Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fe-K”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

SUZAKU VIEW OF X-RAY SPECTRAL VARIABILITY OF THE RADIO GALAXY CENTAURUS A: PARTIAL COVERING ABSORBER, REFLECTOR, AND POSSIBLE JET COMPONENT

We observed a nearby radio galaxy, Centaurus A (Cen A), three times with Suzaku in 2009 and measured the wide-band X-ray spectral variability more accurately than previous measurements. The Cen A was in an active phase in 2009, and the flux became higher by a factor of 1.5-2.0 and the spectrum became harder than that in 2005. The Fe-K line intensity increased by 20%-30% from 2005 to 2009. The correlation of the count rate between the XIS 3-8 keV and PIN 15-40 keV band showed a complex behavior with a deviation from a linear relation. The wide-band X-ray continuum in 2-200 keV can be fitted with an absorbed power-law model plus a reflection component, or a power law with a partial covering Compton-thick absorption. The difference spectra between high and low flux periods in each observation were reproduced by a power law with a partial covering Compton-thick absorption. Such a Compton-thick partial covering absorber was observed for the first time in Cen A. The power-law photon index of the difference spectra in 2009 is almost the same as that of the time-averaged spectra in 2005, but steeper by {approx}0.2 than that of the time-averaged spectra in 2009. This suggests an additional hard power-law component with a photon index of <1.6 in 2009. This hard component could be a lower part of the inverse-Compton-scattered component from the jet, whose gamma-ray emission has recently been detected with the Fermi Large Area Telescope.

79 ASTRONOMY AND ASTROPHYSICS↗

A SUZAKU DISCOVERY OF A SLOWLY VARYING HARD X-RAY CONTINUUM FROM THE TYPE I SEYFERT GALAXY NGC 3516

The bright type I Seyfert galaxy NGC 3516 was observed by Suzaku twice, in 2005 October 12-15 and 2009 October 28-November 2, for a gross time coverage of 242 and 544 ks and a net exposure of 134 and 255 ks, respectively. The 2-10 keV luminosity was 2.8 Multiplication-Sign 10{sup 41} erg s{sup -1} in 2005 and 1.6 Multiplication-Sign 10{sup 41} erg s{sup -1} in 2009. The 1.4-1.7 keV and 1.7-10 keV count rates both exhibited peak-to-peak variations of a factor of {approx}2 in 2005 and {approx}4 in 2009. In both observations, the 15-45 keV count rate was less variable. The 2-10 keV spectrum in 2005 was significantly more convex than that in 2009. Through a count-count plot technique, the 2-45 keV signals in both sets of data were successfully decomposed in a model-independent way into two distinct broadband components. One is a variable emission with a featureless spectral shape, and the other is a non-varying hard component accompanied by a prominent Fe-K emission line at 6.33 keV (6.40 keV in the rest frame). The former was successfully fitted by an absorbed power-law model, while the latter requires a new hard continuum in addition to a reflection component from distant materials. The spectral and variability differences between the two observations are mainly attributed to long-term changes of this new hard continuum, which was stable on timescales of several hundreds of kiloseconds.

79 ASTRONOMY AND ASTROPHYSICS↗

A FOCUSED, HARD X-RAY LOOK AT ARP 299 WITH NuSTAR

We report on simultaneous observations of the local starburst system Arp 299 with NuSTAR and Chandra, which provides the first resolved images of this galaxy up to energies of ∼45 keV. Fitting the 3-40 keV spectrum reveals a column density of N {sub H} ∼ 4 × 10{sup 24} cm{sup –2}, characteristic of a Compton-thick active galactic nucleus (AGN), and a 10-30 keV luminosity of 1.2 × 10{sup 43} erg s{sup –1}. The hard X-rays detected by NuSTAR above 10 keV are centered on the western nucleus, Arp 299-B, which previous X-ray observations have shown to be the primary source of neutral Fe-K emission. Other X-ray sources, including Arp 299-A, the eastern nucleus also thought to harbor an AGN, as well as X-ray binaries, contribute ≲ 10% to the 10-20 keV emission from the Arp 299 system. The lack of significant emission above 10 keV other than that attributed to Arp 299-B suggests that: (1) any AGN in Arp 299-A must be heavily obscured (N {sub H} > 10{sup 24} cm{sup –2}) or have a much lower luminosity than Arp 299-B and (2) the extranuclear X-ray binaries have spectra that cut-off above ∼10 keV. Such soft spectra are characteristic of ultraluminous X-ray sources observed to date by NuSTAR.

79 ASTRONOMY AND ASTROPHYSICS↗

ON THE X-RAY BALDWIN EFFECT IN ACTIVE GALACTIC NUCLEI OBSERVED BY THE CHANDRA HIGH-ENERGY GRATING

Using Chandra high-energy grating (HEG) observations of 32 active galactic nuclei (AGNs), we present a systematic study of the X-ray Baldwin effect (XBE; i.e., the anti-correlation between the narrow Fe K{alpha} line equivalent width (EW) and X-ray continuum luminosity for AGN samples) with the highest spectral resolution currently available. We have previously reported an anti-correlation with EW{proportional_to}L{sup -0.22}{sub 2-10keV} in an HEG sample, and the correlation is much weaker after averaging multiple observations of individual AGNs (EW{proportional_to}L{sup -0.13}{sub 2-10keV}). This indicates that rapid variation in the X-ray continuum plays an important role in producing the XBE, and such an effect should also be visible in individual AGNs. In this Letter, by normalizing the line EWs and continuum luminosities to the time-averaged values for each AGN in our sample with multiple HEG observations, we find a strong anti-correlation between EW and L{sub X} (EW/(EW){proportional_to}(L/(L)){sup -0.82{+-}0.10}), consistent with the XBE expected in an individual AGN if the narrow line flux remains constant while the continuum varies. This is first observational evidence that the Fe K{alpha} line flux in a large sample of AGNs lacks a corresponding response to the continuum variation, supporting the fact that the narrow Fe-K line emission originates from a region far from the nucleus. We then performed Monte Carlo simulations to address whether the global XBE can be produced by X-ray continuum variation solely, and found that such an interpretation of the XBE cannot be ruled out statistically. One should thus be very cautious before drawing any scientific conclusion based on an observed XBE.

79 ASTRONOMY AND ASTROPHYSICS↗

A uniform metallicity in the outskirts of massive, nearby galaxy clusters

Suzaku measurements of a homogeneous metal distribution of Z ~ 0:3 Solar in the outskirts of the nearby Perseus cluster suggest that chemical elements were deposited and mixed into the intergalactic medium before clusters formed, likely over 10 billion years ago. A key prediction of this early enrichment scenario is that the intracluster medium in all massive clusters should be uniformly enriched to a similar level. Here, we confirm this prediction by determining the iron abundances in the outskirts (r > 0:25r200) of a sample of ten other nearby galaxy clusters observed with Suzaku for which robust measurements based on the Fe-K lines can be made. Across our sample the iron abundances are consistent with a constant value, ZFe = 0:316 ± 0:012 Solar (Χ 2 = 28:85 for 25 degrees of freedom). This is remarkably similar to the measurements for the Perseus cluster of ZFe = 0:314±0:012 Solar, using the Solar abundance scale of Asplund et al. (2009).

79 ASTRONOMY AND ASTROPHYSICS↗

The Astro-E High Resolution X-Ray Spectrometer

The Astro-E High Resolution X-ray Spectrometer (XRS) was developed jointly by the NASA/Goddard Space Flight Center and the Institute of Space and Astronautical Science in Japan. The instrument is based on a new approach to spectroscopy, the X-ray microcalorimeter. This device senses the energies of individual X-ray photons as heat with extreme precision. A 32 channel array of microcalorimeters is being employed, each with an energy resolution of about 12 eV at 6 keV (the Fe-K region). This will provide spectral resolving power 10 times higher than any other non-dispersive X-ray spectrometer. The instrument incorporates a three stage cooling system capable of operating the array at 60 mK for about two years in orbit. The array sits at the focus of a grazing incidence conical mirror. The quantum efficiency of the microcalorimeters and the reflectivity of the X-ray mirror system combine to give high throughput over the 0.3-12 keV energy band. This new capability will enable the study of a wide range of high-energy astrophysical sources with unprecedented spectral sensitivity. This paper presents the basic design requirements and implementation of the XRS, and also describes the instrument parameters and performance.

Kelley, Richard L.↗

Studying the Iron Line Complex in the Bright Seyfert Galaxy NGC 5506

This grant was to support the reduction and analysis of our approved XMM observation of the nearby Seyfert 2 galaxy NGC 5506. The observation has been carried out simultaneously with a BeppoSAX observation of the same source. The proposal was aimed to study in detail the Compton reflection component and the complex Iron K line of this source, combining the still unique capability of BeppoSAX in hard X-rays (to strongly constrain the reflection component, and then the intrinsic nuclear continuum), and the sensitivity of XMM at the energy of the Iron Line complex. NGC 5506 is one of the brightest AGN in hard X-rays and has been intensively studied in the past. GINGA detected the complex iron line as well as the reflection component. Both ASCA (spectroscopically) and Rossi-XTE (through variability analysis) suggested that the FeK line is complex, possibly made up of several distinct components. The centroid of the FeK complex in a subsequent BeppoSAX observation was bluer than the 6.4 keV energy of the relatively low-ionization iron Kalpha transition. NGC 5506 has been observed simultaneously by NewtonXMM and BeppoSAX on February 2-3 2001. we have reduced and analyzed both the NewtonXMM and the BeppoSAX data, and have written and published a paper on our results (appeared in Volume 377 (page 31) of A&A-Letters). Our main results can be summarized as follows: (a) we confirm that the FeK line is complex, and for the first time disentangle its components: we find that at least two components made up the FeK complex, one neutral and narrow, at 6.4 keV (rest energy), and another one either broader and highly ionized, at about 6.7 keV (rest frame), or, in turn, made up of two narrow and unresolved components from the He-like and the H-like ions of Fe; (b) the two possible solution for the high-ionization Fe-K component, are statistically indistinguishable. However, physically, a blend of two narrow lines from photoionized matter seems to be preferable to emission of a relativistically broadened line from an ionized accretion disk; (c) The bulk of the Compton reflection continuum originates in neutral matter, and is therefore associated with the narrow FeK line at 6.4 keV: they are most likely emitted by distant matter.

Nicastro, Fabrizio↗

The Sombrero: An Edge-On Spiral: Halo Dynamics, A Massive Dark Object and XRBS

We present an analysis of the XMM-Newton and Chandra ACIS-S observations of the LINER nucleus of the Sombrero galaxy and we discuss possible explanations for its very sub-Eddington luminosity by complementing the X-ray results with high angular resolution observations in other bands. The X-ray investigation shows a hard (Gamma=1.89) and moderately absorbed ( N(sub H) = 1.8 x l0(exp 21)/sq cm) nuclear source of 1.5 x l0(exp 40) erg/s in the 2-10 keV band, surrounded by hot gas at a temperature of approx. 0.6 keV. The bolometric nuclear luminosity is at least approx. 200 times lower than expected if mass accreted on the supermassive black hole, that HST shows to reside at the center of this galaxy, at the rate predicted by the spherical and adiabatic Bondi accretion theory and with the high radiative efficiency of a standard accretion disc. The low luminosity, coupled to the observed absence of Fe-K emission in the nuclear spectrum, indicates that such a disc is not present. This nucleus differs from bright unobscured AGNs also for the lack of high flux variability and of prominent broad Halpha emission. However, it is also too faint for the predictions of simple radiatively inefficient accretion taking place at the Bondi rate; it could be too radio bright, instead, for radiatively inefficient accretion that includes strong mass outflows or convection. This discrepancy could be solved by the possible presence of nuclear radio jets. An alternative explanation of the low luminosity, in place of radiative inefficiency, could be unsteady accretion.

Mushotzky, Richard F.↗

Chandra Observation of the Core of the Galaxy Cluster AWM 7

We present results from a Chandra observation of the core region of the nearby X-ray bright galaxy cluster AWM 7. There are blob-like substructures, which are seen in the energy band 2-10 keV, within 10 kpc (20") of the cD galaxy NGC 1129, and the brightest sub-peak has a spatial extent more than 4 kpc. We also notice that the central soft X-ray peak is offset from the optical center by 1.3 kpc. These structures have no correlated features in optical, infrared, or radio band. Energy spectrum of the hard sub-peak indicates a temperature higher than 3 keV with a metallicity less than 0.3 solar, or a power-law spectrum with photon index approximately 1.2. A hardness ratio map and a narrow Fe-K band image jointly indicate two Fe-rich blobs symmetrically located around the cD galaxy, with the direction perpendicular to the sub-peak direction. In larger scales (r less than 60 kpc), the temperature gradually drops from 4 keV to 2 keV toward the cluster center and the metal abundance rises steeply to a peak of 1.5 solar at r approximately equal to 7 kpc. These results indicate that a dynamical process is going on in the central region of AWM 7, which probably creates heated gas blobs and drives metal injection.

Furusho, T.↗

The Astro-E2 Mission

The Astro-E2 observatory is a rebuild of the original Astro-E observatory that was lost during launch in February 2000. It is scheduled for launch into low earth orbit on a Japanese M-V rocket in early 2005. The Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency, is developing the observatory with major contributions from the US. The three instruments on the observatory are the high-resolution x-ray spectrometer (the XRS) featuring a 30-pixel x-ray microcalorimeter array, a set of four CCD cameras (the XIS) and a combination photo-diode/scintillator detector system (the HXD) that will extend the band pass up to nearly 700 keV. A significant feature of Astro-E2 is that all of the instruments are coaligned and operated simultaneously. With its high spectral resolution and collecting area for spectroscopy above 1 keV, Astro-E2 should enable major discovery space and pioneer new technology for use in space. Prime areas for investigation are supernova remnants, active galaxies and the measurement of black hole properties via relativistically-broadened Fe-K emission galaxies. A number of enhancements have been made for the Astro-E2/XRS, including a higher resolution microcalorimeter array, ii mechanical cooler for longer cryogen life, and an improved in-flight calibration system. The Astro-E2/XIS has also been improved to include two back-side-illuminated CCDs to enhance the low energy response. Improvements have also been made to the x-ray mirrors used for both the XRS and XIS to sharpen the point spread function and reduce the effects of stray light. In this talk we will present the essential features of Astro-E2, paying particular attention to the enhancements, and describe the major scientific strengths of the observatory.

Kelley, Richard L.↗

ART: Surveying the Local Universe at 2-11 keV

The Astronomical Rontgen Telescope (ART) is a medium-energy x-ray telescope system proposed for the Russian-led mission Spectrum Rontgen-Gamma (SRG). Optimized for performance over the 2-11-keV band, ART complements the softer response of the SRG prime instrument-the German eROSITA x-ray telescope system. The anticipated number of ART detections is 50,000-with 1,000 heavily-obscured (N(sub H)> 3x10(exp 23)/sq cm) AGN-in the SRG 4-year all-sky survey, plus a comparable number in deeper wide-field (500 deg(sup 2) total) surveys. ART's surveys will provide a minimally-biased, nearly-complete census of the local Universe in the medium-energy x-ray band (including Fe-K lines), at CCD spectral resolution. During long (approx.100-ks) pointed observations, ART can obtain statistically significant spectral data up to about 15 keY for bright sources and medium-energy x-ray continuum and Fe-K-line spectra of AGN detected with the contemporaneous NuSTAR hard-x-ray mission.

O'Dell, S. L.↗

X-Ray Calorimeter Arrays for Astrophysics

High-resolution x-ray spectroscopy is a powerful tool for studying the evolving universe. The grating spectrometers on the XMM and Chandra satellites started a new era in x-ray astronomy, but there remains a need for instrumentation that can provide higher spectral resolution with high throughput in the Fe-K band (around 6 keV) and can enable imaging spectroscopy of extended sources, such as supernova remnants and galaxy clusters. The instrumentation needed is a broad-band imaging spectrometer - basically an x-ray camera that can distinguish tens of thousands of x-ray colors. The potential benefits to astrophysics of using a low-temperature calorimeter to determine the energy of an incident x-ray photon via measurement of a small change in temperature was first articulated by S. H. Moseley over two decades ago. In the time since, technological progress has been steady, though full realization in an orbiting x-ray telescope is still awaited. A low-temperature calorimeter can be characterized by the type of thermometer it uses, and three types presently dominate the field. The first two types are temperature-sensitive resistors - semiconductors in the metal-insulator transition and superconductors operated in the superconducting-normal transition. The third type uses a paramagnetic thermometer. These types can be considered the three generations of x-ray calorimeters; by now each has demonstrated a resolving power of 2000 at 6 keV, but only a semiconductor calorimeter system has been developed to spaceflight readiness. The Soft X-ray Spectrometer on Astro-H, expected to launch in 2013, will use an array of silicon thermistors with I-IgTe x-ray absorbers that will operate at 50 mK. Both the semiconductor and superconductor calorimeters have been implemented in small arrays, kilo-pixel arrays of the superconducting calorimeters are just now being produced, and it is anticipated that much larger arrays will require the non-dissipative advantage of magnetic thermometers.

Kilbourne, Caroline A.↗

An Overview of High-Resolution, Non-Dispersive, Imaging Spectrometers for High-Energy Photons

High-resolution x-ray spectroscopy has become a powerful tool for studying the evolving universe. The grating spectrometers on the XMM and Chandra satellites initiated a new era in x-ray astronomy. Despite their successes, there is still need for instrumentation that can provide higher spectral resolution with high throughput in the Fe-K band and for extended sources. What is needed is a non-dispersive imaging spectrometer - essentially a 14-bit x-ray color camera. And a requirement for a nondispersive spectrometer designed to provide eV-scale spectral resolution is a temperature below 0.1 K. The required spectral resolution and the constraints of thermodynamics and engineering dictate the temperature regime nearly independently of the details of the sensor or the read-out technology. Low-temperature spectrometers can be divided into two classes - - equilibrium and non-equilibrium. In the equilibrium devices, or calorimeters, the energy is deposited in an isolated thermal mass and the resulting increase in temperature is measured. In the non-equilibrium devices, the absorbed energy produces quantized excitations that are counted to determine the energy. The two approaches have different strong points, and within each class a variety of optimizations have been pursued. I will present the basic fundamentals of operation and the details of the most successful device designs to date. I will also discuss how the measurement priorities (resolution, energy band, count rate) influence the optimal choice of detector technology.

Kilbourne, Caroline↗

Spectral and Timing Nature of the Symbiotic X-Ray Binary 4U 1954+319: The Slowest Rotating Neutron Star in AN X-Ray Binary System

The symbiotic X-ray binary (SyXB) 4U 1954+319 is a rare system hosting a peculiar neutron star (NS) and an M-type optical companion. Its approx. 5.4 hr NS spin period is the longest among all known accretion-powered pulsars and exhibited large (is approx. 7%) fluctuations over 8 yr. A spin trend transition was detected with Swift/BAT around an X-ray brightening in 2012. The source was in quiescent and bright states before and after this outburst based on 60 ks Suzaku observations in 2011 and 2012. The observed continuum is well described by a Comptonized model with the addition of a narrow 6.4 keV Fe-K alpha line during the outburst. Spectral similarities to slowly rotating pulsars in high-mass X-ray binaries, its high pulsed fraction (approx. 60%-80%), and the location in the Corbet diagram favor high B-field (approx. greater than 10(exp12) G) over a weak field as in low-mass X-ray binaries. The observed low X-ray luminosity (10(exp33)-10(exp35) erg s(exp−1)), probable wide orbit, and a slow stellar wind of this SyXB make quasi-spherical accretion in the subsonic settling regime a plausible model. Assuming a approx. 10(exp13) G NS, this scheme can explain the approx. 5.4 hr equilibrium rotation without employing the magnetar-like field (approx. 10(exp16) G) required in the disk accretion case. The timescales of multiple irregular flares (approx. 50 s) can also be attributed to the free-fall time from the Alfv´en shell for a approx. 10(exp13) G field. A physical interpretation of SyXBs beyond the canonical binary classifications is discussed.

accretion disks aEuro" binaries: symbiotic aEuro" ↗

The Design, Implementation, and Performance of the Astro-H SXS Calorimeter Array and Anti-Coincidence Detector

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The SXS has a square array of 36 microcalorimeters at the focal plane. These calorimeters consist of ion-implanted silicon thermistors and HgTe thermalizing x-ray absorbers. These devices have demonstrated a resolution of better than 4.5 eV at 6 keV when operated at a heat-sink temperature of 50 mK. We will discuss the basic physical parameters of this array, including the array layout, thermal conductance of the link to the heat sink, resistance function, absorber details, and means of attaching the absorber to the thermistor-bearing element. We will also present the thermal characterization of the whole array, including thermal conductance and crosstalk measurements and the results of pulsing the frame temperature via alpha particles, heat pulses, and the environmental background. A silicon ionization detector is located behind the calorimeter array and serves to reject events due to cosmic rays. We will briefly describe this anti-coincidence detector and its performance.

x-ray calorimeter↗

The Design, Implementation, and Performance of the Astro-H SXS Aperture Assembly and Blocking Filters

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV, enabling essential plasma diagnostics. The properties that make the SXS array a powerful x-ray spectrometer also make it sensitive to photons from the entire electromagnetic band, and particles as well. If characterized as a bolometer, it would have a noise equivalent power (NEP) of less than 4x10(exp -18) W/(Hz)0.5(exp 0.5). Thus it was imperative to shield the detector from thermal radiation from the instrument and optical and UV photons from the sky. Additionally, it was necessary to shield the coldest stages of the instrument from the thermal radiation emanating from the warmer stages. Both of these needs are addressed by a series of five thin-film radiation-blocking filters, anchored to the nested temperature stages, that block long-wavelength radiation while minimizing x-ray attenuation. The aperture assembly is a system of barriers, baffles, filter carriers, and filter mounts that supports the filters and inhibits their potential contamination. The three outer filters also have been equipped with thermometers and heaters for decontamination. We present the requirements, design, implementation, and performance of the SXS aperture assembly and blocking filters.

radiation - blocking filters↗

The Design, Implementation, and Performance of the Astro-H SXS Aperture Assembly and Blocking Filters

The calorimeter array of the JAXA Astro-H (renamed Hitomi) Soft X-ray Spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV. The properties that make the SXS a powerful x-ray spectrometer also make it sensitive to the entire electromagnetic band. If characterized as a bolometer, it would have a noise equivalent power (NEP) of < 4x10(exp -18) W/(Hz)0.5. Thus it was imperative to shield the detector from thermal radiation from the instrument and optical and UV photons from the sky. Additionally, it was necessary to shield the coldest stages of the instrument from the thermal radiation emanating from the warmer stages. These needs are addressed by a series of five thin-film radiation blocking filters that block long-wavelength radiation while minimizing x-ray attenuation. The SXS aperture assembly is a system of barriers, baffles, filter carriers, and filter mounts that supports the filters and inhibits their potential contamination. The three warmer filters also were equipped with thermometers and heaters for decontamination.

microcalorimeter↗