Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Failure Diameter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ductility in rapidly solidified NiAl

An attempt is made to refine the grain structure of equiatomic NiAl by means of rapid solidification processing, and to examine the effect of small grain size on room temperature ductility. Free melt spinning was used to produce the rapidly solidified material. Room temperature bend testing of both as-spun and heat-treated NiAl ribbon was conducted by free bending the ribbon around a mandrel of successively smaller diameter until failure occurred. Room-temperature plastic deformation was exhibited both before and after a 1-h heat treatment at 1000 C. Heat treatment increased the observed ductility.

Gaydosh, D. J.↗

Larger Maximum Tumor Diameter at Radical Prostatectomy Is Associated With Increased Biochemical Failure, Metastasis, and Death From Prostate Cancer After Salvage Radiation for Prostate Cancer

Purpose: To investigate the maximum tumor diameter (MTD) of the dominant prostate cancer nodule in the radical prostatectomy specimen as a prognostic factor for outcome in patients treated with salvage external beam radiation therapy (SRT) for a rising prostate-specific antigen (PSA) value after radical prostatectomy. Methods and Materials: From an institutional cohort of 575 patients treated with SRT, data on MTD were retrospectively collected. The impact of MTD on biochemical failure (BF), metastasis, and prostate cancer-specific mortality (PCSM) was assessed on univariate and multivariate analysis using Kaplan-Meier and Cox proportional hazards models. Results: In the 173 patients with MTD data available, median follow-up was 77 months (interquartile range, 47-104 months) after SRT, and median MTD was 18 mm (interquartile range, 13-22 mm). Increasing MTD correlated with increasing pT stage, Gleason score, presence of seminal vesicle invasion, and lymph node invasion. Receiver operating characteristic curve analysis identified MTD of >14 mm to be the optimal cut-point. On univariate analysis, MTD >14 mm was associated with an increased risk of BF (P=.02, hazard ratio [HR] 1.8, 95% confidence interval [CI] 1.2-2.8), metastasis (P=.002, HR 4.0, 95% CI 2.1-7.5), and PCSM (P=.02, HR 8.0, 95% CI 2.9-21.8). On multivariate analysis MTD >14 mm remained associated with increased BF (P=.02, HR 1.9, 95% CI 1.1-3.2), metastasis (P=.02, HR 3.4, 95% CI 1.2-9.2), and PCSM (P=.05, HR 9.7, 95% CI 1.0-92.4), independent of extracapsular extension, seminal vesicle invasion, positive surgical margins, pre-RT PSA value, Gleason score, and pre-RT PSA doubling time. Conclusions: For patients treated with SRT for a rising PSA value after prostatectomy, MTD at time of radical prostatectomy is independently associated with BF, metastasis, and PCSM. Maximum tumor diameter should be incorporated into clinical decision making and future clinical risk assessment tools for those patients receiving SRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Impact Damage and Open Holes on the Compression Strength of Tough Resin/high Strain Fiber Laminates

Tests to assess the performance of composite structures damaged by impact or containing local discontinuities such as cutouts are discussed. In particular, two plate specimen test configurations which were developed to define the serverity of compression strength reduction are described; one for impact damage and the other open hole specimens. The test technique for impact specimens involves damaging the plate at selected energies, measuring the size of damage by ultrasonic C-scan techniques and measuring the residual strength in a compression load test. Open-hole specimen compression tests are conducted for several different hole diameters and the failure strain and load and mode of failure recorded. The plate specimen used in these tests is designed with length, width, thickness and laminate stiffness to ensure that overall plate buckling is not responsible for initiating failure.

Williams, J. G.↗

Microwave Ablation of Porcine Kidneys in vivo: Effect of two Different Ablation Modes ('Temperature Control' and 'Power Control') on Procedural Outcome

Purpose: This study was designed to analyze the effect of two different ablation modes ('temperature control' and 'power control') of a microwave system on procedural outcome in porcine kidneys in vivo. Methods: A commercially available microwave system (Avecure Microwave Generator; MedWaves, San Diego, CA) was used. The system offers the possibility to ablate with two different ablation modes: temperature control and power control. Thirty-two microwave ablations were performed in 16 kidneys of 8 pigs. In each animal, one kidney was ablated twice by applying temperature control (ablation duration set point at 60 s, ablation temperature set point at 96 Degree-Sign C, automatic power set point; group I). The other kidney was ablated twice by applying power control (ablation duration set point at 60 s, ablation temperature set point at 96 Degree-Sign C, ablation power set point at 24 W; group II). Procedural outcome was analyzed: (1) technical success (e.g., system failures, duration of the ablation cycle), and (2) ablation geometry (e.g., long axis diameter, short axis diameter, and circularity). Results: System failures occurred in 0% in group I and 13% in group II. Duration of the ablation cycle was 60 {+-} 0 s in group I and 102 {+-} 21 s in group II. Long axis diameter was 20.3 {+-} 4.6 mm in group I and 19.8 {+-} 3.5 mm in group II (not significant (NS)). Short axis diameter was 10.3 {+-} 2 mm in group I and 10.5 {+-} 2.4 mm in group II (NS). Circularity was 0.5 {+-} 0.1 in group I and 0.5 {+-} 0.1 in group II (NS). Conclusions: Microwave ablations performed with temperature control showed fewer system failures and were finished faster. Both ablation modes demonstrated no significant differences with respect to ablation geometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interior morphology of fresh Martian craters - The effects of target characteristics

The interior morphology of 183 fresh Martian craters observed on Viking imagery was studied. Freshness was determined by rim sharpness and continuity according to the scheme used to classify lunar and Mercurian craters. Results indicate that central-peak and wall degradation features are more common than previously thought. Central peaks are observed in craters as small as 2 km in diameter and in nearly all fresh craters with diameters greater than 10 km. Scallops or terraces are found to occur in all craters with diameters greater than 20 km, and wall slumping seems common in craters from 5 to 10 km in diameter. The ratio of crater diameter to crater floor diameter is significantly larger than for lunar craters. Central peaks and pits are more frequent in craters formed in cratered terrain than in those formed on plains; wall failure occurs at smaller diameters in plains craters. It is suggested that these peculiarities of crater interior morphologies may be due to a subsurface volatile layer. The influence of target variations on the interior morphologies observed in fresh craters was studied. Preliminary results indicate well-defined effects due to target differences.

Wood, C. A.↗

Efficacy and Safety of Augmenting the Preclose Technique with a Collagen-Based Closure Device for Percutaneous Endovascular Aneurysm Repair

PurposeTo report our experience of selectively augmenting the preclose technique for percutaneous endovascular aneurysm repair (p-EVAR) with an Angio-Seal device as a haemostatic adjunct in cases of significant bleeding after tensioning the sutures of the suture-mediated closure devices.Materials and MethodsProspectively collected data for p-EVAR patients at our institute were analysed. Outcomes included technical success and access site complications. A logistic regression model was used to analyse the effects of sheath size, CFA features and stent graft type on primary failure of the preclose technique necessitating augmentation and also on the development of complications.Resultsp-EVAR was attempted via 122 CFA access sites with a median sheath size of 18-French (range 12- to 28-French). Primary success of the preclose technique was 75.4 % (92/122). Angio-Seal augmentation was utilised as an adjunct to the preclose technique in 20.5 % (25/122). The overall p-EVAR success rate was 95.1 % (116/122). There was a statistically significant relationship (p = 0.0093) between depth of CFA and primary failure of preclose technique. CFA diameter, calcification, type of stent graft and sheath size did not have significant effects on primary preclose technique failure. Overall 4.9 % (6/122) required surgical conversion but otherwise there were no major complications.ConclusionAugmentation with an Angio-Seal device is a safe and effective adjunct to increase the success rate of the preclose technique in p-EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Topographical shifts in fine root lifespan in a mixed, mesic temperate forest

Root lifespan, often is estimated in landscape- and ecosystem-level carbon models using linear approximations. In water manipulation experiments, fine root lifespan can vary with soil water content. Soil water content is generally structured by complex topography, which is largely unaccounted for in landscape- and ecosystem-scale carbon models. Topography governs the range of soil water content experienced by roots which may impact their lifespan. We hypothesized that root lifespan varied nonlinearly across a temperate, mesic, forested catchment due to differences in soil water content associated with topographic position. We expected regions of the landscape that were too wet or too dry would have soils that were not optimal for roots and thus result in shorter root lifespans. Specifically, we hypothesized that root lifespan would be longest in areas that consistently had soil water content in the middle of the soil water content spectrum, while in soils at either very low or very high soil water content, root lifespan would be relatively short. We tested this hypothesis by collecting and analyzing two years of minirhizotron and soil moisture data in plots widely distributed in the Shale Hills catchment of the Susquehanna-Shale Hills Critical Zone Observatory in Pennsylvania. We found that fine root lifespans were longer in traditionally wetter topographic regions, but detected no short term (biweekly) effect of soil moisture on root lifespan. Additionally, depth in soil, soil series, slope face orientation, and season of birth strongly affected root lifespans across the catchment. In contrast, lifespan was unaffected by root diameter or mycorrhizal association. Failure to account for these variables could result in erroneous estimates of fine root lifespan and, consequentially, carbon flux in temperate forested regions.

54 ENVIRONMENTAL SCIENCES↗

Buckling tests of two 4.6-meter-diameter, magnesium ring-stiffened conical shells loaded under external pressure

Two ring-stiffened magnesium conical shells with a 120 deg apex angle and a 4.6-meter diameter were loaded to failure by a uniform external pressure. The cones differed from one another only in the number of internal stiffening rings. Test specimen details, test procedure, and test results are discussed. Both buckling and prebuckling data are compared with appropriate theoretical predictions. Measured strains in skin and rings agreed well with theoretical predictions. Extensive imperfection measurements were made and reported on both cones in the as fabricated condition.

Anderson, J. K.↗

Buckling tests of three 4.6 meter diameter aluminum honeycomb sandwich conical shells loaded under external pressure

Three aluminum honeycomb sandwich conical shells with a 120 apex angle and a 4.6-m (15.0-ft) base diameter were loaded to failure by a uniform external pressure. The cones differed from one another only in the thickness of their respective face sheets. Test specimen details, test procedure, and test results are discussed. Both buckling and prebuckling data are compared with appropriate theoretical predictions, and good agreement was obtained between test and theory. Extensive imperfection measurements were made and reported on the three cones in the as fabricated condition.

Anderson, J. K.↗

Guidelines for predicting stress in cemented doublets undergoing temperature change

This work explores quick predictive methods for calculating potentially risky stresses and deflections in cemented doublets experiencing temperature change that agree well with finite element analysis. There are three failure modes of interest: cohesive failure of the adhesive, delamination (surface bond failure or debonding), and glass fracture. Adhesive theory, confirmed by finite element analysis, predicts stress singularities that complicate interpretation of the stress calculations. The presence of a stress singularity indicates the breakdown of linear elastic assumptions, but damage initiation and stress singularities are related. The authors find that geometry details near a bond edge can exacerbate or minimize damage initiation and stress concentrations. Because the interpretation of the stress results is complicated, the authors investigated predicted stresses in doublets that have been successfully tested between -40 and 85 °C. This study found that the product (ΔT ∙ Δα) should be less than 189 ppm, where ΔT is the temperature excursion and Δα is the difference in glass coefficient of thermal expansion. If the product (ΔT ∙ Δα) is equal to or greater than 189 ppm, further analysis and testing is warranted. But the authors also show that the fabrication process can significantly influence stress failure, particularly with large diameter doublets.

47 OTHER INSTRUMENTATION↗

Guidelines for predicting stress in cemented doublets undergoing temperature change

This work explores quick predictive methods for calculating potentially risky stresses and deflections in cemented doublets experiencing temperature change that agree well with finite element analysis. There are three failure modes of interest: cohesive failure of the adhesive, delamination (surface bond failure or debonding), and glass fracture. Adhesive theory, confirmed by finite element analysis, predicts stress singularities that complicate interpretation of the stress calculations. The presence of a stress singularity indicates the breakdown of linear elastic assumptions, but damage initiation and stress singularities are related. The authors find that geometry details near a bond edge can exacerbate or minimize damage initiation and stress concentrations. Because the interpretation of the stress results is complicated, the authors investigated predicted stresses in doublets that have been successfully tested between -40 and 85 °C. This study found that the product (∆T ∙ ∆α) should be less than 189 ppm, where ∆T is the temperature excursion and ∆α is the difference in glass coefficient of thermal expansion. If the product (∆T ∙ ∆α) is equal to or greater than 189 ppm, further analysis and testing is warranted. But the authors also show that the fabrication process can significantly influence stress failure, particularly with large diameter doublets

42 ENGINEERING↗

C-Sphere Strength-Size Scaling in a Bearing-Grade Silicon Nitride

A C-sphere specimen geometry was used to determine the failure strength distributions of a commercially available bearing-grade silicon nitride (Si3N4) having ball diameters of 12.7 and 25.4 mm. Strengths for both diameters were determined using the combination of failure load, C sphere geometry, and finite element analysis and fitted using two-parameter Weibull distributions. Effective areas of both diameters were estimated as a function of Weibull modulus and used to explore whether the strength distributions predictably strength-scaled between each size. They did not. That statistical observation suggested that the same flaw type did not limit the strength of both ball diameters indicating a lack of material homogeneity between the two sizes. Optical fractography confirmed that. It showed there were two distinct strength-limiting flaw types in both ball diameters, that one flaw type was always associated with lower strength specimens, and that significantly higher fraction of the 24.5-mm-diameter c-sphere specimens failed from it. Predictable strength-size-scaling would therefore not result as a consequence of this because these flaw types were not homogenously distributed and sampled in both c-sphere geometries.

36 MATERIALS SCIENCE↗

The compressive failure of graphite/epoxy plates with circular holes

The results of an experimental investigation of the compressive behavior of T300/5203 graphite/epoxy laminated plates measuring 127.0 by 254.0 mm and containing circular holes ranging to 38.1 mm are reported. Two thicknesses, 24-ply and 48-ply, were chosen to differentiate between stability failures resulting from buckling and strength failures caused by the hole. Both quasi-isotropic and orthotropic stacking arrangements were used. The critical buckling load of the 24-ply panels was independent of hole size. Bifurcation occurred in the two half-wave mode longitudinally and one half-wave mode laterally in the quasi-isotropic panels. For the orthotropic 24-ply panels, bifurcation began in the one half-wave mode shape in each direction, but changed to the two half-wave mode before failure. Consistent post-buckling strength was exhibited by both laminated configurations. Panels with hole diameters below 3.175 mm displayed buckling before failure; those with holes larger than 6.35 mm experienced material failure around the hole before panel collapse.

Knauss, J. F.↗

Experimental Investigation of Composite Pressure Vessel Performance and Joint Stiffness for Pyramid and Inverted Pyramid Joints

The focus of this study is on the suitability in the application of classical laminate theory analysis tools for filament wound pressure vessels with adhesive laminated joints in particular: pressure vessel wall performance, joint stiffness and failure prediction. Two 18-inch diameter 12-ply filament wound pressure vessels were fabricated. One vessel was fabricated with a 24-ply pyramid laminated adhesive double strap butt joint. The second vessel was fabricated with the same number of plies in an inverted pyramid joint. Results from hydrostatic tests are presented. Experimental results were used as input to the computer programs GENLAM and Laminate, and the output compared to test. By using the axial stress resultant, the classical laminate theory results show a correlation within 1% to the experimental results in predicting the pressure vessel wall pressure performance. The prediction of joint stiffness for the two adhesive joints in the axial direction is within 1% of the experimental results. The calculated hoop direction joint stress resultant is 25% less than the measured resultant for both joint configurations. A correction factor is derived and used in the joint analysis. The correction factor is derived from the hoop stress resultant from the tank wall performance investigation. The vessel with the pyramid joint is determined to have failed in the joint area at a hydrostatic pressure 33% value below predicted failure. The vessel with the inverted pyramid joint failed in the wall acreage at a hydrostatic pressure within 10% of the actual failure pressure.

Verhage, Joseph M.↗

Inflatable Structures: Test Results and Development Progress Since TransHab

JSC's TransHab project was the first successful development program to prove the viability of inflatable habitats for space applications. Although TransHab was cancelled in 2000, significant progress has been made this past year by JSC engineers. Since February 2005, the following test articles have been manufactured and tested: 1 - An 88-in diameter restraint layer was pressure-tested to failure and reached an ultimate pressure of 197psi. This test article demonstrated the ability to build a 35- foot diameter inflatable with a factor of safety of 4.0 at 10.2 psi. 2 - An 88-in diameter restraint layer with a window frame incorporated into the restraint layer was tested to failure and reached an ultimate pressure of 197 psi. This test article demonstrated the ability to incorporate windows and other structural penetrations in the woven restraint layer without reducing its strength. 3 - An 88-inch diameter folding demonstrator that includes a bladder, restraint layer, and all of the MMOD shell layers was manufactured and assembled. This test article demonstrated an improved and simplified shell assembly and folding technique which installs pre-folded shell sections in a controlled manner. 4 - Fifth-scale MMOD hypervelocity test articles have demonstrated fiberglass as a viable material for a MMOD bumper shield which is cheaper and more readily available than previously used materials. In addition, four different full-scale advanced shape inflatable mockups have been manufactured and evaluated for applications such as lunar habitats, airlocks, and transfer tunnels.

Johnson, Chris↗

Effect of wall thickness and material on flexural fatigue of hollow rolling elements

Hollow cylindrical bars were tested in a rolling-contact fatigue tester to determine the effects of material and outside diameter to inside diameter (OD/ID) ratios on fatigue failure mode and subsequent failure propagation. The range of applied loads with OD/ID ratios of 2.0, 1.6, 1.4, and 1.2 resulted in maximum tangential tensile stresses ranging from 165 to 655 MPa at the bore surface. Flexural failures of the hollow test bars occurred when this bore stress was 490 MPa or greater with AISI 52100 hollow bars and 338 MPa or greater with AISI M-50 hollow bars. Good correlation was obtained in relating the failures of these hollow bars with flexural failures of drilled balls from full-scale bearing test published previously.

Bamberger, E. N.↗

Tensile and compressive mechanical behavior of twinned silicon carbide nanowires

Molecular dynamics simulations with the Tersoff potential were used to study the response of twinned SiC nanowires under tensile and compressive strains. The critical strain of the twinned nanowires can be enhanced by twin-stacking faults, and their critical strains are larger than those of perfect nanowires with the same diameters. Under axial tensile strain, the bonds of the nanowires are just stretched before failure. The failure behavior is found to depend on the twin segment thickness and the diameter of the nanowires. An atomic chain is observed for the thin nanowires with small twin segment thickness under tension strain. Under axial compressive strain, the collapse of the twinned SiC nanowires exhibits two differently failure modes, depending on the length and diameter of the nanowires, i.e. shell buckling for short length nanowires and columnar buckling for longer length nanowires.

36 MATERIALS SCIENCE↗