Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Firefly”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Several methods for concentrating bacteria in fluid samples

The sensitivities of the firefly luciferase - ATP flow system and luminol flow system were established as 300,000 E. coli per milliliter and 10,000 E. coli per milliliter respectively. To achieve the detection limit of 1,000 bacteria per milliliter previously established, a method of concentrating microorganisms using a sartorius membrane filter system is investigated. Catalase in 50% ethanol is found to be a stable luminol standard and can be used up to 24 hours with only a 10% loss of activity. The luminol reagent is also stable over a 24 hour period. A method of preparing relatively inexpensive luciferase from desiccated firefly tails is developed.

Thomas, R. R.↗

Design and feasibility study for a portable oil recovery turbopump

A portable oil recovery turbopump concept, using the Firefly module as primer mover, for the offloading of distressed tank vessels is examined. The demands to be met both in terms of the type of petroleum to be offloaded, as well as the operational requirements placed on the pump, are studied with respect to the capability of different pump configurations. Two configurations, one a centrifugal type and the other a screw type pump, are developed and evaluated. While the centrifugal configuration is found to be effective in a large proportion of tank vessel offloading situations, the screw type will be required where high viscosity cargoes are involved. The feasibility of the turbopump concept, with the Firefly module as prime mover, is established.

Source record↗

Fighting Forest Fires

Firefly is an airborne system for imaging forest fires. It uses satellite-based navigation for greater positioning accuracy and offers timeliness in fire location data delivery with on board data processing and a direct aircraft-to-fire camp communications link. Developed by Jet Propulsion Laboratory and the USFS, it has an infrared line scanner to identify fire boundaries and an infrared sensor system that can penetrate smoke to image the ground. Firefly is an outgrowth of a previous collaboration that produced FLAME, an airborne fire mapping instrument. Further refinements are anticipated by NASA and the United States Forest Service (USFS).

Source record↗

Forest Fire Mapping

The Fire Logistics Airborne Mapping Equipment (FLAME) system, mounted in a twin-engine and airplane operated by the U.S. Forest Service (USFS) of the U.S. Department of Agriculture (USDA), is an airborne instrument for detecting and pinpointing forest fires that might escape ground detection. The FLAME equipment rack includes the operator interface, a video monitor, the system's control panel and film output. FLAME's fire detection sensor is an infrared line scanner system that identifies fire boundaries. Sensor's information is correlated with the aircraft's position and altitude at the time the infrared imagery is acquired to fix the fire's location on a map. System can be sent to a fire locale anywhere in the U.S. at the request of a regional forester. USFS felt a need for a more advanced system to deliver timely fire information to fire management personnel in the decade of the 1990s. The Jet Propulsion Laboratory (JPL) conducted a study, jointly sponsored by NASA and USDA, on what advanced technologies might be employed to produce an end-to-end thermal infrared fire detection and mapping system. That led to initiation of the Firefly system, currently in development at JPL and targeted for operational service beginning in 1992. Firefly will employ satellite-reference position fixing and provide performance superior to FLAME.

Source record↗

Automated detection of bacteria in urine

A method for detecting the presence of bacteria in urine was developed which utilizes the bioluminescent reaction of adenosine triphosphate with luciferin and luciferase derived from the tails of fireflies. The method was derived from work on extraterrestrial life detection. A device was developed which completely automates the assay process.

Fleig, A. J.↗

Method of detecting and counting bacteria in body fluids

A novel method is reported for determining bacterial levels in urine samples, which method depends on the quantitative determination of bacterial adenosine triphosphate (ATP) in the presence of non-bacterial ATP. After the removal of non-bacterial ATP, the bacterial ATP is released by cell rupture and is measured by an enzymatic bioluminescent assay using an enzyme obtained from the firefly.

Chappelle, E. W.↗

Adenosine triphosphate (ATP) as a possible indicator of extraterrestrial biology

The ubiquity of adenosine triphosphate (ATP) in terrestrial organisms provides the basis for proposing the assay of this vital metabolic intermediate for detecting extraterrestrial biological activity. If an organic carbon chemistry is present on the planets, the occurrence of ATP is possible either from biosynthetic or purely chemical reactions. However, ATP's relative complexity minimizes the probability of abiogenic synthesis. A sensitive technique for the quantitative detection of ATP was developed using the firefly bioluminescent reaction. The procedure was used successfully for the determination of the ATP content of soil and bacteria. This technique is also being investigated from the standpoint of its application in clinical medicine.

Chappelle, E. W.↗

Analytical Applications of Bioluminescence and Chemiluminescence

Bioluminescence and chemiluminescence studies were used to measure the amount of adenosine triphosphate and therefore the amount of energy available. Firefly luciferase - luciferin enzyme system was emphasized. Photometer designs are also considered.

Chappelle, E. W.↗

Development of a chemiluminescent and bioluminescent system for the detection of bacteria in wastewater effluent

Automated chemiluminescent and bioluminescent sensors were developed for continuous monitoring of microbial levels in wastewater effluent. Development of the chemiluminescent system included optimization of reagent concentrations as well as two new techniques which will allow for increased sensitivity and specificity. The optimal reagent concentrations are 0.0025 M luminol and 0.0125 M sodium perborate in 0.75N sodium hydroxide before addition of sample. The methods developed to increase specificity include (1) extraction of porphyrins from bacteria collected in a filter using 0.1N NaOH - 50 percent Ethanol, and (2) use of the specific reaction rate characteristics for the different luminol catalysts. Since reaction times are different for each catalyst, the reaction can be made specific for bacteria by measuring only the light emission from the particular reaction time zone specific for bacteria. Developments of the bioluminescent firefly luciferase system were in the area of flow system design.

Thomas, R. R.↗

Designing an infrared system to map and detect wildland fires

The 'Firefly' project is developing an infrared remote sensing system to provide near real-time wildland fire information for fire management and suppression. Recent technological advances in several areas now allow the design of an end-to-end, infrared system to map and detect wildland fires. The system components will include an airborne infrared sensor, automatic onboard signal and data processing, telecommunications link, and integration into a ground data terminal. The system will provide improved performance over current systems in terms of increased timeliness of data delivery, quantifiable accuracy, data consistency, reliability, and maintainability. The system will be the next generation of wildland fire mapping and detection system for the United States Forest Service.

Nichols, J. David↗

Mapping Wildfires In Nearly Real Time

Airborne infrared-sensing system flies over wildfire as infrared detector in system and navigation subsystem generate data transmitted to firefighters' camp. There, data plotted in form of map of fire, including approximate variations of temperature. System, called Firefly, reveals position of fires and approximate thermal intensities of regions within fires. Firefighters use information to manage and suppress fires. Used for other purposes with minor modifications, such as to spot losses of heat in urban areas and to map disease and pest infestation in vegetation.

Nichols, Joseph D.↗

Infrared technology XVII; Proceedings of the Meeting, San Diego, CA, July 22-26, 1991

Recent advances in IR technologies and their application to all types of IR systems are reported focusing on the JPL Space Infrared Telescope Facility (SIRTF), JPL instruments and systems for observation of earth and the atmosphere, staring arrays and thermal imaging, ten-year updates of IR techniques, infrared in the USSR, simulation and testing, focal-plane and optical technologies, and military and scientific applications. Particular attention is given to SIRTF stray light analysis, SIRTF focal-plane technologies, long-wave IR detectors based on III-V materials, IR lidars for atmospheric remote sensing, a firefly system concept, a high-fill-factor monolithic IR image sensor, atmospheric laser-transmission tables simply generated, ORION semiconductor optical detectors, postprocessing of thermograms in IR nondestructive testing, evaluation of the IR signature of dynamic air targets, the current status of InGaAs detector arrays for 1-3 microns, a dual-band optical system for IR multicolor signal processing, and blackbody radiators for field calibration.

Andresen, Bjorn F.↗

Improvement in detection of small wildfires

Detecting and imaging small wildfires with an Airborne Scanner is done against generally high background levels. The Airborne Scanner System used is a two-channel thermal IR scanner, with one channel selected for imaging the terrain and the other channel sensitive to hotter targets. If a relationship can be determined between the two channels that quantifies the background signal for hotter targets, then an algorithm can be determined that removes the background signal in that channel leaving only the fire signal. The relationship can be determined anywhere between various points in the signal processing of the radiometric data from the radiometric input to the quantized output of the system. As long as only linear operations are performed on the signal, the relationship will only depend on the system gain and offsets within the range of interest. The algorithm can be implemented either by using a look-up table or performing the calculation in the system computer. The current presentation will describe the algorithm, its derivation, and its implementation in the Firefly Wildfire Detection System by means of an off-the-shelf commercial scanner. Improvement over the previous algorithm used and the margin gained for improving the imaging of the terrain will be demonstrated.

Sleigh, William J.↗

Sensor fusion IV: Control paradigms and data structures; Proceedings of the Meeting, Boston, MA, Nov. 12-15, 1991

Various papers on control paradigms and data structures in sensor fusion are presented. The general topics addressed include: decision models and computational methods, sensor modeling and data representation, active sensing strategies, geometric planning and visualization, task-driven sensing, motion analysis, models motivated biology and psychology, decentralized detection and distributed decision, data fusion architectures, robust estimation of shapes and features, application and implementation. Some of the individual subjects considered are: the Firefly experiment on neural networks for distributed sensor data fusion, manifold traversing as a model for learning control of autonomous robots, choice of coordinate systems for multiple sensor fusion, continuous motion using task-directed stereo vision, interactive and cooperative sensing and control for advanced teleoperation, knowledge-based imaging for terrain analysis, physical and digital simulations for IVA robotics.

Schenker, Paul S.↗

Firefighting Module

Firefly II pump module is NASA's Marshall Space Flight Center's commercial offshoot of a NASA/US Coast Guard program involving development of a lightweight, helicopter-transportable firefighting module for a quick response in combating shipboard or harbor fires. Operable on land or water, the Amphib One is equipped with 3 water cannons. When all 3 are operating, unit pumps more than 3,000 gallons a minute. Newly developed model used by U.S. Coast Guard can pump 5,000 gallons per minute. It was designed for applications such as firefighting onboard ship fires, emergency dockside water pumping, dewatering ships in danger of sinking, flood control, and emergency water supply at remote locations.

Source record↗

Transcriptional regulation of IGF-I expression in skeletal muscle

The present study investigated the role of transcription in the regulation of insulin-like growth factor (IGF)-I expression in skeletal muscle. RT-PCR was used to determine endogenous expression of IGF-I pre-mRNA and mRNA in control (Con) and functionally overloaded (FO) rat plantaris. The transcriptional activities of five different-length IGF-I promoter fragments controlling transcription of a firefly luciferase (FLuc) reporter gene were tested in vitro by transfection of myoblasts or in vivo during FO by direct gene transfer into the plantaris. Increased endogenous IGF-I gene transcription during 7 days of plantaris FO was evidenced by an approximately 140-160% increase (P < 0.0001) in IGF-I pre-mRNA (a transcriptional marker). IGF-I mRNA expression also increased by approximately 90% (P < 0.0001), and it was correlated (R = 0.93; P < 0.0001) with the pre-mRNA increases. The three longest IGF-I exon 1 promoters induced reporter gene expression in proliferating C2C12 and L6E9 myoblasts. In differentiated L6E9 myotubes, promoter activity increased approximately two- to threefold over myoblasts. Overexpression of calcineurin and MyoD increased the activity of the -852/+192 promoter in C2C12 myotubes by approximately 5- and approximately 18-fold, respectively. However, FO did not induce these exogenous promoter fragments. Nevertheless, the present findings are consistent with the hypothesis that the IGF-I gene is transcriptionally regulated during muscle hypertrophy in vivo as evidenced by the induction of the endogenous IGF-I pre-mRNA during plantaris FO. The exon 1 promoter region of the IGF-I gene is sufficient to direct inducible expression in vitro; however, an in vivo response to FO may require elements outside the -852/+346 region of the exon 1 IGF-I promoter or features inherent to the endogenous IGF-I gene.

Non-NASA Center↗

ATP as a biomarker of viable microorganisms in clean-room facilities

A new firefly luciferase bioluminescence assay method that differentiates free extracellular ATP (dead cells, etc.) from intracellular ATP (viable microbes) was used to determine the viable microbial cleanliness of various clean-room facilities. For comparison, samples were taken from both clean-rooms, where the air was filtered to remove particles >0.5 microm, and ordinary rooms with unfiltered air. The intracellular ATP was determined after enzymatically degrading the sample's free ATP. Also for comparison, cultivable microbial populations were counted on nutrient-rich trypticase soy agar (TSA) plates. Both the cultivable and ATP-based determinations indicate that the microbial burden was lower in clean-room facilities than in ordinary rooms. However, there was no direct correlation between the two sets of measurements because the two assays measured very different populations. A large fraction of the samples yielded no colony formers on TSA, but were positive for intracellular ATP. Subsequently, genomic DNA was isolated directly from selected samples and 16S rDNA fragments were cloned and sequenced, identifying nearest neighbors, many of which are known to be noncultivable in the media employed. It was concluded that viable microbial contamination can be reliably monitored by measurement of intracellular ATP, and that this method may be considered superior to cultivable colony counts due to its speed and its ability to report the presence of viable but noncultivable organisms. When the detection of nonviable microbes is of interest, the ATP assay can be supplemented with DNA analysis.

NASA Discipline Environmental Health↗