Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Fluctuation diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A novel method for thermal noise reduction, enabling measurements of broadband, low-amplitude electron temperature fluctuations using individual radiometer channels

A new analysis method has been developed for measurements of broadband, low-amplitude turbulent electron temperature fluctuations in fusion plasmas using individual radiometer channels of a correlation electron cyclotron emission diagnostic. This method takes advantage of differences in the correlation time of thermal noise compared to the correlation time of plasma fluctuations in fusion reactors. The validation of this single-channel method is demonstrated using comparisons with the standard dual-channel radiometer spectral decorrelation method for measurements of turbulent electron temperature fluctuations in the core and edge of low confinement (L), improved confinement (I), and high confinement (H)-mode plasmas at the ASDEX Upgrade tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Gyrokinetic profile prediction and validation of a negative triangularity plasma in ASDEX Upgrade

In this work, gyrokinetic simulations are performed with the CGYRO code (Candy et al 2016 J. Comput. Phys. 324 73–93) for a negative triangularity H-mode plasma in ASDEX Upgrade, and compared with experimental measurements. The PORTALS framework (Rodriguez-Fernandez et al 2024 Nucl. Fusion 64 076034) is used to accelerate the prediction of kinetic profiles for this plasma, using surrogate modeling and Bayesian optimization. Ion heat flux, electron heat flux, and electron particle flux are simultaneously matched across the simulated radial regime of the plasma (normalized radius $r/a = 0.35-0.90$), and the resulting ion temperature, electron temperature, and electron density profiles match well with the experimental profile data within this radial range. A synthetic Correlation Electron Cyclotron Emission diagnostic is applied to find well-matched electron temperature fluctuation properties between simulation and experiment. The flux-matched profiles provide a basis for investigation of the turbulence nature across the plasma radius, revealing the dominance of Trapped Electron Mode turbulence at $r/a = 0.35$, the dominance of Ion Temperature Gradient turbulence at $r/a = 0.55$, 0.75, and 0.83, and an instability boundary at $r/a = 0.90$.

gyrokinetic simulation

Design of radial interferometer–polarimeter for internal magnetic and density fluctuation measurements at multiple space–time scales in the National Spherical Torus Experiment-Upgrade (NSTX-U)

A Faraday-effect radial interferometer–polarimeter is designed for the National Spherical Torus Experiment-Upgrade (NSTX-U) to measure multiscale magnetic and density fluctuations critical to understanding fusion plasma confinement and stability, including those originating from magnetohydrodynamic instabilities, energetic particle-driven modes, and turbulence. The diagnostic will utilize the three-wave technique with 5 MHz bandwidth to simultaneously measure line-integrated magnetic and density fluctuations up to the ion-cyclotron frequency. Probe beams will be launched radially from the low-field side at the NSTX-U midplane, where the measured Faraday fluctuations mainly correspond to radial magnetic fluctuations that directly link to magnetic transport. A correlation technique will be employed to reduce the measurement noise to below 0.01° enabling detection of small amplitude fluctuations. Two toroidally displaced chords with 7° separation will be installed to measure toroidal mode numbers up to n = 25 for mode identification. Finally, solid-state microwave sources operating at 321 μm (935 GHz) will be used to minimize the impact of the Cotton–Mouton effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Applicability of alkali beam emission spectroscopy on NSTX-U

Understanding fast pedestal dynamics and turbulent transport in the edge and scrape-off layer (SOL) plasma of spherical tokamaks is crucial for the design and operation of future fusion reactors. The alkali beam emission spectroscopy diagnostic technique offers a means to measure the absolute electron density radial profile and fluctuation amplitude in these regions. Here, in this study, we demonstrate that injecting a sodium neutral beam radially into the plasma and analyzing the light emission from its 3p–3s atomic transition using near-orthogonal viewing angles allows for accurate measurement of the electron density profile and fluctuations in the National Spherical Torus Experiment (NSTX) Upgrade spherical tokamak. Our findings indicate a peak signal-to-noise ratio of 118 in the pedestal and 12 in the SOL under typical NSTX plasma conditions. The spatial resolution for the electron density profile is estimated to be between 2 and 8 mm, while for fluctuation measurements, it ranges from 12 to 15 mm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Electromagnetic Analysis of ITER Electron Cyclotron Emission Components and Support Structures for the Preliminary Design Review

The ITER electron cyclotron emission (ECE) diagnostic system is located at Design Shield Module (DSM) 2, Equatorial Port (EP) 9 to measure electron temperature profile and electron temperature fluctuations and also to assess nonthermal electron distributions via the oblique view. Therefore, ECE has both radial and oblique views with two couples of mirrors for two different optical views. This ECE diagnostic system shall be exposed to significant power due to unabsorbed electron cyclotron heating power in the plasma. It shall also receive large electromagnetic (EM) loads up to 100 MN/m 3 force density due to the eddy currents generated by the short 16-ms transient plasma disruption. The global EM models of EP12 and EP11 with the worst case of plasma disruption Major Disruption Downward Exponential 16 ms Category III (MD_DW_EXP16MS_CATIII) have been provided by ITER. However, the support structure for these critical components, including four mirrors, is still under the design and development phase, especially during the period of preliminary design reviews (PDRs). For those small in-vessel components that are not modeled explicitly for the PDRs, we can extract the magnetic field (B) data and flux variations (dB/dt) at those locations from the global model and then use the B and dB/dt method to calculate the eddy currents, EM forces, and torques on those components in the local submodels. In conclusion, this paper will present the detailed PDR EM analysis results of the ECE components and support structures.

Electromagnetic

Study of the connected four-point correlation function of galaxies from the DESI Data Release 1 luminous red galaxy sample

We present a measurement of the non-Gaussian four-point correlation function (4PCF) from the DESI DR1 luminous red galaxy (LRG) sample. For the gravitationally induced parity-even 4PCF, we detect a signal with a significance of 14.7⁢𝜎 using our fiducial setup. We assess the robustness of this detection through a series of validation tests, including auto and cross-correlation analyses, sky partitioning across multiple patch combinations, and variations in radial scale cuts. Due to the low completeness of the sample, we find that differences in fiber assignment implementation schemes can significantly impact estimation of the covariance and introduce biases in the data vector. After correcting for these effects, all tests yield consistent results. This is one of the first measurements of the connected 4PCF on the DESI LRG sample; the good agreement between the simulation and the data implies that the amplitude of the density fluctuation inferred from the connected 4PCF is consistent with the Planck Λ⁢ CDM cosmology. The methodology and diagnostic framework established in this work provide a foundation for interpreting parity-odd 4PCF.

Cosmology

Electromagnetic Analysis of ITER Electron Cyclotron Emission Model

The ITER electron cyclotron emission (ECE) diagnostic system is located at diagnostics shielding module 2 (DSM2), equatorial port 9 (EP9), to measure electron temperature profile and electron temperature fluctuations, and also assess nonthermal electron distributions via the oblique view. Therefore, ECE has both radial and oblique views with two hot sources for calibration and two couples of mirrors for two different optical views. It shall receive that the large electromagnetic (EM) loads up to 100-MN/m3 force density due to the eddy currents on the copper mirrors generated by the short transient plasma disruption. The simplified EM analysis model using magnetic field ( B ) data and flux variations (dB/dt) method based on the worst case of plasma disruption, MD_DW_EXP16MS_CATIII, has been developed to calculate the force and moments for each ECE component and support structure for EP9 DSM2 Bay2 and Bay3. The B and dB/dt methods use the constant B and dB/dt assumed for each local bay space, but the real B and dB/dt are basically varied along the radial direction of each bay. The complex global model with the local ECE components and support structure using Maxwell transient has been developed to do EM analysis to compare the results of the B and dB/dt models. The volumetric EM force density of the whole ECE components and support structure can be used for the subsequent structural analysis. In conclusion, combined with the thermal and nuclear loads and seismic and initial loads, the ECE integration analysis can be finalized for the operation case.

Fang, J. [Princeton Plasma Physics Laboratory (PPP

Analysis of runaway electron driven whistler wave instability experiments

Data acquired on the DIII-D tokamak were analyzed. The data are from experiments that were conducted to study an instability that is driven unstable by intense populations of electrons with MeV energies that are known as runaway electrons. The instability is a type of plasma wave called a whistler wave that occurs at frequencies above the ion cyclotron frequency but well below the electron cyclotron frequency. The waves were measured by magnetic fluctuation coils that are embedded in the DIII-D vacuum vessel wall. After upgrades to this diagnostic were completed, new experiments were conducted on July 13, 2020 in order to measure the toroidal mode number of the whistler waves and to extend the frequency of the detected waves. Through the use of mixers, instability between 600-700 MHz was detected. (The initial experiments only measured up to 200 MHz.) Analysis of the data was led by Hari Choudhury, a PhD student at Columbia University. Mr. Choudhury has submitted two papers for publication that include contributions by UC Irvine (UCI) Professor Heidbrink and his graduated PhD student Genevieve DeGrandchamp: “Detailed Characterization of Runaway Electron Driven Whistler Waves in Low-Density DIII-D Discharges” and “First Demonstration of Resonant Pitch-Angle Scattering of Relativistic Electrons by Externally-Launched Helicon Waves.” The first paper, which has been submitted to Physics of Plasmas, has significant contributions to both the data and the interpretation by UCI scientists. In contrast, UCI contributions to the second paper, which has been submitted to Physical Review Letters, are relatively minor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Emulation of quantum correlations by classical dynamics in a spin-$\frac{1}{2}$ Heisenberg chain

We simulate the dynamical spin structure factor (DSSF) 𝒮⁡(𝑞,𝜔) of the spin-1/2 Heisenberg antiferromagnetic chain using classical simulations. By employing Landau-Lifshitz Dynamics, we emulate quantum correlations through temperature-dependent corrections, including rescaling of magnetic dipoles and renormalization of exchange interactions. Here, our results closely match Quantum Monte-Carlo calculations for 𝑘 B⁢ 𝑇/𝐽≳1, extending the applicability of classical dynamics to the challenging case of gapless excitations. At higher temperatures, our simulations comply with general predictions for uncorrelated paramagnetic fluctuations in the infinite temperature limit. Entanglement witnesses derived from the quantum-equivalent DSSF act as sensitive diagnostics for the quantum-to-classical crossover. Their reliability stems from their dependence on spectral features alone, enabling classical dynamics to emulate quantum thresholds without genuine entanglement. This framework also reproduces transverse spin correlations in finite magnetic fields, in agreement with quantum simulations. Together, our results establish quantum-corrected classical dynamics as a scalable and predictive tool for interpreting scattering experiments and exploring quantum correlations in strongly correlated spin systems.

Inelastic neutron scattering

Experimental investigation of H-mode pedestal turbulence using a charge exchange imaging diagnostic system at DIII-D

Microtearing modes (MTMs) (ω ~ ω de k θ ρ s ~ 0.1, k r ρ s ~ 0.3 – 1.0) are predicted to cause substantial electron thermal transport in the H-mode pedestal, limiting fusion performance on high-power devices. Localized 2D measurements of low-to-intermediate wavenumber density fluctuations in the edge of DIII-D H-mode plasmas suggest the presence of temporally intermittent or ‘bursting’ MTMs during the inter-ELM cycle in the steep gradient region. These measurements are obtained using a new intermediate radial resolution multichannel Charge eXchange Imaging (CXI) diagnostic that analyzes the intensity of the CVI emission at 529 nm. The mode is peaked near ρ = 0.97 with a radial full-width half maximum of 1.5–2.0 cm and a normalized density fluctuation amplitude peak of $\frac{dn_C}{n_C}$ ~ 5%, peaking near 60 kHz in the lab frame. The mode additionally features a broad spectral width from 30 to 180 kHz and propagates in the electron diamagnetic direction in the plasma frame. CXI measurements taken during discharges with high density and current ramps provide evidence that MTMs become unstable at finite collisionality and remain at nearly the same location in ρ-space despite scanning of rational surface position. This indicates that the location of the peak in the electron diamagnetic frequency is a stronger driving force than individual rational surfaces.

DIII-D

Heavy ion beam probe for Wendelstein 7-X measurement capabilities as projected through its design

A heavy ion beam probe (HIBP) diagnostic is being developed for studies of plasma equilibrium and turbulence in the optimized Wendelstein 7-X (W7-X) stellarator. Operation of W7-X has experimentally demonstrated that its optimized magnetic field results in improved neoclassical particle confinement and, as a result, turbulence is the predominant cause of energy transport. The HIBP will have the unique ability to provide experimental data needed to complement models of both neoclassical and turbulent transport. It will acquire direct measurements in the W7-X plasma interior of the electric potential (needed for understanding ambipolar particle flux) and fluctuations of electron density and potential (needed for understanding turbulence). The HIBP for W7-X will inject singly charged ion beams with energies of up to 2 MeV and is designed to access the upper cross section of the W7-X plasma. We use trajectory simulations to illustrate the plasma coverage that the diagnostic can achieve in the reference magnetic configurations of W7-X. We calculate beam signal levels, discuss anticipated measurement sensitivity of broadband fluctuations of electron density and plasma potential, and show how they depend on plasma density. We also discuss the diagnostic sensitivity to equilibrium plasma potential.

Instruments & Instrumentation

First fluctuation measurements using an Imaging Neutral Particle Analyzer on DIII-D

A recent upgrade to the Imaging Neutral Particle Analyzer (INPA) on DIII-D has allowed for the first fluctuation measurements using an INPA to be taken during a neoclassical tearing mode (NTM). The INPA signal tracked the mode over 150 ms as the mode frequency dropped to zero, capturing both the NTM with poloidal and toroidal mode numbers $m/n=2/1$ and a $3/2$ mode at double the frequency. Analysis shows that the signals originate from charge exchange events near the edge of the plasma, and relative fluctuation amplitudes are greater than 25% for the duration of the NTM. Filtered signals show frequency beating patterns that are phase-space dependent. Simulated signal is dominated by prompt transport from the neutral beams to the INPA sightline, while the contribution from the slowing down distribution is significantly lower. Simulated measurements in the range of pitches that the diagnostic is sensitive to (0.5≤|v∥/v|≤ 0.75) show the signal is dominated by trapped orbits that pass through magnetic islands near the edge of the plasma. Calculations of expected fluctuation levels show that only direct interaction with the NTM can provide the strong relative fluctuation levels seen experimentally. The prompt nature of the orbits and thin radial layer found to contribute to synthetic signals suggest INPA passive data may be used to measure the perturbations of confined orbits on a single pass through a plasma instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER

The vertical-velocity skewness in the atmospheric boundary layer without buoyancy and Coriolis effects

One of the main features of near-neutral atmospheric boundary layer (ABL) turbulence is the positive vertical velocity skewness $Sk_w$ above the roughness sublayer or the buffer region in smooth-walls. The $Sk_w$ variations are receiving renewed interest in many climate-related parameterizations of the ABL given their significance to cloud formation and to testing sub-grid schemes for Large Eddy Simulations (LES). The vertical variations of $Sk_w$ are explored here using wind tunnel and flume experiments collected above smooth, rough, and permeable-walls in the absence of buoyancy and Coriolis effects. These laboratory experiments form a necessary starting point to probe the canonical structure of $Sk_w$ as they deal with a key limiting case (i.e., near-neutral conditions). Diagnostic models based on cumulant expansions, realizability constraints, and constant mass flux approach routinely employed in the convective boundary layer as well as prognostic models based on third-order budgets are used to explain variations in $Sk_w$ for the idealized laboratory conditions. The failure of flux-gradient relations to model $Sk_w$ from the gradients of the vertical velocity variance σ$_w^2$ are explained and corrections based on models of energy transport offered. Novel links between the diagnostic and prognostic models are also featured, especially for the inertial term in the third-order budget of the vertical velocity fluctuation. The co-spectral properties of w′/σ w vs w′ 2 /σ$_w^2$ are also presented for the first time to assess the dominant scales governing $Sk_w$ in the inner and outer layers, where w′ is the fluctuating vertical velocity and σ w is the vertical velocity standard deviation.>

Boundary layer flow

Overview of recent turbulence studies across multiple confinement modes at the ASDEX Upgrade tokamak using the Correlation Electron Cyclotron Emission diagnostic

This work presents an overview of recent and ongoing experimental measurements of core and edge turbulence across multiple confinement regimes using the Correlation Electron Cyclotron Emission (CECE) diagnostic at the ASDEX Upgrade (AUG) tokamak. A common goal among these investigations is to identify how the properties of the turbulent electron temperature fluctuations measured by CECE influence and regulate the unique transport characteristics of each confinement regime, including L-mode, I-mode, ELMy H-mode, and ELM-free H-mode. Optics and signal processing methods to aid in the analysis and interpretation of experimental turbulence results are also presented. These methods, and particularly the down-sampling and ensemble averaging method, are relevant to a wide variety of fusion and non-fusion applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

A supersymmetric SYK model with a curious low energy behavior

We consider N = 2,4 supersymmetric SYK models that have a peculiar low energy behavior, with the entropy going like S = S 0 + (constant)T a , where a ≠ 1. The large N equations for these models are a generalization of equations that have been previously studied as an unjustified truncation of the planar diagrams describing the BFSS matrix quantum mechanics or other related matrix models. Here we reanalyze these equations in order to better understand the low energy physics of these models. We find that the scalar fields develop large expectation values which explore the low energy valleys in the potential. The low energy physics is dominated by quadratic fluctuations around these values. These models were previously conjectured to have a spin glass phase. We did not find any evidence for this phase by using the usual diagnostics, such as searching for replica symmetry breaking solutions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

X-ray thermal diffuse scattering as a texture-robust temperature diagnostic for dynamically compressed solids

We present a model of x-ray thermal diffuse scattering (TDS) from a cubic polycrystal with an arbitrary crystallographic texture, based on the classic approach of Warren [B. E. Warren, Acta Crystallogr. 6, 803 (1953)]. We compare the predictions of our model with femtosecond x-ray diffraction patterns gathered from ambient and dynamically compressed rolled copper foils obtained at the High Energy Density instrument of the European X-Ray Free-Electron Laser facility and find that the texture-aware TDS model yields more accurate results than does the conventional powder model owed to Warren. Nevertheless, we further show: with sufficient angular detector coverage, the TDS signal is largely unchanged by sample orientation and in all cases strongly resembles the signal from a perfectly random powder; shot-to-shot fluctuations in the TDS signal resulting from grain-sampling statistics are at the percent level, in stark contrast to the fluctuations in the Bragg-peak intensities (which are over an order of magnitude greater); and TDS is largely unchanged even following texture evolution caused by compression-induced plastic deformation. We conclude that TDS is robust against texture variation, making it a flexible temperature diagnostic applicable just as well to off-the-shelf commercial foils as to ideal powders.

Crystal lattices

Injection, confinement, and diagnosis of electrons and positrons in a permanent magnet dipole trap

Abstract Prerequisites for the goal of studying long-lived, magnetically confined, electron–positron pair plasmas in the laboratory include the injection of both species into the trap, long trapping times, and suitable diagnostic methods. Here we report recent progress on these tasks achieved in a simple dipole trap based on a supported permanent magnet. For the injection of electrons, both an $$\textbf{E}\times B$$ E × B drift technique (of a $$\sim $$ ∼ 2– $$\upmu $$ μ A, 6-eV beam) and “edge injection” (from a filament emitting a few mA and biased to some tens of volts) have been demonstrated; the former is suitable for low-density beams with smaller spatial and velocity spreads, while the latter employs fluctuations arising from collective behavior. To diagnose the edge-injected electrons, image potentials and currents induced on a wall probe, the magnet case, and wall electrodes were measured. Confinement of drift-injected positrons, measured experimentally, exhibited at least two well-separated timescales. Simulations reproduced this qualitatively, using a simple model of elastic collisions with residual background gas, and point to small adjustments for increasing trapping times. In a major upgrade to diagnostic capabilities, 25 bismuth germanate detectors, placed in three reentrant ports, are able to localize annihilation gammas, which will be used in future experiments to distinguish between different loss channels. Graphical abstract

von der Linden, J. (ORCID:0000000327477813)