Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fault mitigation strategy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Model-Free Voltage Control Approach to Mitigate Motor Stalling and FIDVR for Smart Grids

Electric power networks are large and highly nonlinear dynamical systems that present unique challenges to control design. Though there is a large number of dynamic models for power system stability and control, many models are only useful with right assumptions and wrong for other tasks. Moreover, the dynamic behavior of the grid is increasingly complex under the banner of smart grids. These lead to the difficulty of developing appropriate dynamic modeling, and thus an efficient control strategy. To avoid such modeling challenges, here we present a novel dynamic voltage control strategy based on a model-free control (MFC) approach, requiring no modeling procedure. In particular, it focuses on fault-induced delayed voltage recovery (FIDVR) events, which require complex and accurate dynamic load models to replicate such events. This work utilizes MFC as an online controller to achieve the desired voltage stability under the FIDVR event. The proposed MFC strategy allows simple implementation and low computational cost for efficient mitigation of FIDVR. For benchmarking, a reasonably accurate dynamic performance model is explored. Simulation results with the IEEE 57 bus test network demonstrate the enhanced dynamic voltage profile for load buses having induction motors with the support of reactive power resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling-Based Assessment of Deep Seismic Potential Induced by Geologic Carbon Storage

Induced seismicity is an inherent risk associated with geologic carbon storage (GCS) in deep rock formations that could contain undetected faults prone to failure. Modeling-based risk assessment has been implemented to quantify the potential of injection-induced seismicity, but typically simplified multiscale geologic features or neglected multiphysics coupled mechanisms because of the uncertainty in field data and computational cost of field-scale simulations, which may limit the reliable prediction of seismic hazard caused by industrial-scale CO 2 storage. The degree of lateral continuity of the stratigraphic interbedding below the reservoir and depth-dependent fault permeability can enhance or inhibit pore-pressure diffusion and corresponding poroelastic stressing along a basement fault. In conclusion, this study presents a rigorous modeling scheme with optimal geological and operational parameters needed to be considered in seismic monitoring and mitigation strategies for safe GCS.

58 GEOSCIENCES↗

Enhancing the distribution grid resilience using cyber-physical oriented islanding strategy

The increasing penetration of distributed generations enables an innovative operation paradigm that allows islanded operation to enhance the resilience of the distribution grid. In this study, a cyber-physical oriented islanding strategy is proposed by coordinating centralised and distributed control to achieve seamless islanding transition and operational flexibility in emergency conditions. A cyber-physical control structure is developed to mitigate various disturbances (e.g. emergencies or fluctuations) according to different operation conditions. Specifically, the distributed fault isolation and seamless islanding transition are coordinated to mitigate the outage caused by unplanned islanding, while a secondary control is proposed to support primary control by reducing the power fluctuations during islanded operation. With a rapid response speed, the local cyber-physical devices are coordinated to accomplish islanding separation by selecting a feasible islanded area even under an unplanned islanding situation. A field test was conducted on a practical distribution network in China, and the results demonstrated the effectiveness and feasibility of the proposed islanding strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Exponential Backoff and Its Security Implications for Safety-Critical OT Protocols over TCP/IP Networks

The convergence of Operational Technology (OT) and Information Technology (IT) networks has become increasingly prevalent with the growth of Industrial Internet of Things (IIoT) applications. This shift, while enabling enhanced automation, remote monitoring, and data sharing, also introduces new challenges related to communication latency and cybersecurity. Oftentimes, legacy OT protocols were adapted to the TCP/IP stack without an extensive review of the ramifications to their robustness, performance, or safety objectives. To further accommodate the IT/OT convergence, protocol gateways were introduced to facilitate the migration from serial protocols to TCP/IP protocol stacks within modern IT/OT infrastructure. However, they often introduce additional vulnerabilities by exposing traditionally isolated protocols to external threats. This study investigates the security and reliability implications of migrating serial protocols to TCP/IP stacks and the impact of protocol gateways, utilizing two widely used OT protocols: Modbus TCP and DNP3. Our protocol analysis finds a significant safety-critical vulnerability resulting from this migration, and our subsequent tests clearly demonstrate its presence and impact. A multi-tiered testbed, consisting of both physical and emulated components, is used to evaluate protocol performance and the effects of device-specific implementation flaws. Through this analysis of specifications and behaviors during communication interruptions, we identify critical differences in fault handling and the impact on time-sensitive data delivery. The findings highlight how reliance on lower-level IT protocols can undermine OT system resilience, and they inform the development of mitigation strategies to enhance the robustness of industrial communication networks.

DNP3↗

Mitigating commutation failures in HVDC systems with SFCL deployment

Commutation failures represent a prevalent issue encountered in line-commutated-converter high voltage direct current (LCC-HVDC) systems. As the widespread deployment of HVDC systems continues, the risk associated with commutation failures increases, posing a growing threat to power grids due to their potential to trigger severe consequences, including cascading failures and widespread blackouts. This research paper aims to address the significant issue of commutation failure within direct current (DC) systems through advocating for the use of resistive-type Superconducting Fault Current Limiters (R-SFCLs). To substantiate the efficacy of this proposed strategy, an array of simulations are executed using the PSCAD/EMTDC software. This comprehensive study investigates the performance characteristics of R-SFCLs configured with varying resistance values, scrutinizing their response under diverse fault resistance scenarios and distinct fault initiation times within the LCC-HVDC system. The outcomes of these simulations are that SFCLs confer significant advantages for mitigating commutation failures, surpassing traditional mitigation methods in terms of effectiveness. Consequently, SFCLs emerge as an optimal solution to prevent commutation failures in the HVDC systems.

Commutation failure↗

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reliable edge machine learning hardware for scientific applications

Extreme data rate scientific experiments create massive amounts of data that require efficient ML edge processing. This leads to unique validation challenges for VLSI implementations of ML algorithms: enabling bit-accurate functional simulations for performance validation in experimental software frameworks, verifying those ML models are robust under extreme quantization and pruning, and enabling ultra-fine-grained model inspection for efficient fault tolerance. We discuss approaches to developing and validating reliable algorithms at the scientific edge under such strict latency, resource, power, and area requirements in extreme experimental environments. We study metrics for developing robust algorithms, present preliminary results and mitigation strategies, and conclude with an outlook of these and future directions of research towards the longer-term goal of developing autonomous scientific experimentation methods for accelerated scientific discovery.

Baldi, Tommaso↗

A cryogenic muon tagging system based on kinetic inductance detectors for superconducting quantum processors

Ionizing radiation has emerged as a potential limiting factor for superconducting quantum processors, inducing quasiparticle bursts and correlated errors that challenge fault-tolerant operation. Atmospheric muons are particularly problematic due to their high energy and penetration power, making passive shielding ineffective. Therefore, monitoring the real-time muon flux is crucial to guide the development of alternative error-correction or mitigation strategies. We present the design, simulation, and first operation of a cryogenic muon-tagging system based on kinetic inductance detectors (KIDs), developed as a stand-alone cryogenic particle-tagging module for superconducting quantum processors. The system consists of two KIDs arranged in a vertical stack and operated at ∼20 mK. Monte Carlo simulations based on Geant4 guided the prototype design and provided reference expectations for muon-tagging efficiency and accidental coincidences due to ambient γ-rays. We observed a muon-induced coincidence rate among the top and bottom detectors of (192 ± 9) $\times\,10^{-3}$ events s$^{−1}$, in excellent agreement with the Monte Carlo prediction. The prototype achieves a muon-tagging efficiency of about 90% with negligible dead time. These results demonstrate the feasibility of operating a muon-tagging system at millikelvin temperatures and represent a key step toward the integration of cryogenic veto systems with multi-qubit chips to mitigate muon-induced errors.

Mariani, Ambra [INFN, Rome] (ORCID:000000028184857↗

Dynamic Restoration Strategy for Distribution System Resilience Enhancement

In electric power distribution systems, distributed energy resources (DERs) can act as controllable power sources and support utility operators to minimize power outages after extreme weather events (e.g., hurricane, earthquake, wildfire) and thus help enhance the grid's resilience. Meanwhile, the influences of extreme events and the capabilities of DERs are dynamic and difficult to predict. Hence, the desired distribution system restoration strategy should be able to evolve according to real-time fault/disturbance information and the availability of DERs. In this paper, we propose a new dynamic restoration strategy for distribution systems to enhance system resilience against potential hazards. An efficient reconfiguration algorithm is developed to eliminate the use of integer variables to relieve the computational burden. Model predictive control is implemented to adjust the system topology and DER operation set points based on the updated fault information and DER forecasts. The effectiveness of the proposed restoration model in enhancing distribution system resilience is validated through an IEEE 123-bus test system. Simulation results also validate that the proposed restoration model can mitigate the occurrence of unexpected events and the fluctuations of DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Managing technical debt across large-scale control systems

This presentation provides a comprehensive overview of technical debt in the context of control systems for large-scale physics facilities. We will explore its various forms, common causes, and potential consequences on system reliability, maintainability, and upgradability. Drawing on experiences from multiple projects, we will present a range of strategies for proactively managing technical debt, including best practices in design, development, testing, and documentation, as well as reactive approaches for identifying and mitigating existing issues. The presentation will also emphasize the importance of a collaborative approach and the use of modern tools, like fault tracking systems, to ensure the long-term health and success of control systems in our field.

Watts, Adam [Fermilab]↗

Securing Grid-interactive Efficient Buildings (GEB) through Cyber Defense and Resilient System (CYDRES)

The DOE CYDRES project is driven by the urgent need to address critical research gaps in the domain of cyber-physical security of smart buildings, including Grid-interactive Efficient Buildings (GEBs). CYDRES, a real-time advanced building resilient platform, aims to enhance the cyber-attack-immune capabilities of buildings through multi-layered prevention, detection, and adaptation mechanisms. CYDRES consists of five key modules: a multi-layer network analyzer, an Automatic Fault Detection, Diagnosis, and Prognosis (AFDDP) framework, an intelligent mode selector, a cyber-resilient control framework, and a situation awareness platform. The Network Analyzer employs a data-driven framework that includes a protocol state learning tool and a CRF (Conditional Random Field) command validator. In Hardware-In-the-Loop (HIL) testbeds, it achieved 100% detection accuracy with a false alarm rate of 3%, validating its efficacy in identifying selected cyber-attacks. The AFDDP framework leverages pattern matching, PCA (Principal Component Analysis)-based strategies, and a DBN (Dynamic Bayesian Network)-based fault diagnosis approach to pinpoint the causes of physical system abnormalities using Building Automation System (BAS) data. In HIL experiments, the AFDDP module attained a detection accuracy of over 95% with a false alarm rate below 7%. Additionally, the fault detector utilized machine learning (Random Forest) and deep learning (Multi-Layer Perceptron) methods with acoustic sensor data to achieve a 100% fault detection accuracy in Heating, Ventilation, and Air-Conditioning (HVAC) equipment. The Mode Selector offered real-time impact analysis, allowing immediate actions to protect BASs in the face of emerging threats. The cyber-resilient control framework included an adaptive Model Predictive Control (MPC) and a measurement compensator, reducing temperature violations by up to 94% and improving the total demand flexibility by up to 70% in HIL experiments. Such HIL experiments covered a cyber-attack case and a physical fault case, showcasing CYDRES’ efficiency in maintaining operational continuity during threats. The situation awareness platform in Grafana enhanced real-time threat detection and response visualization, augmenting the operational awareness for building operators. CYDRES demonstrated high technical effectiveness in various test scenarios, particularly in HIL environments. The project's phased development approach ensured efficient use of resources, highlighting its practical feasibility and readiness for commercialization. By enhancing the security and resilience of building operations, CYDRES represents a significant advance in mitigating risks associated with cyber-physical systems, thereby enhancing public confidence in the safety of modern building infrastructure. Future directions for the project include expanding testing protocols, refining AFDDP methodologies, exploring more comprehensive resilient control strategies, and testing in real commercial buildings.

42 ENGINEERING↗

Numerical Simulations of Geologic Storage Reservoir Management to Support Risk Mitigation Evaluation

This report provides a detailed description of a set of numerical simulations that represent reservoir behavior over time in response to different operational decision scenarios for detection of potential leakage and reduction or avoidance of leakage impact at a hypothetical geological carbon storage (GCS) site. These simulations serve as the basis for a series of GCS leakage risk forecasts that are to be developed using the National Risk Assessment Partnership’s Open-Source Integrated Assessment Model (NRAP-Open-IAM), and a demonstration of a simple decision support workflow for evaluation of mitigation strategies based on results of those system model forecasts. This risk assessment and decision support study is forthcoming. Four injection scenarios were considered: a constant rate carbon dioxide (CO 2 ) injection case (base case), a case with CO 2 injection rate adjustment, a case with early termination of injection operations, and a case with brine extraction. CO 2 injection operations were controlled to ensure that the pressure transient remains below the defined manageable reservoir fracture pressure, with consideration shown to hypothetical locations within the modeled spatial domain where the overburden was weaker and lower transient pressure increases were allowable. Additionally, a brine extraction alternative was considered as a reservoir management and risk mitigation option to reduce reservoir pressure, steer the plume away from any hypothetical geohazard such as fault as needed, and enhance storage capacity. Such operational actions contribute to risk management overtime. This study explores the potential utility of reservoir management for risk reduction at GCS sites. This study shows that the injection design may modify the time to CO 2 breakthrough at a legacy well; in particular, these results show that brine extraction can add value for mitigating risk both by delaying leakage and reducing pressure build-up. For the scenario considered, both pressure plots and pressure distributions demonstrate that pressure build-up was decreased by 3% with brine extraction. Additionally, extraction of brine afforded enhancement of CO 2 storage capacity by 5% compared to the base case. These findings suggest that brine extraction has substantial potential to steer the risk-related reservoir effects away from known geohazards (e.g., faults and legacy wells) by conducting pressure transient effects and CO 2 plume movement toward the production well. Injection rate adjustment scenarios considered in this study show potential value for managing both reservoir pressure transients and CO 2 plume behavior. Operational actions for reducing injection and/or early termination of injection (as compared to the base case), however, require careful design; tailoring both the extent and timing of injection rate adjustment over the injection and post-injection operational period must be thoroughly planned to balance maximizing storage and minimizing subsurface environmental risk. The study also gives preliminary consideration to the effectiveness that monitoring strategy may play in providing useful information to inform reservoir management decisions for risk reduction. Two types of monitoring were considered: 1) pressure build-up or pressure transient; and 2) potential leakage detection from a CO 2 mass or plume. Four hypothetical legacy wells, two plugged and two abandoned, were placed in the model domain. Monitoring along these wells was measured over time in individual stacked reservoir formations and shale formations to support risk mitigation decisions, especially operational decisions that assisted in risk reduction. These simulations will serve as the basis for a series of GCS leakage risk forecasts that are to be developed using NRAP’s Open-IAM, and demonstration of a simple decision support workflow for comparative assessment of mitigation alternatives based on results of those system model forecasts. This risk assessment and decision support study is forthcoming.

54 ENVIRONMENTAL SCIENCES↗

Autoencoder-Based Sensor Drift Detection and Mitigation for Resilient Charging Systems

This work presents an autoencoder-based approach for sensor signal reconstruction and drift detection for charging systems. The proposed strategy is implemented within a Simulink-based system framework and evaluated under multiple operating conditions. An autoencoder with 8 neurons in the bottleneck layer is adopted, achieving accurate reconstruction across 10 variables and strong agreement with the physical sensor readings under normal conditions. In the case of a sensor fault, the autoencoder reconstruction remains closer to the expected true value compared to the corrupted measurement. Furthermore, feeding the autoencoder-reconstructed signal value back into the control framework in place of the faulty sensor signal leads to improved power monitoring. These results highlight the potential of autoencoder-based virtual sensing to extend the concept of resiliency to all components of the charging system, including sensors.

Rezende Da Costa Reis Kimpara, Renata [ORNL] (ORCI↗

5-2428: Coupled Investigation of Fracture Permeability Impact on Reservoir Stress and Seismic Slip Behavior [Slides]

Our goal is to develop, apply and validate a holistic thermal, hydrologic, mechanical, and chemical (THMC) workflow that also includes evaluation of induced seismic slip in EGS reservoirs. We will integrate experimental and modelling approaches to reduce parameter uncertainty and better integrate friction constitutive laws for faults to improve our ability to predict and mitigate seismic hazard at Utah FORGE and future EGS sites. We propose a novel approach that incorporates 3D physics-based Earthquake simulations in THMC models, using lab measurements of friction parameters, herein referred to as “THMC+E” models. These simulations will enable exploration of various circumstances that may hinder EGS success and develop mitigation strategies.

58 GEOSCIENCES↗

A hardware-in-the-loop (HIL) testbed for cyber-physical energy systems in smart commercial buildings

In recent years, there has been a growing trend toward the development of smart buildings that rely on cyber-physical systems (CPS) to optimize occupant comfort, safety, and energy efficiency. To ensure the reliable and efficient operation of CPS with designed control strategies, it is important to evaluate their performance under various scenarios before deploying them in the real world. This is where a Hardware-in-the-loop (HIL) testbed designed for studying sensor and control-related studies in smart buildings can be highly valuable. With the growing threat of cyber-attacks and physical faults targeting smart buildings, it is essential to ensure the security of building operations. A HIL testbed can emulate cyber-attack and physical fault scenarios, allowing researchers to develop and test threat detection and mitigation algorithms. This enables researchers to identify potential issues and optimize the algorithms in a safe and controlled environment before they are deployed in real-world settings, reducing the risk of failures that can negatively impact occupant comfort, safety, and energy efficiency. Therefore, this paper developed a HIL testbed designed for cyber-physical energy systems (e.g. buildings automation system (BAS)) in smart commercial buildings. The HIL testbed is comprised of a real-time building and Heating, Ventilation, and Air-Conditioning (HVAC) emulator using Modelica-based dynamic models, a set of BAS controllers, and a BAS computer server. The data generation capability of the HIL testbed is demonstrated by tracking normal and faulty operating data in the BAS, as well as monitoring detailed network traffic in the local BAS network. Here, this study further demonstrates the HIL testbed’s capability by conducting case studies on real-time physical fault and cyber-attack experiments using a Department of Energy (DOE) prototype commercial building. It is anticipated that the fully functional HIL testbed will be utilized for a variety of sensor and control-related studies, including but not limited to testing, developing, validating of different HVAC control strategies, fault detection & diagnosis, energy monitoring and analysis, cyber security study, etc.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Developing a Disaster-Ready Power Grid Agent Through Geophysically-Informed Fault Event Scenarios

Management of the nation’s power grid over the coming decades will need to factor multiple climate-driven threats to the power system that can be stressful or even detrimental to its operations. During disasters, grid operators suffer from cognitive overload where the electric grid is severely impacted by the weather, yet grid operators have limited awareness of these factors. Meanwhile, the electric grid is facing an explosion of data coming from a variety of sources which can enable the operator to evaluate the risks and develop mitigation strategies against hazardous events. In this work, we processed heterogeneous environmental and power grid data to learn and model grid behavior caused by extreme weather events. In this study, we focused on two weather-driven hazards, hurricanes and wildfires, which were analysed for the electric grid of Texas. We the used this data to train a Reinforcement Learning (RL) agent by analysing and predicting future behaviour of the grid during those hazard events. All these parts are incorporated in one framework to have a geophysically informed power simulators that can be used to train RL agents.

electic grid, reinforcement learning, climate adap↗

Attack-resilient algorithms and testbed federation for wide-area protection and control in smart grid

Today’s energy infrastructure is undergoing a massive transformation across all generation, transmission, and distribution systems to provide reliability, efficiency, and sustainability to the power system network. During the past 10 years, there has been a remarkable enhancement in developing close-loop wide-area protection and control (WAPAC) applications, such as automatic generation control (AGC), wide-area protection scheme (WAPS), synchrophasor-based wide-area voltage control system (WAVCS), etc., in the energy management system (EMS) to provide an adequate situational awareness to control center operators during physical disturbances and natural events. The rapid digitalization, unencrypted communication, and numerous data-sharing devices have increased digital access points that have exposed the grid network to countless cyberattacks pertinent to the WAPAC cybersecurity. Given the amount of complex grid network coupled with legacy infrastructures, it is untrustworthy to completely rely on information technology (IT)-based conventional security measures to defend against evolving cyberattacks. Hence, there is a compelling need to go beyond the traditional paradigm of ‘security by obscurity’ and ‘bolt-on’ security measures, and develop a suite of innovative security solutions at multiple layers to transform the current “fault-resilient” grid into “fault and attack-resilient” grid of the future. This dissertation specifically focuses on developing application-specific attack-resilient solutions for critical WAPAC applications in the smart grid. The first part of the study, Attack-Resilient Wide-Area Protection Scheme, presents a cyber-physical attack-resilient system (CPARS) for WAPS, where two anomaly detection methods are proposed to detect multi-level cyberattacks followed by the rules-based intrusion mitigation system (RIMS) to initiate effective mitigation strategies, tailored to these attacks, to restore the normal grid operation after disturbances. The first anomaly detection component, Machine learning-based Anomaly Detection for Centralized WAPS, discusses a novel architecture and methodology for developing a machine-learning-based anomaly detection system (ADS) for the centralized wide-area protection system (CWAPS) by applying the variational mode decomposition (VMD) technique and decision tree (DT) algorithms using cyber logs and synchrophasor measurements. The second component, Multi-Agent-based Anomaly Detection for Decentralized WAPS, presents a two-level hierarchical multi-agent-based decentralized WAPS against the system-aware stealthy cyber-attacks. Finally, for the RIMS, the state transition diagram-based mitigation measures are defined based on the grid operation states and experimental testing and evaluation are presented in a cyber-physical testbed environment. The second part of the study, Attack-Resilient Wide-Area Voltage Control System, addresses the existing vulnerabilities in the wide-area voltage control system (WAVCS), presents the methodology for performing an impact analysis during data integrity attacks, and proposes a data-driven attackresilient system (DARS) by incorporating machine learning-based ADS and rules-based anomaly mitigation system (RAMS) to detect these attacks and provide necessary mitigation actions to maintain the transient voltage stability after disturbances. Finally, the third part, Networked Federation Testbed (NEFTSec) for Smart Grid Cybersecurity, focuses on developing an interconnected federated testbed through a common network like the internet, describes its conceptual architectures, and also presents its design components for experimental testing, validation, and evaluation. Further, it presents the co-simulation interface algorithm (CIA) to facilitate the geographically-dispersed real-time distributed simulation (GD-RTDS) during the cyber-physical federation. In general, this dissertation presents innovative attack-resilient solutions for WAPAC applications that are experimentally tested and evaluated using the PowerCyber testbed and NEFTSec platform to accelerate the transition of state-of-the-art research works to the real-field deployments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Restoration Strategy for Distribution System Resilience Enhancement

In electric power distribution systems, distributed energy resources (DERs) can act as controllable power sources and support utility operators to minimize power outages after extreme weather events (e.g., hurricane, earthquake, wildfire) and thus help enhance the grid's resilience. Meanwhile, the influences of extreme events and the capabilities of DERs are dynamic and difficult to predict. Hence, the desired distribution system restoration strategy should be able to evolve according to real-time fault/dis-turbance information and the availability of DERs. In this paper, we propose a new dynamic restoration strategy for distribution systems to enhance system resilience against potential hazards. An efficient reconfiguration algorithm is developed to eliminate the use of integer variables to relieve the computational burden. Model predictive control is implemented to adjust the system topology and DER operation set points based on the updated fault information and DER forecasts. The effectiveness of the proposed restoration model in enhancing distribution system resilience is validated through an IEEE 123-bus test system. Simulation results also validate that the proposed restoration model can mitigate the occurrence of unexpected events and the fluctuations of DERs.

distributed energy resources (DERs)↗