Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fiber optic distributed temperature sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Local heat transfer measurement in a volumetrically heated TPMS lattice using distributed optical fiber thermal sensing

As additive manufacturing continues to reduce design constraints on heat exchange geometries, methods for high-fidelity local heat transfer measurements in nonconventional channel geometries are critical to their continued development. This study presents a novel method for measuring local heat transfer performance in volumetrically heated lattices using a distributed optical fiber temperature sensor. A diamond-type triply periodic minimal surface (TPMS) lattice, 3D-printed from a conductive polymer, was Joule heated while it was convectively cooled with air. Temperature measurements were taken at the solid–fluid interface across 14 internal locations using a single optical fiber over the Reynolds number range 800–2750. The TPMS lattice achieved up to 312% higher heat transfer coefficients compared to developing flow in a straight tube. A Nusselt number correlation was developed for the diamond TPMS, which showed good agreement with data collected for comparable geometries available in literature. In conclusion, this study presents a robust and new method for experimental measurement of the heat transfer coefficient in complex geometries and helps to understand and quantify the exceptional performance of TPMS heat transfer geometries.

TPMS↗

Imaging Fluid Flow in Geothermal Wells Using Distributed Thermal Perturbation Sensing

The objective of Task 2 is to develop a numerical method for the efficient and accurate analysis of distributed thermal perturbation sensing (DTPS) data for (1) imaging flow profiles and (2) in situ determination of thermal conductivities and heat fluxes. Numerical forward and inverse modeling is employed to: (1) Examine heat and fluid flow processes near a geothermal well under heating and cooling conditions; (2) Demonstrate ability to interpret DTPS thermal profiles with acceptable estimation uncertainty using inverse modeling of synthetic temperature data; and (3) Develop template model and analysis procedure for the inversion of temperature data collected during a thermal perturbation test using fiber-optic distributed temperature sensors. This status report summarizes initial model developments and analyses.

54 ENVIRONMENTAL SCIENCES↗

FINAL PROJECT REPORT: A Geophysical Characterization & Monitoring Strategy for Determining Hydrologic Processes in the Hyporheic Corridor at the Hanford 300-Area

The primary objective of this research was to advance the prediction of solute transport between the Uranium contaminated Hanford aquifer and the Columbia River at the Hanford 300 Area by improving understanding of how fluctuations in river stage, combined with subsurface heterogeneity, impart spatiotemporal complexity to solute exchange along the Columbia River corridor. Our work explored the use of continuous waterborne electrical imaging (CWEI), in conjunction with fiber-optic distributed temperature sensor (FO-DTS) and time-lapse resistivity monitoring, to improve the conceptual model for how groundwater/surface water exchange regulates uranium transport. We also investigated how resistivity and induced polarization can be used to generate spatially rich estimates of the variation in depth to the Hanford-Ringold (H-R) contact between the river and the 300 Area Integrated Field Research Challenge (IFRC) site. Inversion of the CWEI datasets (a data rich survey containing ~60,000 measurements) provided predictions of the distributions of electrical resistivity and polarizability, from which the spatial complexity of the primary hydrogeologic units along the river corridor was reconstructed. Variation in the depth to the interface between the overlying coarse-grained, high permeability Hanford Formation and the underlying finer-grained, less permeable Ringold Formation, an important contact that limits vertical migration of contaminants, has been resolved along ~3 km of the river corridor centered on the IFRC site in the Hanford 300 Area. Spatial variability in the thickness of the Hanford Formation captured in the CWEI datasets indicates that previous studies based on borehole projections and drive-point and multi-level sampling likely overestimate the contributing area for uranium exchange within the Columbia River at the Hanford 300 Area. Resistivity and induced polarization imaging between the river and the 300 Area IFRC further imaged spatial variability in the depth to the Hanford-Ringold inland over a critical region where borehole information is absent, identifying evidence for a continuous depression in the H-R contact between the IFRC and the river corridor. Strong natural contrasts in temperature and specific conductance of river water compared to groundwater at this site, along with periodic river stage fluctuations driven by dam operations, were exploited to yield new insights into the dynamics of groundwater-surface water interaction. Whereas FO-DTS datasets have provided meter-scale measurements of focused groundwater discharge at the riverbed along the corridor, continuous resistivity monitoring has non-invasively imaged spatiotemporal variation in the resistivity inland driven by river stage fluctuations. Time series and time-frequency analysis of FO-DTS and 3D resistivity datasets has provided insights into the role of forcing variables, primarily daily dam operations, in regulating the occurrence of focused exchange at the riverbed and its extension inland. High amplitudes in the DTS and 3D resistivity signals for long periods that dominate the stage time series identify regions along the corridor where stage-driven exchange is preferentially focused. Our work has demonstrated how time-series analysis of both time-lapse resistivity and DTS datasets, in conjunction with resistivity/IP imaging of lithology, can improve understanding of groundwater-surface water exchange along river corridors, offering unique opportunities to connect stage-driven groundwater discharge observed with DTS on the riverbed to stage-driven groundwater and solute fluctuations captured with resistivity inland.

58 GEOSCIENCES↗

A Geophysical Characterization & Monitoring Strategy for Determining Hydrologic Processes in the Hyporheic Corridor at the Hanford 300-Area

The primary objective of this research was to advance the prediction of solute transport between the Uranium contaminated Hanford aquifer and the Columbia River at the Hanford 300 Area by improving understanding of how fluctuations in river stage, combined with subsurface heterogeneity, impart spatiotemporal complexity to solute exchange along the Columbia River corridor. Our work explored the use of continuous waterborne electrical imaging (CWEI), in conjunction with fiber-optic distributed temperature sensor (FO-DTS) and time-lapse resistivity monitoring, to improve the conceptual model for how groundwater/surface water exchange regulates uranium transport. We also investigated how resistivity and induced polarization can be used to generate spatially rich estimates of the variation in depth to the Hanford-Ringold (H-R) contact between the river and the 300 Area Integrated Field Research Challenge (IFRC) site. Inversion of the CWEI datasets (a data rich survey containing ~60,000 measurements) provided predictions of the distributions of electrical resistivity and polarizability, from which the spatial complexity of the primary hydrogeologic units along the river corridor was reconstructed. Variation in the depth to the interface between the overlying coarse-grained, high permeability Hanford Formation and the underlying finer-grained, less permeable Ringold Formation, an important contact that limits vertical migration of contaminants, has been resolved along ~3 km of the river corridor centered on the IFRC site in the Hanford 300 Area. Spatial variability in the thickness of the Hanford Formation captured in the CWEI datasets indicates that previous studies based on borehole projections and drive-point and multi-level sampling likely overestimate the contributing area for uranium exchange within the Columbia River at the Hanford 300 Area. Resistivity and induced polarization imaging between the river and the 300 Area IFRC further imaged spatial variability in the depth to the Hanford-Ringold inland over a critical region where borehole information is absent, identifying evidence for a continuous depression in the H-R contact between the IFRC and the river corridor. Strong natural contrasts in temperature and specific conductance of river water compared to groundwater at this site, along with periodic river stage fluctuations driven by dam operations, were exploited to yield new insights into the dynamics of groundwater-surface water interaction. Whereas FO-DTS datasets have provided meter-scale measurements of focused groundwater discharge at the riverbed along the corridor, continuous resistivity monitoring has non-invasively imaged spatiotemporal variation in the resistivity inland driven by river stage fluctuations. Time series and time-frequency analysis of FO-DTS and 3D resistivity datasets has provided insights into the role of forcing variables, primarily daily dam operations, in regulating the occurrence of focused exchange at the riverbed and its extension inland. High amplitudes in the DTS and 3D resistivity signals for long periods that dominate the stage time series identify regions along the corridor where stage-driven exchange is preferentially focused. Our work has demonstrated how time-series analysis of both time-lapse resistivity and DTS datasets, in conjunction with resistivity/IP imaging of lithology, can improve understanding of groundwater-surface water exchange along river corridors, offering unique opportunities to connect stage-driven groundwater discharge observed with DTS on the riverbed to stage-driven groundwater and solute fluctuations captured with resistivity inland.

54 ENVIRONMENTAL SCIENCES↗

Characterization of Embedded Sensors in Stainless Steel Test Articles and Design/Planning for MAGNET Testing

The nuclear industry is pursuing microreactors that can be factory assembled and deployed to remote regions for reliable power generation. One class of microreactors uses a monolithic metal core block coupled to heat pipes for heat rejection, which results in significant thermal stresses in the monolithic structures. This work describes the initial characterization and test plan for evaluating stainless steel test articles fabricated with embedded sensors for measuring heat pipe performance limits, as well as spatially distributed temperatures and strains during electrically heated thermal testing. The electrically heated testing will be performed in the non-nuclear Microreactor Agile Non-Nuclear Testbed and Single Primary Heat Extraction and Removal Emulator facilities located at Idaho National Laboratory. The goals of these tests are to (1) accurately monitor temperature and strain distributions that result from differential thermal expansion in the test articles and (2) quantify heat rejection limits of heat pipes as a function of operating temperature and working fluid during steady-state and transient operations. More generally, the ability to monitor component and system health during microreactor operation is attractive for providing a high sensor density to inform a limited number of microreactor operators to ultimately reduce operation and maintenance costs and move toward semi-autonomous operation. This report discusses the characterization of embedded thermocouples and fiber optic sensors in relevant test articles, including cylindrical pipes and hexagonal monolithic test articles for heat pipe-based reactors. The sensors were embedded by placing them in machined channels and then building up additional material by using ultrasonic additive manufacturing (UAM). UAM is a solid-state welding process that uses downward pressure and a lateral scrubbing motion to bond thin metal foils to a base material layer by layer. The ultrasonic welding process relies on the plastic deformation of the metal—as opposed to typical melting and solidification—to break oxide scales and bond the metal layers. The characterization of these embedded sensors included evaluating fiber optic signal attenuation, observing residual strain in the fibers, investigating microstructural and mechanical aspects, and demonstrating the sensors under various thermal loads and acoustic vibrations. Post-embedding characterization showed a fine grain structure (<1 μm) near the interfaces of the bonded foils as a result of severe deformation from the welding process. A large increase in hardness was observed at the foil interfaces and the fiber/matrix interface compared with the bulk matrix. Even when compared with the SS304 interfaces, the higher hardness observed around the embedded fiber suggests a higher degree of deformation due to the soft metal coating around the silica fiber core. The distributed fiber-optic temperature sensors and embedded thermocouples reliably measured temperature distributions during steady-state and transient thermal testing. The embedded fiber-optic sensors reliably measured strain during both transient and steady-state testing and properly identified resonant frequencies during acoustic testing.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance of Embedded Sensors in 3D Printed SiC

This report summarizes recent advances in embedding sensors in 3D printed silicon carbide (SiC) ceramic components under the Transformational Challenge Reactor (TCR) program. The additive manufacturing technologies developed under this program will enable fabrication of complex structures with embedded fuels and sensors. The sensors will be capable of characterizing fuel performance using spatially distributed measurements at the most strategic locations that would be otherwise inaccessible using conventional manufacturing techniques. While previous programmatic updates describe initial concepts for embedding sensors, materials selection, and initial characterization of the embedded sensors, the technology requires further demonstration, and quality-significant procedures must be established before the embedding technology is ready for adoption by industry. To this end, this report describes the most effective techniques that have been used to embed functional sensors in 3D printed components using a combination of binder-jet additive manufacturing and chemical vapor infiltration (CVI). A detailed procedure describes each step in the process and is available upon request. Molybdenum (Mo)-sheathed thermocouples have been successfully embedded in complex SiC components, and temperatures were monitored in situ during the embedding process. Post-embedding measurements showed no significant hysteresis, and characterization of the interface revealed qualitatively strong bonding around the entire perimeter of the sensor sheath. Distributed fiber-optic temperature sensors were able to briefly measure temperature profiles during CVI, but they ultimately failed prior to completion of the CVI run. The failure appears to be related to the fiber coating at temperatures close to 1,000°C. Future work will focus on irradiation testing of embedded thermocouples and other sheathed electrical sensors, as well as the identification of fiber-optic sensor coatings that can survive CVI.

42 ENGINEERING↗

Real-Time Monitoring of Temperature Rises of Energized Transformer Cores With Distributed Optical Fiber Sensors

Real-time temperature mapping that solves local overheating problems is important for obtaining an optimized thermal design for high-efficiency power transformers. Internal temperature monitoring of operating power transformers can also be leveraged for asset monitoring applications targeting at fault detection enabling condition-based maintenance. Transformers present a variety of challenging sensing environments such as high levels of electromagnetic interference and limited space for conventional sensors to operate. Immersion of power transformers in insulation oils for thermal management during operation and the presence of relatively large and time-varying electrical and occasional magnetic fields make sensing technologies requiring electrical wires or active power at sensing locations highly undesirable. In this work, we investigate thermal response of a standard telecom fiber instrumented on compact transformer cores by using an optical frequency-domain reflectometry scheme. As a result, correlation between conventional temperature sensing methods and fiber-optic sensing results as well as tradeoffs between spatial resolution and temperature measurement accuracy is discussed and spatially resolved real-time monitoring of temperatures in energized transformers is experimentally demonstrated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental study on the startup of the annular wick type heat pipe using fiber optical temperature measurement technique

This study used optical fiber-distributed temperature sensors to measure the internal and external temperature distributions of a water-cooled heat pipe. The sensor technology used in this study is fiber optical distributed temperature sensing, a distributed sensing technique based on the naturally occurring Rayleigh backscatter in optical fibers. This measurement technique provides maximum spatial resolution for static and semi-static applications. Using this sensor, the temperature distribution of the heat pipe's internal, external, vapor core, and the wick was measured with a spatial resolution of 0.65 mm, a sampling frequency of 40 Hz, and a temperature resolution of 0.1 °C. Through the measured temperature distribution database, the starting phenomenon, the effective length trend, and the limitation onset were observed. From the results, it is found that a high-temperature peak appears at the evaporator if a high initial power (75 W) is imposed on the heat pipe, even after the heat pipe approaches the normal operating status. The peak is not observed in a slower startup (30 W initial power then slowly increased to 75 W). It is also found that the temperature distributions and effective condenser length of the heat pipe highly depend on the cooling conditions. There are variations in the temperature according to the radial direction of the horizontal heat pipe due to gravity. In conclusion, lead and lag of the temperature evolution were observed at the onset of the operating limitations.

42 ENGINEERING↗

Demonstration of Embedded Sensors in Ceramic Structures

The Transformational Challenge Reactor (TCR) program seeks to demonstrate an advanced 3D printed nuclear reactor core. A binder jet additive manufacturing process is used to fabricate the complex SiC ceramic components of the TCR core. After printing, the components are densified via chemical vapor infiltration (CVI). This process allows complex cavities to be created in which sensors can be placed at strategic locations. Inserting the sensors during the CVI process allows the sensors to be embedded within the component as it is infiltrated. The primary challenge for embedding the sensors is identifying the sensors and sensor sheath materials that can survive the temperatures (>1,000°C) and chemical exposure to H 2 and HCl during CVI. The embedded sensors that are being investigated for use during TCR operation include thermocouples, self-powered neutron detectors, and spatially distributed fiber-optic temperature sensors. This report describes the CVI materials compatibility tests and initial trials for embedding functional sensors. Mo is identified as the most suitable sensor sheath material based on its availability in small diameter tubing, relatively low neutron absorption cross section, and compatibility with H 2 , HCl, and the surrounding SiC matrix at the process temperatures. Amorphous SiO2 fiber-optic samples with Au and Cu metal coatings were successfully embedded in SiC along with bare fibers, although the metal coatings showed some evidence of localized melting during CVI. Initial experiments attempting to embed functional sensors showed that the sensors can be embedded in 3D printed SiC parts, but there are still challenges that must be overcome to ensure that the sensors and sensor sheaths do not fail during CVI. In particular, Nb-sheathed Mo-Nb thermocouples failed at temperatures far lower than expected despite thermodynamic calculations and materials compatibility tests that show the Nb sheath to be compatible with the CVI environment. One potential explanation for the large expansion of the Nb sheath could be related to hydride formation in the lower temperature region of the sheath. Future work will focus on Mo-sheathed thermocouples instead of Nb. The fiberoptic sensors tested during the instrumented experiment broke due to the lack of mechanical protection after their polymer-based coatings were vaporized. Future instrumented experiments will use metal-coated optical fibers for strain sensing to provide additional mechanical protection. However, custom coatings with higher melting points than commercially available Au and Cu might be required. Regardless, fiber-optic sensors are still candidates for spatially distributed temperature measurements since they can be inserted into an embedded metal sheath after CVI.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Comparison of fiber-optic distributed temperature sensing and high-sensitivity sensor spatial surveying of stream temperature

Measuring surface water temperature spatial variability is needed to estimate the interaction between surface water and groundwater, evaluate fish habitat and thermal inertia, and to estimate streamflow frequency and duration. Fiber optic distributed temperature sensing (FO-DTS) has been used in rivers and lakes, providing high-resolution and sensitive temperature monitoring over large temporal and spatial scales. However, in streams with cobbly or bedrock-lined streambeds and variable bathymetry, use of FO-DTS to measure temperature close to the surface water and groundwater interface can be challenging if even feasible. FO-DTS can also be costly, involve difficult installations, and require an advanced understanding of the technology, calibration, and data processing. In this study, we compared FO-DTS stream temperature survey results to an alternative temperature survey method employing a towed transect of high-resolution temperature loggers spaced at 1-m and transported in the stream along the study reach, to measure the spatial distribution of stream-water temperature in East Fork Poplar Creek near Oak Ridge, Tennessee, USA. We assessed the applicability and limitations of the two methods, and quantitatively compared in-situ temperature survey results measured simultaneously with each method. Regression results showed strong temporal and spatial correlation between the two methods. Differences were only elevated near the stream banks in areas that were coincident with correlation slope deviations from unity, which was attributed to shallower water and lower data density. Kriging standard errors were also low at channel center with minor increases near the stream banks. Furthermore, the results suggested that the array of the individual temperature sensors can provide a practical alternative to FO-DTS for thermal characterization of surface water, providing slightly lower spatial and temporal resolution, but with higher accuracy of temperature measurement, with greater simplicity, and with a broader range of conditions where it may be applied.

54 ENVIRONMENTAL SCIENCES↗

Fiber Optic Distributed Sensors for High-resolution Temperature Field Mapping

The reliability of computational fluid dynamics (CFD) codes is checked by comparing simulations with experimental data. A typical data set consists chiefly of velocity and temperature readings, both ideally having high spatial and temporal resolution to facilitate rigorous code validation. While high resolution velocity data is readily obtained through optical measurement techniques such as particle image velocimetry, it has proven difficult to obtain temperature data with similar resolution. Traditional sensors such as thermocouples cannot fill this role, but the recent development of distributed sensing based on Rayleigh scattering and swept-wave interferometry offers resolution suitable for CFD code validation work. Thousands of temperature measurements can be generated along a single thin optical fiber at hundreds of Hertz. Sensors function over large temperature ranges and within opaque fluids where optical techniques are unsuitable. But this type of sensor is sensitive to strain and humidity as well as temperature and so accuracy is affected by handling, vibration, and shifts in relative humidity. Such behavior is quite unlike traditional sensors and so unconventional installation and operating procedures are necessary to ensure accurate measurements. This paper demonstrates implementation of a Rayleigh scattering-type distributed temperature sensor in a thermal mixing experiment involving two air jets at 25 and 45 °C. We present criteria to guide selection of optical fiber for the sensor and describe installation setup for a jet mixing experiment. We illustrate sensor baselining, which links readings to an absolute temperature standard, and discuss practical issues such as errors due to flow-induced vibration. This material can aid those interested in temperature measurements having high data density and bandwidth for fluid dynamics experiments and similar applications. We highlight pitfalls specific to these sensors for consideration in experiment design and operation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Wireless Instrumented RB Experiment Preliminary Design and Analysis

The ability to deploy new nuclear fuels for current or future reactor concepts requires carefully designed experiments to generate data to support fuel qualification. Ideally these experiments would include state of-the-art sensing to maximize the amount of in situ data that can be collected during operation. Furthermore, advanced reactor systems can take advantage of integrated in-core sensing technologies to maximize fuel utilization, reduce unnecessary conservativism in design margins, and improve operator’s understanding of limiting peaking factors. Before any novel sensing technologies can be readily adopted for nuclear applications, they must first demonstrate acceptable performance in test reactors. This report summarizes the preliminary design and analysis of the most highly instrumented irradiation experiment ever performed in the removable beryllium (RB) positions of the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). The Wireless Instrumented RB Experiment 2021 (WIRE-21) will test a wide range of sensors including wireless sensors being developed by Westinghouse Electric Company (WEC) that could provide in situ measurements of peak fuel temperatures and fuel rod pressurization due to fission gas release. The ability to wirelessly transmit a signal through the fuel rod’s cladding is critical to improving fuel monitoring capabilities without requiring signal penetrations through the cladding pressure boundary, which would significantly impact fuel fabrication, handling, and operation. Other sensors that will be tested in WIRE-21 include an array of thermocouples, self-powered neutron detectors (SPNDs), and spatially distributed fiber-optic temperature sensors. More generally, WIRE-21 will establish a flexible irradiation vehicle design to allow accelerated, economical testing of advanced sensor technologies while leveraging the extremely high neutron flux that is available in HFIR. This report summarizes the mechanical design for WIRE-21, the experimental test matrix, initial neutronic and thermal design analyses, and the active monitoring and control system enhancements necessary to support testing of advanced sensor technologies. The containment for WIRE-21 is similar to previous RB irradiation vehicles but includes a few modifications, most notably the use of integrated compression seals to pass a larger number of sensor leads through the experiment’s pressure boundary. In addition to the sensor leads, inert gas lines are passed into the experiment to enable active temperature control and the ability to pneumatically actuate a bellows-driven pressure sensor. WIRE-21 is targeting temperatures (300–350°C) and neutron fluence levels (~10 22 n/cm 2 ) relevant to light water reactors (LWRs), but the flexible design of the experiment vehicle allows much higher operating temperatures (>1,100°C). Neutronic calculations determine the neutron flux conditions as well as the nuclear heating within the experiments. These results are used as inputs to detailed thermal finite element calculations, which are required to evaluate the complex, three-dimensional heat transfer that occurs within WEC’s wireless sensor enclosures. Initial results show that the temperatures of the sensors’ enclosures and the metal bellows can be operated near the temperature range of LWR coolants and cladding while simultaneously increasing the temperature of a surrogate fuel material to values in the range of 800–1200°C to simulate centerline fuel temperatures during LWR operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Distributed Temperature Sensing within a 19-pin Wire-Wrapped Fuel Bundle Model

It has always been difficult to measure local temperature and flow velocity within fuel bundle geometries because of their complex and compact layouts. High-resolution mapping of the flow field is especially challenging. High-resolution data is typically obtained using optical instruments but optical access to the interior regions of a bundle is severely limited. Velocity fields within fuel bundle models have been mapped with particle image velocimetry (PIV), an optical technique that employs lasers and cameras. Optical access to the bundle interior is obtained using transparent materials and matching the refractive index of the physical structures with that of the fluid. Testing is necessarily isothermal because refractive indices vary with temperature. However, the ultimate aim of such studies is understanding fluid dynamics and heat transfer within real reactors and so flow field mapping under nonisothermal conditions is of particular interest. Temperature fields can be mapped at high-resolution using laser-induced fluorescence (LIF). However, as an optical technique it is unsuitable for nonisothermal liquid flows. This is due to the same sort of optical distortion that restricts PIV. It is also unsuitable for opaque fluids and setups with restricted optical access. Fiber optic distributed temperature sensing (DTS) offers a high-resolution alternative that does not rely upon imaging. A single sensor can map temperature fields at resolutions far exceeding that achievable with conventional sensors such as thermocouples. Though fiber optic sensors cannot match the spatial resolution and bandwidth of LIF, they are suitable for nonisothermal and opaque flows. And though fibers are physical probes that perturb the flow, they can be strung across complex geometries to provide data in regions lacking the optical access necessary for techniques like LIF. Distributed temperature sensing has the potential to provide fuel bundle temperature data of a type that cannot be obtained with optical methods or conventional sensors. This paper reports on preliminary results of efforts to use fiber optic distributed temperature sensors in a fuel bundle model. We are conducting a feasibility study exploring implementation issues such as strain control in the mounting configuration and signal noise associated with flow-induced vibration. We describe here the setup and present preliminary data from our first phase testing with stagnant flow. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calibration of Distributed Temperature Sensors Using Commercially Available SMF-28 Optical Fiber From 22 °C to 1000 °C

Optical frequency domain reflectometry (OFDR) is a family of optical techniques which can be used to produce distributed temperature measurements from the spectral shift of an interference pattern based on the Rayleigh backscatter signature of an optical fiber. Adaptive signal processing techniques have recently been used with OFDR to record meaningful spectral shift data from commercially available SMF-28 optical fibers heated beyond 950 °C. Furthermore, a correlation between the measured spectral shift and temperature has not yet been developed at these high temperatures. To extend the measurable temperature range of OFDR in SMF-28, this work describes the development of such a correlation from room temperature (22 °C) to 1000 °C. The relationship between spectral shift and temperature change over this range was found to be best characterized by the fourth-order polynomial ΔT=(-4.241 * 10 -11 )S 4 + (-2.017 * 10 -7 )S 3 + (-3.677 * 10 -4 )S 2 + (-0.8057)S, where ΔT represents the temperature difference compared to the reference temperature, and S represents the spectral shift measured by the fibers. The calibration developed in this work assumes that the fiber has been fully annealed by heating the fiber to 1000 °C for a few hours. This paper is the first to demonstrate the calibration and use of SMF-28 distributed optical fiber sensors up to 1000 °C, enabled using adaptive OFDR-based signal processing.

47 OTHER INSTRUMENTATION↗

Abstract for CRADA between NETL and Westinghouse Electric Company

The National Energy Technology Laboratory (NETL) and Westinghouse will collaborate in testing a new NETL invention known as the single-crystal optical fiber Raman Distributed Temperature Sensor (DTS). Westinghouse will use the NETL Raman DTS to test performance of their new e-Vinci heat-pipe reactor systems.

47 OTHER INSTRUMENTATION↗

Distributed Temperature Profiles of Silicon Carbide Catalyst Bed in a Microwave Reactor using Fiber-optic Sensor

Microwave heating is of great interest for reducing greenhouse gas emissions of catalytic chemical conversion processes because it can heat up the reactants rapidly and efficiently and accelerate reaction rates. In microwave-assisted catalytic thermochemical conversion processes, accurate internal temperature measurement would help facilitate effective process control. Metallic thermocouples interfere and spark in the microwave heating environment, so they are not an option. Infrared pyrometers typically provide a single temperature value by averaging over a finite surface area of the catalyst bed. In this work, we use fiber-optic sensors passing through the catalyst bed to provide more accurate temperatures along the height of the catalyst bed. The fiber optic sensors are immune to the electromagnetic microwave radiation and provide temperature profiles along their length. Here, custom fiber-optic sensors were coupled to the optical distributed temperature sensing devices to measure the temperature profiles along the height of the catalyst bed at high temperatures with ~1 mm spatial resolution. The sensing devices use optical frequency domain reflectometry (OFDR) technique for distributed temperature measurement. This work shows the temperature profiles along the height of the silicon carbide powder catalyst bed in the variable and fixed frequency microwave reactors.

Thapa, Juddha↗

One-Step Ahead Prediction of Thermal Mixing Tee Sensors with Long Short Term Memory (LSTM) Neural Networks

High-temperature advanced reactors under development, such as sodium fast reactors (SFR) and molten salt cooled reactors (MSCR), are expected to offer lower levelized cost of energy (LCOE) compared to existing light water reactor (LWR’s). In the existing light water reactors (LWR’s), operation and maintenance (O&M) expenses constitute the largest fraction of the total operating cost. Some of the O&M costs are related maintenance of sensors which can fail due to exposure to harsh environment in a reactor. The O&M costs of Advanced Reactor (AR)’s are expected to constitute a significant fraction of the total cost as well, because of high temperature and radiation level in AR are likely to cause material fatigue and premature failure of sensors and components. The O&M costs in AR’s could be reduced through integration of advanced informatics of performance-related sensors into a digital twin designed for reactor monitoring. For example, machine learning (ML) could be employed for real-time validation and correction of performance-related sensors, and reducing the number of performance-related physical sensor units through virtual sensing. As part of the effort, we investigate real-time validation of thermal hydraulic sensors through one-step ahead forecasting of sensor values using long short-term memory (LSTM) recurrent neural networks (RNN). The sensors are installed in a flow loop containing a thermal mixing tee, which is a common experimental model to study thermal fatigue in a thermal hydraulic loop. In addition, nonlinear transients generated in a thermal mixing tee constitute a good challenge data set for training and validation of ML algorithms. Sensors in this study include thermocouples, flow meters, and optical fibers for distributed temperature sensing. In one experiment, measurement data sets were obtained for a loop was filled with water, and in another experiment, measurements were performed on a loop filled with liquid metal Galinstan. We have also conducted preliminary investigation of one-step ahead prediction of fiber optics-based distributed temperature sensing with LSTM networks. In predicting fiber-based temperature measurements, we treated each gauge pitch of the fiber as an independent sensor. Accuracy of one-step ahead forecasting was estimated by calculating root mean square error (RMSE) for the test segment of time series of each sensor. RMSE’s for temperature sensors in water loop were, for the most part, lower than for the same sensors in Galinstan loop. The RMSE’s for flow meters were similar for both loops. The RMSE’s for distributed temperature measured with the fiber optic sensor were similar to those of the point sensors. Results of this study demonstrated the capability of LSTM one-step ahead forecasting with RMSE comparable to uncertainty in sensor measurements.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗