Hanford Single-Shell Tank Leak Causes and Locations - 241-BY and 241-TY Farm

This document identifies 241-BY Tank Farm (BY Farm) and 241-TY Tank Farm (TY Farm) lead causes and locations for the 100 series leaking tanks (241-BY-103, 241-TY-103, 241-TY-104, 241-TY-105 and 241-TY-106) identified in RPP-RPT-43704, Hanford BY Farm Leak Assessments Report, and in RPP-RPT-42296, Hanford TY Farm Leak Assessments Report. This document satisfies the BY and TY Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

Girardot, Crystal L.↗

Missouri Agricultural Energy Saving Team-A Revolutionary Opportunity (MAESTRO)

The Missouri Agricultural Energy Saving Team-A Revolutionary Opportunity (MAESTRO) program brought together a team of representatives from government, academia, and private industry to enhance the availability of energy efficiency services for small livestock producers in the State of Missouri. The Missouri Department of Agriculture (MDA) managed the project via a subcontract with the University of Missouri (MU), College of Agriculture Food and Natural Resources, MU Extension, the MU College of Human Environmental Sciences, the MU College of Engineering, and the Missouri Agricultural and Small Business Development Authority (MASBDA). MU teamed with EnSave, Inc, a nationally-recognized expert in agricultural energy efficiency to assist with marketing, outreach, provision of farm energy audits and customer service. MU also teamed with independent home contractors to facilitate energy audits of the farm buildings and homes of these livestock producers. The goals of the project were to: (1) improve the environment by reducing fossil fuel emissions and reducing the total energy used on small animal farms; (2) stimulate the economy of local and regional communities by creating or retaining jobs; and (3) improve the profitability of Missouri livestock producers by reducing their energy expenditures. Historically, Missouri scientists/engineers conducted programs on energy use in agriculture, such as in equipment, grain handling and tillage practices. The MAESTRO program was the first to focus strictly on energy efficiency associated with livestock production systems in Missouri and to investigate the applicability and potential of addressing energy efficiency in animal production from a building efficiency perspective. A. Project Objectives The goal of the MAESTRO program was to strengthen the financial viability and environmental soundness of Missouri's small animal farms by helping them implement energy efficient technologies for the production facility, farm buildings, and the homes on these farms. The expected measurable outcomes of the project were to improve the environment and stimulate the economy by: • Reducing annual fossil fuel emissions by 1,942 metric tons of carbon dioxide equivalent, reducing the total annual energy use on at least 323 small animal farms and 100 farm homes by at least 8,000 kWh and 2,343 therms per farm. • Stimulating the economy by creating or retaining at least 69 jobs, and saving small animal farmers an average of $2,071 per farm in annual energy expenditures. B. Project Scope The MAESTRO team chose the target population of small farms because while all agriculture is traditionally underserved in energy efficiency programs, small farms were particularly underserved because they lack the financial resources and access to energy efficiency technologies that larger farms deploy. The MAESTRO team reasoned that energy conservation, financial and educational programs developed while serving the agricultural community could serve as a national model for other states and their agricultural sectors. The target population was approximately 2,365 small animal farm operations in Missouri, specifically those farms that were not by definition a confined animal feeding operation (CAFO). The program was designed to create jobs by training Missouri contractors and Missouri University Extension staff how to conduct farm audits. The local economy would be stimulated by an increase in construction activity and an increasing demand for energy efficient farm equipment. Additionally, the energy savings were deemed critical in keeping Missouri farms in business. This project leveraged funds using a combination of funds from the Missouri Department of Natural Resources’ Missouri Energy Center and its Soil and Water Conservation Program, from the state's Linked Deposits, MASBDA's agricultural loan guarantee programs, and through the in-kind contribution of faculty and staff time to the project from these agencies and MU. Several hundred Missouri livestock producers were contacted during the MAESTRO project. Of the livestock producers, 254 invited the team to conduct a farm energy assessment which complied with ASABE 612. A total of 147 livestock farm upgrades were implemented, representing 57.5 percent of the farms for which a farm energy assessment was completed. This represented a statewide average annual savings of 1,088,324 kWh and 75,516 therms. The team also reviewed the condition of the livestock producer’s home(s). A total of 106 home energy assessments were completed and 48 individual homes implemented their recommended upgrades, representing 45 percent of the farm homes for which an energy assessment was completed. This represented a statewide average annual savings of 323,029 kWh, and 769.4 therms. More of these farmers likely would have updated their homes but the funding to incentivize them fell short. In spite of the shortfall in incentive funds, some farmers still updated their homes as they saw the value in making these changes to their home.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessment of Offshore Wind Farm Effects on Sea Surface, Subsurface and Airborne Electronic Systems (Final Report)

Offshore wind energy is a valuable resource that can provide a significant boost to the US renewable energy portfolio. A current constraint to the development of offshore wind farms is the potential for interference to be caused by large wind farms on existing electronic and acoustical equipment such as radar and sonar systems for surveillance, navigation and communications. The US Department of Energy funded this study as an objective assessment of possible interference to various types of equipment operating in the marine environment where offshore wind farms could be installed. The objective of this project was to conduct a baseline evaluation of electromagnetic and acoustical challenges to sea surface, subsurface and airborne electronic systems presented by offshore wind farms. To accomplish this goal, the following tasks were carried out: (1) survey electronic systems that can potentially be impacted by large offshore wind farms, and identify impact assessment studies and research and development activities both within and outside the US, (2) engage key stakeholders to identify their possible concerns and operating requirements, (3) conduct first-principle modeling on the interactions of electromagnetic signals with, and the radiation of underwater acoustic signals from, offshore wind farms to evaluate the effect of such interactions on electronic systems, and (4) provide impact assessments, recommend mitigation methods, prioritize future research directions, and disseminate project findings. This report provides a detailed description of the methodologies used to carry out the study, key findings of the study, and a list of recommendations derived based the findings.

17 WIND ENERGY↗

Hanford Single-Shell Tank Leak Causes and Locations - 241-BY and 241-TY Farm

This document identifies 241-BY Tank Farm (BY Farm) and 241-TY Tank Farm (TY Farm) leak causes and locations for the 100-series leaking tanks in BY and TY Farm. The leak causes and locations report for all of the 100-series single-shell leaking tanks is one of the targets (M-045-91-T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F. The T04 target requires that the Department of Energy provide to State of Washington, Department of Ecology (Ecology) a report on the 100-series single-shell tanks which have been or will be identified as having leaked in RPP-32681, Rev. 0, Process to Assess Tank Farm Leaks in Support of Retrieval and Closure Planning, leak assessment reports. The leak assessment report for BY Farm, RPP-RPT-43704, Rev. 0A, Hanford BY-Farm Leak Assessments Report, lists one 100-series tank that either continues to be or is recommended to be classified as a leaking tank in BY Farm, 241-BY-103 (BY-103). The leak assessment report for TY Farm, RPP-RPT-42296, Rev, 0, Hanford TY-Farm Leak Assessments Report, lists four 100-series tanks that either continue to be or are recommended to be classified leaking tanks in TY Farm, 241-TY-103 (TY-103), 241-TY-104 (TY-104), 241-TY-105 (TY-105), and 241-TY-106 (TY-106). All of the other eleven 100-series tanks in BY Farm and two 100-series tanks in TY Farm are classified as “sound” or are identified in RPP-RPT-43704, Rev. 0A, and RPP-RPT-42296, Rev. 0, respectively, as requiring re-assessment of their classification per TFC-ENG-CHEM-D-42, Tank Leak Assessment Process. The TFC-ENG-CHEM-D-42 assessments are not part of the M-045-91-T04 target. This BY and TY Farm leak causes and locations document is part of a series of tank farm reports that identify leak causes and locations for 100-series leaking tanks. A summary and conclusions document will be issued, RPP-RPT-54909, Hanford Single-Shell Tank Leak Causes and Locations – Summary, that compiles the results from all of the leak causes and locations tank farm reports when they have been issued which will fulfill the T04 target requirements. The identification of four of the five leaking BY and TY Farm tank leak locations focused on the first indication of radiation detected in drywells as well as liquid level decreases as appropriate, with the exception of tank TY-104 which could not be identified. Leak detection laterals were not installed underneath the BY and TY Farm tanks. For TY Farm, direct pushes were installed in 2005 to further characterize the tank leaks which were used to collaborate with the drywell data. The BY and TY Farm leaking tanks were likely due to chemistry-corrosion from the storage of Tri-butyl phosphate (TBP) waste which is conducive to stress corrosion cracking and pitting. Thermal shock (rate of temperature rise) and tank construction conditions (cold weather ductile-to-brittle transition temperature impact effects) were also likely to have affected tank integrity. There appears to be very little contribution from tank design and liner bulging. However, some or all of the factors can act serially or together to contribute to tank liner failure. The leaking BY and TY Farm tanks all stored undiluted TBP waste whereas the sound tanks stored diluted TBP waste as well as other waste types.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Tank Farm Occupational Exposure and Risk Assessment Plan: Health Process Project (Rev.1)

The overall objective of the Hanford Tank Farm Occupational Exposure and Risk Assessment Plan (hereafter referred to as the “Assessment Plan”) is to provide the Tank Operations Contractor (TOC), Washington River Protection Solutions (WRPS), and the U.S. Department of Energy (DOE) with a plan for developing a transparent, peer-reviewed process for assessing potential health risks associated with worker exposures to chemical emissions from the Hanford tank farms. Revision 1 (2018) incorporates changes to the original draft plan prepared in 2016 to reflect updated strategies based on initial implementation of the recommended actions.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Hanford Single-Shell Tank Leak Causes and Locations - 241-SX Farm

This document identifies 241-SX Tank Farm (SX Farm) leak causes and locations for the 100 series leaking tanks (241-SX-107, 241-SX-108, 241-SX-109, 241-SX-111, 241-SX-112, 241-SX-113, 241-SX-114, and 241-SX-115) identified in RPP-ENV-39658, Rev. 0, Hanford SX-Farm Leak Assessments Report. This document satisfies the SX Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Single-Shell Tank Leak Causes and Locations - 241-A Farm

This document identifies 241-A Tank Farm (A Farm) leak causes and locations for the 100 series leaking tanks (241-A-104 and 241-A-105) identified in RPP-ENV-37956, Hanford A and AX Farm Leak Assessment Report. This document satisfies the A Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impact of GSA2018 Flow Update, Alternative Dispersion Model, and Increased Grid Resolution on Tank Closure Performance Assessments

The F-Area Tank Farm (FTF) and H-Area Tank Farm (HTF) Performance Assessments (PAs) involve simulations of radionuclide and chemical waste migration through groundwater to exposure points. These solute transport simulations are based on a circa 2004 “GSA/PORFLOW” flow model [WSRC-TR-2004-00106]. The GSA/PORFLOW model was significantly updated in 2016-2017 [SRNL-STI-2017-00008 Rev. 1]. Impacts of the “GSA2016” flow model on the F- and H-Tank Farm PAs were assessed in SRNL-STI-2017-00445, Impacts of Updated GSA Groundwater Flow Models on the FTF, HTF and SDF PAs. Since then (2018-2019) further revisions resulted in a “GSA2018” flow model [SRNL-STI-2018-00643], which has been adopted for the 2019 Saltstone PA revision [SRR-CWDA-2019-00001 Revision A]. This study assesses the impacts of the GSA2018 flow model on the FTF and HTF PAs. Also assessed are the impacts of an alternative plume dispersion model and increased grid resolution that have been incorporated in the 2019 Saltstone PA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Collaborative TPL Assessment of Wave Energy Converters and Farms

The Technology Performance Level (TPL) assessment is a holistic methodology to assess a wave energy converter (WEC) technology’s ability to achieve [continental grid] market competitiveness and acceptability via criteria-based consideration of key cost, performance, environmental, safety, and societal drivers. The TPL assessment can be applied at all technology development stages and associated technology readiness levels (TRLs).

Technology Performance Level↗

Load assessment of a wind farm considering negative and positive yaw misalignment for wake steering

Wake steering strategies are employed to increase the overall power production of wind farms by deflecting wakes of upstream turbines away from downstream ones. The gain in net power comes at the expense of increased fatigue loads experienced by downstream turbines. In this work we investigate performance and fatigue loading characteristics of a small farm consisting of five aligned International Energy Agency Wind Technology Collaboration Programme 15 MW wind turbines. A parametric study is performed where, for every wind direction from −20 to 20°, the yaw misalignment angle varies from −25 to 25°. This setup allows us to investigate asymmetries and identify optimal conditions for a given wind direction. In general, we find that positive yaw configurations are preferred and that yaw configurations that result in attractive power differences when compared to a baseline no-yaw scenario (25 %) come with significant increase in fatigue loading (we use the standard deviation and damage-equivalent load (DEL) of the blade-root, low-speed shaft, and tower-base moments as proxies for fatigue load). We find that for any given positive wind inflow angle, yaw angles between −2.5 and 15° yield power differences of 10 %–20 % over a no-yaw baseline, and positive yaw is preferred because of lower fatigue loading. For any given negative wind inflow angles, positive yaw also results in lower magnitudes of standard deviation and DEL for the channels investigated. A small power loss of up to 2 % is observed for some positive yaw angles under negative wind directions (as compared to symmetric negative yaw and positive wind cases), but improvements in terms of loads exceed 25 % and may be enough to justify a positive yaw configuration under negative winds as well. We show that such behavior can be explained by partial waking and the direction of the rotation of the rotor.

17 WIND ENERGY↗

Scaled Wind Farm Technology (SWiFT) Facility (Safety Assessment, Rev. 0)

This Safety Assessment (SA) documents the hazard analysis conducted for the Scaled Wind Farm Technology (SWiFT) Facility. The Sandia National Laboratories (SNL) Authorization Basis process requires Safety Assessment documents for all moderate-hazard industrial facilities. Together with the Primary Hazard Screening (PHS) Document [SNL11A00204), the SA documents the SWiFT safety basis, which is defined as the safety analysis and hazard controls that provide reasonable assurance that a DOE facility can be operated in a manner that adequately protects the workers, collocated/onsite workers, the public, and the environment. The SA specifically addresses the potential impact of hazards on the worker, collocated worker, and public.

17 WIND ENERGY↗

Conducting Industrial Hygiene Exposure Assessments at Scale Using Non-Parametric Upper Tolerance Limits at the Hanford Site - 20439

Chemical vapors are generated in the radioactive waste storage tanks at the Hanford Site due to ongoing chemical and radiological activity. Hanford's Tank Operations Contractor conducts exposure assessments for individual tank farms to identify, evaluate, and recommend controls or other worker protection measures for chemical, physical, and biological hazards present within each tank farm. These exposure assessments conform to the American Industrial Hygiene Association assessment strategy and recommended statistical procedures. The exposure assessment process involved manually processing tens of thousands of records that were collected over several years and entered into a central database. Working with Pacific Northwest National Laboratory, this process has been largely automated, providing a scalable analysis process that reduced processing time by over 90%, while providing defensible results and improved data quality. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Performance of a Spectral Wave Model at Predicting Wave Farm Impacts

For renewable ocean wave energy to support global energy demands, wave energy converters (WECs) will likely be deployed in large numbers (farms), which will necessarily change the nearshore environment. Wave farm induced changes can be both helpful (e.g., beneficial habitat and coastal protection) and potentially harmful (e.g., degraded habitat, recreational, and commercial use) to existing users of the coastal environment. It is essential to estimate this impact through modeling prior to the development of a farm, and to that end, many researchers have used spectral wave models, such as Simulating WAves Nearshore (SWAN), to assess wave farm impacts. However, the validity of the approaches used within SWAN have not been thoroughly verified or validated. Herein, a version of SWAN, called Sandia National Laboratories (SNL)-SWAN, which has a specialized WEC implementation, is verified by comparing its wave field outputs to those of linear wave interaction theory (LWIT), where LWIT is theoretically more appropriate for modeling wave-body interactions and wave field effects. The focus is on medium-sized arrays of 27 WECs, wave periods, and directional spreading representative of likely conditions, as well as the impact on the nearshore. A quantitative metric, the Mean Squared Skill Score, is used. Results show that the performance of SNL-SWAN as compared to LWIT is “Good” to “Excellent”.

environmental impacts↗

South African farm workers' interpretation of risk assessment data expressed as pictograms on pesticide labels

Pesticide companies and regulators in developing countries use the United Nations Food and Agricultural Organization (FAO) recommended pictograms on pesticide labels to communicate risk information based on toxicological and environmental risk assessment data. The pesticide label not only is often the only access people have to pesticide risk information, but also in many countries is a legally binding document. As a result of the crucial role pesticide labels play in protecting health and the environment and as a legal instrument, pictograms are used to overcome literacy challenges in transmitting pesticide risk information. Yet, this risk communication tool is often prone to misinterpretations of the risk information which results in hazardous exposures to pesticides for farm workers and end-users generally. In this paper, results are presented from a study with 115 farm workers on commercial vineyards in the Western Cape, South Africa, assessing their interpretations of 10 commonly used pictograms. A standardized questionnaire based on four commonly used pesticide labels was administered. Overall, 50% or more of the study farm workers had misleading, incorrect and critically confused interpretations of the label pictograms. Interpretations often reflected farm workers' social and cultural frames of reference rather than the technically intended risk information. For example, the pictogram indicating a pesticide's toxicity requires boots must be worn, evoked interpretations of 'dangerous to pedestrians' and 'don't walk through pesticides'. Furthermore, there was a gender variation in pictogram comprehension whereby males generally had more correct interpretations than females. This is a result both of a lack of training for women who are assumed to not work with pesticides, as well as a lack of pictograms relevant for female exposures. These findings challenge the viability of the United Nations current initiative to globally harmonize pictograms used on all chemical labels under the new Globally Harmonized System for the Classification and Labelling of Chemicals (GHS). Particularly as the GHS pictograms were not piloted prior to adoption of the system and represent complex risk assessment data such as chronic hazards. Public health and pesticide policy, backed by relevant research, need to address developing applicable and effective pesticide risk communication tools, particularly for developing country populations. Merely providing risk assessment derived information in a pictogram does not ensure that an end-user will interpret the message as intended and be able to make risk decisions which mitigate risks from exposures to pesticides or chemicals in general.

60 APPLIED LIFE SCIENCES↗

The importance of round-robin validation when assessing machine-learning-based vertical extrapolation of wind speeds

The extrapolation of wind speeds measured at a meteorological mast to wind turbine rotor heights is a key component in a bankable wind farm energy assessment and a significant source of uncertainty. Industry-standard methods for extrapolation include the power-law and logarithmic profiles. The emergence of machine-learning applications in wind energy has led to several studies demonstrating substantial improvements in vertical extrapolation accuracy in machine-learning methods over these conventional power-law and logarithmic profile methods. In all cases, these studies assess relative model performance at a measurement site where, critically, the machine-learning algorithm requires knowledge of the rotor-height wind speeds in order to train the model. This prior knowledge provides fundamental advantages to the site-specific machine-learning model over the power-law and log profiles, which, by contrast, are not highly tuned to rotor-height measurements but rather can generalize to any site. Furthermore, there is no practical benefit in applying a machine-learning model at a site where winds at the heights relevant for wind energy production are known; rather, its performance at nearby locations (i.e., across a wind farm site) without rotor-height measurements is of most practical interest. To more fairly and practically compare machine-learning-based extrapolation to standard approaches, we implemented a round-robin extrapolation model comparison, in which a random-forest machine-learning model is trained and evaluated at different sites and then compared against the power-law and logarithmic profiles. We consider 20 months of lidar and sonic anemometer data collected at four sites between 50 and 100 km apart in the central United States. We find that the random forest outperforms the standard extrapolation approaches, especially when incorporating surface measurements as inputs to include the influence of atmospheric stability. When compared at a single site (the traditional comparison approach), the machine-learning improvement in mean absolute error was 28 % and 23 % over the power-law and logarithmic profiles, respectively. Using the round-robin approach proposed here, this improvement drops to 20 % and 14 %, respectively. These latter values better represent practical model performance, and we conclude that round-robin validation should be the standard for machine-learning-based wind speed extrapolation methods.

17 WIND ENERGY↗

Cementitious Grout for Closing SRS High Level Waste Tanks - 12315

In 1997, the first two United States Department of Energy (US DOE) high level waste tanks (Tanks 17-F and 20-F: Type IV, single shell tanks) were taken out of service (permanently closed) at the Savannah River Site (SRS). In 2012, the DOE plans to remove from service two additional Savannah River Site (SRS) Type IV high-level waste tanks, Tanks 18-F and 19-F. These tanks were constructed in the late 1950's and received low-heat waste and do not contain cooling coils. Operational closure of Tanks 18-F and 19-F is intended to be consistent with the applicable requirements of the Resource Conservation and Recovery Act (RCRA) and the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) and will be performed in accordance with South Carolina Department of Health and Environmental Control (SCDHEC). The closure will physically stabilize two 4.92E+04 cubic meter (1.3 E+06 gallon) carbon steel tanks and isolate and stabilize any residual contaminants left in the tanks. Ancillary equipment abandoned in the tanks will also be filled to the extent practical. A Performance Assessment (PA) has been developed to assess the long-term fate and transport of residual contamination in the environment resulting from the operational closure of the F-Area Tank Farm (FTF) waste tanks. Next generation flowable, zero-bleed cementitious grouts were designed, tested, and specified for closing Tanks 18-F and 19-F and for filling the abandoned equipment. Fill requirements were developed for both the tank and equipment grouts. All grout formulations were required to be alkaline with a pH of 12.4 and to be chemically reducing with a reduction potential (Eh) of -200 to -400. Grouts with this chemistry stabilize potential contaminants of concern. This was achieved by including Portland cement and Grade 100 slag in the mixes, respectively. Ingredients and proportions of cementitious reagents were selected and adjusted to support the mass placement strategy developed by Savannah River Remediation (SRR) Closure Operations. Subsequent down selection was based on compressive strength and saturated hydraulic conductivity results. Fresh slurry property results were used as the first level of screening. A high range water reducing admixture and a viscosity modifying admixture were used to adjust slurry properties to achieve flowable grouts. Adiabatic calorimeter results were used as the second level screening. The third level of screening was used to design mixes that were consistent with the fill material parameters used in the F-Tank Farm Performance Assessment which was developed to assess the long-term fate and transport of residual contamination in the environment resulting from the operational closures. The cement and slag contents of a mix selected for filling Tanks 18-F and 19-F should be limited to no more than 125 and 210 lbs/cyd, respectively, to limit the heat generated as the result of hydration reaction during curing and thereby enable mass pour placement. Trial mixes with water to total cementitious materials ratios of 0.550 to 0.580 and 125 lbs/cyd of cement and 210 lbs/cyd of slag met the strength and permeability requirements. Mix LP no.8-16 was selected for closing SRS Tanks 18-F and 19-F because it meets or exceeds the design requirements with the least amount of Portland cement and blast furnace slag. This grout is expected to flow at least 45 feet. A single point of discharge should be sufficient for unrestricted flow conditions. However, additional entry points should be identified as back-up in case restrictions in the tank impede flow. The LP no.8 series of trial mixes had surprisingly high design compressive strengths (2000 to 4000/5000 psi) which were achieved at extended curing times (28 to 90 days, respectively) given the small amount of Portland cement in the mixes (100 to 185 lbs/cyd). The grouts were flowable structural fills containing 3/8 inch gravel and concrete sand aggregate. These grouts did not segregate and require no compaction. They have low permeabilities (≤ 10{sup -9} cm/s) and are consequently expected to be very durable. This series of trial mixes contained by-product materials, i.e., slag and Class F fly ash, and an admixture system initially specified for the grouts used to close Tanks 17-F and 20-F at SRS. The mix designs have low CO{sub 2} footprints because Portland cement contents are very low and can be considered environmentally friendly. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Single-Shell Tank Leak Causes and Locations - 241-B Farm

This document identifies 241-B Tank Farm (B Farm) leak cause and locations for the 100 series leaking tank (241-B-107) identified in RPP-RPT-49089, Hanford B-Farm Leak Inventory Assessments Report. This document satisfies the B Farm portion of the target (T04) in the Hanford Federal Facility Agreement and Consent Order milestone M-045-91F.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗