Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Faraday effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Control of magnon–photon coupling by spin torque

We demonstrate the influence of damping and field-like torques in the magnon–photon coupling process by classically integrating the generalized Landau–Lifshitz–Gilbert equation with RLC equation in which a phase correlation between dynamic magnetization and microwave current through combined Ampère and Faraday effects are considered. We show that the gap between two hybridized modes can be controlled in samples with damping parameter in the order of 10 –3 by changing the direction of the dc current density J if a certain threshold is reached. Furthermore, our results suggest that an experimental realization of the proposed magnon–photon coupling control mechanism is feasible in yttrium iron garnet/Pt hybrid structures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Turbulence link to L-mode, I-mode, and H-mode confinement in the DIII-D tokamak

Understanding the physics of low-confinement (L-), improved-confinement (I-), and high-confinement (H-) modes is critical for fusion reactors. The finding herein reports observations of two types of turbulence coexisting near the L-mode edge, one magnetohydrodynamic (MHD)-like and another micro-tearing mode (MTM)-like, linked to the H-mode and I-mode confinement in the DIII-D tokamak. Ion-scale magnetic and density turbulence is measured using a Faraday-effect radial-interferometer-polarimeter and beam-emission-spectroscopy (BES). Broadband turbulence spectra of up to ~600 kHz are observed in two discharges where transitions between L-mode, I-mode, and H-mode occurs. Turbulence is found to be inversely correlated with confinement, meaning lower turbulence power at higher confinement. Distinctively, the high-frequency (HF, >~100 kHz) magnetic turbulence power changes by the most (55%) during transitions primarily involving energy confinement change, whereas the low-frequency (LF, <~100 kHz) magnetic and density turbulence power changes by the most (80%) during transitions primarily involving particle confinement change. The LF turbulence amplitude oscillates with and leads to deuterium-alpha emission oscillations before an H-mode. These results imply that HF turbulence mainly affects energy confinement whereas LF turbulence can affect particle confinement. The magnetic and density turbulence exhibits coherence up to 0.6 and cross-phase magnitude close to π/2 in most cases, suggesting they have a common origin in both the LF and HF ranges. BES suggests that LF turbulence resides at the edge (ρ = 0.95) and HF turbulence can be at the outer core (ρ = 0.8) or edge (ρ = 0.95). Comparisons of measurements, theory, and gyrokinetic simulations suggest that HF turbulence is MTM-like in all cases, whereas LF turbulence is more consistent with MHD-like modes and the exact instability might change during transitions—except that a drift-wave origin is possible in a low collisionality H-mode. These results suggest that the H-mode involves suppressed MHD-like turbulence, whereas the I-mode mitigates MTM-like turbulence along with largely unchanged MHD-like turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Broadband Ultra-Sensitive Adiabatic Magnetometer

We introduce a new ultra-sensitive adiabatic magnetometer that has a broad bandwidth and can operate in the presence of magnetic fields and gradients. It follows conceptually typical implementations of atomic magnetometers based on alkali-metal vapor cells and lasers for optical pumping and optical Faraday effect detection, while its unique feature is a measurement of an oscillating magnetic field along the probe beam direction at frequencies lower than the resonant frequency, proportional to a static magnetic field along the pump beam direction. The bandwidth of the adiabatic magnetometer scales as the strength of the field along the pump beam. From our theoretical studies it is expected that the adiabatic magnetometer can reach 1 fT sensitivity with a bandwidth of 10 kHz, which any type of atomic magnetometers cannot achieve. Among anticipated various applications of this adiabatic magnetometer are biomagnetic sensing, nuclear magnetic resonance detection, and alkali-metal density measurements. In conclusion, we experimentally conducted alkali-metal density measurements, as an example of applications.

adiabatic magnetometer↗

Super resolution for magneto-optical microscopy

Sub-diffraction limited magneto-optical microscopy, such as Kerr or Faraday effect microscopy, provide many advantages to fields of science and technology for measuring, or imaging, the magnetization structures and magnetization domains of materials. Disclosed is a method and system for performing sub-diffraction limited magneto-optic microscopy. The method includes positioning a microlens or microlens layer relative to a surface of a sample to image the surface of the sample, forming a photonic nanojet to probe the surface of the sample, and receiving light reflected by the surface of the sample or transmitted through the sample at an imaging sensor. The methods and associated systems and devices enable sub-diffraction limited imaging of magnetic domains at resolutions 2 to 8 times the classical diffraction limit.

te Velthuis, Suzanne Gabriëlle Everdine↗

Polarimetry-Interferometry Diagnostic for Magnetic Field and Magnetic Fluctuation Measurements in High-Performance and Long-Pulse Tokamaks (Final Report)

In this grant, we executed a multi-year plan to develop an advanced Faraday-effect polarimeter-interferometer system to address both fluctuation and equilibrium diagnostic needs by providing a measurement of the plasma internal magnetic field fluctuations (including non-axisymmetric 3-D perturbations) and plasma vertical position. This diagnostic included both fast time response and low phase noise so that both the temporal dynamics of equilibrium quantities as well as high-frequency electromagnetic fluctuations could be measured simultaneously, adding new and unique measurement capabilities for the core of high-temperature plasmas. The combined polarimeter-interferometer diagnostic development was applied primarily to the tokamak magnetic configuration, focusing on high-performance regimes including H-mode, reversed shear advanced tokamak scenarios, and non-inductive current drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kerr, Faraday, and magnetoelectric effects in MnBi 2 Te 4 thin films

The topological magnetoelectric effect (TME) is a characteristic property of topological insulators. In this paper, we use a simplified coupled-Dirac-cone electronic structure model to theoretically evaluate the THz and far infrared Kerr and Faraday responses of thin films of MnBi 2 ⁢Te 4 with up to N = 10 septuple layers with the goal of clarifying the relationship between these convenient magnetooptical observables and the TME. Here we find that for even N, the linear Kerr and Faraday responses to an electric field vanish in the low-frequency limit, even though the magnetoelectric response is large and approximately quantized.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Orbital Inverse Faraday and Cotton-Mouton Effects in Hall Fluids

We report two light-induced orbital magnetization effects in quantum Hall (QH) fluids, stemming from their transverse response. The first is a purely transverse contribution to the inverse Faraday effect (IFE), where circularly polarized light induces a dc magnetization by stirring the charged fluid. This contribution dominates the IFE in the QH regime. The second is the orbital inverse Cotton-Mouton effect (ICME), in which linearly polarized light generates a dc magnetization. Since the applied field in the ICME does not break time-reversal symmetry, the induced magnetization directly probes the chiral orbital response of the fluid at the driving frequency. We estimate that the resulting magnetization lies in the range of 0.5–10 Bohr magnetons per charge carrier in materials such as graphene and transition-metal dichalcogenides (TMDs) in the QH regime. Finally, we show that the induced magnetization is accompanied by a local correction to the static particle density, enabling optical quantum printing of density profiles into the QH fluid.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plasma physics in strong-field regimes: Theories and simulations

In strong electromagnetic fields, unique plasma phenomena and applications emerge whose description requires recently developed theories and simulations [Y. Shi, Ph.D. thesis, Princeton University (2018)]. In the classical regime, to quantify effects of strong magnetic fields on three-wave interactions, a convenient formula is derived by solving the fluid model to the second order in general geometry. As an application, magnetic resonances are exploited to mediate laser pulse compression, whereby higher intensity pulses can be produced in wider frequency ranges, as confirmed by particle-in-cell simulations. In even stronger fields, relativistic-quantum effects become important, and a plasma model based on scalar quantum electrodynamics (QED) is developed which unveils observable corrections to Faraday rotation and cyclotron absorption in strongly magnetized plasmas. Beyond the perturbative regime, lattice QED is extended as a numerical tool for plasma physics, using which the transition from wakefield acceleration to electron-positron pair production is captured when laser intensity exceeds the Schwinger threshold.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamic Nuclear Polarization Enhanced Nuclear Spin Optical Rotation

Here, nuclear spin optical rotation (NSOR) has been investigated as a magneto-optical effect, which holds the potential for applications, including hybrid optical-nuclear magnetic resonance (NMR) spectroscopy and gradientless imaging. The intrinsic nature of NSOR renders its detection relatively insensitive, which has prevented it moving from a proof of concept to a method supporting chemical characterizations. In this work, the dissolution dynamic nuclear polarization technique is introduced to provide nuclear spin polarization, increasing the signal-to-noise ratio by several thousand times. NSOR signals of 1 H and 19 F nuclei are observed in a single scan for diluted compounds, which has made this effect suitable for the determination of electronic transitions from a specific nucleus in a large molecule.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

An assessment of generating quasi-static magnetic fields using laser-driven “capacitor” coils

Over the previous decade, numerous experiments have been performed using a laser to drive a strong, quasi-static magnetic field. Field strength and energy density measurements of these experiments have varied by many orders of magnitude, painting a confusing picture of the effectiveness of these laser-driven coils (LDCs) as tools for generating consistent fields. At the higher end of the field energy spectrum, kilotesla field measurements have been used to justify future experimental platforms, theoretical work, and inertial confinement fusion concepts. In this paper, we present the results from our own experiments designed to measure magnetic fields from LDCs as well as a review of the body of experiments that have been undertaken in this field. Here, we demonstrate how problems with prior diagnostic analyses have led to overestimations of the magnetic fields generated from LDCs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rotating Alfvén waves in rotating plasmas

Angular momentum coupling between a rotating magnetized plasma and torsional Alfvén waves carrying orbital angular momentum (OAM) is examined. It is demonstrated not only that rotation is the source of Fresnel–Faraday rotation – or orbital Faraday rotation effects – for OAM-carrying Alfvén waves, but also that angular momentum from an OAM-carrying Alfvén wave can be transferred to a rotating plasma through the inverse process. For the direct process, the transverse structure angular rotation frequency is derived by considering the dispersion relation for modes with opposite OAM content. For the inverse process, the torque exerted on the plasma is derived as a function of wave and plasma parameters.

Physics↗

Faraday rotation study of plasma bubbles in GeV wakefield accelerators

We visualize plasma bubbles driven by 0.67 PW laser pulses in a plasma of density ne≈5×1017cm−3 by imaging Faraday rotation patterns imprinted on linearly polarized probe pulses of wavelength λpr=1.05 μm and duration τpr=2 or 1 ps that cross the bubble's path at right angles. When the bubble captures and accelerates tens to hundreds of pC of electron charges, we observe two parallel streaks of length cτpr straddling the drive pulse propagation axis, separated by ∼45 μm, in which probe polarization rotates by 0.3° to more than 5° in opposite directions. Accompanying simulations show that they result from Faraday rotation within portions of dense bubble side walls that are pervaded by the azimuthal magnetic field of accelerating electrons during the probe transit across the bubble. Analysis of the width of the streaks shows that quasi-monoenergetic high-energy electrons and trailing lower energy electrons inside the bubble contribute distinguishable portions of the observed signals, and relativistic flow of sheath electrons suppresses Faraday rotation from the rear of the bubble. The results demonstrate favorable scaling of Faraday rotation diagnostics to 40× lower plasma density than previously demonstrated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magneto-optical measurement of magnetic field and electrical current on a short pulse high energy pulsed power accelerator

We describe a direct magneto-optical approach to measuring the magnetic field driven by a narrow pulse width (<10 ns), 20 kA electrical current flow in the transmission line of a high energy pulsed power accelerator. The magnetic field and electrical current are among the most important operating parameters in a pulsed power accelerator and are critical to understanding the properties of the radiation output. However, accurately measuring these fields and electrical currents using conventional pulsed power diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element sensing crystal sensor that is highly resistant to electromagnetic interference and does not require external calibration. Here, we focus on device theory, operating parameters, results from an experiment on a high energy pulsed power accelerator, and comparison to a conventional electrical current shunt sensor.

42 ENGINEERING↗

High-magnification Faraday rotation imaging and analysis of X-pinch implosion dynamics

An X-pinch load driven by an intense current pulse (>100 kA in ~100 ns) can result in the formation of a small radius, runaway compressional micro-pinch. A micro-pinch is characterized by a hot (>1 keV), current-driven (>100 kA), high-density plasma column (near solid density) with a small neck diameter (1–10 µm), a short axial extent (<1 mm), and a short duration (≲1 ns). With material pressures often well into the multi-Mbar regime, a micro-pinch plasma often radiates an intense, sub-ns burst of sub-keV to multi-keV x rays. A low-density coronal plasma immediately surrounding the dense plasma neck could potentially shunt current away from the neck and thus reduce the magnetic drive pressure applied to the neck. Here, to study the current distribution in the coronal plasma, a Faraday rotation imaging diagnostic (1064 nm) capable of producing simultaneous high-magnification polarimetric and interferometric images has been developed for the MAIZE facility at the University of Michigan. Designed with a variable magnification (1–10×), this diagnostic achieves a spatial resolution of ~35 µm, which is useful for resolving the ~100-μm-scale coronal plasma immediately surrounding the dense core. This system has now been used on a reduced-output MAIZE (100–200 kA, 150 ns) to assess the radial distribution of drive current immediately surrounding the dense micro-pinch neck. The total current enclosed was found to increase as a function of radius, r, from a value of ≈ 50 ± 25 kA at r ≈ 140 µm (at the edge of the dense neck) to a maximal value of ≈150 ± 75 kA for r ≥ 225 µm. This corresponds to a peak magnetic drive pressure of ≈75 ± 50 kbar at r ≈ 225 µm. The limitations of these measurements are discussed in the paper.

47 OTHER INSTRUMENTATION↗

The Global Magneto-ionic Medium Survey: A Faraday Depth Survey of the Northern Sky Covering 1280–1750 MHz

The Galactic interstellar medium hosts a significant magnetic field, which can be probed through the synchrotron emission produced from its interaction with relativistic electrons. Linearly polarized synchrotron emission is generated throughout the Galaxy and, at longer wavelengths, modified along nearly every path by Faraday rotation in the intervening magneto-ionic medium. Full characterization of the polarized emission requires wideband observations with many frequency channels. We have surveyed polarized radio emission from the Northern sky over the range 1280–1750 MHz, with channel width 236.8 kHz, using the John A. Galt Telescope (diameter 25.6 m) at the Dominion Radio Astrophysical Observatory, as part of the Global Magneto-Ionic Medium Survey. The survey covered 72% of the sky, decl. −30° to +87° at all R.A. The intensity scale was absolutely calibrated, based on the flux density and spectral index of Cygnus A. Polarization angle was calibrated using the extended polarized emission of the Fan Region. Data are presented as brightness temperatures with angular resolution 40′. Sensitivity in Stokes Q and U is 45 mK rms in a 1.18 MHz band. We have applied rotation measure synthesis to the data to obtain a Faraday depth cube of resolution 150 rad m{sup −2} and sensitivity 3 mK rms of polarized intensity. Features in Faraday depth up to a width of 110 rad m{sup −2} are represented. The maximum detectable Faraday depth is ±2 × 10{sup 4} rad m{sup −2}. The survey data are available at the Canadian Astronomy Data Centre.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fractional magnetic charges and channeling of Faraday lines by disclinations in artificial spin ice

We have studied the magnetic moments of artificial spin ice arrays of nanomagnets in both undistorted square arrays and in arrays with a topological defect induced by a single disclination. We confirm that the disclination induces global, macroscopic changes in the low-energy collective states of the nanomagnet moment configuration. Specifically, the disclination leads to Faraday lines of effective magnetic flux that run from the center all the way to the edge of the arrays. Moreover, the geometric deformation, induced by the topological defect, curves the geometry such that these Faraday lines are channeled preferentially by the arrays’ curved geometry. Our results demonstrate how the intentional combination of topology and geometry can be designed to control magnetic charges and the flow of local magnetization and thus manipulate associated collective excitations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of quasi-collisional effects in laboratory and astrophysical plasmas

High-amplitude turbulence excited in plasmas at small-scales can leave imprint on the radiation produced by (accelerated) plasma particles -- mostly electrons in electron-ion plasmas and both electrons and positrons in lepton pair plasmas. Furthermore, turbulence is known to introduce "effective collisional" effects -- anomalous resistivity, dissipation, diffusion, etc. -- in the otherwise collisionless plasmas. These effective collisions affect radiation transfer and modify optical and magneto-optic effects -- the transmittance and reflectivity coefficients, Faraday rotation, etc. Note that the effective collisions considered in this project are not resonant wave-particle interactions, but much less conventional randomization of particles’ paths. Therefore, we colloquially refer them to as "quasi-collisions". The study of quasi-collisions on transport, radiative and optical properties of plasmas is the main focus of this project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Density Functional Theory Study of Controllable Optical Absorptions and Magneto-Optical Properties of Magnetic CrI 3 Nanoribbons: Implications for Compact 2D Magnetic Devices

A chromium triiodide (CrI 3 ) monolayer has an interesting ferromagnetic ground-state. In this work, we calculate band structures and magnetic moments of tensile-strained and bent zigzag CrI 3 nanoribbons with density functional theory. The edge iodine atoms form flat low-lying conduction bands and couple with chromium atoms ferromagnetically, while the non-edge iodine atoms weakly couple antiferromagnetically. Narrow CrI 3 nanoribbons have two locally stable magnetic moment orientations, namely out-of-plane and in-plane (along the nanoribbon periodic direction) configurations. This enables four magnetization states in CrI 3 nanoribbons, including two out-of-plane ones (up and down) and two in-plane ones (forward and backward along the nanoribbon periodical direction), increasing the operating controllability. Based on the one-dimensional Ising spin chain model, the spin correlation length of the narrow CrI 3 nanoribbon is estimated as about 10 Å at its estimated Curie temperature of 27 Kelvin, which is lower than the measured 45 Kelvin of the monolayer CrI 3 . The optical absorption and magneto-optical properties of CrI 3 nanoribbons are investigated with many-body perturbation GW-BSE (Bethe-Salpeter equation), including magnetic dichroism, Faraday and magneto-optical Kerr effects. Here, the low-energy dark excitons are mainly from transitions between electrons and holes with unlike spins and are non-Frenkel-like, while the bright excitons have mixed spin configurations. The intrinsic lifetime of excitons can be over one nanosecond, suitable for quantum information processes. Tensile strains and bending manifestly modulate the absorption spectra and magneto-optical properties of CrI 3 nanoribbons within a technologically important photon energy-range of ~1.0-2.0 eV. The CrI 3 nanoribbons can be used in 1D or 2D magnetic storage nanodevices, tunable magnetic optoelectronics, and spin-based quantum information controls.

36 MATERIALS SCIENCE↗