At least 37 records · Page 2

The effect of relative humidity on eddy covariance latent heat flux measurements and its implication for partitioning into transpiration and evaporation

While the eddy covariance (EC) technique is a well-established method for measuring water fluxes (i.e., evaporation or 'evapotranspiration’, ET), the measurement is susceptible to many uncertainties. One such issue is the potential underestimation of ET when relative humidity (RH) is high (> 70%), due to low-pass filtering with some EC systems. Yet, this underestimation for different types of EC systems (e.g. open-path or closed-path sensors) has not been characterized for synthesis datasets such as the widely used FLUXNET2015 dataset. Here, we assess the RH-associated underestimation of latent heat fluxes (LE, or ET) from different EC systems for 163 sites in the FLUXNET2015 dataset. We found that the LE underestimation is most apparent during hours when RH is higher than 70%, predominantly observed at sites using closed-path EC systems, but the extent of the LE underestimation is highly site-specific. We then propose a machine learning based method to correct for this underestimation, and compare it to two energy balance closure based LE correction approaches (Bowen ratio correction, BRC, and attributing all errors to LE). Our correction increases LE by 189% for closed-path sites at high RH (> 90%), while BRC increases LE by around 30% for all RH conditions. Additionally, we assess the influence of these corrections on ET-based transpiration (T) estimates using two different ET partitioning methods. Results show opposite responses (increasing vs. slightly decreasing T-to-ET ratios, T/ET) between the two methods when comparing T based on corrected and uncorrected LE. Overall, our results demonstrate the existence of a high RH bias in water fluxes in the FLUXNET2015 dataset and suggest that this bias is a pronounced source of uncertainty in ET measurements to be considered when estimating ecosystem T/ET and WUE.

54 ENVIRONMENTAL SCIENCES↗

Eddy Correlation Flux Measurement System (ECOR) Instrument Handbook

The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO 2 ) (and methane at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s North Slope of Alaska central facility [NSA Barrow], and at the ARM Mobile Facility (AMF) deployment at Oliktok Point). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO 2 concentration. The instruments used are: a fast-response, three-dimensional (3D) wind sensor (sonic anemometer) to obtain the orthogonal wind components and the speed of sound (SOS) (used to derive the air temperature), an open-path infrared gas analyzer (IRGA) to obtain the water vapor density and the CO 2 concentration, and an open-path infrared gas analyzer (IRGA) to obtain methane density and methane flux at NSA Barrow and at the AMF deployment at Oliktok Point. The ECOR systems are deployed at the locations where other methods for surface flux measurements (e.g., energy balance Bowen ratio [EBBR] systems) are difficult to employ, primarily at the north edge of a field of crops. A surface energy balance system (SEBS) has been installed collocated with each deployed ECOR system in SGP, NSA, Tropical Western Pacific (TWP), and each of three ARM Mobile Facilities. The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. Finally, the SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.

47 OTHER INSTRUMENTATION↗

Eddy Correlation Flux Measurement System (ECOR) Instrument Handbook

The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO 2 ) at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility sites. ARM’s ECORs also historically measured methane fluxes at Utqiaġvik and Oliktok Point, Alaska. The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO 2 concentration.

54 ENVIRONMENTAL SCIENCES↗

Heat flux measurements

This paper discusses a new automated, computer-controlled heat flux measurement facility. Continuous transient and steady-state surface heat flux values varying from about 0.3 to 6 MW/sq m over a temperature range of 100 to 1200 K can be obtained in the facility. An application of this facility is the development of heat flux gages for continuous fast transient surface heat flux measurement on turbine blades operating in Space Shuttle main engine turbopumps. The facility is also useful for durability testing at fast temperature transients.

Liebert, Curt H.↗

Air-mass flux measurement system using Doppler-shifted filtered Rayleigh scattering

An optical system has been investigated to measure mass flux distributions in the inlet of a high speed air-breathing propulsion system. Rayleigh scattered light from air is proportional to the number density of molecules and hence can be used to ascertain the gas density in a calibrated system. Velocity field measurements are achieved by spectrally filtering the elastically-scattered Doppler-shifted light with an absorbing molecular filter. A novel anamorphic optical collection system is used which allows optical rays from different scattering angles, that have different Doppler shifts, to be recorded separately. This is shown to obviate the need to tune the laser through the absorption to determine velocities, while retaining the ability to make spatially-resolved measurements along a line. By properly selecting the laser tuning and filter parameters, simultaneous density measurements can be made. These properties are discussed in the paper and experiments demonstrating the velocimetry capability are described.

Shirley, John A.↗

Airborne flux measurements of trace species in an Arctic boundary layer

In situ airborne flux values for O3, CO, an CH4 over selected wetlands of Alaska are reported, and airborne CH4 flux measurements are presented for the first time. The source/sink distribution over the Yukon-Kuskokwim Delta (YKD) is qualitatively correlated with surface vegetation type. The CH4 source strength over the YKD ranged from 25 to 85 mg/sq m/d. A spatially averaged, seasonally adjusted source strength of 51 mg/sq m/d was established for the YKD. Indirect CH4 flux estimates obtained over the Alaskan North Slope indicate a much lower source strength. The global CH4 emission from tundra are estimated to be 44 Tg/a at an upper limit. Airborne CO flux measurements over the YKD indicate low negative flux values over the coastal areas, while some positive fluxes were observed in the inland sparsely forested regions. An inspection of the cospectrum of CO with vertical velocity for sample runs in coastal areas indicate the possibility of in situ photochemical destruction/production of CO.

Ritter, John A.↗

Supersonic Mass Flux Measurements via Tunable Diode Laser Absorption and Non-Uniform Flow Modeling

Measurements of mass flux are obtained in a vitiated supersonic ground test facility using a sensor based on line-of-sight (LOS) diode laser absorption of water vapor. Mass flux is determined from the product of measured velocity and density. The relative Doppler shift of an absorption transition for beams directed upstream and downstream in the flow is used to measure velocity. Temperature is determined from the ratio of absorption signals of two transitions (lambda(sub 1)=1349 nm and lambda(sub 2)=1341.5 nm) and is coupled with a facility pressure measurement to obtain density. The sensor exploits wavelength-modulation spectroscopy with second-harmonic detection (WMS-2f) for large signal-to-noise ratios and normalization with the 1f signal for rejection of non-absorption related transmission fluctuations. The sensor line-of-sight is translated both vertically and horizontally across the test section for spatially-resolved measurements. Time-resolved measurements of mass flux are used to assess the stability of flow conditions produced by the facility. Measurements of mass flux are within 1.5% of the value obtained using a facility predictive code. The distortion of the WMS lineshape caused by boundary layers along the laser line-of-sight is examined and the subsequent effect on the measured velocity is discussed. A method for correcting measured velocities for flow non-uniformities is introduced and application of this correction brings measured velocities within 4 m/s of the predicted value in a 1630 m/s flow.

Chang, Leyen S.↗

Development of airborne eddy-correlation flux measurement capabilities for reactive oxides of nitrogen

This research is aimed at producing a fundamental new research tool for characterizing the source strength of the most important compound controlling the hemispheric and global scale distribution of tropospheric ozone. Specifically, this effort seeks to demonstrate the proof-of-concept of a new general purpose laser-induced fluorescence based spectrometer for making airborne eddy-correlation flux measurements of nitric oxide (NO) and other reactive nitrogen compounds. The new all solid-state laser technology being used in this advanced sensor will produce a forerunner of the type of sensor technology that should eventually result in highly compact operational systems. The proof-of-concept sensor being developed will have over two orders-of-magnitude greater sensitivity than present-day instruments. In addition, this sensor will offer the possibility of eventual extension to airborne eddy-correlation flux measurements of nitrogen dioxide (NO2) and possibly other compounds, such as ammonia (NH3), peroxyradicals (HO2), nitrateradicals (NO3) and several iodine compounds (e.g., I and IO). Demonstration of the new sensor's ability to measure NO fluxes will occur through a series of laboratory and field tests. This proof-of-concept demonstration will show that not only can airborne fluxes of important ultra-trace compounds be made at the few parts-per-trillion level, but that the high accuracy/precision measurements currently needed for predictive models can also. These measurement capabilities will greatly enhance our current ability to quantify the fluxes of reactive nitrogen into the troposphere and significantly impact upon the accuracy of predictive capabilities to model O3's distribution within the remote troposphere. This development effort also offers a timely approach for producing the reactive nitrogen flux measurement capabilities that will be needed by future research programs such as NASA's planned 1999 Amazon Biogeochemistry and Atmospheric Chemistry Experimental portion of LBA.

Bradshaw, John↗

Heat flux measuring system Patent

Heat flux sensor adapted for mounting on aircraft or spacecraft to measure aerodynamic heat flux inflow to aircraft skin

Baxter, R. D.↗

Patch-level chamber-based CH4 and CO2 flux measurements in freshwater and salt marshes of coastal Louisiana

This dataset contains chamber-based carbon dioxide and methane flux measurements from ecohydrological patches in two coastal wetlands in Louisiana (within the footprint of AmeriFlux sites US-LA2 and US-LA3). Measurements span four patches, two per wetland. At the freshwater marsh (US-LA2), patches were dominated by Sagittaria lancifolia or co-dominated by Sagittaria lancifolia and Typha latifolia. At the salt marsh site (US-LA3), patches were dominated by Spartina alterniflora or Juncus roemerianus. Flux measurements included (i) wetland surface-level measurements encompassing the entire soil-water-vegetation column and (ii) soil-water surface chamber measurements that excluded emergent vegetation. At US-LA3, open-water pools were common and were also measured as a patch type. With this data we aimed to assess differences in gas flux pathways within ecohydrological patches across different wetland types. Files can be read in any program or code typical of processing .csv file types. "PatchChambers_LA2LA3.csv" covers flux data from patch level chambers which includes bulk CO2/CH4 flux encompassing water, soil, and vegetation within each chamber. "Water_Soil_SurfaceChamber_LA2LA3.csv" has CO2/CH4 flux data from chambers measuring only the water-soil surface without the effects of vegetation. Metadata can be found in the similarly named files for each data sheet ("xxxx_md.csv").

54 ENVIRONMENTAL SCIENCES↗

Mass flux measurements and correlations in the back flow region of a nozzle plume.

A series of tests were conducted to measure the mass flux in the far field of a nozzle plume in a high vacuum with emphasis on the back flow region. The measurements presented in this report provide fairly accurate data for off-axis angles as large as 140 deg (i.e., the back flow region). The tests utilized five different nozzles. Parameters such as expansion ratio, throat diameter, nozzle lip shape, and plenum (chamber) pressure were varied. Carbon dioxide and nitrogen gases were passed through, and mass flux measurements were taken using quartz crystal microbalances in as many as nine different locations relative to the test nozzle. The tests resulted in a large matrix of data that were correlated and compared to existing prediction theories. Several conclusions with respect to the effect of nozzle and gas parameters on the amount of back flow mass flux are offered, and it was demonstrated that gaseous mass fluxes, which are not predictable by present theories, are encountered in the region behind the nozzle exit plane.

Chirivella, J. E.↗

Molecular flux measurements in the back flow region of a nozzle plume

A series of tests were conducted to measure the mass flux in the far field of a nozzle plume in a high vacuum with emphasis on the back flow region. The measurements presented provided fairly accurate data for off-axis angles as large as 140 deg (i.e., in the back flow region). This region, since it is well behind the exit plane, is of paticular interest to those concerned with instrument contamination. Usually sensitive spacecraft surfaces are located in the region affected by the back flow. Parameters such as expansion ratio, throat diameter, nozzle lip shape, and plenum (chamber) pressure were varied, carbon dioxide and nitrogen gases were flowed and mass flux measurements were taken using quartz crystal microbalances in as many as nine different locations relative to the tests nozzle. Several conclusions with respect to the effect of nozzle and gas parameters on the amount of back flow mass flux are offered, and it was demonstrated that gaseous mass fluxes, which are not predictable by present theories, are encountered in the region behind the nozzle exit plane. This knowledge is significant if materials incompatible with the gaseous exhaust products are used in this region.

Chirivella, J. E.↗

Momentum Flux Measuring Instrument for Neutral and Charged Particle Flows

An instrument to measure the momentum flux (total pressure) of plasma and neutral particle jets onto a surface has been developed. While this instrument was developed for magnetized plasmas, the concept works for non-magnetized plasmas as well. We have measured forces as small as 10(exp -4) Newtons on a surface immersed in the plasma where small forces are due to ionic and neutral particles with kinetic energies on the order of a few eV impacting the surface. This instrument, a force sensor, uses a target plate (surface) that is immersed in the plasma and connected to one end of an alumina rod while the opposite end of the alumina rod is mechanically connected to a titanium beam on which four strain gauges are mounted. The force on the target generates torque causing strain in the beam. The resulting strain measurements can be correlated to a force on the target plate. The alumina rod electrically and thermally isolates the target plate from the strain gauge beam and allows the strain gauges to be located out of the plasma flow while also serving as a moment arm of several inches to increase the strain in the beam at the strain gauge location. These force measurements correspond directly to momentum flux and may be used with known plasma conditions to place boundaries on the kinetic energies of the plasma and neutral particles. The force measurements may also be used to infer thrust produced by a plasma propulsive device. Stainless steel, titanium, molybdenum, and aluminum flat target plates have been used. Momentum flux measurements of H2, D2, He, and Ar plasmas produced in a magnetized plasma device have been performed.

Chavers, Greg↗

Multiple-Point Mass Flux Measurement System Using Rayleigh Scattering

A multiple-point Rayleigh scattering diagnostic is being developed to provide mass flux measurements in gas flows. Spectroscopic Rayleigh scattering is an established flow diagnostic that has the ability to provide simultaneous density, temperature, and velocity measurements. Rayleigh scattered light from a focused 18 Watt continuous-wave laser beam is directly imaged through a solid Fabry-Perot etalon onto a CCD detector which permits spectral analysis of the light. The spatial resolution of the measurements is governed by the locations of interference fringes, which can be changed by altering the etalon characteristics. A prototype system has been used to acquire data in a Mach 0.56 flow to demonstrate feasibility of using this system to provide mass flux measurements. Estimates of measurement uncertainty and recommendations for system improvements are presented

Mielke, Amy F.↗

Absolute photon-flux measurements in the vacuum ultraviolet

Absolute photon-flux measurements in the vacuum ultraviolet have extended to short wavelengths by use of rare-gas ionization chambers. The technique involves the measurement of the ion current as a function of the gas pressure in the ion chamber. The true value of the ion current, and hence the absolute photon flux, is obtained by extrapolating the ion current to zero gas pressure. Examples are given at 162 and 266 A. The short-wavelength limit is determined only by the sensitivity of the current-measuring apparatus and by present knowledge of the photoionization processes that occur in the rate gases.