Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FUNCTION TEST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The alteration of profile analysis to accommodate testing functions

The development of a methodology was studied for testing differences among several pilot functions, where the data points represent averages at various frequencies. Topics discussed include: basic assumptions, hypothesis, profile analysis, alteration of profile analysis to accommodate testing functions, test and procedures, and power of tests.

Myers, R. H.↗

Hubble Space Telescope On-orbit Transfer Function Test

The paper describes the On-orbit Transfer Function Test (TFT) designed for on-orbit vibration testing of the Hubble Space Telescope (HST). The TFT provides means for extracting accurate on-orbit characteristics of HST flexible body dynamics, making it possible to check periodically the state of the vehicle on-orbit and to assess changes in modal parameters.

Vadlamudi, N.↗

A Scalable Test-Bed for Direct Current Current Transformer Automated Functional Testing and Characterization

This article describes a scalable test-bed for automation of measurements of the direct current current transformers (DCCT). Automation of measurement involves functional measurements, fault event based measurements and data validation. The test-bed is designed to measure up to 20 DCCTs at a time with software based measurement repetition checks and validation of the measurements.

43 PARTICLE ACCELERATORS↗

System Level TVAC Functional Testing for the Integrated LCRD Low-Earth Orbit User Modem and Amplifier Terminal (ILLUMA-T) Payload Destined for the International Space Station

The Integrated LCRD Low-Earth Orbit User Modem and Amplifier Terminal (ILLUMA-T) Payload will be launched to the International Space Station (ISS) in 2023. ILLUMA-T is an optical communications payload that will make the ISS the first space-based user to communicate with NASA’s Laser Communications Relay Demonstration (LCRD). The system will support all-optical forward links up to 150 Mbps and return links up to 1 Gbps. The payload recently underwent system level Thermal VACuum (TVAC) functional testing at MIT Lincoln Laboratory. We present an overview of the payload’s TVAC functional tests and results.

lasercom↗

System Level TVAC Functional Testing for the Integrated LCRD Low-Earth Orbit User Modem and Amplifier Terminal (ILLUMA-T) Payload Destined for the International Space Station

The Integrated LCRD Low-Earth Orbit User Modem and Amplifier Terminal (ILLUMA-T) payload will be launched to the International Space Station (ISS) in 2023. ILLUMA-T is an optical communications payload that will make the ISS the first space-based user to communicate with NASA’s Laser Communications Relay Demonstration (LCRD). The system will support all-optical forward links up to 150 Mbps and return links up to 1 Gbps. The payload recently underwent system level Thermal VACuum (TVAC) functional testing at MIT Lincoln Laboratory. We present an overview of the payload’s TVAC functional tests and results.

laser communications↗

Wind Turbine Safety and Function Test Report for the ARE 442 Wind Turbine

This test was conducted as part of the U.S. Department of Energy's (DOE) Independent Testing project. This project was established to help reduce the barriers of wind energy expansion by providing independent testing results for small turbines. In total, four turbines were tested at the National Wind Technology Center (NWTC) as a part of this project. Safety and function testing is one of up to five tests that were performed on the turbines, including power performance, duration, noise, and power quality tests. Test results provide manufacturers with reports that can be used for small wind turbine certification. The test equipment includes an ARE 442 wind turbine mounted on a 100-ft free-standing lattice tower. The system was installed by the NWTC Site Operations group with guidance and assistance from Abundant Renewable Energy.

17 WIND ENERGY↗

A multi-functional testing instrument for heat assisted magnetic recording media

With recent developments in heat assisted magnetic recording (HAMR), characterization of HAMR media is becoming very important. We present a multi-functional instrument for testing HAMR media, which integrates HAMR writing, reading, and a micro-magneto-optic Kerr effect (μ-MOKE) testing function. A potential application of the present instrument is to make temperature dependent magnetic property measurement using a pump-probe configuration. In the measurement, the media is heated up by a heating (intense) beam while a testing (weak) beam is overlapped with the heating beam for MOKE measurement. By heating the media with different heating beam power, magnetic measurements by MOKE at different temperatures can be performed. Compared to traditional existing tools such as the vibrating sample magnetometer, the present instrument provides localized and efficient heating at the measurement spot. The integration of HAMR writing and μ-MOKE system can also facilitate a localized full investigation of the magnetic media by potential correlation of HAMR head independent write/read performance to localized magnetic properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wind Turbine Safety and Function Test Report for the Mariah Windspire Wind Turbine

This test was conducted as part of the U.S. Department of Energy's (DOE) Independent Testing project. This project was established to help reduce the barriers to wind energy expansion by providing independent testing results for small wind turbines (SWT). In total, five turbines were tested at the National Wind Technology Center (NWTC) as a part of this project. Safety and function testing is one of up to five tests performed on the turbines, including power performance, duration, noise, and power-quality tests. NWTC testing results provide manufacturers with reports that may be used to meet part of small wind turbine certification requirements. The test equipment includes a Mariah Windspire wind turbine mounted on a monopole tower. L&E Machine manufactured the turbine in the United States. The inverter was manufactured separately by Technology Driven Products in the United States. The system was installed by the NWTC site operations group with guidance and assistance from Mariah Power.

17 WIND ENERGY↗

Wind Turbine Safety and Function Test Report for the Gaia-Wind 11-kW Wind Turbine

This test was conducted as part of the U.S. Department of Energy's (DOE) Independent Testing project. This project was established to help reduce the barriers to wind energy expansion by providing independent testing results for small wind turbines (SWT). In total, four turbines were tested at the National Wind Technology Center (NWTC) as a part of this project. Safety and function testing is one of up to five tests performed on the turbines, including power performance, duration, noise, and power-quality tests. The results of the testing provide the manufacturers with reports that can be used for small wind turbine certification. The test equipment includes a Gaia-Wind 11-kW wind turbine mounted on an 18-m monopole tower. Gaia-Wind Ltd. manufactured the turbine in Denmark. The system was installed by the NWTC site operations group with guidance and assistance from Gaia-Wind.

17 WIND ENERGY↗

A system for the functional testing and simulation of custom and semicustom VLSI chips

A system for the functional testing and simulation of custom and semicustom very large scale integrated (VLSI) chips that are designed using the integrated UNIX-based computer-aided design (CAD) system is described. The testing and simulation system consists of two parts. One of these is a special purpose hardware device that is capable of controlling the digital imputs and outputs on a custom chip. This device, the Digital Microcircuit Functionality Tester (DMFT) system, can be operated by itself or in conjunction with the VAX host computer on the CAD system. The DMFT is integrated into a microprobe station so that these signals can be injected or read from nodes inside the chip, as well as at the pins. The second part of the system is a software package that is installed on the VAX. This software package, logic, includes a full-screen editor for developing chip test sequences and drivers for both the DMFT and the esim logic simulator.

Olson, E. M.↗

The Full Function Test Explosive Generator

We have conducted three tests of a new pulsed power device called the Full Function Test (FFT). These tests represented the culmination of an effort to establish a high energy pulsed power capability based on high explosive pulsed power (HEPP) technology. This involved an extensive computational modeling, engineering, fabrication, and fielding effort. The experiments were highly successful and a new US record for magnetic energy was obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulmonary Ventilation Imaging Based on 4-Dimensional Computed Tomography: Comparison With Pulmonary Function Tests and SPECT Ventilation Images

Purpose: 4-dimensional computed tomography (4D-CT)-based pulmonary ventilation imaging is an emerging functional imaging modality. The purpose of this study was to investigate the physiological significance of 4D-CT ventilation imaging by comparison with pulmonary function test (PFT) measurements and single-photon emission CT (SPECT) ventilation images, which are the clinical references for global and regional lung function, respectively. Methods and Materials: In an institutional review board–approved prospective clinical trial, 4D-CT imaging and PFT and/or SPECT ventilation imaging were performed in thoracic cancer patients. Regional ventilation (V{sub 4DCT}) was calculated by deformable image registration of 4D-CT images and quantitative analysis for regional volume change. V{sub 4DCT} defect parameters were compared with the PFT measurements (forced expiratory volume in 1 second (FEV{sub 1}; % predicted) and FEV{sub 1}/forced vital capacity (FVC; %). V{sub 4DCT} was also compared with SPECT ventilation (V{sub SPECT}) to (1) test whether V{sub 4DCT} in V{sub SPECT} defect regions is significantly lower than in nondefect regions by using the 2-tailed t test; (2) to quantify the spatial overlap between V{sub 4DCT} and V{sub SPECT} defect regions with Dice similarity coefficient (DSC); and (3) to test ventral-to-dorsal gradients by using the 2-tailed t test. Results: Of 21 patients enrolled in the study, 18 patients for whom 4D-CT and either PFT or SPECT were acquired were included in the analysis. V{sub 4DCT} defect parameters were found to have significant, moderate correlations with PFT measurements. For example, V{sub 4DCT}{sup HU} defect volume increased significantly with decreasing FEV{sub 1}/FVC (R=−0.65, P<.01). V{sub 4DCT} in V{sub SPECT} defect regions was significantly lower than in nondefect regions (mean V{sub 4DCT}{sup HU} 0.049 vs 0.076, P<.01). The average DSCs for the spatial overlap with SPECT ventilation defect regions were only moderate (V{sub 4DCT}{sup HU}0.39 ± 0.11). Furthermore, ventral-to-dorsal gradients of V{sub 4DCT} were strong (V{sub 4DCT}{sup HU} R{sup 2} = 0.69, P=.08), which was similar to V{sub SPECT} (R{sup 2} = 0.96, P<.01). Conclusions: An 18-patient study demonstrated significant correlations between 4D-CT ventilation and PFT measurements as well as SPECT ventilation, providing evidence toward the validation of 4D-CT ventilation imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assembly and Functional Test of NRAD Heated Instrumentation Rig

This is a technical report (TEV-4296) which documents the configuration and materials of construction for a heated sensor test conducted in the NRAD reactor. It is being reviewed for external release so that operators of university reactors can evaluate whether this level of documentation will be acceptable for similar tests conducted in their reactors. The Objective section of this TEV is reproduced below. The purpose of this TEV is to document assembly and functional testing of a device which is designed to allow advanced sensors to be temporarily placed at the periphery of the NRAD reactor. While in this location, the operational characteristics of the sensors can be evaluated while they are exposed to a neutron flux. This device (or “rig”) consists of a cartridge heater surrounded by six guide tubes, which are in turn surrounded by insulation and an aluminum dry tube. The heater allows for the sensors to be tested while at elevated temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗