Transient Simulation of a 1MWth Test Bed of an Integrated Particle-Based CSP Plant Driving and sCO2 Flow Loop.
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
While regulators, the scientific community, and MSR developers still lack access to literature data on the thermal properties of clean fuel salts, even less information is available on the properties of fuel salts containing impurities. It is essential to understand, benchmark, and predict crucial data on the changes in thermal properties of fuel salt systems due to impurities arising from moisture, corrosion, and reactor operation (i.e., fission products). This research focuses on two actinide fuel salts (1) to investigate a worst-case scenario buildup of actinide fission product in a NaCl-UCl3 eutectic fuel salt and (2) to investigate NaCl-PuCl3 eutectic salt after 1000 hours of operation in a natural circulation flow loop flow to determine if corrosion or atmospheric (moisture/oxygen) products are present. For the first salt, a conservative assumption or worst-case scenario, for fission product buildup in a fuel salt was investigated by adding PuCl3 to eutectic 67 mol% NaCl – 33 mol% UCl3 salt resulting in a ternary salt having a composition of 61 mol% NaCl – 30 mol% UCl3 – 9mol% PuCl3. Addition of PuCl3 to eutectic NaCl-UCl3 resulted in a ternary salt that had a higher melting temperature than either the NaCl-PuCl3 or NaCl-UCl3 binary eutectic mixture. Addition of PuCl3 also resulted in an increase in density which was expected. The second salt was extracted from a micro loop. The composition of the fuel (primary) salt prior to flow loop operations was determined to be 64 mol% NaCl – 36 mol% PuCl3, however, the post-flow loop salt showed increased levels of MgCl2 and NaCl changing the salt composition to 10 mol% MgCl2 – 63mol% NaCl – 26mol% PuCl3) indicating the primary salt interacted with the rinse salt. Analysis of the post flow loop salt detected low concentrations of Al, Ni, Co, Nb, and Zr, most likely corrosion products from the flow loop material of construction. Contamination of the fuel salt (with the rinse salt NaCl-MgCl2) decreased the density by approximately 10% and reduced the onset of melting temperature by 50 °C, from 451 °C to approximately 400 °C. Results from the fission product simulated salt (61 mol% NaCl – 30 mol% UCl3 – 9mol% PuCl3) and the corrosion product salt (10 mol% MgCl2 – 63mol% NaCl – 26mol% PuCl3) will be included in two separate manuscripts for submission to peer-reviewed journals.
A series of tests has been performed on a four-port wave rotor suitable for use as a topping stage on a gas turbine engine, to measure the overall pressure ratio obtainable as a function of temperature ratio, inlet mass flow, loop flow ratio, and rotor speed. The wave rotor employed an open high pressure loop that is the high pressure inlet flow was not the air exhausted from the high pressure outlet, but was obtained from a separate heated source, although the mass flow rates of the two flows were balanced. This permitted the choice of a range of loop-flow ratios (i.e., ratio of high pressure flow to low pressure flow), as well as the possibility of examining the effect of mass flow imbalance. Imbalance could occur as a result of leakage or deliberate bleeding for cooling air. Measurements of the pressure drop in the high pressure loop were also obtained. A pressure ratio of 1.17 was obtained at a temperature ratio of 2.0, with an inlet mass flow of 0.6 lb/s. Earlier tests had given a pressure ratio of less than 1.12. The improvement was due to improved sealing between the high pressure and low pressure loops, and a modification to the movable end-wall which is provided to allow for rotor expansion.
Chemical looping is a near-zero emission process for generating power from coal. It is based on a multi-phase gas-solid flow and has extremely challenging nonlinear, multi-scale dynamics with jumps, producing large dynamic model uncertainty, which renders traditional robust control techniques, such as linear parameter varying H ∞ design, largely inapplicable. This process complexity is addressed in the present work through the temporal and the spatiotemporal multiresolution modeling along with the corresponding model-based control laws. Namely, the nonlinear autoregressive with exogenous input model structure, nonlinear in the wavelet basis, but linear in parameters, is used to identify the dominant temporal chemical looping process dynamics. The control inputs and the wavelet model parameters are calculated by optimizing a quadratic cost function using a gradient descent method. The respective identification and tracking error convergence of the proposed self-tuning identification and control schemes, the latter using the unconstrained generalized predictive control structure, is separately ascertained through the Lyapunov stability theorem. The rate constraint on the control signal in the temporal control law is then imposed and the control topology is augmented by an additional control loop with self-tuning deadbeat controller which uses the spatiotemporal wavelet riser dynamics representation. The novelty of this work is three-fold: (1) developing the self-tuning controller design methodology that consists in embedding the real-time tunable temporal highly nonlinear, but linearly parametrizable, multiresolution system representations into the classical rate-constrained generalized predictive quadratic optimal control structure, (2) augmenting the temporal multiresolution loop by a more complex spatiotemporal multiresolution self-tuning deadbeat control loop, and (3) demonstrating the effectiveness of the proposed methodology in producing fast recursive real-time algorithms for controlling highly uncertain nonlinear multiscale processes. The latter is shown through the data from the implemented temporal and augmented spatiotemporal solutions of a difficult chemical looping cold flow tracking control problem.
A cryocooler assembly for cooling a field winding of an electrical machine having an axis of rotation is provided. The assembly includes a cryocooler and a reservoir coupled in flow communication to the cryocooler and configured to contain a cooling agent. A flow assembly is coupled in flow communication to the reservoir. The flow assembly includes a first flow loop coupled in flow communication to the reservoir; a second flow loop coupled in flow communication to the reservoir; and a plurality of flow members coupled in flow communication to the first flow loop and the second flow loop and coupled to the field winding. Each flow member is configured to thermosiphon the cooling agent in a first state from the reservoir and in a second state to the reservoir.
Flow instability thresholds in closed natural circulation loops predicted in terms of dimensionless parameters
Mass and cost are typically the two biggest challenges facing space craft designers. Active thermal control systems for crewed space-craft are typically among the more massive and costly systems on the vehicle. A study was completed evaluating three different thermal control system architectures to evaluate overall performance, mass and cost for a typical exploration mission profile. The architectures that were evaluated were 1 - a two-loop system using an internal liquid loop interfacing with an external liquid loop and flow loop with flow through radiators; 2 - a-single loop architecture with flow through radiators utilizing a regenerative heat exchanger and heater; and 3 - a single-loop architecture with heat pipe radiators. Environmental conditions, calculated for a given lunar exploration mission, and mission heat load profiles, generated based on previous Orion time lines, were evalauated through the phases of the on orbit mission. Performance for each of the architectures was evaluated along with the resultant mass of each system. Recommendations include adding a thermal topping system to lunar missions due to the extreme hot environments encountered in near-lunar approaches.
A high-pressure, high-temperature water flow loop has been designed at Idaho National Laboratory (INL) for deployment in the INL Dynamic Energy Transport and Integration Laboratory (DETAIL) within the Energy Systems Laboratory (ESL) D100 northwest high bay. This loop is the first of three thermally coupled flow loops that will comprise the Advanced Reactor Technology Integral System Test (ARTIST) facility. The ARTIST facility will ultimately include a high temperature helium loop and a liquid salt loop, in addition to the PWR loop. The high-pressure water loop will operate at Pressurized Water Reactor (PWR) conditions. It will support experimental research on nuclear-renewable hybrid energy systems as well as advanced reactor technology topics. Within DETAIL, the water flow loop will also serve as a thermal energy source, emulating a reactor system. The loop will be thermally integrated with co-located energy systems including a thermal energy transport loop, thermal energy storage system, and a 25 kW high-temperature electrolysis system for hydrogen production. DETAIL will include additional energy systems such as an integrated microgrid and renewable energy systems including solar photovoltaics. The electrically heated flow loop will be dynamically controlled to simulate nuclear fuel behavior under normal and off-normal operating conditions. DETAIL will be designed for characterization of complex system dynamics. The various components will be interfaced with Digital Real-Time Simulators for supervisory control and dynamic simulation of complete systems. The design and assembly of the high-pressure water flow loop and supporting systems has been subdivided into two Phases. Phase 1, which will be completed by the end of FY17, includes installation of cable trays and supports, electrical conduit, DI water system, drain lift station and the concrete pad for the chiller located outside of the laboratory. Phase 2 includes the detailed design and final assembly of the flow loop, supporting structures and personnel platforms, the chiller and associated piping. As of September, 2017, the final detailed design of the flow loop is complete. Funding for Phase 2 procurement, assembly, system operability checkout, shakedown testing and initial operation of the flow loop is requested for FY18.
Active closed loop flow control was successfully demonstrated on a full annulus of stator vanes in a low speed axial compressor. Two independent methods of detecting separated flow conditions on the vane suction surface were developed. The first technique detects changes in static pressure along the vane suction surface, while the second method monitors variation in the potential field of the downstream rotor. Both methods may feasibly be used in future engines employing embedded flow control technology. In response to the detection of separated conditions, injection along the suction surface of each vane was used. Injected mass flow on the suction surface of stator vanes is known to reduce separation and the resulting limitation on static pressure rise due to lowered diffusion in the vane passage. A control algorithm was developed which provided a proportional response of the injected mass flow to the degree of separation, thereby minimizing the performance penalty on the compressor system.
The primary goal of the US Department of Energy (DOE) office of Nuclear Energy Integrated Energy Systems (IES) program is to develop the tools and framework for coupling multi-scale and multi-physical thermal and electrical energy usage and storage systems. High- and low-fidelity (high–low) coupling is a key feature of multi-scale, multi-component systems and has been an important focus of research in the nuclear energy community for the past two decades. An essential feature of demonstrating the capability to couple high-fidelity and low-fidelity systems for real-time applications are surrogate/reduced order models (ROM). For the purposes of this study, surrogate models are essentially Blackbox models, typically developed using supervised Machine learning (ML) algorithms. The surrogate models can be used to mimic the response of high-fidelity models to represent large historical datasets and coupled with more general low-fidelity system models distributed as Functional Mock-up Interface (FMI) or Functional Mock-up Units (FMU) modules. The example is demonstrated with Spallation Neutron Source (SNS) First Target Station flow loop data. The flow loop is a liquid mercury loop with a pump, piping, heat exchange, and internal heat generation in the target window. This work elucidates some of the potential benefits and future needs of developing tools for high–low system coupling of energy systems.
Results of an experimental and theoretical study of factors affecting self-sustaining hydrodynamic oscillations in boiling-water loops are reported. Data on flow variables, and the effects of geometry, subcooling and pressure on the development of oscillatory behavior in a natural-circulation two-phase-flow boiling loop are included.
The research and development under this project was focused on the following three major objectives: Objective 1: Identification of critical in-vessel SMR components for remote monitoring and development of their low-order dynamic models, along with a simulation model of an integral pressurized water reactor (iPWR). Objective 2: Development of an experimental flow control loop with motor-driven valves and pumps, incorporating data acquisition and on-line monitoring interface. Objective 3: Development of stationary and transient signal processing methods for electrical signatures, machinery vibration, and for characterizing process variables for equipment monitoring. This objective includes the development of a data analysis toolbox. The following is a summary of the technical accomplishments under this project: - A detailed literature review of various SMR types and electrical signature analysis of motor-driven systems was completed. A bibliography of literature is provided at the end of this report. Assistance was provided by ORNL in identifying some key references. - A review of literature on pump-motor modeling and digital signal processing methods was performed. - An existing flow control loop was upgraded with new instrumentation, data acquisition hardware and software. The upgrading of the experimental loop included the installation of a new submersible pump driven by a three-phase induction motor. All the sensors were calibrated before full-scale experimental runs were performed. - MATLAB-Simulink model of a three-phase induction motor and pump system was completed. The model was used to simulate normal operation and fault conditions in the motor-pump system, and to identify changes in the electrical signatures. - A simulation model of an integral PWR (iPWR) was updated and the MATLAB-Simulink model was validated for known transients. The pump-motor model was interfaced with the iPWR model for testing the impact of primary flow perturbations (upsets) on plant parameters and the pump electrical signatures. Additionally, the reactor simulation is being used to generate normal operation data and data with instrumentation faults and process anomalies. A frequency controller was interfaced with the motor power supply in order to vary the electrical supply frequency. The experimental flow control loop was used to generate operational data under varying motor performance characteristics. Coolant leakage events were simulated by varying the bypass loop flow rate. The accuracy of motor power calculation was improved by incorporating the power factor, computed from motor current and voltage in each phase of the induction motor.- A variety of experimental runs were made for steady-state and transient pump operating conditions. Process, vibration, and electrical signatures were measured using a submersible pump with variable supply frequency. High correlation was seen between motor current and pump discharge pressure signal; similar high correlation was exhibited between pump motor power and flow rate. Wide-band analysis indicated high coherence (in the frequency domain) between motor current and vibration signals. - Wide-band operational data from a PWR were acquired from AMS Corporation and used to develop time-series models, and to estimate signal spectrum and sensor time constant. All the data were from different pressure transmitters in the system, including primary and secondary loops. These signals were pre-processed using the wavelet transform for filtering both low-frequency and high-frequency bands. This technique of signal pre-processing provides minimum distortion of the data, and results in a more optimal estimation of time constants of plant sensors using time-series modeling techniques.
This report describes the continuation of thermal experiments using the resistively heated target assembly within the helium flow loop at LANSCE that is described in the report, Resistively Heated Target Tests Using Helium Flow Loop, by Alexander Wass et al. In order to replicate off-normal operating scenarios of the helium cooled Mo-100 plant design disks during beam heating, an array of resistive heaters were placed within the helium flow loop, cooled via helium, and modified slightly. The resistively heated test piece is comprised of seven ceramic electric heaters with embedded thermocouples allowing temperature measurements of each heater. A total of three scenarios were performed. One unmodified scenario, and two off-normal scenarios were conducted to simulate a blocked cooling channel due to debris within the flow loop and a broken disk during in-beam heating at the Mo-99 production facility. A removable insert was placed within a cooling channel to block the flow of helium, and a resistive heater was removed to simulate a broken disk that had been evacuated from the target assembly. The inlet and outlet cooling pipe employs rectangular tubing to make a 90° bend at a radius consistent with and practical for the actual plant design.
In 2017 the Transient Reactor Test Facility was restarted after being placed in a standby state since 1994. This Test Reactor’s restart has since enabled the progressive development of new nuclear technologies within the U.S. that were previously required to outsource to other countries. While the reactor’s restart was a large feat worthy of recognition, the experimental use of its characteristics has required the further development of in-pile experimental infrastructure sufficient to support programmatic needs. This hardware have taken the form of capsule designs (compact and elongated) as well as loop concepts representing the phenomena of interest for a subset of separate effects tests desire for each respective testing campaign. The Transient Testing Program has a large-integrated effort that aligns with the U.S. Department of Energy’s current needs. This study compliments those programmatic elements by developing, fabricating and demonstrating a full-scale flowing water loop in an out-of-pile environment. The goal of this effort is to develop a pragmatic understanding of the engineering capabilities and limitations associated with geometric form-factors, metering technology, and controls logic under representative thermal hydraulic conditions that would be experienced within the TREAT reactor during an in-pile reactivity initiated accident test. The outcomes of this study result in an evaluation of the conceptual design of a comprehensive flowing water loop including objective figures of merit (FoMs) for comparing unique instrumentation and the basis for their selection during operations. These efforts directly contribute to and are required for the further advancement of transient testing capabilities within the U.S.
Chemical looping with oxygen uncoupling (CLOU) is a promising carbon capture technologies, that utilizes a dual fluidized bed interconnected by loopseals to selectively separate oxygen from ambient air. This study validated Barracuda-VR® hydrodynamic simulations of dual circulating fluidized bed. The experiments were run on a scaled-down cold-flow unit of a 100 kW dual reactor to find the quantities of interest: circulation rate, bed mass location distribution, and pressure profile. The numerical parameters of time step and grid resolution were studied to find the numeric uncertainty for the quantities of interest. The scenario parameters of flowrates, particle densities, and particle voidage were studied. The uncertainty from the model parameters of tangent-to-wall, drag multiplier, and stress model were studied. Simulation and experimental results matched over some of the parameters studied. These can be used to scale the system back to the 100 kW dual reactor and to a larger system.
Coronal transients having characteristics of a well-defined loop structure are examined, particularly with respect to temporal changes in the density and mass per unit length along the loop over periods of several days after the initial eruption. Measurements of mass distributions as a function of time are presented for eight transients, and one particular transient with a fairly simple configuration is investigated in more detail. Theoretical calculations are combined with the masses and densities derived from the observations to obtain estimates of the material flow in the transients; this flow is modeled on the assumption that magnetic forces drive and confine the loop. The flow field is found to be diverging everywhere, indicating that the density decreases in time. It is inferred that the transient legs are approximately in hydrostatic equilibrium and that most of the mass of the transient is lost from the sun during the initial phase.
Flow boiling and condensation have been identified as two key mechanisms for heat transport that are vital for achieving weight and volume reduction as well as performance enhancement in future space systems. Since inertia driven flows are demanding on power usage, lower flows are desirable. However, in microgravity, lower flows are dominated by forces other than inertia (like the capillary force). It is of paramount interest to investigate limits of low flows beyond which the flow is inertial enough to be gravity independent. One of the objectives of the Flow Boiling and Condensation Flight Experiment sets to investigate these limits for flow boiling and condensation. A two-phase flow loop consisting of a Flow Boiling Module and two Condensation Modules has been developed to experimentally study flow boiling condensation heat transfer in the reduced gravity environment provided by the reduced gravity platform. This effort supports the development of a flow boiling and condensation facility for the International Space Station (ISS). The closed loop test facility is designed to deliver the test fluid, FC-72 to the inlet of any one of the test modules at specified thermodynamic and flow conditions. The zero-g-aircraft tests will provide subcooled and saturated flow boiling critical heat flux and flow condensation heat transfer data over wide range of flow velocities. Additionally, these tests will verify the performance of all gravity sensitive components, such as evaporator, condenser and accumulator associated with the two-phase flow loop. We will present in this paper the breadboard development and testing results which consist of detailed performance evaluation of the heater and condenser combination in reduced and normal gravity. We will also present the design of the reduced gravity aircraft rack and the results of the ground flow boiling heat transfer testing performed with the Flow Boiling Module that is designed to investigate flow boiling heat transfer and Critical Heat Flux (CHF) phenomena.
Void fraction remains a crucial parameter in understanding and characterizing two-phase flow. It appears as a key variable in both heat transfer and pressure drop correlations of two-phase flows, from the macro to micro- channel scale. Void fraction estimation dictates the sizing of both evaporating and condensing phase change heat exchangers, for example. In order to measure void fraction some invasive approach is necessary. Typically, visualization is achieved either downstream of the test section or on top by machining to expose the channel. Both approaches can lead to inaccuracies. The former assumes the flow will not be affected moving from the heat exchanger surface to the transparent section. The latter distorts the heat flow path. Neutron Imaging can provide a non-invasive measurement because metals such as Aluminum are essentially transparent to neutrons. Hence, if a refrigerant is selected that provides suitable neutron attenuation; steady-state void fraction measurements in two-phase flow are attainable in-situ without disturbing the fluid flow or heat flow path. Neutron Imaging has been used in the past to qualitatively describe the flow in heat exchangers in terms of maldistributions without providing void fraction data. This work is distinguished from previous efforts because the heat exchanger has been designed and the refrigerant selected to avail of neutron imaging. This work describes the experimental flow loop that enables a boiling two-phase flow; the heat exchanger test section and downstream transparent section are described. The flow loop controls the degree of subcooling and the refrigerant flowrate. Heating cartridges embedded in the test section are employed to control the heat input. Neutron-imaged steady-state void fraction measurements are captured and compared to representative high-speed videography captured at the visualization section. This allows a qualitative comparison between neutron imaged and traditional techniques. The measurements are also compared to correlations in the literature. Preliminary void fraction images from a macro-channel flow are presented, consisting of 1 channel, 4mm wide, 4mm high and 83.32mm long. Flow regime identification is examined. The experiments were conducted at the High Flux Isotope Reactor (HFIR) Cold Guide 1D neutron imaging facility at Oak Ridge National Laboratory, Oak Ridge, TN, USA.