transmission, the PIAACMC theoretically offers full on-axis extinction and 100% throughput at large angular separations. With a pure phase focal plane mask (complex transmission = -1), the PIAACMC offers 50% throughput at 0.64 {lambda}/D while providing total extinction of an on-axis point source. This performance is very close to the 'fundamental performance limit' of coronagraphy derived from first principles. For very high contrast level, imaging performance with PIAACMC is in practice limited by the angular size of the on-axis target (usually a star). We show that this fundamental limitation must be taken into account when choosing the optimal value of the focal plane mask size in the PIAACMC design. We show that the PIAACMC enables visible imaging of Jupiter-like planets at {approx}1.2 {lambda}/D from the host star, and can therefore offer almost three times more targets than a PIAA coronagraph optimized for this type of observation. We find that for visible imaging of Earth-like planets, the PIAACMC gain over a PIAA is probably much smaller, as coronagraphic performance is then strongly constrained by stellar angular size. For observations at 'low' contrast (below {approx} 10{sup 8}), the PIAACMC offers significant performance enhancement over PIAA. This is especially relevant for ground-based high contrast imaging systems in the near-IR, where PIAACMC enables high contrast high efficiency imaging within 1 {lambda}/D. Manufacturing tolerances for the focal plane mask are quantified for a few representative PIAACMC designs.

79 ASTRONOMY AND ASTROPHYSICS↗

Multispectral linear array focal plane

A description is provided of a sensor chip array for a unified multispectral focal plane for the Multispectral Linear Array (MLA) instrument. The involved concept of sensing multispectral earth resources imagery through the use of spectral filters deposited directly on a single row of silicon charge-coupled device (CCD) chips has been considered for a number of years. A simplified focal plane was designed after a number of experiments. Technology considerations regarding the design of the multispectral focal plane are discussed. Experimental data are presented which show that the arising problems have been or can be solved.

Hall, J. A.↗

Multiwavelength infrared focal plane array detector

A multiwavelength focal plane array infrared detector is included on a common substrate having formed on its top face a plurality of In.sub.x Ga.sub.1-x As (x.ltoreq.0.53) absorption layers, between each pair of which a plurality of InAs.sub.y P.sub.1-y (y<1) buffer layers are formed having substantially increasing lattice parameters, respectively, relative to said substrate, for preventing lattice mismatch dislocations from propagating through successive ones of the absorption layers of decreasing bandgap relative to said substrate, whereby a plurality of detectors for detecting different wavelengths of light for a given pixel are provided by removing material above given areas of successive ones of the absorption layers, which areas are doped to form a pn junction with the surrounding unexposed portions of associated absorption layers, respectively, with metal contacts being formed on a portion of each of the exposed areas, and on the bottom of the substrate for facilitating electrical connections thereto.

Forrest, Stephen R.↗

Spitzer Space Telescope: Focal Plane Survey Final Report: IRAC - Appendix B:

This final report summarizes the results and accuracies of the Spitzer Space Telescope focal plane survey. Accuracies achieved are compared to the focal plane survey calibration requirements put forth in the SIRTF IOC-SV Mission Plan [14] and pre-flight predictions made in [2]. The results of this focal plane survey are presently being used to support in-flight precision pointing, precision incremental offsets, IRS peakup array calibration, and ground pointing reconstruction...

kalman filtering↗

Test chamber for low-background IR focal plane testing

A unique and versatile vacuum chamber has been designed for JPL's IR Focal Plane Technology Group. This chamber is equipped with multiple ports for cryogen and electrical vacuum feedthroughs, pumping units, vacuum gages, sources, and detector camera heads. The design incorporates a liquid-nitrogen-cooled optical table and radiation shield for low-background IR detector testing. Focal planes can be tested at temperatures ranging from 300 K to that of liquid helium. This paper describes the design and construction of this low-background IR focal plane test chamber and discusses some of its distinctive features. An analysis of the test chamber's performance is also presented.

Staller, Craig↗