Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Field Testing of Inverter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Field Demonstration of Inverter-based Voltage Management using Extremum Seeking Control

The influx of Distributed Energy Resources (DER) throughout the distribution system presents a challenge and an opportunity for maintaining power quality standards throughout the system. As such, DER Management systems have become a burgeoning field in both industry and academia. This work presents results from a field test of a model-free, distributed control approach, Extremum Seeking, applied to voltage management on a live feeder in Riverside, CA. The paper presents selected results to highlight the successes and challenges the control approach faced. The work shows that despite slow inverter response, extremum seeking control is able to drive voltage toward a target without knowledge of the system it is operating on.

14 SOLAR ENERGY↗

Building the next high voltage dc photogun polarized source for the ILC at JLab

During the ILC Global Design Effort (2007) two 200 kV high voltage photoguns based on an inverted insulator geometry were developed in 2010 and successfully tested at Jefferson Lab (JLab). One of the photoguns has been operated at 130 kV in the CEBAF accelerator for the JLab nuclear physics program. The inverted insulator replaces the electrode support structure, consequently significantly less metal prone to field emission is biased and surfaces contributing to the vacuum load are significantly reduced. Implementing a biased anode, and using a larger laser spot size has made this the state of the art polarized beam source with ~200 C charge lifetime from SSL GaAs photocathodes. However, operating at the design 200 kV voltage has been hindered by field emission at ~190 kV. To reliably operate without field emission requires lengthy conditioning applying 50-100 kV beyond the voltage needed for beam operations, without breakdown or damage to the insulator. Over the past decade, JLab has developed two photoguns with a larger version of the commercial inverted insulators used in the ILC design. One photogun operated at 300 kV for magnetized beam studies, and the concept has been implemented in the BNL polarized photogun. The second photogun has recently been installed in CEBAF to operate at 200 kV field emission free. Higher voltage photoguns help the ILC and CLIC achieve higher bunch charge (2013 TDR), and additionally provide margin for operating with shorter laser pulse length and/or smaller laser spot size (better emittance at higher peak current). Such photogun designs need to reach ~400 kV without breakdown or insulator damage to operate field emission free at > 300 kV. This also allows for direct injection into a SRF booster. JLab submitted a proposal to HEP for developing in partnership with industry an inverted geometry insulator to fit commercial 400 kV cables. This contribution describes JLab experience developing and testing high voltage photoguns, and what is needed to sufficiently condition for voltage levels higher than beam operational voltage.

Hernandez-Garcia, Carlos↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Previous papers and presentations have focused on the development of the test method using a benchtop prototype. This presentation covers the early results of C-AST aging of static and dynamic specimens.

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for C-AST. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed immediately once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure occurring in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy). Chemical composition analysis included: energy-dispersive X-ray spectroscopy, differential scanning calorimetry, and Fourier transform infrared spectroscopy.

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include offline modules, strings, and inverters; system shutdown; arc faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. In this study, unused field-vintage specimens are examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen current, voltage, and temperature. A significant increase in operating temperature (~100 degrees C from ~40 degrees C) and a different failure mode were observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow for failure analysis, including the extraction of the internal convolute springs for morphological examination (optical and electron microscopy).

balance of systems↗

Evaluating the Durability of Balance of Systems Components Using Combined-Accelerated Stress Testing: Preprint

The degradation of photovoltaic (PV) balance of systems (BoS) components is not well-studied, but the consequences include: offline-modules, -strings, -inverters; system shutdown; arc-faults; and fires. A utility provider experienced a ~30% failure rate in their power transfer chain, originally attributed to branch connectors. Field-failed specimen assemblies were therefore examined, consisting of cable connector, branch connector, and discrete fuse components. Unused field-vintage specimens are presently being examined using combined-accelerated stress testing (C-AST) to clarify the most influential environmental stressors as well as the effect of external mechanical perturbation. A benchtop prototype fixture was used to develop the perturbation capability for the C-AST chamber. The benchtop experiments were also used to develop the in-situ data acquisition of specimen: current, voltage, and temperature. A significant increase in operating temperature, ~100 deg C from ~40 deg C, and a different failure mode was observed promptly once periodic mechanical perturbation was applied. The current at failure was decreased from 35 A (with failure in the fuses) to 15 A (failure at the male/female metal pin connection). After initial examination using X-ray computed tomography, the external plastic was machined away from failed specimens to allow failure analysis, including the extraction of the internal convolute springs for morphological examination (optical- and electron-microscopy).

balance of systems↗

A 500 KV INVERTED GEOEMTRY FEEDTHROUGH FOR A HIGH VOLT-AGE DC ELECTRON GUN

The Continuous Electron Beam Accelerator Facility injector at Jefferson Lab (JLab) utilizes an inverted-geometry ceramic insulator photogun operating at 130 kV direct current to generate spin-polarized electron beams for high-energy nuclear physics experiments. A second photogun delivers 180 keV beam for commissioning a SRF booster in a testbed accelerator, and a larger version delivers 300 keV magnetized beam in a test stand beam line. This contribution reports on the development of an unprecedented inverted-insulator with cable connector for reliably applying 500 kV DC to a future polarized beam photogun, to be designed for operating at 350 kV without field emission. Such a photogun design could then be used for generating a polarized electron beam to drive a spin-polarized positron source as a demonstrator for high energy nuclear physics at JLab. There are no commercial cable connectors that fit the large inverted insulators required for that voltage range. Our proposed concept is based on a modified epoxy receptacle with intervening SF6 layer and a test electrode in a vacuum vessel.

Hernandez-Garcia, C.↗

Anomaly Identification of Synchronized Voltage Waveform for Situational Awareness of Low Inertia Systems

Inverter-based resources (IBRs) such as photovoltaics (PVs), wind turbines, and battery energy storage systems (BESSs) are widely deployed in low-carbon power systems. However, these resources typically do not provide the inertia needed for grid stability, resulting in a low-inertia power system. IBRs and lack of inertia have been known to cause anomalies such as waveform distortions and wideband oscillations in power systems due to the limited inertia level, leading to increased generation trips and load shedding. Here, to achieve effective anomaly identification, this paper proposes a synchro-waveform-based algorithm utilizing real-time synchronized voltage waveform measurements from waveform measurement units (WMUs). In the proposed method, different physical characteristics, as well as statistical features, are extracted from synchronized voltage waveform measurements to filter anomalies. Then, the anomaly identification approach based on the random forest is developed and deployed into the FNET/GridEye system considering trade-offs among accuracy, computational burden, and deployment cost. Moreover, four WMUs are specially designed and deployed on Kauai Island to receive instantaneous synchronized voltage waveform measurements. To verify the performance of the proposed algorithm, different experiments are carried out with collected field test data. The result demonstrates that the performance of the proposed synchro-waveform-based anomaly categorization algorithm can accurately identify anomalies 95.35% of the time, which has comparable performance among benchmarking algorithms.

Situational awareness↗

Resilient Inverter-Driven Black Start with Collective Parallel Grid-Forming Operation

As modern power systems are experiencing exceptional changes with increasing penetrations of inverter-based resources (IBRs), system restoration using IBRs has received attention. Using local grid-forming (GFM) assets near consumers, engineered to establish grid voltages in the absence of a stiff grid, i.e., bottom-up restoration, a distribution system could obtain high system resilience by not relying on the bulk power system restoration, which requires significant human intervention and procedure. This paper studies the technical feasibility of the novel approach with detailed electromagnetic transient (EMT) simulations. To thoroughly evaluate the potential of GFM inverters and the technical challenges in IBR-driven black start, a detailed three-phase inverter model is developed, including negative-sequence control for voltage balance and a phase-by- phase current limiter to sustain momentary overloading during the black start. To examine dynamic aspects of the black-start process, the EMT simulation also models transformer and motor dynamics to emulate their inrush and startup behaviors as well as network dynamics. In addition, active involvement of grid- following distributed energy resources is also studied to facilitate the black-start process. By allowing multiple GFM inverters to collectively black start without leader-follower coordination, we demonstrate that a system can achieve high resilience even with a fraction of assets lost. Two test cases of inverter-driven black start, using two and one GFM inverters, respectively, for a heavily unbalanced 2-MVA distribution feeder are demonstrated. Takeaways for further study and field deployment are provided.

grid-forming inverter↗

Resilient Inverter-Driven Black Start with Collective Parallel Grid-Forming Operation: Preprint

As the modern power systems are experiencing exceptional changes with increasing penetration of inverter-based resources (IBRs), system restoration using IBRs has received attention. Using local grid-forming (GFM) assets near consumers, engineered to establish grid voltages in the absence of a stiff grid, i.e., bottom-up restoration, a distribution system would obtain high system resilience, by not relying on the bulk power system restoration requiring significant human intervention and procedure to restore. This paper studies the technical feasibility of the novel approach with detailed electromagnetic transient (EMT) simulations. To thoroughly evaluate the potential of GFM inverters and technical challenges in IBR-driven black start, a detailed three-phase inverter model is developed, including negative-sequence control for voltage balance and a phase-by-phase current limiter to sustain momentary overloading during the black start. To examine dynamic aspects of the black start process, the EMT simulation also models transformer and motor dynamics to emulate their inrush and start-up behaviors as well as network dynamics. In addition, active involvement of grid-following distributed energy resources (DER) is also studied to facilitate the black start process. It is shown that, by allowing multiple GFM inverters to collectively black start without master-slave coordination, a system can achieve high resilience even with a fraction of assets lost. Two test cases of inverter-driven black start using two and one GFM inverters, respectively, for a heavily unbalanced 2-MVA distribution feeder are demonstrated. Takeaways for further study and field deployment are provided.

grid-forming inverter↗

Cybersecurity Certification Standard for Distributed Energy Resources

Cybersecurity Certification Standard for Inverter Based Resources led by UL, and contributed to by NREL, is a certification standard for devices and their cyber security practices. The standard, which is being developed and led by UL, contains certification and testing processes for the devices to be certified before they are deployed in the field. The importance of the standard is to ensure that all DER devices have all the five pillars of cybersecurity, in which the baseline cybersecurity posture of the DER industry will be elevated.

certification standard↗

Self‐Potential Tomography Preconditioned by Particle Swarm Optimization—Application to Monitoring Hyporheic Exchange in a Bedrock River

Abstract A self‐potential (SP) data‐inversion algorithm was developed and tested on an analytical model of electrical‐potential profile data attributed to single and multiple polarized electrical sources. The developed algorithm was then validated by an application to SP‐monitoring field data measured on the floodplain of East Fork Poplar Creek, Oak Ridge, Tennessee, to image electrical sources in areas conducive to preferential flow into the flood plain from the bedrock‐lined riverbed. The algorithm combined stochastic source‐localization by particle‐swarm‐optimization (PSO) of electrical sources characterized by simplified geometries with source tomography by regularized weighted least‐squares minimization of a quadratic objective function. Prior information was incorporated by preconditioning the tomography algorithm by PSO results. Variable percentages of random noise were added to analytical‐model data to evaluate the algorithm performance. Results indicated that true parameters of single‐source models were inverted and approximated with small residual error, whereas inversion of analytical‐model data representing multiple electrical sources accurately approximated the locations of the sources but miscalculated some parameters because of the non‐uniqueness of the inverse‐model solution. Source tomography applied to analytical model data during testing produced a spatially continuous parameter field that identified the locations of point‐scale synthetic dipole sources of electrical current flow with varying degrees of accuracy depending on the prior information incorporated into the tomography. When applied to SP‐monitoring field data, the algorithm imaged electrical sources within a known fault that intersects the bedrock riverbed and flood plain of East Fork Poplar Creek and depicted dynamic electrical conditions attributed to hyporheic exchange.

54 ENVIRONMENTAL SCIENCES↗

Shear reflectivity compensation in full-waveform inversion using least-squares reverse-time migration

SUMMARY The computational cost of elastic-waveform inversion is too high for inverting PP reflections, while using acoustic full-waveform inversion (FWI) is inaccurate because it does not depend on the shear modulus/velocity/impedance that affects elastic PP wavefield amplitudes. To solve this problem, we develop a waveform inversion method that uses acoustic least-squares reverse-time migration (LSRTM) to compensate the shear reflectivity for acoustic FWI. Our method is based on the quasi-elastic-wave equation developed by Chapman et al. (2014). The quasi-elastic-wave equation uses a linearized acoustic-wave equation with shear modulus μ as a virtual source to correct the acoustic PP wavefield amplitudes toward elastic ones. Our waveform inversion method inverts for elastic parameters by minimizing the L2 norm of the difference between recorded and predicted PP reflections modelled using the quasi-elastic-wave equation. Numerical tests on synthetic and field data show that our method can properly handle the amplitudes of elastic PP reflections and provides an accurate estimate of the P- and S-wave velocities/impedances and, in some cases, the density. The method does not need the computationally expensive numerical solution to the elastic-wave equation. It also gives a better estimate of elastic parameters than a pure LSRTM method for elastic PP reflections.

Feng, Zongcai↗

Hydraulic fracturing experiments at 1500 m depth in a deep mine: Highlights from the kISMET project

In support of the U.S. DOE SubTER Crosscut initiative, we established a field test facility in a deep mine and designed and carried out in situ hydraulic fracturing experiments relevant to enhanced geothermal systems (EGS) in crystalline rock to characterize the stress field, understand the effects of rock fabric on fracturing, and gain experience in monitoring using geophysical methods. The project also included pre- and post-fracturing simulation and analysis, and laboratory measurements and experiments. The kISMET (permeability (k) and Induced Seismicity Management for Energy Technologies) site was established in the West Access Drift of the Sanford Underground Research Facility (SURF) 4757 ft (1450 m) below ground (on the 4850 ft level (4850L)) in phyllite of the Precambrian Poorman Formation. We drilled and continuously cored five near-vertical boreholes in a line on 3 m (10 ft) spacing, deviating the two outermost boreholes slightly to create a five-spot pattern around the test borehole centered in the test volume 40 m below the drift invert (floor) at a total depth of ~1490 m (4890 ft). Laboratory measurements of core from the center test borehole showed P-wave velocity heterogeneity along each core indicating strong, fine-scale (~1 cm or smaller) changes in the mechanical properties of the rock. Field measurements of the stress field by hydraulic fracturing showed that the minimum horizontal stress at the kISMET site averages 21.7 MPa (3146 psi) trending approximately N-S (356 degrees azimuth) and plunging slightly NNW at 12°. The vertical and horizontal maximum stresses are similar in magnitude at 42-44 MPa (6090-6380 psi) for the depths of testing, which averaged approximately 1530 m (5030 ft). Hydraulic fractures were remarkably uniform suggesting core-scale and larger rock fabric did not play a role in controlling fracture orientation. Analytical solutions suggest that the fracture radius of the large fracture (stimulation test) was more than 6 m (20 ft), depending on the unknown amount of leak-off.

Oldenburg, C↗

Improving Subsurface Stress Characterization for Carbon Dioxide Storage Projects by Incorporating Machine Learning Techniques

The overall objective of this project is to develop a framework for reliable characterization and prediction of the state of stress in the overburden and underburden (including the basement) in CO 2 storage reservoirs using machine learning and integrated geomechanics and geophysical methods. Specifically, we propose to develop workflow encompassing of technologies and/or methods to predict stress and pressure changes due to CO 2 injection in an active tertiary recovery site and their impacts on subtle fault activation, fractures and occurrence of microseismic events and compare responses to field observations. In this project, we anticipate using dataset from the Farnsworth field Unit (FWU) which is operated by Purdure Petroleum. A novel elastic-waveform VSP inversion technique will be used to estimate high-resolution spatial and temporal changes of elastic moduli in CO 2 storage reservoirs, which will be combined with velocity-stress relationship derived from laboratory tests to obtain subsurface pressure and stress. Clustered microseismic data will be jointly inverted for improved focal mechanisms. Least-squares reverse-time migration of microseismic waveform data will be performed to directly image fracture/fault zones. Additionally, a deep neural network machine learning technique with convolutional and recurrent layers will be used for learning the spectro-temporal structures in microseismic waveforms. The results of this geotechnical data analysis will be integrated to develop a high-resolution 3D mechanical earth model extending from the overburden sealing formations to the underburden including the basement. Mechanical properties will be derived through integration of mechanical logs, tests, available results from chemo-mechanical laboratory tests, and elastic inversion of seismic data using a combination of Bayesian and stochastic methods as well as machine learning technique. Failure features (faults/fractures) will be represented and/or modeled based on seismic and core data analysis. A transient hydrodynamic-geomechanical model will be developed through coupling with the calibrated FWU reservoir simulation model. The full physics coupled model will be used to train a reduced order proxy model using machine learning algorithm for estimating stress which will then be used with appropriate constitutive relationships and forward seismological models to simulate pressure changes and induced microseismicity. An advanced optimization framework will be developed to perform a history match to minimize error between field observations and simulated. The history matched proxy model will be verified against the full-physics equivalent. The field observations that will be used in the coupled model calibration process include pressure/stress inverted from VSP, moment magnitude from microseismic analysis, real time downhole pressure measurements, production and injection data. Parameter sensitivity and uncertainty analysis will be performed to characterize the impact of model parameter uncertainty on stress estimates. The proposed project will have significant impact on future field implementation of the proposed technology. Because the project field site is an ongoing CO 2 EOR development, the value of the new technology will be demonstrated in an operational context and evaluated as a viable risk mitigation strategy. Cost/benefit will be evaluated together with the various commercial incentives for CO 2 sequestration available to oil and gas operators. The extensive available dataset and ongoing data acquisition under the SWP Phase III work plan provides flexibility for investigation of multiple approaches and reduces technical risk.

58 GEOSCIENCES↗

Real-Time Inertia Estimation Tool Implementation Based on Probing Signals

As renewable energy penetration increases and the traditional generators retire in power grids, system inertia decreases and exhibits significant daily fluctuations. Furthermore, fast frequency responses (FFRs) provided by the inverter-based resources (IBRs) begin to playa very critical role and bring new challenges to real-time system inertia monitoring due to the difficulties of quantifying its artificial inertia contribution. Thus, necessitating an accurate real-time inertia estimation tool will not only benefit the secure power grid operations, but also provide insights on assessing the artificial inertia contribution from the IBRs. This paper presents a probing-based real-time inertia estimation tool that has been validated through a power-hardware-in-the-Ioop (PHIL) test system using identical hardware battery energy storage system (BESS) and control in an actual power grid. Preliminary results indicate high estimation accuracy of the developed tool and pave the way for the field test and deployment.

inverter-based resources↗

Power-Hardware-in-the-Loop Experiments of a Microgrid with a Grid-Forming Battery Inverter

Microgrids continue to proliferate, and they are transitioning away from using conventional generating resources to increasingly relying on inverter-based resources (IBRs) as the voltage and frequency leaders. It is crucial to evaluate the capability of IBRs to provide microgrid stability and resilience. Hardware-in-the-loop (HIL) experiments were conducted to de-risk the field deployment of the San Diego Gas & Electric Company Borrego Springs Microgrid, where a battery inverter was upgraded with grid-forming (GFM) capability to serve as the island leader. This paper presents the HIL experimental results from an HIL test bed that uses a power-hardware-in-the-loop (PHIL) interface with a power inductor that was previously developed for PHIL simulations of microgrids where the inverters need to switch modes, i.e., between grid-following and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents more details on the interface and HIL simulation results of the planned islanding and load steps in islanded operation to show the effectiveness of the inverters in managing the voltage and frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power-Hardware-in-the-Loop Experiments of a Microgrid With a Grid-Forming Battery Inverter: Preprint

Microgrids continue to proliferate, and they are transitioning away from using conventional generating resources to increasingly relying on inverter-based resources (IBRs) as the voltage and frequency leaders. It is crucial to evaluate the capability of IBRs to provide microgrid stability and resilience. Hardware-in-the-loop (HIL) experiments were conducted to de-risk the field deployment of the San Diego Gas & Electric Company Borrego Springs Microgrid, where a battery inverter was upgraded with grid-forming (GFM) capability to serve as the island leader. This paper presents the HIL experimental results from an HIL test bed that uses a power-hardware-in-the-loop (PHIL) interface with a power inductor that was previously developed for PHIL simulations of microgrids where the inverters need to switch modes, i.e., between grid-following and GFM as the microgrid transitions between grid-connected and islanded operation. This paper presents more details on the interface and HIL simulation results of the planned islanding and load steps in islanded operation to show the effectiveness of the inverters in managing the voltage and frequency.

24 POWER TRANSMISSION AND DISTRIBUTION↗